• Title/Summary/Keyword: oneM2M standards

Search Result 148, Processing Time 0.029 seconds

ANISOTROPY CONSTANTS OF $(Sm_{0.5}RE_{0.5})Fe_{11}Ti$ COMPOUNDS (RE=RARE EARTH)

  • Kim, H.T.;Kim, Y.B.;Park, W.S.;Kim, C.S.;Kim, T.K.;Jin, Han-Min
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.5
    • /
    • pp.683-686
    • /
    • 1995
  • Using by the x-ray diffractometry(XRD), the thermomagnetic analysis(TMA), a scanning electron microscopy (SEM-EDX), we knew that the $(Sm_{0.5}RE_{0.5})Fe_{11}Ti$ (RE=Ce,Pr,Nd,Sm,Gd,Tb) compounds were formed to tetragonal $ThMn_{12}$-type structure having a uniaxial magnetocrystalline anisotropy with easy magnetization c-axis. The intrinsic magnetic properties of those were determined by fitting the two magnetization curves of experimental and calculation magnetization. The anisotropy constant $K_{1}$ of this compounds was in the range of $1.75\;-\;9.2\;MJ/m^{3}$ and approximately one order higher than $K_{2}$. $SmFe_{11}Ti$ had the highest anisotropy of $K_{1}\;=\;9.2\;MJ/m^{3}$, $K_{2}\;=\;0.4\;MJ/m^{3}$ and ${\mu}_{o}H_{A}=\;19.8\;T$ among the compounds, substitution of any other rare earth elements for Sm decreased magnetocrystalline anisotropy.

  • PDF

IoT-enabled Solutions for Tour Photography Services

  • Jeong, Isu;Baek, Seungwoo;An, Eunsol;Kim, Yujin;Choi, Jiwoo;Yun, Jaeseok
    • Journal of the Korea Society of Computer and Information
    • /
    • v.25 no.5
    • /
    • pp.127-135
    • /
    • 2020
  • In this paper, we propose an IoT-enabled solution for tour photography services with small-size investment and resources in the travel and tourism industries, being able to impact on economic, social, and cultural values. An IoT-enabled camera is developed based on an open hardware and software platform complying with oneM2M, which can make traditional embedded systems oneM2M-compliant devices due to a middleware solution called TAS (thing adaptation software). IoT cameras deployed around photo zones in a tour site could be remotely controlled via an IoT gateway with a Web-based application on a smartphone. Users would perform a pan and tilt camera control if they want and then take and download a perfect photo picture (even though they are away from the tour site). We expect that the proposed solution will promote the deployment IoT-enabled technologies in tour and travel industries which are important parts of the tertiary sector.

Device Management Standards of IoT and YANG based Management Information Design (loT 장치 관리 표준 및 YANG 기반의 관리 정보 설계)

  • Choi, Soo-Gil;Choi, Mi-Jung
    • Annual Conference of KIPS
    • /
    • 2015.04a
    • /
    • pp.228-230
    • /
    • 2015
  • 차세대 성장동력으로 각광받고 있는 사물인터넷은 국제 표준 혐의체인 oneM2M의 주도 아래 표준화가 진행중이다. 사물인터넷은 모든 사물이 연결되는 초연결성이라는 점과 연산 능력, 메모리, 배터리 등에 많은 한계를 갖는 제약 많은 장치가 대상이라는 두가지 큰 특징이 있다. 본 논문에서는 oneM2M의 장치 관리 표준에 대해서 설명한다. 또한 사물인터넷의 기술적 이슈를 해결하기 위해 등장한 CoAP 기반의 LWM2M 표준 기술을 소개하고 이를 데이터 모델링 언어인 YANG 기반의 장치관리 정보 설계를 제안한다.

