Journal of the Earthquake Engineering Society of Korea
/
v.21
no.4
/
pp.153-161
/
2017
Liquid storage tank is one of the major infrastructures and generally used to store gases, drinking and utilizing water, dangerous fluids, fire water and so on. According to the recent reports and experiences, the tank structures are damaged in many earthquakes due to their low energy dissipating capacity. Therefore, many researchers have been tried to know the dynamic properties of the tanks including liquids. However, vary limited experimental studies are carried out using relatively small tank models. In this study, a series of shaking table tests are performed with maximum 2 m cubic rectangular liquid storage tanks made of steel to measure the natural frequency and estimate damping coefficient of impulsive and convective mode of the tanks. Especially, the damping values under different shapes and excitation methods are estimated by logarithmic decrement method and half power band-pass method and compared with current design code and standards such as ASCE 7, Eurocode 8 and NZS. Test results show that the impulsive mode damping is around 2% which is proposed by general standards and codes but the impulsive mode damping is 0.13% average that is slightly lower than the code recommendation.
According to data from the national office of Statistics Korea and Ministry of Health and Welfare, as the elderly population increases, the dementia elderly population continues to increase and its future population growth rate is expected to be even faster. In particular, the Dementia Management Act has been in effect since February 2012, and active efforts has been made for a policy for the dementia management. The purpose of this study is to establish standards on building plans based on the appropriate scale and spatial configuration on facilities planning for the elderly with dementia. Specifically, the basic data were collected with a request for a total of 103 points on the basis of a database of group homes in the survey managed by the Japan Association of Group Homes. Specific information of the research includes the management body of facilities operation, scale of the facilities, number of units and configuration of personal living space, and the collected survey data and drawings were statistically proceed and analyzed using the SPSS WIN 20.0. analysis results are summarized as follows. first, most of the group homes come to the small size of the 1-2 story home ; the approximate number of units is one or two per home, and each unit consists of nine rooms. second, a number of group homes with the building area of $300m^2$ have the U-shaped arrangement which is advantageous in the extension and facilities maintenance. In conclusion, this study is to be the fundamental data for judgments that can be used to establish standards for the facilities for the dementia elderly whose population continues to increase. In addition, further study is necessary to establish suitable design conditions of our country.
Steel truss bridge is one of the most widely used bridge types in Indonesia. Out of all Indonesia's national roads, the number of steel truss bridges reaches 12% of the total 17,160 bridges. The application of steel truss bridges is relatively high considering this type of bridge provides advantages in the standardization of design and fabrication of structural elements for typical bridge spans, as well as ease of mobilization. Directorate of Road and Bridge Engineering, Ministry of Works and Housing, has issued a standard design for steel truss bridges commonly used in Indonesia, which is designed against the design load in SNI 1725-2016 Bridge Loading Standards. Along with the development of actual traffic load measurement technology using Bridge Weigh-in-Motion (B-WIM), traffic loading data can be utilized to evaluate the reliability of standard bridges, such as standard steel truss bridges which are commonly used in Indonesia. The result of the B-WIM measurement on the Central Java Pantura National Road, Batang - Kendal undertaken in 2018, which supports the heaviest load and traffic conditions on the national road, is used in this study. In this study, simulation of a sequences of traffic was carried out based on B-WIM data as a moving load on the Australian type Steel Truss Bridge (i.e., Rangka Baja Australia -RBA) structure model with 60 m class A span. The reliability evaluation was then carried out by calculating the reliability index or the probability of structural failure. Based on the analysis conducted in this study, it was found that the reliability index of the 60 m class Aspan for RBA bridge is 3.04 or the probability of structural failure is 1.18 × 10-3, which describes the level of reliability of the RBA bridge structure due to the loads from B-WIM measurement in Indonesia. For this RBA Bridge 60 m span class A, it was found that the calibrated nominal live load that met the target reliability is increased by 13% than stated in the code, so the uniform distributed load will be 7.60 kN/m2 and the axle line equivalent load will be 55.15 kN/m.
Transactions of the Korean Society of Mechanical Engineers B
/
v.30
no.1
s.244
/
pp.57-66
/
2006
The experimental and the numerical study was performed on the comparison of thermal comfort(TC) and indoor air quality(IAQ) in the lecture room for cooling loads when the operating conditions are changed. PMV value and $CO_2$ concentration of the lecture room were measured and compared with the numerical results. The numerical results showed a good agreement with the experimental one and then the numerical tool was used to analyze thermal comfort and IAQ for a couple of operating conditions. As a result it was found that the increment of the discharge angle of system air-conditioner makes TC uniformity worse, but rarely affects IAQ. Also TC and IAQ were hardly affected by the variation of the discharge airflow. Finally it turned out that TC is merely affected by the increment of the ventilation airflow, but the average $CO_2$ concentration can be satisfied with Japanese IAQ standards of classrooms when the ventilation airflow is more than $800m^3/h$ in this study.
