• 제목/요약/키워드: one-way measurement

검색결과 533건 처리시간 0.026초

압력센서 가압방식의 평균혈압 측정에 관한 연구 (Measurement of Noninvasive Mean Arterial Pressure using Tonometry Pressure Sensor)

  • 박미경;허영;강희정;김경철
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2006년도 하계종합학술대회
    • /
    • pp.859-860
    • /
    • 2006
  • We developed a cuffless and noninvasive measurement technique of blood pressure using tonometric pressure sensor. With observation that the maximum value of pulse pressure is not obtained at mean arterial pressure(MAP), we have figured out MAP based on the physiological characteristic including the elasticity of wrist tisse. Detecting only one part of the body and using only one device are quite advantageous over other BP measurement techniques. Our technique makes new way for the cuffless BP measurement.

  • PDF

Creepage Distance Measurement Using Binocular Stereo Vision on Hot-line for High Voltage Insulator

  • He, Wenjun;Wang, Jiake;Fu, Yuegang
    • Current Optics and Photonics
    • /
    • 제2권4호
    • /
    • pp.348-355
    • /
    • 2018
  • How to measure the creepage distance of an insulator quickly and accurately is a problem for the power industry at present, and the noticeable concern is that the high voltage insulation equipment cannot be measured online in the charged state. In view of this situation, we develop an on-line measurement system of creepage distance for high voltage insulators based on binocular stereo vision. We have proposed a method of generating linear structured light using a conical off-axis mirror. The feasibility and effect of two ways to solve the interference problem of strong sunlight have been discussed, one way is to use bandpass filters to enhance the contrast ratio of linear structured light in the images, and the other way is to process the images with adaptive threshold segmentation and feature point extraction. After the system is calibrated, we tested the measurement error of the on-line measurement system with a composite insulator sample. Experimental results show that the maximum relative error is 1.45% and the average relative error is 0.69%, which satisfies the task requirement of not more than 5% of the maximum relative error.

측정 자동화 구축을 위한 투영기의 치수오차 분석에 관한 연구 (A Study on Analysis of Dimensional Error of Projector for Formulations of Measurement Automation)

  • 최지선;김문기
    • 반도체디스플레이기술학회지
    • /
    • 제20권4호
    • /
    • pp.114-118
    • /
    • 2021
  • In this research, the dimensional error of the measured specimen according to the measurement method was analyzed for the length, angle, radius of curvature and diameter using a projector which is used in industry. One-way analysis was performed on each data tested 30 times using a statistical technique. Through the experiment, it was found that an error occurred in each data when measuring the length and radius of curvature according to the measurement method, and the null hypothesis that no error occurred when measuring the angle and length was established. Based on this experimental data, the automatic measurement when measuring the projector causes less measurement error, so automatic measurement is recommended when measuring a small product. Also, an optimal measuring method is suggested for securing reliability on formulations of measurement automation.

다수의 성과척도를 통합하는 방법의 적용사례 (Implementation of the Performance Information Integration Method for Multiple Performance measures)

  • 박창규
    • 경영과학
    • /
    • 제16권2호
    • /
    • pp.109-123
    • /
    • 1999
  • We have recognized that an organization should be viewed from a multifaceted perspective necessitating a sophisticated analytical and systematic approach to monitor and improve organizational performance. Although some performance measurement systems have been proposed and are currently being used in many organizations, no performance measurement system has presented a mechanism for integrating all of the information of performance measures in a way that considers relationships between them. This paper introduces the implementation of the performance information integration method(PIIM) which synthesizes all useful information of performance measures with consideration of the relationship and generates a single, global, organizational performance score. The PIIM was empirically validated by implementing in one of missouri Veterans Homes.

  • PDF

CT법을 이용한 진원도 측정 방법의 개선에 관한 연구 (A Study on the Improvement of Circularity Measurement Using Circular Test Method)

  • 주만식
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 1999년도 추계학술대회 논문집 - 한국공작기계학회
    • /
    • pp.446-451
    • /
    • 1999
  • A study for the roundness of machining center is classified into two ways. one is the way that progresses the roundness amending the parameter of machining center based on the measured value after the measurement of the roundness of machining center by means of a existing measuring device, another is the way that measures the roundness by remodeling the existing measuring device. The former is studied by pack hei jae team in Seoul university, the latter is studied by TSUTSUMI. Especially TSUTSUMI measures the roundness according to circular compensation after the insertion of developed measuring desire using a rotary encoder to the spindle of machining tool. We study how regulation velocity occuring with circular motion of machining center table influences the roundness after measuring the roundness using Circular Test method by a 2 dimention probe and a standard discus in this experiment.

  • PDF

CT법을 이용한 진원도 및 직각도 측정에 관한 연구 (A Study on the Measurement of Circularity and Perpendicularity Using Circular Test Method)

  • 주만식
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2000년도 춘계학술대회논문집 - 한국공작기계학회
    • /
    • pp.75-81
    • /
    • 2000
  • This study for the roundness and perpendicularity of machining center is classified into two ways. One is the way that progresses the roundness amending the parameter of machining center based on the measured value after the measurement of the roundness of machaning center by means of a existing measuring device, another is the way that measures the roundness by remodeling the existing measuring device. the former is studied by pack hei jae team in Seoul university, the later is studied by TSUTSUMI. Especially TSUTSUMI measures the roundness according to circular compensation after the insertion of developed measuring device using a rotary encoder to the spindle of machining tool. we study how regulation velocity occuring with circular motion of machining center table influences the roundness after measuring the roundness using Circular Test method by a 2 dimention probe and a standard discus in this experiment.

