• 제목/요약/키워드: one-time key

검색결과 1,292건 처리시간 0.032초

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

산란계 동물복지에 대한 국내 소비자의 인지도 조사 (A Survey of Korean Consumers' Awareness on Animal Welfare of Laying Hens)

  • 홍의철;강환구;박기태;전진주;김현수;김찬호;김상호
    • 한국가금학회지
    • /
    • 제45권3호
    • /
    • pp.219-228
    • /
    • 2018
  • 본 연구는 국내 소비자의 계란 구매 형태와 산란계 동물복지에 대한 인지도를 조사하기 위하여 살충제 계란 파동 사태 전후 2차례에 걸쳐 수행되었다. 조사대상은 가정 내 계란 구입 주 결정권자 및 취식자인 전국 만 25~59세 여성과 만 25~35세의 1인 가구 남성을 대상으로 하였다. 조사방법은 웹조사(Computer Assisted Web Interview; CAWI) 방법과 Gang survey 방법으로 수행되었다. 계란 구매 시 주요 고려 요인에 대하여 '가격'을 고려한다는 응답이 모두 가장 높았으며, 2차 조사에서 '포장일자/제조일자'를 고려한다는 응답률이 증가하였다. 계란 10개의 적정 가격으로 '2,000~3,000원 미만' 응답 비율이 1와 2차 조사에서 각각 53.8%과 42.9%로 가장 높았으며, 적정 가격 평균은 각각 2,482원과 2,132원이었다. 국내 계란 소비자의 구매 장소에 대해 '대형마트'에서 구입한다는 응답 비율이 가장 높고, 다음으로 '중대형 슈퍼마켓', '체인 슈퍼마켓'의 순이었다. 동물복지 관련 인지도를 보면 2차 조사의 결과에서 인지 비율(73.5%)이 높아졌다. 동물복지 용어 인지 시기는 살충제 계란 파동 사태 이전 59.0%, 이후 41.0%였다. 동물복지 인증마크와 동물복지 축산농장 인증마크를 본 적이 있는지에 대해서는 처음 본다는 응답이 59.6%이며, 동물복지 인증마크를 알고 있다는 응답비율이 37.6%였다. 동물복지 사육시스템에 대하여 가장 현실적으로 적합한 동물복지형 계사로는 '방사형' 응답율이 85.8%로 가장 높았다. 동물복지 사육시스템 정보 제시 후 '방사형' 적합 응답은 34.2%p 감소한 반면, '평사형'과 '유럽형' 적합 응답은 각각 13.2%p와 24.1%p 증가하였다. 국내 소비자의 동물복지 인증 계란에 대한 인지 및 취식경험에 대하여 '본 적이 없다'는 감소한 반면, '본 적이 있다'와 '먹어 본 경험이 있다'는 응답은 모두 증가하였다. 백화점, 유기농 관련 협동조합, 인터넷 쇼핑몰에서 동물복지 인증 계란을 구입했다는 응답이 일반 계란을 구입했다는 응답비율보다 높았다. 가격 제시 전 기준으로 전체 응답자 중 동물복지 계란을 구입할 의향은 92.0%이었으나, 동물복지 계란 가격을 제시후 구입 의향은 62.7%로 가격 제시 전 대비 약 30%p 감소하였다. 동물복지 인증 계란 구입 의향 이유로는 '식품 안전성이 높을 것 같아서' 응답이 71.0%로 가장 높고, 구입 의향이 없는 이유로는 '가격이 비쌀 것 같아서'가 38.1%로 가장 높았다. 동물복지 계란 관능평가 조사에서 일반 계란의 난각색과 껍질 촉감이 동물복지인증계란보다 유의하게 더 높은 것으로 나타났으며(P<0.05), 삶은 계란은 동물복지인증계란의 흰자 색이 일반계란보다 더 밝은 것으로 인식되었다(P<0.05). 결과적으로, 본 연구결과는 동물복지 인증 농가들에게 소비자 인식에 대한 기초자료를 제공함으로써 산란계 동물복지 인증제도의 활성화에 도움이 될 것으로 판단된다.

