• Title/Summary/Keyword: one-way measurement

Search Result 535, Processing Time 0.026 seconds

Comparison of polymer-based temporary crown and fixed partial denture materials by diametral tensile strength

  • Ha, Seung-Ryong;Yang, Jae-Ho;Lee, Jai-Bong;Han, Jung-Suk;Kim, Sung-Hun
    • The Journal of Advanced Prosthodontics
    • /
    • v.2 no.1
    • /
    • pp.14-17
    • /
    • 2010
  • PURPOSE. The purpose of this study was to investigate the diametral tensile strength of polymer-based temporary crown and fixed partial denture (FPD) materials, and the change of the diametral tensile strength with time. MATERIAL AND METHODS. One monomethacrylate-based temporary crown and FPD material (Trim) and three dimethacrylate-based ones (Protemp 3 Garant, Temphase, Luxtemp) were investigated. 20 specimens (${\phi}\;4\;mm\;{\times}\;6\;mm$) were fabricated and randomly divided into two groups (Group I: Immediately, Group II: 1 hour) according to the measurement time after completion of mixing. Universal Testing Machine was used to load the specimens at a cross-head speed of 0.5 mm/min. The data were analyzed using one-way ANOVA, the multiple comparison Scheff$\acute{e}$ test and independent sample t test ($\alpha\;=\;0.05$). RESULTS. Trim showed severe permanent deformation without an obvious fracture during loading at both times. There were statistically significant differences among the dimethacrylate-based materials. The dimethacrylate-based materials presented an increase in strength from 5 minutes to 1 hour and were as follows: Protemp 3 Garant (23.16 - 37.6 MPa), Temphase (22.27 - 28.08 MPa), Luxatemp (14.46 - 20.59 MPa). Protemp 3 Garant showed the highest value. CONCLUSION. The dimethacrylate-based temporary materials tested were stronger in diametral tensile strength than the monomethacrylate-based one. The diametral tensile strength of the materials investigated increased with time.

A Study on the Efficiency Measurement of Regional Maritime Affairs and Fisheries Office by DEA Method (DEA에 의한 지방해양수산청 효율성 비교 분석에 관한 연구)

  • Lee, Nam-Kyu;Kim, Si-Hwa
    • Journal of Navigation and Port Research
    • /
    • v.32 no.1
    • /
    • pp.73-80
    • /
    • 2008
  • The purpose of this paper is to measure the productive efficiency and competitive strength of Regional Maritime Affairs and Fisheries Office using the DEA. Using EMS(Efficiency Measurement System) which is LP solver, quantifies in one way or another a "distance" to the efficient frontier of the technology. An input oriented measure quantifies the input reduction which is necessary to become efficient holding the output constant. Symmetrically, an output oriented measure quantifies the necessary to become efficient holding the inputs constant. A non-oriented measure quantifies necessary improvements when both inputs and outputs can be improved simultaneously. According to the analysis result of the DEA method, inefficient Regional Maritime Affairs and Fisheries Office should recommend benchmarking reference Regional Maritime Affairs and Fisheries Office in order to enhance the productive efficiency of port administration and a public institution. Besides data on productive efficiency serves as a tool for policy-makers at all levels of activity and is essential for improving the efficiency with which the various systems operate.

Difference of Proprioceptive Sense at Elbow Joint According to Measurement Methods (팔굽관절에서 측정방법에 따른 고유수용성감각 차이)