Study on the Defects Detection in Composites by Using Optical Position and Infrared Thermography

  • Kwon, Koo-Ahn;Park, Hee-Sang;Choi, Man-Yong;Park, Jeong-Hak;Choi, Won Jae
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.2
    • /
    • pp.130-137
    • /
    • 2016
  • Non-destructive testing methods for composite materials (e.g., carbon fiber-reinforced and glass fiber-reinforced plastic) have been widely used to detect damage in the overall industry. This study detects defects using optical infrared thermography. The transient heat transport in a solid body is characterized by two dynamic quantities, namely, thermal diffusivity and thermal effusivity. The first quantity describes the speed with thermal energy diffuses through a material, whereas the second one represents a type of thermal inertia. The defect detection rate is increased by utilizing a lock-in method and performing a comparison of the defect detection rates. The comparison is conducted by dividing the irradiation method into reflection and transmission methods and the irradiation time into 50 mHz and 100 mHz. The experimental results show that detecting defects at 50 mHz is easy using the transmission method. This result implies that low-frequency thermal waves penetrate a material deeper than the high-frequency waves.

A $LN_2$-cooled, Broadband cw CO Laser (액체질소 냉각형광대역 cw CO 레이저)

  • Kim, Y.P.;Choi, J.W.;Won, J.W.
    • Proceedings of the KIEE Conference
    • /
    • 1989.07a
    • /
    • pp.667-671
    • /
    • 1989
  • The CO laser is one of powerful light source for laser magnetic resonance spectroscopy in the mid-infrared region of the spectrum because of its wideband operational characteristics. In this work, a liquid nitrogen cooled cw CO laser is developed to allow broad-band operation from 5 to 8 ${\mu}m$. The design details will be presented.

  • PDF

A Study on the Rice growing water-management System based on IoT (IoT 기반 벼농사 생장 물 관리 시스템 연구)

  • Nam, Kang-Hyun
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.10
    • /
    • pp.989-994
    • /
    • 2016
  • This study was conducted the management of a water level through the water sensor, the waterline and the drain applied to the rice paddy. The gateway transfers the information to oneM2M(: Machine to Machine) platform of IoT(: Internet of Thing) standards to the height of the water level sensor information through the LoRa connection. Depending on the water level requested by the IoT platform, the gateway is to On or Off waterline or drain motor switch and send the information of the water level sensor. IoT platform performs the intelligent application function according to the condition of the water level.

Development of an Isotope-Dilution Liquid Chromatography/Mass Spectrometric Method for the Accurate Determination of Acetaminophen in Tablets

  • Shin, Hyun-Ju;Kim, Byung-Joo;Lee, Joon-Hee;Hwang, Eui-Jin
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.12
    • /
    • pp.3663-3667
    • /
    • 2010
  • Acetaminophen (N-acetyl-p-aminophenol) is one of the most popular analgesic and antipyretic drugs. An isotope dilution mass spectrometric method based on LC/MS was developed as a candidate reference method for the accurate determination of acetaminophen in pharmaceutical product. After spiking an isotope labeled acetaminophen (acetyl-$^{13}C_2$, $^{15}N$-acetaminophen) as an internal standard, tablet extracts were analyzed by LC/MS in a selected reaction monitoring (SRM) mode to detect ions at m/z $152{\rightarrow}110$ and m/z $155{\rightarrow}111$ for acetaminophen and acetyl-$^{13}C_2$, $^{15}N$-acetaminophen, respectively. The repeatability and reproducibility of the developed ID/LC-MS method were tested for the validation and assessment of metrological quality of the method.