NEMA NU2-2001을 이용한 Siemens CTI ECAT EXACT 47 스캐너의 표준 성능 평가 (Performance Evaluation of Siemens CTI ECAT EXACT 47 Scanner Using NEMA NU2-2001)

  • 김진수;이재성;이동수;정준기;이명철
    • 대한핵의학회지
    • /
    • 제38권3호
    • /
    • pp.259-267
    • /
    • 2004
  • 목적: 전신용 PET에 대한 표준 성능 평가 방법으로 NEMA NU2-2001이 확립되어 제안되었다. 따라서 새로이 설치되는 PET 스캐너뿐 아니라 기존에 사용 중인 스캐너에 대한 성능 평가가 이 표준 방법에 따라서 새로이 이루어 져야 한다. 이 연구에서는 NEMA NU2-2001 방법을 이용하여 CTI ECAT EXACT 47 PET 스캐너의 공간해상도, 민감도, 산란분획, NECR 등을 측정하였다. 대상 및 방법: 공간해상도를 평가하기 위하여 축 방향 시야의 정 가운데와 축 방향 시야 길이의 1/4을 벗어난 횡단면에 F-10을 채운 유리관(내경 1.1 mm)을 횡단면의 중심에서 1, 10 cm 떨어진 지점에 축 방향과 평행하게 위치시킨 후 PET 영상을 얻었다. 민감도를 측정하기 위하여 폴리에틸렌 및 알루미늄 관에 F-18을 채운 후 불응시간 손실이 1%를 넘지 않는 것을 확인한 후 영상을 획득하였다. 산란분획 및 최적 영상 획득 조건을 얻기 위하여 NECR을 NEMA 산란 팬텀을 이용하여 측정하였다. 결과: FBP재구성 방법(화소 크기: $0.515{\times}0.515mm^2$)으로 영상을 재 구성했을 때 스캐너의 중심에서 1cm 벗어난 지점에서 축방향, 횡축방향 공간 분해능은 0.62, 0.66 cm (FBP, 2D와 3D), 0.67, 0.69 cm (FBP, 2D와 3D)이었고 중심에서 10 cm 벗어난 지점에서 축방향, 횡축반경방향, 횡축접선방향 공간 분해능은 0.72, 0.68 mm (FBP, 2D와 3D), 0.63, 0.66 mm (FBP, 2D와 3D), 0.72, 0.66 mm (FBP, 2D와 3D)이었다. 민감도는 스캐너의 횡축방향 708.6 (2D), 2931.3 (3D) counts/sec/MBq, 횡축방향 중심에서 10cm 벗어난 지점에서 728.7 (2D), 3398.2 (3D) counts/sec/MBq 이었다. 산란 분획은 0.19 (2D), 0.49 (3D)이었고 최고 참 계수율과 NECR은 2차원 영상 획득 모드에서 40.1 kBq/mL 일 때 64.0 kcps, 40.1 kBq/mL 일 때 49.6 kcps, 3차원 영상 획득 모드에서 4.76 kBq/mL 일 때 53.7 kcps, 4.47 kBq/mL 일 때 26.4 kcps이었다. 결론: 이 실험에서 NEMA NU2-2001로 측정한 PET스캐너의 물리적 특성은 PET스캐너에 대한 객관적 평가 및 최적화 된 영상 획득과 분석에 유용할 것이다.

기업생태계 상생전략과 기업건강성효과: 삼성전자와 협력업체의 상생경영사례를 중심으로 (Cooperation Strategy in the Business Ecosystem and Its Healthiness: Case of Win - Win Growth of Samsung Electronics and Partnering Companies)

