• Title/Summary/Keyword: opaque-2

Search Result 278, Processing Time 0.025 seconds

Some Aspects of High Lysine Maize Breeding using Opaque-2 Gene (Opaque-2 인자를 이용한 고라이신 옥수수의 육종)

  • Bong-Ho Chae
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.5 no.1
    • /
    • pp.57-64
    • /
    • 1969
  • Several field and sweet corn varietiea from several sources were crossed with a variety carrying the opaque-2 gene to determine the phenotypic interactions in the breeding of high lysine maize. Although opaque-2 lines showed lower protein content than the corresponding normal varieties, there was no correlation between the protein levels of the two types. opaque-2 maize contained more lysine, but no relationship was found between the protein content and the lysine content of either normal or opaque-2 types, suggesting that high lysine corn using the opaque-2 gene may be developed independently from the protein content. The F2 segregation ratios for normal and opaque-2, 100-kernel weights, percentage seed set, opaque-2 phenotype, disease susceptibility, and the relationship between protein and lysine content of normal and opaque-2 were investigated. The determinations and observations were made on the F2, F3, and BC1 Lysine content was determined by the ion exchangeresin combined with paper chromatography method. Most crosses segregated in a 1-opaque-2 : 3-normal ratio as expected. Opaque-2 segregates were lighter than the normal type and smaller in size. A mottled phenotype of opaque-2 maize observed in the Philippines yellow endersperm. In some varieties opaque-2 maize was very susceptible to the ear and kernel rot disease. No. 5(female) and opaque-2(male). Selectlon of a double mutant of waxy and opaque-2 by using the iodine technique and electric lamp was discussed. opaque-2 and floruy-2 were not allels. Different percentage of seed set were observed in the segregation of aewx crossed with opaque-2. An unusual gametophytie relationship was involved in a cross between Glutinous.

  • PDF

Characteristics of Opaque Endosperm Originated from a Rice Cultivar ′Pokhareli Mashino′ (벼품종 ″Pokhareli Mashino′에서 유래된 Opaque형질의 배유특성)

  • ;Mun-Hue Heu
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.34 no.2
    • /
    • pp.155-162
    • /
    • 1989
  • This experiment was conducted to investigate the endosperm characteristics of an opaque rice which was derived from an Indica cultivar Pokhareli Mashino. Grain apperance of opaque rice looked similar to the waxy grain, while the blue-color response to the iodine solution was similar to non-waxy endosperm. The shape of starch granules was alike each other, but their size were different each other with the smallest of the opaque rice. Their cristaline structure of starch granules were A type. The content of total protein and most of the amino-acids of opaque rice was about 1.5 times of other varieties. Alkali digestibility of the opaque rice was very low. Total water uptake and hydration rate of opaque rice was similar to non-waxy variety Tongil. Amylogram characteristics such as viscosity, setback and consistency of opaque rice revealed medium value between. waxy and non-waxy rice.

  • PDF

A COMPARATIVE STUDY OF THE PHYSICOCHEMICAL PROPER TIES AND BOND STRENGTH TO METAL BETWEEN THE REGULAR OPAQUE POWDER AND CORE POWDER (도재소부전장금관용 Opaque 분말과 도재전장관용 core 분말의 물리화학적 성질 및 금속과의 결합력에 대한 비교연구)

