• Title/Summary/Keyword: oneM2M standards

Search Result 148, Processing Time 0.032 seconds

Estimation of Dynamic Properties of Steel Liquid Storage Tank by Shaking Table Test (진동대 실험에 의한 강재 액체저장탱크의 동특성 분석)

  • Choi, Hyoung Suk;Park, Dong Uk;Kim, Sung Wan;Kim, Jae Min;Baek, Eun Rim
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.21 no.4
    • /
    • pp.153-161
    • /
    • 2017
  • Liquid storage tank is one of the major infrastructures and generally used to store gases, drinking and utilizing water, dangerous fluids, fire water and so on. According to the recent reports and experiences, the tank structures are damaged in many earthquakes due to their low energy dissipating capacity. Therefore, many researchers have been tried to know the dynamic properties of the tanks including liquids. However, vary limited experimental studies are carried out using relatively small tank models. In this study, a series of shaking table tests are performed with maximum 2 m cubic rectangular liquid storage tanks made of steel to measure the natural frequency and estimate damping coefficient of impulsive and convective mode of the tanks. Especially, the damping values under different shapes and excitation methods are estimated by logarithmic decrement method and half power band-pass method and compared with current design code and standards such as ASCE 7, Eurocode 8 and NZS. Test results show that the impulsive mode damping is around 2% which is proposed by general standards and codes but the impulsive mode damping is 0.13% average that is slightly lower than the code recommendation.

A Basic Study on The Architectural Characteristic of the Group Home in Japan (일본 그룹 홈의 건축적 특징에 관한 기초연구)

  • Yang, Yoon-Sil;Kim, Tae-Il
    • Korean Institute of Interior Design Journal
    • /
    • v.23 no.4
    • /
    • pp.248-256
    • /
    • 2014
  • According to data from the national office of Statistics Korea and Ministry of Health and Welfare, as the elderly population increases, the dementia elderly population continues to increase and its future population growth rate is expected to be even faster. In particular, the Dementia Management Act has been in effect since February 2012, and active efforts has been made for a policy for the dementia management. The purpose of this study is to establish standards on building plans based on the appropriate scale and spatial configuration on facilities planning for the elderly with dementia. Specifically, the basic data were collected with a request for a total of 103 points on the basis of a database of group homes in the survey managed by the Japan Association of Group Homes. Specific information of the research includes the management body of facilities operation, scale of the facilities, number of units and configuration of personal living space, and the collected survey data and drawings were statistically proceed and analyzed using the SPSS WIN 20.0. analysis results are summarized as follows. first, most of the group homes come to the small size of the 1-2 story home ; the approximate number of units is one or two per home, and each unit consists of nine rooms. second, a number of group homes with the building area of $300m^2$ have the U-shaped arrangement which is advantageous in the extension and facilities maintenance. In conclusion, this study is to be the fundamental data for judgments that can be used to establish standards for the facilities for the dementia elderly whose population continues to increase. In addition, further study is necessary to establish suitable design conditions of our country.

Reliability evaluation of steel truss bridge due to traffic load based on bridge weigh-in-motion measurement

  • Widi Nugraha;Indra Djati Sidi;Made Suarjana;Ediansjah Zulkifli
    • Structural Monitoring and Maintenance
    • /
    • v.9 no.4
    • /
    • pp.323-336
    • /
    • 2022
  • Steel truss bridge is one of the most widely used bridge types in Indonesia. Out of all Indonesia's national roads, the number of steel truss bridges reaches 12% of the total 17,160 bridges. The application of steel truss bridges is relatively high considering this type of bridge provides advantages in the standardization of design and fabrication of structural elements for typical bridge spans, as well as ease of mobilization. Directorate of Road and Bridge Engineering, Ministry of Works and Housing, has issued a standard design for steel truss bridges commonly used in Indonesia, which is designed against the design load in SNI 1725-2016 Bridge Loading Standards. Along with the development of actual traffic load measurement technology using Bridge Weigh-in-Motion (B-WIM), traffic loading data can be utilized to evaluate the reliability of standard bridges, such as standard steel truss bridges which are commonly used in Indonesia. The result of the B-WIM measurement on the Central Java Pantura National Road, Batang - Kendal undertaken in 2018, which supports the heaviest load and traffic conditions on the national road, is used in this study. In this study, simulation of a sequences of traffic was carried out based on B-WIM data as a moving load on the Australian type Steel Truss Bridge (i.e., Rangka Baja Australia -RBA) structure model with 60 m class A span. The reliability evaluation was then carried out by calculating the reliability index or the probability of structural failure. Based on the analysis conducted in this study, it was found that the reliability index of the 60 m class Aspan for RBA bridge is 3.04 or the probability of structural failure is 1.18 × 10-3, which describes the level of reliability of the RBA bridge structure due to the loads from B-WIM measurement in Indonesia. For this RBA Bridge 60 m span class A, it was found that the calibrated nominal live load that met the target reliability is increased by 13% than stated in the code, so the uniform distributed load will be 7.60 kN/m2 and the axle line equivalent load will be 55.15 kN/m.