  • 성창용;김기찬;인성용
    • 기업가정신과 벤처연구
    • /
    • 제19권4호
    • /
    • pp.19-39
    • /
    • 2016
  • 제품의 복잡성이 증대될수록 기업의 전략은 나홀로(stand-alone)전략과 경쟁중심 전략에서 기업생태계 전략과 협력전략으로 이행할 필요성이 높아진다. 기업의 상생경영 및 동반성장이란 기업생태계 협력전략을 통해 대기업과 협력기업간의 기업건강성을 추구하여 장기적으로 지속가능한 성장을 하기 위한 노력이다. 본 연구는 기업 간 상생경영 및 동반성장 전략을 통해 기업생태계가 건강해질 수 있다는 이론적 명제를 삼성전자 협력업체의 사례분석과 종단적 자료에 기반한 추세분석을 통해 검증해보고자 한 것이다. 특히 본 연구에서는 중소기업생태계의 취약점의 하나인 글로벌화와 해외시장개척의 정도를 주요한 성과척도로 활용하였다. 왜냐하면 한국중소기업들이 연구개발과 창조성노력이 해외시장개척으로 연결되지 못하고 있는 연구개발 패러독스에 빠져있는 경우가 많기 때문이다. 그러므로 해외시장 개척없이는 기업생태계의 건강성 유지가 어려우며, 협력기업들은 글로벌 시장개척여부가 강소기업으로 가는 진화경로의 핵심이기 때문이다. 이를 위해 기업생태계 건강성의 특성을 나타내는 COPP 모델의 4대요소를 중심으로 분석하였다. COPP 모델이란 창조성(Creativity), 시장성(Opportunity), 생산성(Productivity), 그리고 선제적 대응성(Proactivity)이 선순환 해야 기업생태계의 지속가능성장이 만들어 질 수 있다는 것이다. 선제적 대응성(Proactivity) 이란 현재 만들어진 이익을 미래환경변화에 미래 선제적으로 투자하려는 기업가정신의 발로이며, 이러한 미래투자 없이는 현재의 저주(Curse of Incumbency)를 극복하기 어렵기 때문이다. 이 모델을 중심으로 삼성전자 동반성장의 주요 성과를 살펴보면 다음과 같다. 첫째, 시장성이 창조성, 생산성, 그리고 수익창출의 매개변수가 되고 있음을 발견 하였다. 즉, 수출(시장성)하는 협력기업일수록 연구개발투자(창조성)가 기업의 생산성, 수익성으로 연결되고 있었다. 반면 수출을 하지 않는 협력업체일수록 연구개발투자가 수익 성과로 연결되지 않는다는 것을 발견하였다. 둘째, 창조성, 시장성, 생산성, 미래 선제적 대응성의 순환 구조에 있어서, 선제적 대응성의 결과인 미래를 위한 연구개발비 투자를 많이 할수록(선제적 대응성) 특허를 많이 등록(창조성)하고, 특허를 많이 등록한 기업은 수출을 많이 하고(시장성), 수출을 많이 하는 기업은 영업이익(생산성, 수익성)이 높다는 것을 발견할 수 있었다. 이제 중소기업은 글로벌시장에 진출할 수 있는 경쟁력 보완 없이 지속적인 성장은 어렵다. 본 연구의 결과, 미래를 위한 투자인 선제적 대응성이 높은 기업일수록 창조성-시장성-생산성의 선순환이 이루어지고, 이것이 글로벌강소기업으로 진화하는 길임을 보여주는 전략적 시사점을 얻을 수 있었다.

  • PDF

착상전 유전진단을 위한 유전상담 현황과 지침개발을 위한 기초 연구 (A Study of Guidelines for Genetic Counseling in Preimplantation Genetic Diagnosis (PGD))