  • Lim, Jang-Seop;Chung, Chang-Mo;Jeon, Young-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.1
    • /
    • pp.144-164
    • /
    • 1997
  • The purpose of this study were to investigate the chemical composition, mean particle size, linear thermal expansion coefficient and metal-bonding strength of the regular opaque powder and core powder. In this study, 4 types of ceramic powders, namely Duceram Jacket Opaque powder, Duceram Opaque powder, Vita Hi-Ceram powder, Vita VMK Paint On-88 powder were used. Chemical composition was evaluated by EDS(Energy Dispersive X-ray Spectrophotometer, Oxford QX-2000, England), particle size was measured by MALVERN Instruments(MALVERN Instruments SB. OC., U.S.A.. ad linear thermal expansion coefficient was measured by dilatometer(Motoyama, Japan). Bond strength was measured by the Universal tsting machine(Istron Co., Ltd., U.S.A.). The Results were as follows : 1. Through recognition of the relative difference in chemical composition between the core powder and the regular opaque powder, the difference in the proportion of $Al_2O_3$ in each type of material is demonstrated ; Duceram Jaket Opaque powder : 30.16%, Duceram Opaque powder : 16.60%, Vita Hi-Ceram : 63.64%, Vita VMK Paint-On 88 : 16.16%. 2. There was no significant difference in the proportion of metal-bonding materials between the core powder and the regular opaque powder. 3. In the regular opaque powder, alkaline materials were incoporated in order to increase the coefficient of thermal expansion. 4. In the particle size analysis, there was no significant difference in mean particle size or in the particle size distribution between the core powder and the regular opaque powder. 5. In the thermal expansion test for temperature range of $25-600^{\circ}C$, the regular opaque powder had higher coefficient of thermal expansion than that of core powder. 6. In the 4 point flexural bending test, there was no statistically significant difference in the mean bond strength between the core powder and the opaque powder among the Duceram products.

  • PDF

Thickness and translucency of opaque shade composite resin for masking effect (배경 색조 차단 목적의 불투명 복합 레진의 두께와 반투명도)

  • Baek, Kyung-Won;Kim, Sung-Joon
    • The Journal of the Korean dental association
    • /
    • v.49 no.4
    • /
    • pp.203-210
    • /
    • 2011
  • The aims of this study were to evaluate the adequate thickness of opaque resins for situations such as an oral black cavity and discolored tooth structure, as well as the translucency of each opaque material at various thicknesses. Six opaque-shade composite resins (Z-350 OA3, Amelogen Universal A2O, Esthet-X A2O, Esthet-X A4O, Charmfil UO and Aelite Universal OA3) were prepared in metal molds with a hole of 8 mm in diameter and various thicknesses (0.5mm, 1.0mm, 1.5mm, 2.0mm, 2.5mm, 3.0 mm and 4.0mm). Four backgrounds (white tile, black tile, C4 shade porcelain and opaque resin itself) were used to determine the translucency parameter (between black and white backgrounds). and to mimic a black oral cavity (between black and opaque resin backgrounds) and a discolored tooth structure (between C4 and opaque resin backgrounds). Color measurements were made by a colorimeter to determine the CIELAB values of each specimen with each background and to calculate the translucency parameter and ${\Delta}E^*$ value difference among the specimens on the backgrounds. The translucency parameter and ${\Delta}E^*$ obtained between black and opaque resin backgrounds decreased in similar pattern as thickness increased. A C4 background was masked by resin thicknesses of 0.5-1.0mm, while a black background required thicknesses of 1.0-2.0mm. Adequate knowledge about differences in the optical character like translucency of the materials used is essential, together with the accumulated experience of the individual clinician.

OPACITY AND MASHING EFFECT OF THE OPAQUE SHADE COMPOSITE RESINS (Opaque shade 복합레진의 opacity와 배경 색상 차단 능력의 평가)