Study on Thermal Comfort and Indoor Air Quality in the Classroom with System Air-conditioner and Ventilation System for Cooling Loads (시스템에어컨과 환기시스템 설치 강의실에서 냉방시 열쾌적성 및 실내공기질 연구)

  • Noh Kwang-Chul;Jang Jae-Soo;Oh Myung-Do
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.1 s.244
    • /
    • pp.57-66
    • /
    • 2006
  • The experimental and the numerical study was performed on the comparison of thermal comfort(TC) and indoor air quality(IAQ) in the lecture room for cooling loads when the operating conditions are changed. PMV value and $CO_2$ concentration of the lecture room were measured and compared with the numerical results. The numerical results showed a good agreement with the experimental one and then the numerical tool was used to analyze thermal comfort and IAQ for a couple of operating conditions. As a result it was found that the increment of the discharge angle of system air-conditioner makes TC uniformity worse, but rarely affects IAQ. Also TC and IAQ were hardly affected by the variation of the discharge airflow. Finally it turned out that TC is merely affected by the increment of the ventilation airflow, but the average $CO_2$ concentration can be satisfied with Japanese IAQ standards of classrooms when the ventilation airflow is more than $800m^3/h$ in this study.

Object oriented linking of GIS to assess ground water quality in Dharmapuri district, India

  • Devi, K.K.Manjula;M, Prashanthi Devi.;Kumar, D. Nandha;Balasubramanian, S
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.1439-1441
    • /
    • 2003
  • The World Health Organisation has identified ‘Fluorosis’as a serious bone disease caused by groundwater. Though the fluoride content in groundwater is a natural phenomenon, when the permissible limit of fluoride is exceeded the consequences may be fatal. This study is identified areas of high fluoride content in the Dharmapuri district of India, which is one of the major districts severely affected by fluorosis (WHO). The approach to this problem is by using GIS as a tool to locate areas of high risk. Ground Water samples collected from 35 randomly located wells (open / bore wells) in the district were analysed for fluoride content. The results were compared with the standards of WHO (World Health Organisation ), ICMR (Indian Council of Medical Research ), BIS (Bureau of Indian Standard) and PHE (Public Health Engineering) and interpolated using IDW and spline methods using Arcview GIS 3.2 a. A computer based automated information system was developed in Arcview Avenue 3.2a, so as to enable the user to visit the risk areas at his desktop and to remediate measures as and when required.

  • PDF

Study on PM10, PM2.5 Reduction Effects and Measurement Method of Vegetation Bio-Filters System in Multi-Use Facility (다중이용시설 내 식생바이오필터 시스템의 PM10, PM2.5 저감효과 및 측정방법에 대한 연구)