  • Lee, Jung-Ah;Kim, Duk-Hwa;Shin, Hwa-Kyung;Choi, Kyu-Hwan;Kwon, Oh-Yun
    • Physical Therapy Korea
    • /
    • v.10 no.3
    • /
    • pp.63-70
    • /
    • 2003
  • The purpose of this study was to compare the difference of joint position sense between measurements. Fourteen healthy male subjects were recruited for this study. The elbow joint position senses were measured using angle reproduction test. The elbow joint position sense was assessed with three experimental conditions: ipsilateral reproduction test in open-chain condition, contralateral reproduction test in open-chain condition, ipsilateral reproduction test with weight in open-chain condition and ipsilateral reproduction test in closed-chain condition. The angular difference between stimulus position and the reproduced position (angular error) was calculated in all testing conditions to examine the accuracy of the joint position sense. One way ANOVA was used to compare the error angles in all experimental conditions. The error angles between measurements were significantly different in elbow joint. The error angles was smallest in ipsilateral reproduction test with weight in open-chain condition and was greatest in the contralateral reproduction test in open-chain condition. Findings of this study indicate that testing methods, types of task, existence of resistance should be considered in clinical assessment for the joint position sense.

  • PDF

A Study of the Visual Image by Pattern Making of Jeans (청바지 패턴 제작에 따른 시각적 이미지 연구)

  • Kim, Kyeong-Hee;So, Yeon-Jung
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.33 no.10
    • /
    • pp.1541-1551
    • /
    • 2009
  • This study gives guidelines to pattern designing by supplying various images of the transformed shape of jeans with the location of the waistline and the pants silhouette. For this study, 9 kinds of sample cloths (100% cotton denim) were designed considering the laying measurement of the jeans with the location of the waistline and the pants silhouette. The images of each sample were evaluated after the measurement of the completed samples. Clothing and textiles specialists used a semantic differential scale as the evaluation method of the images. For the statistical analysis of the data, one way Anova and Duncan test were adopted using the SPSS 12.0 program. The results of this study are as follows: 1. The visual image by the location of waistline and the change of the pants silhouette is composed of 3 factors (attraction, fashion and comfort factors) of which the attraction factor is the most important factor. 2. The visual image is positive when the location of the waistline is in the low waist position. It is attractive, fashionable, and comfortable. The visual image is negative when the location of the waistline is in the position of the natural waist. 3. The visual image is attractive when the pants silhouette is a boot-cut and fashionable when the pants silhouette are skinny. The straight-cut is comfortable but the visual image is negative. 4. There is no correlation between visual image by the location of the waistline and the change of the pants silhouette.

Evaluation of the repeatability and matching accuracy between two identical intraoral spectrophotometers: an in vivo and in vitro study

  • Kim, Hee-Kyung
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.3
    • /
    • pp.252-258
    • /
    • 2018
  • PURPOSE. The purpose of this study was to evaluate the repeatability and matching accuracy between two identical intraoral spectrophotometers. MATERIALS AND METHODS. The maxillary right central incisor, canine, and mandibular left central incisor of each of 30 patients were measured using 2 identical intraoral spectrophotometers with different serial numbers (EasyShade V). The color of each shade tab from 3 shade guides (VITA 3D-Master) was also determined with both devices. All measurements were performed by a single operator. Statistical analyses were performed to verify the repeatability, accuracy, and the differences between the devices with paired t-tests, one-way ANOVA, and intra-class correlation coefficients (ICCs) (${\alpha}=.05$). RESULTS. A high level of measurement repeatability (ICC>0.90) among $L^*$, $a^*$, and $b^*$ color components was observed within and between devices (P<.001). Intra-device matching agreement rates were 80.00% and 81.11%, respectively, while inter-device matching agreement rate was 51.85%. ANOVA revealed no significant different color values within each device, while paired t-test provided significant different color values between both devices. The CIEDE2000 color differences between both devices were $2.28{\pm}1.61$ ${\Delta}E_{00}$ for in-vivo readings. Regarding the clinical matching accuracy of both devices, ${\Delta}E_{00}$ values between teeth and matching shade tabs were $3.05{\pm}1.19$ and $2.86{\pm}1.02$, respectively. CONCLUSION. Although two EasyShade V devices with different serial numbers show high repeatability of CIE $L^*$, $a^*$, and $b^*$ measurements, they could provide different color values and shade for the same tooth.