  • Park, Su-Jung;Hwang, Yun-Chan;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.4
    • /
    • pp.356-364
    • /
    • 2007
  • The purpose of this study was to assess the background color-interceptive ability ana opacity of opaque shade composites (Universal composite, Filtek Z350, Charisma, Clearfil ST, Palpaque Estelite, Esthet-X, and Metafil Flo). Twenty four background specimens (diameter 5.5 mm, thickness 3.0 mm) with Root dentin Mustard (Bisco, Schaumburg, IL, USA) were made. The CIE $L^*a^*b^*$ value of background specimens was measured by a spectrophotometer (Spectrolino, GretagMacbeth, Regensdorf, Switzerland). Three specimens in every group were filled on the background specimens. The surface color of samples was measured by a spectrophotometer in 3.0 mm and every thickness to 0.5 mm while grinding. The color difference in the background color along with 3.0 mm specimen gauged the masking effect in each thickness while grinding and polishing. The opacity was calculated in 1 mm thick specimens. The opacity was in the decreasing order of Clearfil ST, Metafil Flo, Filtek Z350, Palpaque Estelite, Universal composite, Charisma, and Esthet-X (p < 0.05). As the thickness get reduced, $L^*$ value showed decreasing, $a^*$ increasing tendency. The surface color difference between pair of the 3.0 mm thick specimen and after grinding in same opaque resin was above 3.3 except Clearfil ST and Metafil Flo. The color difference (${\Delta}E^*$) between pair of background specimen and opaque resin built-up specimen showed more than 10.0 regardless kinds and thickness. The variance in opacity characteristics and color of the opaque composites is dependent upon manufacturer. When using the opaque resin, the optical properties of each material must be considered as well as cavity.

Effects of Opaque-2 Corn on the Body Weight of Rats ("오페이크 2" 옥수수가 흰쥐의 생체중에 미치는 영향)

  • Bong-Ho Chae;Keun-Yong Park
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.22 no.1
    • /
    • pp.16-19
    • /
    • 1977
  • Feeding test was conducted to determine the values of opaque-2 corn selected from opaque-2 conversion program at the Crop Experiment Station, Suwon. At the end of 24 days of experiment, the average gain of body weight of white rats fed on opaque-2 corn was 40.2 grams, that of the rats on normal corn, 31.4 grams, 1.3 fold difference. The growth rate of rats expressed by regression coefficients indicated that the effects of opaque-2 corn was greater than that of normal corn.

  • PDF

SPECTROPHOTOMETRIC ANALYSIS OF THE INFLUENCE OF METAL SUBSTRATE ON THE COLOR OF CERAMIC (금속하부구조물이 도재의 색조에 미치는 영향에 대한 분광측색분석)

  • Lee Su-Ok;Woo Yi-Hyung;Choi Dae-Gyun;Kwon Keung-Rok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.2
    • /
    • pp.148-159
    • /
    • 2003
  • Statement of problem Metal-ceramic restorations have been used extensively by dental clinicians for nearly 40 years. Strength an functional ability of metal-ceramic restorations are proved to be satisfying, However esthetics and biocompatibility of metal alloy which is used in metal-ceramic restoration is not ideal. Using pure gold as an alternative, have advantage of esthetics, biocompatibility over conventional metal alloy. But there had been little article which studied on the color effect of pure gold on fual porcelain color. Purpose The purpose of this study was to spectrophotometrically evaluate the difference between color of metal alloy(Au-Pt, Ni-Cr) and pure gold, during color masking procedure with opaque porcelain and to analyze the differences, Material and Methods Three types of metal - base metal(Ni-Cr), high gold alloy(Au-Pt), pure gold(GES) - specimen were fabricated 1cm in diameter. Four steps were established - after finishing, after pre-coditioning, after application of first opaque porcelain(0.08mm in thickness), after application of second opaque porcelain(0.15mm in thickness)- and tested color with spectrophotometer every each steps and analyzed with $CIEL^*a^*b^*$ color order system. One-Way ANOVA test was used to and out if there were significant differences between groups tested and Shaffe multiple comparison was used to identify where the differences were. Results 1. After finishing and pre-conditioning, pure gold(GES) group showed most high values in $L^*,a^*,b^*$. 2. After application of first opaque porcelain(0.08mm in thickness), after application of second opaque porcelain(0.15mm in thickness), pure gold(GES) group showed the least difference in $L^*,a^*,b^*$ values and the lowest ${\Delta}E$ value(${\Delta}E$=0.63). 3. After application of first opaque porcelain and after application of second opaque porcelain differences that were significant (P<0.05) between groups were found only in $a^*$ values. 4. Base metal alloy group showed the lowest $a^*$ value in test after application of first opaque porcelain and the highest value in test after application of first opaque porcelain Conclusion Pure gold group and high gold group showed higher $a^*$ values than base metal group when tested after 0.08mm thickness of opaque porcelain was applied and pure gold group showed much similar $L^*,a^*,b^*$ values between 0.08mm thickness and 0.15mm thickness of opaque porcelain. This meant that pure gold was more easily masked by opaque porcelain than the other two groups.