A Study of Morphology and Pattern Analysis in Magnoliae Cortex (후박(厚朴)의 외.내부형태 및 이화학패턴연구)

  • Lee, Guem-San;Kim, Jung-Hoon;Choi, Go-Ya;Kang, Dae-Hoon;Hwang, Sung-Yeoun;Jeong, Seung-Il;Kim, Hong-Jun;Ju, Young-Sung
    • The Korea Journal of Herbology
    • /
    • v.23 no.4
    • /
    • pp.21-29
    • /
    • 2008
  • Objectives: To determine the standards for discrimination of Magnoliae Cortex, the experiment of specific external-internal characters and the physicochemical pattern analysis were performed. Methods: External characteristics was observed using a stereoscope. Paraffin-mediated sectioned materials were stained by Ju's method. Physicochemical patterns of materials were analyzed using HPLC. Results: 1. Botanical characteristics: Magnolia officinalis had one seed and a white flower, while M. obovata had two seeds and a white flower. Machilus thunbergii had berry and spherical fruits and yellowish green panicles. 2. External characteristics: M. officinalis and M obovata were dark and thick. M. officinalis was gray brown and greasy while M. obovata was light-gray, less oily and smoothly sectioned. Machilus thunbergii was thin and relatively light or yellow-brown, coarsely sectioned and faintly specific scents. 3. Internal characteristics: The bast parts of M. officinalis and M. obovata were commonly wider than Machilus thunbergii The cork cortex of M. officinalis was $10{\sim}mg/L$ cell layers with many oil cells, while that of M. obovata was $4{\sim}7$ cell layers with less oil cells. Machilus thunbergii's xylem which consisted of ring-shaped cambium at 1st and 2nd part was occupied in large portion. 4. Physicochemical pattern: Both M. officinalis and M. obovata involved honokiol and magnolol. All kinds of M. officinalis involved Magnatriol B but one kind of M. ovobata and all of Machilus thunbergii didn't. Machilus thunbergii showed different pattern of chromatogram from that of 2 species above. Conclusions: These results could be used as standards for discrimination of Magnoliae Cortex and as the method of objectification in medicinal herbs giving the basic resource for bioactivity research.

  • PDF

A Study on the Area and Clearances around Patient Bed Space in Intensive Care Unit (중환자실 병상주변공간의 면적과 간격에 관한 연구)

  • Lee, Hyunjin;Kwon, Soonjung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.25 no.3
    • /
    • pp.47-55
    • /
    • 2019
  • Purpose: This study tries to propose the dimensions and area related to patient bed and surroundings in ICU considering nurses' observation and medical care. Methods: Literature survey, 11 Case studies, some Interviews with nurses and measuring of medical equipments' dimension in ICU have been mobilized in order to deepen the ICU bed area standards. Results: 0.3m clearance between head wall and patient bed is necessary for emergency cases. The minimum distance at the foot of the bed should not be less than 0.9m for EMR cart and medical tray. The clear floor area of one bed and surroundings in open ward is $10.2m^2(3m{\times}3.4m)$. In a single-bed patient room, the minimum clear floor area is $16.0m^2(4m{\times}4m)$. Considering the control of cross infection in ICU, Single bed patient room is recommended. Implications: The result of this study can be applied to the design of ICU and legislation of ICU standard.

Accuracy Assessment for Measuring Surface Figures of Large Aspheric Mirrors

  • Kim, Young-Soo;Ahn, Ki-Beom;Park, Kwi-Jong;Moon, Il-Kweon;Yang, Ho-Soon
    • Journal of the Optical Society of Korea
    • /
    • v.13 no.2
    • /
    • pp.178-183
    • /
    • 2009
  • At the time that the Keck-I 10m telescope was constructed in 1993, the era of Very Large Telescopes (VLTs) was opened. Now thirteen VLTs are in operation, and the largest of the monolithic mirrors is 8.4 m in diameter. Such monolithic mirrors are mostly aspheric and require high accuracies on the surface figures, reaching up to the diffraction limit. At present, next generation telescopes, Giant telescopes, are being developed. One is the GMT (Giant Magellan Telescope) whose size is 25.4 m in diameter. The primary mirror consists of seven segments figuring elliptical shapes on the surface. The surrounding six segments are off-axis and the edges are steep, as the fast focal ratio is adopted. It means that testing of the mirrors is a challenging task. In this paper, testing methods for the GMT primary mirror are reviewed, and accuracy of measuring devices is assessed. Results and discussions follow.