Devi, K.K.Manjula;M, Prashanthi Devi.;Kumar, D. Nandha;Balasubramanian, S
Proceedings of the KSRS Conference
/
2003.11a
/
pp.1439-1441
/
2003
The World Health Organisation has identified ‘Fluorosis’as a serious bone disease caused by groundwater. Though the fluoride content in groundwater is a natural phenomenon, when the permissible limit of fluoride is exceeded the consequences may be fatal. This study is identified areas of high fluoride content in the Dharmapuri district of India, which is one of the major districts severely affected by fluorosis (WHO). The approach to this problem is by using GIS as a tool to locate areas of high risk. Ground Water samples collected from 35 randomly located wells (open / bore wells) in the district were analysed for fluoride content. The results were compared with the standards of WHO (World Health Organisation ), ICMR (Indian Council of Medical Research ), BIS (Bureau of Indian Standard) and PHE (Public Health Engineering) and interpolated using IDW and spline methods using Arcview GIS 3.2 a. A computer based automated information system was developed in Arcview Avenue 3.2a, so as to enable the user to visit the risk areas at his desktop and to remediate measures as and when required.
Journal of the Korean Institute of Landscape Architecture
/
v.48
no.5
/
pp.80-88
/
2020
With the issuance of one-week fine dust emergency reduction measures in March 2019, the public's anxiety about fine dust is increasingly growing. In order to assess the application of air purifying plant-based bio-filters to public facilities, this study presented a method for measuring pollutant reduction effects by creating an indoor environment for continuous discharge of particle pollutants and conducted basic studies to verify whether indoor air quality has improved through the system. In this study conducted in a lecture room in spring, the background concentration was created by using mosquito repellent incense as a pollutant one hour before monitoring. Then, according to the schedule, the fine dust reduction capacity was monitored by irrigating for two hours and venting air for one hour. PM10, PM2.5, and temperature & humidity sensors were installed two meters front of the bio-filters, and velocity probes were installed at the center of the three air vents to conduct time-series monitoring. The average face velocity of three air vents set up in the bio-filter was 0.38±0.16 m/s. Total air-conditioning air volume was calculated at 776.89±320.16㎥/h by applying an air vent area of 0.29m×0.65m after deducing damper area. With the system in operation, average temperature and average relative humidity were maintained at 21.5-22.3℃, and 63.79-73.6%, respectively, which indicates that it satisfies temperature and humidity range of various conditions of preceding studies. When the effects of raising relatively humidity rapidly by operating system's air-conditioning function are used efficiently, it would be possible to reduce indoor fine dust and maintain appropriate relative humidity seasonally. Concentration of fine dust increased the same in all cycles before operating the bio-filter system. After operating the system, in cycle 1 blast section (C-1, β=-3.83, β=-2.45), particulate matters (PM10) were lowered by up to 28.8% or 560.3㎍/㎥ and fine particulate matters (PM2.5) were reduced by up to 28.0% or 350.0㎍/㎥. Then, the concentration of find dust (PM10, PM2.5) was reduced by up to 32.6% or 647.0㎍/㎥ and 32.4% or 401.3㎍/㎥ respectively through reduction in cycle 2 blast section (C-2, β=-5.50, β=-3.30) and up to 30.8% or 732.7㎍/㎥ and 31.0% or 459.3㎍/㎥ respectively through reduction in cycle 3 blast section (C-3, β=5.48, β=-3.51). By referring to standards and regulations related to the installation of vegetation bio-filters in public facilities, this study provided plans on how to set up objective performance evaluation environment. By doing so, it was possible to create monitoring infrastructure more objective than a regular lecture room environment and secure relatively reliable data.
The EPS has the unit weight of only 20~30kg/m3 and is used as one of the methods of reducing road embankment loads. Parts of it's applications are for backfill materials of structures like abutment, retaining wall, etc., to reduce horizontal earth pressure and for banking materials to secure the safety of settlement and bearing capacity by minimizing the stress Increment. However, the Korean Standards (KS) has not yet proposed any testing method for use of EPS as a engineering banking material. Only its testing and quality ordinance as a heat insulation material has been standardized. Therefore, in Korea, EPS is used as banking material without any systematic testing data as a civil engineering material. In this point of view, this paper deals with the engineering characteristics of EPS through many laboratory tests on strength, strain, absorption, and creep. from the results achived through tests, this paper proposes the enactment of a suitable quality testing ordinance and the criteria of unconfined design strength of EPS for use as engineering material.