  • 김민지;이형송;강인수;정선용;김현주
    • Journal of Genetic Medicine
    • /
    • 제7권2호
    • /
    • pp.125-132
    • /
    • 2010
  • 목 적: 착상전 유전진단(preimplantation genetic diagnosis, PGD)은 유전질환을 가진 부부들을 대상으로 체외수정을 통해 획득한 배아에서 유전진단을 하는 방법이다. 다양한 유전질환을 가진 부부에게 그 질환에 맞는 PGD의 설계가 진행되어야 하기 때문에 PGD 시행 전유전상담을 시행하는 것은 PGD 설계에 있어서 매우 중요하다. 이에, PGD 시행 시 필요한 유전상담의 내용에 대해 환자 및 가족과 전문가의 구체적인 의견을 수렴하고 분석하고자 하였다. 대상 및 방법: 본 연구는 PGD에 있어서 유전상담의 필요성과 중요성에 대한 의견을 알아보고자, 2010년 2월 3일부터 4월 30일까지 PGD를 실시 또는 실시 예정인 부부들과 PGD 관련 전문가들을 대상으로 이메일과 직접 설문지를 배포하여 설문조사를 실시하였다. 결 과: 환자 60명과 전문가 31명을 포함하여 총 91명이 설문조사에 응답하였으며, 환자들은 염색체 이상 질환 49명(81.7%)과 단일유전자 이상 질환 11명(18.3%) 이었다. 설문에 응답한 환자와 전문가 모두 유전상담이 PGD의 의료서비스 일환으로 반드시 필요하다고 답하였다. 환자의 충분한 이해를 위하여 필요한 유전상담의 시간에 대해 환자와 가족 그리고 전문가 의견을 수렴한 결과, 각각 45명(75.0%)과 23명(74.2%)이 적정한 유전상담시간을 30분 이상이라고 응답하였다. 하지만, 현 의료시스템에서는 짧은 진료시간 내 진료와 유전상담을 동시에 진행함으로써 환자에게 완벽한 정보제공이 이루어지지 않는 것으로 나타났다. 한편, 전문가 그룹에서는 진료시간의 부족과 유전질환의 정보 부족이 유전상담의 어려운 점이라고 답하였으며, 이에 비 의사(non-MD) 전문유전상담사가 필요하다는 의견이 30명(96.7%)으로 높게 나타났다. 환자와 가족들은 PGD 시술 시 예기치 못한 결과의 가능성, 환자가 가진 유전질환의 위험을 예방할 수 있는 선택사항, 환자가 가지고 있는 유전질환의 위험도 평가, 유전자 검사 시 검사의 목적 설명 및 검사기술의 한계점과 오진률의 설명, PGD 시술 전반에 관한 기술적인 정보 등에 대하여 관심을 가지고 있으며 더 자세한 설명을 필요로 하는 것으로 나타났다. 이에 대한 전문가 의견 역시 환자 및 가족이 관심 있고 자세한 설명을 원하는 정보와 대부분 일치하였다. 이에 따라 환자의 요구와 의견으로 나타난 위의 결과들을 향후 PGD를 위한 유전상담의 지침(guide-line) 구축 시 반영하여야 할 것으로 사료된다. 결 론: 본 연구에서 유전진단과 생식의학 기술의 발전과 더불어 PGD의 적용과 효율성 등에 대한인식이 높아짐에 따라, PGD를 시행함에 있어서 구체적이고 체계적인 유전상담이 필요하다는 것을 확인할 수 있었다. 본 연구의 설문조사 결과가 향후 PGD를 위한 유전상담 지침서(guideline)에 반영되어 적절한 PGD의 설계, 실시, 사후관리에 큰 도움이 되기를 기대한다.

『전경(典經)』 「교운(敎運)」편 1장에 나타난 교운의 의미와 구절의 변이 연구 (A Study on the Meaning of 'Gyoun' and Earlier Variations of Chapter One of 'Gyoun' in The Canonical Scripture)