An Experimental Study on Effect on Debonding Strength of Metal-porcelain by Painting Method of Opaque Porcelain (Opaque 도재의 도포 방법에 따른 금속-도재의 결합강도에 미치는 영향에 관한 실험적 연구)

  • Kim, Sa-Hak
    • Journal of Technologic Dentistry
    • /
    • v.22 no.1
    • /
    • pp.39-47
    • /
    • 2000
  • This study is the know the difference bond strength according to painting method of Opaque porcelain. Among Porcelain powder for Porcelain, Noritake powder, Bonding agent 1 class and metal are selected as Base metal alloy. And painting method of Opaque porcelain is divided by 4 groups : PG, WG, NG and DG. Also it is to manufacture 24 sheets of Specimen by 6 each every method and to measure Crack-initiation Strength of Metal-porcelain and it is to observe it by Scanning electron microscope. I come to get a conclusion as follows. 1. As for Debonding strength of every experiment groups, it showed that WS group which executed Wash bake had highest value, 44.25MPa and NG group which used Normal powder had value, 42.11MPa and DG group which used Bonding agent had value, 35.88MPa and PG group which used Paste opaque had value, 35.39MPa. 2. In four painting methods of Opaque porcelain, PG group, WG group, NG group and DG group, there is no significant difference statistically in Crack-initiation Strength. 3. As a result of observing fracture surface with Scanning electron microscope, it was showde that PG group remained a lot of particle of porcelain on the surface of metal than WG group, NG group and DG group.

  • PDF

The Effect of Repeated Firing on the Color Difference of a Metal-Ceramic System with Different Porcelain Powder (다른 특성을 가지는 도재가 반복소성에 따라 색조변화에 미치는 영향)