Journal of Korean Society for Atmospheric Environment
/
v.33
no.3
/
pp.251-264
/
2017
Recently, Jeollabuk-do has been reported as a province where the $PM_{10}$concentration is one of the highest levels in South Korea. To explore the characteristics and origins of the $PM_{10}$in Jeollabuk-do, we present one of the first long-term datasets including a statistical analysis of $PM_{10}$concentrations obtained from six cities in the province from 2010 to 2015. During the entire periods, the mean hourly $PM_{10}$concentration was $49.3{\mu}g/m^3$, which correspond to the annual ambient air quality standards for $PM_{10}$in South Korea, and the annual $PM_{10}$concentration of each city showed a similarity in year-to-year variations. In the monthly variation of $PM_{10}$, the $PM_{10}$concentrations showed a maximum value in May that was one of the top levels among the provinces of Korea while the concentrations were dramatically decreased in August showing one of the lowest levels among the provinces in Korea. For the diurnal variation of $PM_{10}$, the $PM_{10}$concentration was enhanced during the rush hours together with gaseous species of $NO_2$, and CO. When the high concentrations of $PM_{10}$were observed (the highest 10% of the $PM_{10}$mass contribution), temperature and relative humidity were low. Using HYSPLIT backward trajectories and cluster analysis for the high $PM_{10}$concentrations, we found that the pollution plumes were transported mainly from China.
A total of 486 milk records were collected from 16 diary farms in Imsil-gun, Jeollabuk-do. Results obtained were as follows: The average 3MG (amount of milk within the first three minute) was 7.44 kg and 55% of total milk yield was produced within 3 min. The average of SPL (% of foam in milk) was 33.93% and the average of MNG (strip yield) was 0.14 kg, which was less than 1% of total milk yield. The averages of HMF (highest milk flow), HMG (maximum milk flow rate in one minute) and DMHG (average milk flow in the main milking phase) were 3.03 kg/min, 2.94 kg/min and 2.05 kg/min, respectively and the average milking speed in Imsil-gun was slower than other regions. The average of tS500(time to reach 0.5 kg/min at beginning) was 0.23min (about 14 seconds) and that of tMGG (duration of the total milking) was 7.75min. The average tMBG (duration of the dry milking phase) was 0.58 min (35 seconds) and that of tMNG (duration of the stripping phase) was 0.42min (14 seconds). The averages of ELHMF (electrical conductivity at highest milk flow) and ELAP (beginning peak level of the electrical conductivity) were 6.81 mS/cm and 7.58 mS/cm, respectively. The average of ELMAX (maximum electrical conductivity) was 7.48 mS/cm and that of ELAD (beginning peak difference of the electrical conductivity) was 0.61 mS/cm. While the total milk yields for DMHG, tMHG (duration of the main milking phase), tPL (duration of the plateau phase), tAB (duration of the descending phase) and tMGG were positively correlated (0.35~0.54), those for tMBG and SPL were negatively correlated (-0.11 and -0.27). As the DMHG increased, tMHG, tPL, tAB, tMGG and SPL decreased. While the cows with higher electrical conductivity at the beginning of milking had less somatic cell counts, cows with higher electrical conductivity after the peak of milk yield had more somatic cell counts. The results of this experiment indicated that through milking based on milking and lactating standards and the regular checking of milking status, the qualities of milk and milk yields could be improved.
Polymer bags, metallic canisters, and glass bottles have been used as containers for analyzing the volatile organic compounds (VOCs) in air. In this study, various sampling containers were compared to investigate the short-term stability of VOCs, that is, from the time they are sampled to the time they are analyzed. Polyvinyl fluoride (PVF), polypropylene (PP), polyester aluminum (PE-Al) bags, canisters, and glass bottles were used as sample containers. A 100 nmol/mol standard gas mixture of benzene, toluene, ethylbenzene, m-xylene, styrene, and o-xylene was used for the VOC comparison. Changes in the concentrations of samples stored for 10~20 day in each container were measured using a thermal desorption-gas chromatograph-flame ionization detector (TD-GC-FID). As a result, VOCs stored in a canister and two kinds of amber glass bottles have shown immaterial decreases in concentration in one week, and more than 80 % of the initial concentration was maintained for two weeks. In the case of polymer bags, the concentration of all VOCs, except benzene and toluene, were remarkably decreased below 70% of the initial concentration in one day. Particularly, ethylbenzene, xylene, and styrene have shown dramatic decreases in concentration below 30 % of the initial concentration in all polymer bags in one day.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.