• 제목/요약/키워드: one-way measurement

검색결과 533건 처리시간 0.023초

Measurement Scheme for One-Way Delay Variation with Detection and Removal of Clock Skew

  • Aoki, Makoto;Oki, Eiji;Rojas-Cessa, Roberto
    • ETRI Journal
    • /
    • 제32권6호
    • /
    • pp.854-862
    • /
    • 2010
  • One-way delay variation (OWDV) has become increasingly of interest to researchers as a way to evaluate network state and service quality, especially for real-time and streaming services such as voice-over-Internet-protocol (VoIP) and video. Many schemes for OWDV measurement require clock synchronization through the global-positioning system (GPS) or network time protocol. In clock-synchronized approaches, the accuracy of OWDV measurement depends on the accuracy of the clock synchronization. GPS provides highly accurate clock synchronization. However, the deployment of GPS on legacy network equipment might be slow and costly. This paper proposes a method for measuring OWDV that dispenses with clock synchronization. The clock synchronization problem is mainly caused by clock skew. The proposed approach is based on the measurement of inter-packet delay and accumulated OWDV. This paper shows the performance of the proposed scheme via simulations and through experiments in a VoIP network. The presented simulation and measurement results indicate that clock skew can be efficiently measured and removed and that OWDV can be measured without requiring clock synchronization.

효율적인 스트리밍 서비스를 위한 가용대역폭 측정 기법 (An Available Bandwidth Measurement Scheme for Efficient Streaming Service)

  • 이희상;이선헌;정광수
    • 한국정보과학회논문지:정보통신
    • /
    • 제34권2호
    • /
    • pp.100-109
    • /
    • 2007
  • 가용대역폭(Available Bandwidth) 측정 기법을 이용한 기존 스트리밍 프로토콜들(Streaming Protocol)은 가용대역폭을 측정하는 것에 있어서 정확성이 떨어지는 문제와 측정 속도가 느리다는 문제를 가지고 있다. 본 논문에서는 기존 가용대역폭 측정방법에 대한 연구가 가지고 있는 한계점을 극복하기 위해서 새로운 가용대역폭 측정 기법인 NABO(New Available Bandwidth measurement based on One-Way Delay)를 제안한다. NABO는 OWD(One-Way Delay)에 포함되어 있는 경쟁 트래픽이 없을 때의 전송 지연시간을 추출해 내고, 그 이후에 OWD에 반영하는 전송 지연시간을 제외한 경쟁트래픽에 의한 가변적인 지연을 측정함으로써 경쟁트래픽의 양을 측정한다. 이를 통해서 병목링크의 고정대역폭에서 경쟁트래픽의 대역폭을 제외한 가용대역폭을 정확하고 빠르게 산출한다. NABO의 성능을 검증하기 위한 실험 결과, 제안한 NABO가 다양한 네트워크 환경에서 스트리밍 서비스(Streaming Service)의 요구사항을 효율적으로 만족시킬 수 있음을 확인할 수 있었다.

단방향 지연 변이와 일주 지연을 이용한 양단간의 단방향 지연 추정 (One-Way Delay Estimation Using One-Way Delay Variation and Round-Trip Time)

  • 김동근;이재용
    • 한국컴퓨터정보학회논문지
    • /
    • 제13권1호
    • /
    • pp.175-183
    • /
    • 2008
  • 네트워크에서 QoS(quality of Service) 제공 기술은 양단간 네트워크 경로의 안정성과 성능의 정도를 나타내는 QoS 척도에 대한 실제 측정에 기반을 두고 있다. QoS 척도 중에서 특히 단방향 지연의 측정은 양단간 두 측정 지점간의 클럭(clock) 동기가 선행되어야 한다. 하지만, 네트워크에서 모든 단말 또는 호스트(host) 사이에는 절대적 또는 상대적인 시간 차이가 존재한다. 본 논문에서는, 단방향 지연 단방향 지연 변이와 일주 지연(round-trip time: RTT) 간의 관계식을 새롭게 유도하여 추정 오류가 일주지연의 사분의 일 이하가 됨을 수학적으로 보여주며, 이를 이용한 단방향 지연과 클럭 오프셋(offset)의 추정 기법을 제안하고 실험을 통하여 본 제안의 유용성을 보여준다.