Comparison of the Effects of Abdominal Bracing Exercises and Abdominal Hollowing Exercises on Lumbar Flexibility and Pulmonary Function in Healthy Adults

  • Kim, Kyung-bin;Chon, Seung-chul
    • Physical Therapy Korea
    • /
    • v.24 no.4
    • /
    • pp.68-76
    • /
    • 2017
  • Background: Abdominal bracing exercise (ABE) and abdominal hollowing exercise (AHE) improve the lumbar flexibility and pulmonary function in various patients, yet the efficacy of ABE or AHE have not yet been evaluated. Objects: The purpose of this study was to compare the lumbar flexibility and pulmonary function during both ABE and AHE in healthy adults. Methods: The study included 40 healthy adults, who were randomly divided into the experimental group and control group, each with 20 subjects. All subjects performed ABE (experimental group) and AHE (control group). The lumbar flexibility such as trunk flexion test (sitting and standing position) and schober test and pulmonary function such as the spirometer including forced vital capacity (FVC) and force expiratory volume in one second ($FEV_1$) and chest circumference measurement (middle and lower chest) were measured, respectively. Two-way repeated analysis of variance was used to compare the lumbar flexibility and pulmonary function, respectively. Results: No significant effects of lumbar flexibility were observed on trunk flexion test from the sitting position (P=.478) and standing position (P=.096) in the ABE than in the AHE. However, the length of ABE was longer significantly than it of AHE (P=.024). No significant effects of lung function were observed on the FVC (P=.410) and $FEV_1$ (P=.072) in the ABE group than in the AHE group. And also, no significant effects of chest circumference measurement were observed on the inspiration (P=.468) and expiration (P=.563) in middle chest circumference and inspiration (P=.104) and expiration (P=.346) in lower chest circumference. Conclusion: This study indicated that the ABE is only more effective in lumbar flexibility by lumbar length difference than AHE in healthy adults.

A COMPARATIVE ANALYSIS WITH RESONANCE FREQUENCY ACCORDING TO VARIOUS SIMULATED BONE DEFECTS (다양한 가상 골 결함에 따른 공진 주파수의 비교 분석)

  • Kim Sang-Mi;Park Chan-Jin;Yi Yang-Jin;Chang Beom-Seok;Cho Lee-Ra
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.4
    • /
    • pp.487-497
    • /
    • 2005
  • Purpose: Resonance frequency analysis (RFA) , a non-invasive technique for the clinical measurement of implant stability, was investigated. Peri-implant bony defect may contribute to implant failure. This in vitro study evaluated the resonance frequencies according to various bony defects and determined whether the directional bone defect can affect the value of frequency analysis. Material and Method: Fifteen 3.75 mm in diameter and 10 mm in length, machined self-tapping implant future were used. Twelve types of bone defects that have different horizontal and vertical dimensions were simulated. Embedded implants were attached to the dental surveyor. Then, the transducer was connected with the implant fixture and the ISQ value was measured at four different directions. Two-way analysis of variance and post hoc $Sch\`{e}ffe'$ test were performed at the 95% significance level. Results: The control group showed the highest ISQ value and 5 thread-$360^{\circ}$ group had the lowest one. As the vertical exposure of implants in each angle was increased, the ISQ value was decreased. Although the horizontal exposure in each thread was increased, the ISQ value was not significantly decreased. Conclusion : Although the simulated defect type was different from each other, the ISQ value was similar among groups.

A Study on Influencing Factors in BWIM System and Its Field Applicability (BWIM시스템의 현장 적용성 및 영향인자에 관한 연구)

  • Yoo, Dong Gyun;Kyung, Kab Soo;Lee, Sung Jin;Lee, Hee Hyun;Jeon, Jun Chang
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.4
    • /
    • pp.251-262
    • /
    • 2014
  • It has been considered that factors affecting accuracy of the estimated weight of moving vehicle by BWIM system are vehicle and bridge characteristics, and measurement conditions which is related to the strain curve. In this study, theoretical review and field test were performed to evaluate effect of these factors in BWIM system. From these evaluations, we proposed a way to improve accuracy of the estimated vehicle information in BWIM system. As the results, it was known that girder type and continuity of spans in bridge are not governing factor, but its plane shape gives large influence on accuracy of the estimated vehicle information. In addition, running speed of vehicle has also large effect on the estimated accuracy of axle distance if the distance between second and third axles is short. However, weight sum of the two axles can be estimated reasonably by assuming them as one axle.