  • Hwang, Jae-Sun
    • Journal of Technologic Dentistry
    • /
    • v.31 no.1
    • /
    • pp.23-36
    • /
    • 2009
  • The goal of esthetic restoration is to achieve morphologic, optical, and biologic acceptance. Creation of a natural looking ceramic restoration, which blends harmoniously with surrounding dentition, is not always achieved. A successful color match is an important aspect of any esthetic dental restoration. Since natural enamel has inherent translucency, it is important that ceramic restorations reproduce the translucency and color of the natural teeth. However, the final color match of porcelain crowns to adjacent natural dentition remains some problem. Difficulties related to color matching arise from the structural differences that exist between metal ceramic crowns and natural teeth, the limited range of available ceramic shades, inadequate shade guides, different types of metal alloys, repeated firing, the condensation technique, and varying compositions of ceramic materials. Many factors contribute to the esthetic success of dental restoration: optical properties such as color and its elements of hue, value, and chroma; translucency and opacity; light transmission and scattering; and metamerism and fluorescence. The purpose of this study was to determine the color changes of metal-ceramic system with different veneering porcelain powder after repeated firing. The objectives of this in vitro study were to measure the lightness($L^*$), chromaticity($a^*$), chromaticity($b^*$), chroma($C^*$), hue(h), reflectance(%), color difference(${\Delta}E$). The following conclusions were obtained: 1. An increase in the number of firings resulted in decrease in lightness($L^*$) but increase in chromacticity($a^*$) with all porcelain. After the second sintering resulted in decrease in chromacticity($b^*$) with opaque-dentin porcelain and dentin porcelain but in increase with enamel porcelain and translucency porcelain. And after the second sintering resulted in decrease in chroma($C^*$) with opaque-dentin porcelain and dentin porcelain, but on the whole side in decrease with enamel porcelain and translucency porcelain. 2. After the second firing, a increase in the number of firings resulted in decrease reflectance(%) in all wavelength. 3. There were noticeable color differences(${\Delta}E$) between first sintering and multiple firings(dentin porcelain: 5.29~8.15, opaque-dentin porcelain: 4.83~8.2, enamel porcelain: 8.93~13.15, translucency porcelain: 9.37~12.91), but the color difference(${\Delta}E$) after second sintering were down to 4.87 in all porcelain. 4. Given the NBS Criteria, a 'trace' was not found this study but a 'slight' was found 2-3, 3-5 in dentin porcelain, 2-3 in opaque-dentin porcelain, 3-5, 5-10 in enamel porcelain and translucency porcelain, a 'noticeable' was 2-5, 3-10, 5-10 in dentin porcelain and opaque-dentin porcelain, 2-3, 2-5, 3-10 in enamel porcelain 2-3, 3-10 in translucency porcelain, an 'appreciable' was 1-2, 1-3, 2-10 in dentin porcelain 1-2, 1-3, 2-10, 3-10 in opaque-dentin porcelain, 2-10 in enamel porcelain, 2-5, 2-10 in translucency porcelain, a 'much' was 1-5, 1-10 in dentin porcelain and opaque-dentin porcelain, 1-2, 1-3, 1-5 in enamel porcelain 1-2, 1-3, 1-5, 1-10 in translucency porcelain, a 'very much' was 1-10 in enamel porcelain.

  • PDF

EFFECT OF TWO OPAQUING TECHNIQUES ON METAL-CERAMIC BOND STRENGTH (Opaque 도재의 도포 방법이 치과용 합금과 도재간의 결합 강도에 미치는 영향)

  • Jang, Il-Seong;Lee, Sun-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.3
    • /
    • pp.475-488
    • /
    • 1996
  • The opaque porcelain layer of porcelain-fused-to-metal(PFM) restoration is critical for the success of PFM restoration because it is the first layer placed over the treated alloy. But, the methods of opaquing technique have not been confirmed. Usually, the one layer method and two layer method have been used for the application of opaque porcelain. In the past, alloys with porcelain veneers which have been used successfully have contained various precious metals. Recent increase in the cost of precious metals stimulates considerable interest in nonprecious alloys. Although nickel-chromium alloys and nickel-chromium-beryllium alloys have been widely used, the use of cobalt-chromium alloys would be gradually increased with elimination of any potential risk of nickel-related allergic responses and/or beryllium-related toxic responses. This investigation examined one- and two-layer opaque porcelain applications to determine the effect on the bond strength of titanium added cobalt-chromium metal ceramic alloy. Bond strength of Ceramco II porcelain to titanium added cobalt-chromium alloy(2Dentitan) and gold-platinum-palladium alloy(Degudent H) were evaluated by direct shear bond strength test with Instron universal testing machine. The results were as follows; 1. When the mean shear bond strength of each experimental group were compared in $0.25cm^2$ unit area, the titanium added cobalt-chromium alloy/two layer method exhibited the greatest strength(79.7kg), followed by titanium added cobalt-chromium alloy/one layer method(76.2kg), gold-platinum-palladium alloy/two layer method(71.4kg), gold-platinum-palladium alloy/one layer method(64.2kg). 2. No significant differences in bond strength were recorded between the two opaquing techniques for gold-platinum-palladium alloy and titanium added cobalt-chromium alloy. 3. No significant differences in bond strength were recorded between the gold-platinum-palladium alloy and the titanium added cobalt-chromium alloy.

  • PDF