  • PDF

A new color management approach for dye manufacturing process with image processing and intelligent algorithm

  • Kyungwon Jang;Taechon Ahn;Lee, Dongyoon;Yangwoong Yoon;Jinhyun Kang
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2002년도 ICCAS
    • /
    • pp.56.2-56
    • /
    • 2002
  • A dye process of textile industry is important part that finally gives required quality to the textile material. To produce a proper dye for the customers, color management that precise color measurement from original color sample and rapid estimation of corresponding color recipe is most essential. In the practical dye manufacturing process, color management falls into two categories. First one is color management with an expert knowledge of colorist, the other one is computer aided way. In the former management way, color management fully depends on colorists' expert without support of the measurement and computational devices. Objective color management is impossible in this way. The...

  • PDF

Frequency-Based Image Analysis of Random Patterns: an Alternative Way to Classical Stereocorrelation

  • Molimard, J.;Boyer, G.;Zahouani, H.
    • 비파괴검사학회지
    • /
    • 제30권3호
    • /
    • pp.181-193
    • /
    • 2010
  • The paper presents an alternative way to classical stereocorrelation. First, 2D image processing of random patterns is described. Sub-pixel displacements are determined using phase analysis. Then distortion evaluation is presented. The distortion is identified without any assumption on the lens model because of the use of a grid technique approach. Last, shape measurement and shape variation is caught by fringe projection. Analysis is based on two pin-hole assumptions for the video-projector and the camera. Then, fringe projection is coupled to in-plane displacement to give rise to 3D measurement set-up. Metrological characterization shows a resolution comparable to classical (stereo) correlation technique ($1/100^{th}$ pixel). Spatial resolution seems to be an advantage of the method, because of the use of temporal phase stepping (shape measurement, 1 pixel) and windowed Fourier transform (in plane displacements measurement, 9 pixels). Two examples are given. First one is the study of skin properties; second one is a study on leather fabric. In both cases, results are convincing, and have been exploited to give mechanical interpretation.

NEW ASPECTS OF MEASURING NOISE AND VIBRATION

  • Genuit, K.
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 1994년도 FIFTH WESTERN PACIFIC REGIONAL ACOUSTICS CONFERENCE SEOUL KOREA
    • /
    • pp.796-801
    • /
    • 1994
  • Measuring noise, sound quality or acoustical comfort presents a difficult task for the acoustic engineer. Sound and noise are ultimately jugded by human beings acting as analysers. Regulations for determining noise levels are based on A-weighted SPL measurement performed with only one microphone. This method of measurement is usually specified when determining whether the ear can be physically damaged. Such a simple measurement procedure is not able to determine annoyance of sound events or sound quality in general. For some years investigations with binaural measurement analysis technique have shown new possibilities for the objective determination of sound quality. By using Artificial Head technology /1/, /2/ in conjunction with psychoacoustic evaluation algorithms - and taking into account binaural signal processing of human hearing, considerable progress regarding the analysis of sounds has been made. Because sound events often arise in a complex way, direct conclusions about components subjectively judged to be annoying with regard to their causes and transmission paths, can be drawn in a limited way only. A new procedure, complementing binaural measurement technology combined with mulit-channel measuements of acceleration sensor signals has been developed. This involves correlating signals influencing sound quality, analyzed by means of human hearing, with signals form different acceleration sensors fixed at different positions of the sound source. Now it is possible to recognize the source and the transmission way of those signals which have an influence on the annoyance of sound.