  • 고남식
    • 대순사상논총
    • /
    • 제36집
    • /
    • pp.153-199
    • /
    • 2020
  • 이글은 『전경(典經)』의 「교운(敎運)」편(編) 구절을 통해 교운(敎運)의 의미를 밝히고, 나아가 「교운」편 각 구절들의 변모를 『대순전경』 6판과 비교 대조하여 그 문헌학적 의미를 살펴볼 목적으로 진행되었다. 이를 위해 먼저 「교운」편 1장 구절에서 교운이라는 단어가 있는 구절을 찾아 그 의미를 고찰하였다. 이어서 도출된 교운의 의미를 중심으로 모든 「교운」편 구절을 분류하여 교운 즉 가르침의 운세(運勢)를 펼치는 것과 관련해서 상제의 천지공사(天地公事, 1901~1909), 상제가 준 교법(敎法), 상제가 소유한 권능(權能)과 지혜(智慧), 상제의 제생(濟生), 상제가 재세(在世, 1871~1909)시에 미래사에 대해 미리 보여준 예시(豫示)라는 『전경』의 각 편 명이 갖고 있는 의미의 큰 범주 안에서 「교운」편 구절의 세부적 의미를 찾아보았다. 「교운」편 1장에 대한 연구의 의미는 기존에 진행된 「행록」, 「공사」, 「교법」편에 이은 『전경』의 각 편(編)별 연구의 지속적인 수행이라는 면과 함께, 학술적으로는 교운의 의미를 찾고 「교운」편 모든 구절들을 천지공사라는 큰 틀 위에서 『전경』각 편 명(名)과의 상관성 속에서 살펴보았다는 것과 문헌학적으로는 『전경』(1974)보다 9년 앞서 출판된 증산교단의 보편화된 경전인 『대순전경』 6판(1965)과 구절들을 비교 분석하여 「교운」편 구절들의 변이의 양상을 알아낼 수 있었다는 데 그 연구의 의의가 있다. 이상의 연구 결과를 요약해 보면 다음과 같다. 첫째, 교운의 의미는 「교운」편 1장에서 '교운을 보다', '교운을 펴다', '교운을 굳건히 하다'와 관계된다. 상제가 9년간(1901~1909) 천지공사를 행하여 인류에게 가르침이 전해진 후 우주에 유토피아인 후천선경(後天仙境)이 이룩되는 것은 상제가 준 가르침의 운세를 따라 연차적으로 완결된다는 것이다. 둘째, '교운을 보는 것'은 상제 가르침의 처음과 마침의 전체적인 모습을 말한다. 상제가 교운 공사를 보았기 때문에 교(敎)는 상제로부터 시작되고 전개 발전하여 종국적으로 후천선경(後天仙境)이라는 상제 천지공사의 목적이 구현된다는 것이다. 셋째, '교운을 펴는 것'은 상제로부터 단순히 천지공사에서 가르침을 받았던 수교자(受敎者)로서의 당시의 종도(從徒)들의 참여의 시대를 지나, 이후 상제로부터 천부적으로 종통(宗統)을 전수(傳受) 받아 계승한 종통계승자에 의해 이루어진다. 이는 구절의 '마음먹은 대로 왕래하고 유력(遊歷)한다'는 '두목'이라는 용어로 예시된 내용이 종통계승자의 면모를 보여준다. 상제의 화천(化天) 뒤에 교운을 펴는 역할을 한다는 신앙적 의미가 내포되어 있으며 이는 『전경』의 교운 편(編) 1, 2장을 통해 연계적으로 나타나고 있다. 넷째, '교운을 굳건히 하는 것'은 상제의 천지공사로 도통군자가 필출(必出)하며, 또 음해(陰害)하지 말라는 것은 인간의 자기 수행에 의한 인격 완성의 가르침을 제시하고 있다. 이 인격의 완성은 교운을 굳건히 한다는 상제의 주장에 합치되는 인간의 수행 과정임을 보여준다. 다섯째, 『전경』 「교운」편 1장 구절들에 대해 『대순전경』 6판(1965)을 대비시켜보면, 두 문헌에서 거의 같은 구절은 10개 정도이다. 또 각 문헌의 서술이 단어 상 한글이 한문으로 축약되거나, 다른 용어로 나타나는 구절들이 있다. 내용의 서술이 몇 개의 어구 및 문장들에서 차이가 나는 구절들도 있다. 또한 각 문헌의 서술이 시기상 차이가 나는 구절들도 있으며, 『전경』 「교운」편 1장과 『대순전경』 6판 상호 간에 없는 단문(短文) 및 장문(長文)들도 교차적으로 나타난다.