  • Kim, Tae-Han;Choi, Boo-Hun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.48 no.5
    • /
    • pp.80-88
    • /
    • 2020
  • With the issuance of one-week fine dust emergency reduction measures in March 2019, the public's anxiety about fine dust is increasingly growing. In order to assess the application of air purifying plant-based bio-filters to public facilities, this study presented a method for measuring pollutant reduction effects by creating an indoor environment for continuous discharge of particle pollutants and conducted basic studies to verify whether indoor air quality has improved through the system. In this study conducted in a lecture room in spring, the background concentration was created by using mosquito repellent incense as a pollutant one hour before monitoring. Then, according to the schedule, the fine dust reduction capacity was monitored by irrigating for two hours and venting air for one hour. PM10, PM2.5, and temperature & humidity sensors were installed two meters front of the bio-filters, and velocity probes were installed at the center of the three air vents to conduct time-series monitoring. The average face velocity of three air vents set up in the bio-filter was 0.38±0.16 m/s. Total air-conditioning air volume was calculated at 776.89±320.16㎥/h by applying an air vent area of 0.29m×0.65m after deducing damper area. With the system in operation, average temperature and average relative humidity were maintained at 21.5-22.3℃, and 63.79-73.6%, respectively, which indicates that it satisfies temperature and humidity range of various conditions of preceding studies. When the effects of raising relatively humidity rapidly by operating system's air-conditioning function are used efficiently, it would be possible to reduce indoor fine dust and maintain appropriate relative humidity seasonally. Concentration of fine dust increased the same in all cycles before operating the bio-filter system. After operating the system, in cycle 1 blast section (C-1, β=-3.83, β=-2.45), particulate matters (PM10) were lowered by up to 28.8% or 560.3㎍/㎥ and fine particulate matters (PM2.5) were reduced by up to 28.0% or 350.0㎍/㎥. Then, the concentration of find dust (PM10, PM2.5) was reduced by up to 32.6% or 647.0㎍/㎥ and 32.4% or 401.3㎍/㎥ respectively through reduction in cycle 2 blast section (C-2, β=-5.50, β=-3.30) and up to 30.8% or 732.7㎍/㎥ and 31.0% or 459.3㎍/㎥ respectively through reduction in cycle 3 blast section (C-3, β=5.48, β=-3.51). By referring to standards and regulations related to the installation of vegetation bio-filters in public facilities, this study provided plans on how to set up objective performance evaluation environment. By doing so, it was possible to create monitoring infrastructure more objective than a regular lecture room environment and secure relatively reliable data.

A Study on Engineering Characteristics of Load Reducing Material EPS (도로성토하중경감재 EPS의 공학적 특성에 관한 연구)

  • Jang, Myeong-Sun;Cheon, Byeong-Sik;Im, Hae-Sik
    • Geotechnical Engineering
    • /
    • v.12 no.2
    • /
    • pp.59-70
    • /
    • 1996
  • The EPS has the unit weight of only 20~30kg/m3 and is used as one of the methods of reducing road embankment loads. Parts of it's applications are for backfill materials of structures like abutment, retaining wall, etc., to reduce horizontal earth pressure and for banking materials to secure the safety of settlement and bearing capacity by minimizing the stress Increment. However, the Korean Standards (KS) has not yet proposed any testing method for use of EPS as a engineering banking material. Only its testing and quality ordinance as a heat insulation material has been standardized. Therefore, in Korea, EPS is used as banking material without any systematic testing data as a civil engineering material. In this point of view, this paper deals with the engineering characteristics of EPS through many laboratory tests on strength, strain, absorption, and creep. from the results achived through tests, this paper proposes the enactment of a suitable quality testing ordinance and the criteria of unconfined design strength of EPS for use as engineering material.

  • PDF

Distributions and Origins of PM10 in Jeollabuk-do from 2010 to 2015 (2010~2015년 전라북도 도시대기 PM10의 특성)

  • Cho, Byeongsu;Song, Mijung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.33 no.3
    • /
    • pp.251-264
    • /
    • 2017
  • Recently, Jeollabuk-do has been reported as a province where the $PM_{10}$concentration is one of the highest levels in South Korea. To explore the characteristics and origins of the $PM_{10}$in Jeollabuk-do, we present one of the first long-term datasets including a statistical analysis of $PM_{10}$concentrations obtained from six cities in the province from 2010 to 2015. During the entire periods, the mean hourly $PM_{10}$concentration was $49.3{\mu}g/m^3$, which correspond to the annual ambient air quality standards for $PM_{10}$in South Korea, and the annual $PM_{10}$concentration of each city showed a similarity in year-to-year variations. In the monthly variation of $PM_{10}$, the $PM_{10}$concentrations showed a maximum value in May that was one of the top levels among the provinces of Korea while the concentrations were dramatically decreased in August showing one of the lowest levels among the provinces in Korea. For the diurnal variation of $PM_{10}$, the $PM_{10}$concentration was enhanced during the rush hours together with gaseous species of $NO_2$, and CO. When the high concentrations of $PM_{10}$were observed (the highest 10% of the $PM_{10}$mass contribution), temperature and relative humidity were low. Using HYSPLIT backward trajectories and cluster analysis for the high $PM_{10}$concentrations, we found that the pollution plumes were transported mainly from China.

