• Title/Summary/Keyword: one-way RC slab

Search Result 16, Processing Time 0.105 seconds

전산수치해석을 이용한 일방향 철근콘크리트 부재의 폭발 실험결과 분석 (Experimental Data Analysis using Computational Numerical Analysis on the Response of One-way Reinforced Concrete Slab under Blast Loading)

  • 지훈
    • 한국군사과학기술학회지
    • /
    • 제19권4호
    • /
    • pp.424-434
    • /
    • 2016
  • A few blast experiments are conducted to investigate the behavior of one-way reinforced concrete(RC) slabs under blast loading. Reflected blast characteristics as well as displacements and damage patterns of RC slabs are measured. Numerical models are also established in the software ANSYS AUTODYN to reproduce the experiments on RC slabs. The numerical models are distinguished from each other by different boundary conditions at the edges of RC slabs, which are assumed to reproduce displacements and damage patterns resulted from the experiments. The boundary condition of the experimental tests is estimated from the numerical simulation results. From the numerical simulation results, the boundary condition should be improved in order to measure the accurate maximum displacement in the experimental tests.

The influence of load pulse shape on pressure-impulse diagrams of one-way RC slabs

  • Wang, Wei;Zhang, Duo;Lu, Fangyun
    • Structural Engineering and Mechanics
    • /
    • 제42권3호
    • /
    • pp.363-381
    • /
    • 2012
  • This study is aimed at providing an efficient analytical model to obtain pressure- impulse diagram of one-way reinforced concrete slabs subjected to different shapes of air blast loading using single degree of freedom method (SDOF). A tri-linear elastic perfectly plastic SDOF model has been used to obtain the pressure-impulse diagram to correlate the blast pressure and the corresponding concrete flexural damage. In order to capture the response history for the slab, a new approximately SDOF method based on the conventional SDOF method is proposed and validated using published test data. The influences of pulse loading shape on the pressure-impulse diagram are studied. Based on the results, a pressure-impulse diagram generation method using SDOF and an analytical equation for the pressure-impulse diagram is proposed to different damage levels and different blast loading shapes.

Effect of one way reinforced concrete slab characteristics on structural response under blast loading

  • Kee, Jung Hun;Park, Jong Yil;Seong, Joo Hyun
    • Advances in concrete construction
    • /
    • 제8권4호
    • /
    • pp.277-283
    • /
    • 2019
  • In evaluating explosion-protection capacity, safety distance is broadly accepted as the distance at which detonation of a given explosive causes acceptable structural damage. Safety distance can be calculated based on structural response under blast loading and damage criteria. For the applicability of the safety distance, the minimum required stand-off distance should be given when the explosive size is assumed. However, because of the nature of structures, structural details and material characteristics differ, which requires sensitivity analysis of the safety distance. This study examines the safety-distance sensitivity from structural and material property variations. For the safety-distance calculation, a blast analysis module based on the Kingery and Bulmash formula, a structural response module based on a Single Degree of Freedom model, and damage criteria based on a support rotation angle were prepared. Sensitivity analysis was conducted for the Reinforced Concrete one-way slab with different thicknesses, reinforcement ratios, reinforcement yield strengths, and concrete compressive strengths. It was shown that slab thickness has the most significant influence on both inertial force and flexure resistance, but the compressive strength of the concrete is not relevant.

일방향 철근 콘크리트 슬래브의 폭발 피해 분석을 위한 최적의 비파괴검사법에 관한 연구 (The Study on the Optimal NDT Method for the Explosion Damage Analysis for One-way RC Slabs)

  • 이승재;오태근;박종일;김희식
    • 한국안전학회지
    • /
    • 제32권5호
    • /
    • pp.62-68
    • /
    • 2017
  • It is necessary to analyze on the compressive strength among material properties of concrete for confirming damages of architectures due to large explosion. A non destructive test is known as the representative methods estimating compressive strength and ultrasonic pulse velocity, rebound hardness test are widely used because of their simplicity, convenience. But combined method supplementing two types is applied at now as they are affected by the characteristics of test specimen. In this research to check damages on the members of structure before and after explosion, the characteristics of compressive strength are compared and analyzed through a real explosion test prior to full scale structures. The test results showed that the larger the TNT powder and the shorter the distance, the greater the decrease in strength before and after the explosion and that the largest displacement and moment for the explosive load and the greatest decrease in the strength at the central part. Due to the surface condition and the thickness variation of the concrete specimens, the standard deviation value is the smallest in the combining method of fusion of the ultrasonic method and rebound hardness method. Thus, the combining method can be one of appropriate methods to evaluate the strength in the reinforced concrete structures damaged by the explosion.

Required ties in continuous RC beams to resist progressive collapse by catenary action

  • Alrudaini, Thaer M.S.
    • Structural Engineering and Mechanics
    • /
    • 제78권4호
    • /
    • pp.403-411
    • /
    • 2021
  • Ties are mandated by many design guidelines and codes to prevent the progressive collapse of buildings initiated by local failures. This study develops a model to estimate catenary/cable action capacity and the required ties in continuous reinforced concrete beams to bridge above the potential failed interior columns. The developed model is derived based on virtual work method and verified using test results presented in the literature. Also, parametric investigations are conducted to estimate the required ties in continuous reinforced concrete beams supporting one-way slab systems. A comparison is conducted between the estimated tie reinforcement using the developed model and that provided by satisfying the integrity provisions of the ACI 318-14 (2014) code. It is shown that the required tie reinforcements to prevent progressive collapse using the developed model are obviously larger than that provided by the integrity requirements of the ACI 318-14 (2014) code. It has been demonstrated that the increases in the demanded tie reinforcements over that provided by satisfying ACI 318-14 (2014) integrity provisions are varied between 1.01 and 1.46.

플랫 플레이트 시스템의 처짐에 대한 시공 중 과하중의 영향 평가를 위한 실용해석 기법의 적용 (Applications of Practical Analysis Scheme for Evaluating Effects of Over-Loads during Construction on Deflections of Flat Plate System)

  • 김재요
    • 한국전산구조공학회논문집
    • /
    • 제22권1호
    • /
    • pp.25-34
    • /
    • 2009
  • 큰 휨 지지력을 제공하는 테두리 보가 없이 기둥과 바닥판만으로 구성된 플랫 플레이트 시스템은 응력 조건뿐만 아니라 사용성 조건에 의하여 구조적 성능이 결정될 수 있다. 시공 순서 및 그에 따른 동바리로 연결되어 있는 슬래브들 간의 시공 하중 분포에 대한 영향이 플랫 플레이트의 단기 및 장기 성능에 대한 중요한 영향 요소가 될 수 있다. 이 연구에서는 슬래브 처짐 산정을 위하여, 선형해석 프로그램을 이용하여 시공 순서 및 콘크리트 균열효과를 고려할 수 있는 실용해석 기법을 제시한다. 구조설계기준에서 제시하고 있는 1방향 휨부재의 처짐 산정을 위한 유효단면 2차 모멘트의 개념을 2방향 슬래브 시스템인 플랫 플레이트의 유한요소해석에 확장하여 적용한다. 플랫 플레이트 시스템의 처짐에 대한 시공 중 과하중의 영향을 분석하기 위하여, 간편법에 의하여 산정된 시공 하중의 지배조건들에 대하여 제안된 실용해석 기법을 적용한다.