1970년대 전통 이념과 극단 민예극장의 '전통' (A Study on Traditional Ideology and the 'Tradition' of the Theatre company Minye in 1970s)

  • 김기란
    • 대중서사연구
    • /
    • 제26권3호
    • /
    • pp.45-86
    • /
    • 2020
  • 이 글의 목적은 70년대 국가권력에 의해 소환되었던 전통 이념이 '전통의 현대화'라는 명목 아래 당대 한국연극 현장에 수용되었던 양상과 그 함의를 밝히려는데 있다. 이는 다른 한편 70년대 전통 논의를 둘러싼 한국연극계의 자기검열의 양상을 비판적으로 검토하는 작업이기도 하다. 이를 위해 이 글에서는 민족극을 창안하는 방식으로 70년대 한국연극계의 전통 논의를 선점했던 극단 민예극장의 활동을 살펴보았다. 이제까지 70년대 극단 민예극장에 대한 평가는 전통의 계승과 변용을 내세운 허규의 연출 작업을 바탕으로 공연예술적 성취 여부에 집중되었다. 하지만 70년대 국가가 주도한 문화정치의 장(場)에서 구성된 전통 이념과 그것이 작동된 양상은 예술적 성취라는 측면에서만 평가할 수 없다. 무릇 전통을 전유하려 한 주체의 선택적 기준에 따라 전통 이념은 선별되고, 선별된 전통 이념의 선택 과정에서 특정 대상들이 배제, 폐기, 재선별, 재해석, 재인식된다. 70년대 비문화로 호명되었던 서구적인 것이나 퇴폐불온한 것과의 차이 속에서, 전통이 전유되었던 70년대의 상황도 이로부터 멀리 있지 않다. 국가가 주도한 70년대의 전통 논의는 전통의 특정 이념을 안정된 가치로 합법화했는데, 그것을 작동시킨 한 방식은 국가의 문예지원이었다. 70년대 극단 민예극장은 당시 연극 위기론의 구체적 대안으로 선택되었던 전통의 현대화를 바탕으로 민족극을 지향했다. 그것은 구체적으로 전통연희의 계승과 변용이라는 방식으로 구현되었는바, 특히 극단 민예 극장의 대표 연출가 허규에게 전통은 거부할 수 없는 안정적 가치였고 그것의 계승과 변용은 의심할 바 없는 소명으로 내면화되었다. 그 결과 허규가 연출한 극단 민예극장의 공연은 일정한 성취에도 불구하고 과도한 전통연희의 관습들로 채워진 숙련된 장인술로 귀착되었다. 70년대의 전통 이념은 80년대 들어 새로운 전유의 양상으로 전개된다. 1986년 극단 민예극장의 핵심 단원이었던 손진책, 김성녀, 윤문식 등은 민예극장을 탈퇴하여 극단 미추를 만든다. 극단 미추는 연출가 손진책을 중심으로 풍자와 해학이 넘치는 마당놀이를 선보이며 전통의 대중화를 끌어냈다. 전통연희에 내재된 민중의 저항정신을 전통적 가치로 전유했던 대학가의 마당극처럼, 손진책의 마당놀이는 풍자와 해학을 통해 위압적인 국가권력을 비판하고 조롱함으로써 대중적 인기를 끌었다. 70년대 전통 논의의 자장 안에서, 민중의 저항정신을 전통적 가치로 전유하며 자생한 마당극이나 전통의 대중화를 성취한 극단 미추의 마당 놀이는 예술적 성취로써만 평가되지 않는다. 마찬가지로 전통의 계승과 변용이라는 측면에서 70년대 극단 민예극장이 성취한 것 역시 70년대 전통이 소환되었던 맥락을 제외하고 독립적으로 평가될 수 없다. 70년대 국가 주도의 전통 논의에 대응한 한국연극 평단의 시각이 예술성을 바탕으로 한 공연예술의 질적 성취에만 집중된 대목이 아쉬운 것은 그 때문이다. 이 글에서는 이런 맥락을 비판적으로 검토하고, 이를 바탕으로 70년대 극단 민예극장의 활동을 중심으로 당대 한국연극계의 전통 논의와 그 실천 양상을 살펴보았다. 결과적으로 70년대 극단 민예극장의 활동이 한 계기로 작용했을 대중적 마당놀이나 민중저항의 마당극은 70년대 극단 민예극장이 전통을 전유하는 방식, 곧 전통의 계승과 현대적 변용과의 '차이' 속에 정립되었다. 계기는 되었으나 그에 따른 유의미한 차이를 지속적으로 생산해내지 못한 점, 이것이 극단 민예극장의 '전통'이 70년대 한국연극사에서 차지하는 의미이자 한계이다.