  • PDF

성과 정보 통합 방법의 개발 (Developing a Performance Information Integration Method (PIIM))

  • 박창규
    • 산업공학
    • /
    • 제11권3호
    • /
    • pp.41-53
    • /
    • 1998
  • Several performance measurement systems have been proposed and are currently being used in many organizations. However, no performance measurement system has presented a mechanism for integrating all of the information of performance measures in a way that considers the relationships between them. This paper proposes the performance information integration method (PIIM) which synthesizes all useful information of performance measures with consideration of the relationships and generates a single, global, organizational performance score. The PIIM showed good performance in the implementation in one long-term care facility. This paper provides performance measurement systems with an integration mechanism for multiple performance measures.

  • PDF

Effects of Plank Exercises with Resistance of One-Sided Hip Adduction on the Abdominal Muscle Thickness

  • Park, JaeCheol;Jeong, JinGyu
    • The Journal of Korean Physical Therapy
    • /
    • 제31권2호
    • /
    • pp.82-87
    • /
    • 2019
  • Purpose: The purpose of this study was to examine the effects of plank exercises with resistance of one-sided hip adduction on abdominal muscle thickness. Methods: Thirty subjects were divided into a group that underwent plank exercises with one-sided hip adduction resistance (n=15) and a group that underwent plank exercises only (n=15). Their changes in abdominal muscle thickness before the experiment (n=15) and three and six weeks after the experiment were analyzed using a two-way repeated analysis of variance at a statistical significance level of ${\alpha}=0.05$. When there was any interaction between the time of measurement and each group, post hoc t-tests were conducted at a statistical significance level of ${\alpha}=0.01$. Results: The results of the experiment showed statistically significant differences in the thickness of the rectus abdominis, internal oblique muscle, and transversus abdominis, depending on the time of measurement and the interaction between the time of measurement and each group (p<0.05). Statistically significant differences were observed in the thickness of the external oblique, depending on the time of measurement, the interaction between the time of measurement and each group, and variances between the groups (p<0.05). Conclusion: The results of this study indicated that plank exercises with resistance of one-sided adduction are effective for increasing abdominal muscle thickness. The study's overall findings will likely be used as basic data for lumbar stabilization exercises and rehabilitation treatment.

공영방송 성과측정관행의 진단 틀 (Diagnostic Framework for Performance Measurement Practices of Public Broadcasting)

  • 민재형
    • 경영과학
    • /
    • 제26권1호
    • /
    • pp.137-159
    • /
    • 2009
  • An organizational performance measurement practice is a function of performance measurement system and performance management system they are currently employing, and its quality is determined by evaluating the followings in a comprehensive manner: first, if they are measuring right things; second, if they are measuring in a right way; third, if they are actively facilitating a process of data collection, structuring, analysis, interpretation, and dissemination; and fourth, if they are using performance measurement results for the primary purposes of performance measurement. This study proposes a diagnostic framework for evaluating the performance measurement practices of public broadcasting which include the qualities of performance measurement and performance management, and develop a structured questionnaire for that purpose. The framework proposed in this study does not serve only as a useful tool for public broadcasting to revise their respective performance measures and performance measurement systems, but it also make their respective performance measurement practices a strategic management tool as well as an operational management one.

FIELD TEST INSTALLATIONS USING N$H_3$SENSOR AND VENTILATION RATE SENSOR FOR CONTINUOUS MEASUREMENT OF TOTAL AMMONIA EMISSION FROM ANIMAL HOUSES

  • Berckmans, D.;Ni, J.Q.
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1993년도 Proceedings of International Conference for Agricultural Machinery and Process Engineering
    • /
    • pp.393-402
    • /
    • 1993
  • Two field test installations are discussed. In the first one a new ammonia sensor and an accurate ventilation rate sensor are combined. They are installed in the exhaust chimney in a ventilated pig house. The relative humidity and the room temperature are measured as well. In the second one, an in situ NH$_3$longrightarrowNO converter with subsequent NOx analyser is also being added for accurate ammonia measurement . In this way , the continuous measurement of the total NH$_3$emission can be obtained , the performance of the NH$_3$ sensor can be evaluated, and the ammonia reduction techniques can be tested. The outputs of measurement are fed into a data acquisition system then to a PC in the laboratory. There has been realised the first test installation with which research on the new ammonia sensor is carried out. The primary research results are presented.

  • PDF