Analysis of Daily Milking Flow in Holstein Dairy Cow Using the LactoCorder (전자식유량계를 활용한 홀스타인 젖소의 비유형질 분석)

  • Cho, Kwang-Hyun;Choi, Jun-Pyo;You, Byung-Wha;Lee, Deuk-Hwan;Kong, Hong-Sik;Park, Kyung-Do;Lee, Hak-Kyo
    • Journal of Animal Science and Technology
    • /
    • v.51 no.4
    • /
    • pp.265-272
    • /
    • 2009
  • A total of 486 milk records were collected from 16 diary farms in Imsil-gun, Jeollabuk-do. Results obtained were as follows: The average 3MG (amount of milk within the first three minute) was 7.44 kg and 55% of total milk yield was produced within 3 min. The average of SPL (% of foam in milk) was 33.93% and the average of MNG (strip yield) was 0.14 kg, which was less than 1% of total milk yield. The averages of HMF (highest milk flow), HMG (maximum milk flow rate in one minute) and DMHG (average milk flow in the main milking phase) were 3.03 kg/min, 2.94 kg/min and 2.05 kg/min, respectively and the average milking speed in Imsil-gun was slower than other regions. The average of tS500(time to reach 0.5 kg/min at beginning) was 0.23min (about 14 seconds) and that of tMGG (duration of the total milking) was 7.75min. The average tMBG (duration of the dry milking phase) was 0.58 min (35 seconds) and that of tMNG (duration of the stripping phase) was 0.42min (14 seconds). The averages of ELHMF (electrical conductivity at highest milk flow) and ELAP (beginning peak level of the electrical conductivity) were 6.81 mS/cm and 7.58 mS/cm, respectively. The average of ELMAX (maximum electrical conductivity) was 7.48 mS/cm and that of ELAD (beginning peak difference of the electrical conductivity) was 0.61 mS/cm. While the total milk yields for DMHG, tMHG (duration of the main milking phase), tPL (duration of the plateau phase), tAB (duration of the descending phase) and tMGG were positively correlated (0.35~0.54), those for tMBG and SPL were negatively correlated (-0.11 and -0.27). As the DMHG increased, tMHG, tPL, tAB, tMGG and SPL decreased. While the cows with higher electrical conductivity at the beginning of milking had less somatic cell counts, cows with higher electrical conductivity after the peak of milk yield had more somatic cell counts. The results of this experiment indicated that through milking based on milking and lactating standards and the regular checking of milking status, the qualities of milk and milk yields could be improved.

Comparison of sample storage containers for the analysis of volatile organic compounds (VOC) (휘발성유기물(VOC) 분석을 위한 시료보관 용기의 비교)

  • Kim, Seokyung;Kim, Dalho
    • Analytical Science and Technology
    • /
    • v.35 no.3
    • /
    • pp.116-123
    • /
    • 2022
  • Polymer bags, metallic canisters, and glass bottles have been used as containers for analyzing the volatile organic compounds (VOCs) in air. In this study, various sampling containers were compared to investigate the short-term stability of VOCs, that is, from the time they are sampled to the time they are analyzed. Polyvinyl fluoride (PVF), polypropylene (PP), polyester aluminum (PE-Al) bags, canisters, and glass bottles were used as sample containers. A 100 nmol/mol standard gas mixture of benzene, toluene, ethylbenzene, m-xylene, styrene, and o-xylene was used for the VOC comparison. Changes in the concentrations of samples stored for 10~20 day in each container were measured using a thermal desorption-gas chromatograph-flame ionization detector (TD-GC-FID). As a result, VOCs stored in a canister and two kinds of amber glass bottles have shown immaterial decreases in concentration in one week, and more than 80 % of the initial concentration was maintained for two weeks. In the case of polymer bags, the concentration of all VOCs, except benzene and toluene, were remarkably decreased below 70% of the initial concentration in one day. Particularly, ethylbenzene, xylene, and styrene have shown dramatic decreases in concentration below 30 % of the initial concentration in all polymer bags in one day.