고려상표군을 이용한 내구재 시장구조 분석에 관한 연구: 자동차 시장에 대한 탐색적 분석방법 (A Study on the Market Structure Analysis for Durable Goods Using Consideration Set:An Exploratory Approach for Automotive Market)

  • 이서구
    • Asia Marketing Journal
    • /
    • 제14권2호
    • /
    • pp.157-176
    • /
    • 2012
  • 시장구조 분석에서 흔히 사용되는 상표전환 자료는 비내구재 분석에 적절한 방법이 될 수 있으나 자동차 같이 사용연한이 장시간인 내구재의 경우에는 소비자의 상표에 대한 선호도가 변할 수 있어 상표전환 자료의 사용에 문제가 있다. 따라서 경쟁을 잘 포착할 수 있는 다른 접근이 필요하다. 본 연구는 이에 대한 대안으로 상표간 경쟁 자료로써 고려상표군을 이용하여 자동차 시장의 구조를 Latent Class 군집분석을 활용한 탐색적 검증방법으로 분석하였다. 또한 소비자 행동분석에 근거하여 상표간 경쟁의 근간을 이루는 고려상표군 형성에 영향을 미치는 인자들을 밝히는데 중점을 두었다. 미국 자동차 시장을 대상으로 분석한 결과, 시장은 상표 원산지 효과에 의해 구분되었다. 즉, 미국 상표, 유럽 상표, 그리고 아시아 상표 등으로 시장이 구분되었다. 또한 각 시장구조 내 소비자들의 고려상표군 형성에 신뢰성/안전, 이미지/즐거움, 경제성 등의 편익과 성별, 소득 등 개인적 요인이 영향을 미치는 것으로 나타났다.

  • PDF

기업정보 기반 지능형 밸류체인 네트워크 시스템에 관한 연구 (A Study on Intelligent Value Chain Network System based on Firms' Information)