The Relationships between Age, Socio-ecoomic Status and Clothing Behavior of Korean Men (성인 남자의 연령 및 사회.경제적 지위와 의복행동과의 상관 연구)

  • 고애란
    • Journal of the Korean Home Economics Association
    • /
    • v.25 no.1
    • /
    • pp.1-10
    • /
    • 1987
  • The purpose of this study was to investigate the relationships between demographic variables and seven aspects of clothing behavior of adult males, and to attempt to develop the measurement of men's clothing behavior. Age was ranked by five gradation (20∼60 ages) and socio-economic status was divided into three categories (high, middle, low) based on the subjects' education, occupation and economic status. Six aspects of clothing comfort, satisfaction, status symbol, conformity, fashion interest and clothing acceptance I were assessed with Koh's, Chung's and Lee's questionnaires. Clothing acceptance by line-drawing of clothing syles representing different levels of formality for occasions designed to measure the awareness of appropriate clothing category of business suits. The questionnaires in this study were administered to a sample of men living in Seoul. The sample was drawn by the random-cluster sampling method. The data from 362 respondants were analysed. To determine the internal validity of clothing behavior mesurement, factor analysis was computed, whereas to determine the reliability, Cronbach's alpha was calculated. The statistical methods adopted were correlation, one-way ANOVA, and multiple regression. The results obtained in this study were as follows: 1) As for clothing behavior instruments, items dealing with status symbol and fashion nterest were proved to be satisfactory as a measurement of adult males. Eight factors emerged on clothing acceptance Ⅱ, most of which were representing unappropriate clothing choice for occasion. 2) Demographic variables were significantly related to the adult males' clothing behavior. (1) Age was positively related to clothing conformity but negatively to fashion interest. (2) Socio-economic status was positively related to clothing satisfaction, status symbol, and fashion interest but negatively to clothing confort. (3) When age was controlled, socio-economic status was negatively related to comfort in 40∼50s age group only, and negatively related to clothing conformity in 20∼30s age group only. (4) Four subscales of clothing acceptance Ⅱ representing unappro-priate clothing practice for selected occasions were negatively related to age and/or socio-economic status.

  • PDF

Cortical and cancellous bone thickness on the anterior region of alveolar bone in Korean: a study of dentate human cadavers

  • Kim, Heung-Joong;Yu, Sun-Kyoung;Lee, Myoung-Hwa;Lee, Hoon-Jae;Kim, Hee-Jung;Chung, Chae-Heon
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.3
    • /
    • pp.146-152
    • /
    • 2012
  • PURPOSE. The cortical bone thickness on the anterior region is important for achieving implant stability. The purpose of this study was to examine the thickness of the cortical and cancellous bones on the anterior region of the maxilla and mandible. MATERIALS AND METHODS. Twenty-five cadaver heads were used (16 male and 9 female; mean death age, 56.7 years). After the long axis of alveolar process was set up, it was measured in 5 levels starting from 2 mm below the cementoenamel junction (L1) at intervals of 3 mm. All data was analysed statistically by one-way ANOVA at the .05 significance level. RESULTS. The cortical bone thickness according to measurement levels in both the labial and lingual sides increased from L1 to L5, and the lingual side below L3 was significantly thicker than the labial side on the maxilla and mandible. In particular, the labial cortical bone thickness in the maxilla was the thinnest compared to the other regions. The cancellous bone thickness according to measurement levels increased from L1 to L5 on the maxilla, and on the mandible it was the thinnest at the middle level of the root. CONCLUSION. For implant placement on the anterior region, a careful evaluation and full knowledge on the thickness of the cortical and cancellous bone are necessary, therefore, these results may provide an anatomic guideline to clinicians.