  • PDF

BcN에서 멀티미디어 서비스를 위한 RTP/RTCP의 QoS 측정방법 (QoS Measurement Method of RTP/RTCP for Multimedia Service in BcN)

  • 임재영;김정호
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2005년도 추계 종합학술대회 논문집
    • /
    • pp.611-615
    • /
    • 2005
  • 본 논문은 향후에 구축될 BcN망을 통해 제공될 멀티미디어 서비스를 위한 QoS를 보장하기 위해 서비스를 분류하고 풀질기준과 측정방법을 분석한다. 현재의 서비스 및 향후 BcN에서 제공될 서비스를 분류하였고, 종단간 품질기준을 살펴보고, 종단간 품질측정을 위한 측정방안으로서 호성공률, 패킷손실율, 단방향지연, 지터, R-값 등의 측정방법을 소개하였다.

  • PDF

雨水採取機가 雨水成分에 미치는 影響 (Effects of Rain Water Sampler on the Results of Analysis)

  • 李敏熙;韓義正;辛燦基;韓振錫
    • 한국대기환경학회지
    • /
    • 제3권2호
    • /
    • pp.53-61
    • /
    • 1987
  • Automatic and manual rain smaplers wre installed at the roof of National Institute of Environmental Research (NIER), and the rain sampling and measurement were conducted during the period April to August 31, 1987. The rain sampling and measurement were carried out in the following manners: The 1st : Acidity and conductivity were measured entirely by automatic rain sampler (continuous measurement) The 2nd : Acidity and conductivity wrer measured in the laboratory with the sample that was taken out of automatic rain sampler. The 3rd : Acidity and conductivity were measured in the laboratory with the sample that was taken out of manual rain sampler. Afterwards, those different measurement values were compared each other and the following conclusions were obtained: 1) The pH of the continous measurement by the automatic sampler was lower than that of the laboratory measurement, and it was reversed in case of the conductivity. 2) The significance was recognized at 5% risk ratio for the population mean of difference of the measurement values of the pH and conductivity from both samples. 3) The significance was not recognized at 5% risk ratio by the analysis of variance by one way layout for the pH and conductivity. 4) The significance was recognized at 5% risk ratio by the analysis of variance by two way layouts for the pH conductivity. 5) The significance was recognized at 5% rrisk ratio for the differences of the pH values obtained by oboth samplers, and no significance was recognized for conductivity. 6) In comparison of the measurement values from the two samplers were shown a good correlation for pH; correlation coefficient (r) = 0.63, and regression equation Y = 0.53X + 2.78. For conductivity, the correlation was also excellent; correlation coefficient (r) = 0.53 and regression equation Y = 0.63X + 5.65.

  • PDF

정밀 공작기계 안내면의 평행도 측정 (Parallelism Measurement for Guide Rails of Precision Machine Tools)

  • 황주호;박천홍;;김승우
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.792-795
    • /
    • 2005
  • The guide-ways of precision machine tools are one of important element of machine tools. It has usually a pair of surfaces for constraint of one direction with bearing. In the case of precision machine tools, non-contact bearing such as hydrostatic bearing and aerostatic bearing is adopted usually. In this case, profiles of rails has effect on straightness and the clearance of bearing has effect on stiffness of guide way, which changes to higher if clearance changes to smaller. The clearance is varied along moving table according to relative distance of pair of rails. The relative distance of pair of rail can be divided by three properties. First and second properties are straightness of each pair of rail and bearing pad. And, third is parallelism about pair of rails and pairs of bearing pad. There are several methods for measuring straightness of each surface such as reversal method, sequential two point method, and way straightness. These straightness measuring methods are always acquiring deviation of profile from eliminating linear fitted inclined line and don't have the information of parallelism. Therefore, to get the small clearance for high stiffness, the straightness of rail and bearing pad and parallelism about pair of rails and pair of bearing pads are measured for correction such as regrinding, reassembling and lapping. In this research, new and easy method for measuring parallelism of pair of rails is suggested. Two displacement probe and sensor stage, which is carry on the displacement sensor, are needed. The simulation and experiment was accomplished about pair of horizontal guide way to confirm the measurement of parallelism. And, the third probe is added to measure the straightness of each rails by sequential two point method. From the estimation of combined these two methods, it is confirmed that the profiles of a pairs of rails can be measured.

  • PDF

통계적 기법을 적용한 외도천의 단위유량도 제안 (A Proposal of Unit Hydrograph Using Statistical Analysis in Oedo Stream, Jeju)

  • 이준호;양성기;정우열
    • 한국환경과학회지
    • /
    • 제24권4호
    • /
    • pp.393-401
    • /
    • 2015
  • Rainfall-runoff model of Jeju Oedo Stream was used to compute the optimal unit hydrograph by HEC-HMS model that reflecting on watershed characteristics. Each rainfall event was comparatively analyzed with the actual flow measurement using Clark, Snyder and SCS synthetic methods for derived unit hydrograph. Subsequently, the null hypothesis was established as p-value for peak flow and peak time of each unit hydrograph by one-way ANOVA(Analysis of variance) was larger than significance level of 0.05. There was no significant difference in peak flow and peak time between different methods of unit hydrograph. As a result of comparing error rate with actual flow measurement data, Clark synthetic unit graph best reflected in Oedo Stream as compared to other methods, and error rate of Clark unit hydrograph was 0.02~1.93% and error rate at peak time was 0~2.74%.