  • 성태응;김강회;문영수;이호신
    • 지능정보연구
    • /
    • 제24권3호
    • /
    • pp.67-88
    • /
    • 2018
  • 최근까지도 중소기업의 지속성장 및 경쟁력 확보에 대한 중요함을 인식함에 따라, 정부 차원에서의 유형 자원(R&D 인력, 자금 등)에 대한 지원이 주로 투입되어 왔다. 그러나 사업지원의 적절성이나 효과성, 효율성 면에서 서로 상충되는 정책부분이 존재하여 과소 지원이나 중복 지원 등 지원체계의 비효율성 문제가 제기되어온 것도 사실이다. 정부나 기업 관점에서는 중소기업의 한정된 자원으로 인해, 외부와의 협력을 통한 기술개발 및 역량강화가 기업의 경쟁우위를 창출하는 근간이라 보고 있으며, 이를 위한 가치창출 활동을 강조하고 있다. 기업 레벨에서의 지식생태계 구축을 통해 일련의 가치사슬로부터 기업거래 관계를 분석하고 결과를 가시화할 수 있는 밸류체인 네트워크 분석이 필요한 것도 이 때문이다. 특허/제품/기업명 검색을 통해 관련 제품의 정보나 특허 보유 기업의 기술(제품) 현황 정보를 제공하는 기술기회발굴시스템(Technology Opportunity Discovery system), 기업(재무)정보와 신용정보을 열람하게 해주는 CRETOP이나 KISLINE 등은 존재하고 있으나 밸류체인 네트워크 분석기반으로 유사(경쟁)기업의 리스트나 향후 거래 가능한 잠재 거래처 정보를 제공해주는 시스템은 부재한 실정이다. 따라서, 본 고에서는 KISTI에서 개발 운영중인 기업 비즈니스 전략수립 지원 파트너인 '밸류체인 네트워크 시스템(Value Chain Network System : VCNS)'을 중심으로, 탑재된 네트워크 기반 분석모듈의 유형, 이를 지원하는 참조정보 및 데이터베이스(D/B)의 구성 로직과 시스템 활용방안을 고찰하며, 산업구조를 이해하고 기업의 신제품 개발을 위한 핵심정보가 되고 있는 지능형 밸류체인 분석 시스템의 네트워크 가시화 기능을 살펴보기로 한다. 한 기업이 다른 기업 대비 경쟁우위를 확보하기 위해서는 보유 특허 또는 현재 생산하고 있는 제품에 대한 경쟁자 식별이 필요하며, 세부 업종별 유사(경쟁)기업을 탐색하는 일은 대상기업의 사업화 경쟁력 확보에 핵심이 된다. 또한 기업간 비즈니스 활동인 거래정보는 유사 분야로 진출할 경우 잠재 거래처 정보를 제공하는 중요한 역할을 수행한다. 이러한 기업간 판매정보를 기반으로 구축된 네트워크 맵을 활용하여 기업 또는 업종 수준의 경쟁자를 식별하는 일은 밸류체인 분석의 핵심모듈로 탑재될 수 있다. 밸류체인 네트워크 시스템(VCNS)은 단순 수집된 종래의 기업정보에 밸류체인(value chain) 및 산업구조 분석개념을 접목하여 개별 기업의 시장경쟁 상황은 물론 특정 산업의 가치사슬 관계를 파악할 수 있다. 특히 업종구조 파악, 경쟁사 동향 파악, 경쟁사 분석, 판매처 및 구매처 발굴, 품목별 산업동향, 유망 품목 발굴, 신규 진입기업 발굴, VC별 핵심기업 및 품목 도출, 해당 기업별 보유 특허 파악 등 기업 레벨에서의 유용한 정보분석 툴로 활용 가능하다. 또한, 거래처 정보 및 재무데이터로부터 분석된 결과의 객관성 및 신뢰성을 기반으로, 현재 국내에서 이용 중인 15,000여개 회원기업과 연구개발서비스업 종사자, 출연(연) 및 공공기관 등에서 사업평가 정보지원, R&D 의사결정 지원 및 중 단기 수요예측 전망 등 다양한 목적(용도)에 밸류체인 네트워크 시스템을 활용할 수 있을 것으로 기대된다. 기업의 사업경쟁력 강화를 위해 정부기관 및 민간 연구개발서비스 기업을 중심으로 기술(특허) 및 시장정보가 제공되어 왔으며, 이는 특허분석(등급, 계량분석 위주) 또는 시장분석(시장보고서 기반 시장규모 및 수요예측 위주)의 형태로 지원되어 왔다. 그러나 기업이 사업화진출 단계에서 겪게 되는 애로요인의 하나인 정보부족을 해결하는데 한계가 있었으며, 특히 경쟁기업 및 거래가능 기업 후보군에 대한 탐색정보는 입수하기 어려웠다. 본 연구를 통해 제안된 네트워크맵 및 보유 데이터 기반의 실시간 밸류체인 가시화 서비스모듈이 중견 중소기업이 당면한 신규시장 진출시 경쟁기업 대비 예상점유율, (예상)매출액 수준, 어느 기업을 컨택하여 유통망(원자재/부품에 대한 공급처, 완제품/모듈에 대한 수요처)을 확보할 지에 대한 핵심정보를 제공할 수 있을 것으로 기대된다. 향후 연구에서는 대체기업(또는 대체품목) 경쟁지표의 개발과 연구주체의 참여를 통한 경쟁요인별 지표의 고도화 연구, VCNS의 성능향상을 위한 데이터마이닝 기술 및 알고리즘을 추가 반영하도록 수행하고자 한다.