• Title/Summary/Keyword: one way direction

Search Result 432, Processing Time 0.033 seconds

A Study about Indoor Environmental Improvement of Green Building Certification System through, POE (거주 후 평가를 통한 친환경 인증제도의 실내환경 개선 방향에 대한 연구)

  • Lee, Myung-Joon;Lee, Jong-Chan;Kim, Kwoang-Ho;Kim, Byung-Sean
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1055-1060
    • /
    • 2006
  • The Korean Green Building Certification System was activated from 2005. The purpose of it is to improve the quality of residential unit. Recently, people stay inside of building more than for 90% of a day Accordingly, it is really important for them to make the quality of Indoor Environmental better, in brief, to develop the indoor environmental factor in KGBC is important. One of the best way to develop the system is to do research based on POE because the area of problem can be realized. Accordingly, we get the information about POE from another research for the part of the indoor environment for residential unit to have the critical mind about the KGBC, and tried to compare the factors to another which is from foreign Green Building Certification System such as LEED, BREEAM, GBTool, After they have been analyzed, we could find that some of factor need to be revised and added. Also, there was one problem that many part of factor was created without any consideration of direction of each space in residential unit.

  • PDF

Effect of Sports Psychology on Enhancing Consumer Purchase Intention for Retailers of Sports Shops: Literature Content Analysis

  • LEE, Jae-Hyung
    • Journal of Distribution Science
    • /
    • v.19 no.4
    • /
    • pp.5-13
    • /
    • 2021
  • Purpose: The sporting field is one of the most lucrative industries that most producers would want to share and drive-in sales towards its direction. The purpose of the present study is to evaluate how sports psychology has become a useful discipline in enhancing consumer purchase intentions. Research design, data, and methodology: This study employs a qualitative coding method to analyze and interpret the data obtained with a PRISMA declaration for analytical purposes. Using Web QDA (Qualitative Data Analysis) online tools, the current study coded the data obtained. Results: According to the prior studies, marketers should go the extra mile of looking for what sports customers are looking for. They understand that one way to increase the customers' willingness to purchase their products is by looking into the specific things that the customers look for and enjoy in sports. Conclusions: After all, the present study concludes that most marketers need to apply the concepts of sports psychology to understand consumer purchase intentions in particular retail stores. Consumers are likely to be influenced by their peers or groups to make decisions driven towards purchasing given sports apparel and the retail store to purchase a product.

Numerical Analysis of Ventilation System for Dust Removal Inside the Enclosed Conveyor Belt (밀폐된 컨베이어 벨트 내부의 분진 제거를 위한 환기 시스템의 수치해석적 분석)

  • Yeseung Lee;Ki Jin Jeong;Jong Min Kim;Jung-Hun Noh
    • Particle and aerosol research
    • /
    • v.19 no.2
    • /
    • pp.43-53
    • /
    • 2023
  • In this study, the ventilation system of the enclosed conveyor belt for coal transportation was evaluated, and the particle removal efficiency according to the ventilation conditions was identified using computational fluid dynamics and particle behavior analysis. The most effective way to remove dust generated inside the closed conveyor belt is to adjust the position of the exhaust port of the duct so that the air is exhausted around the rear of the conveyor belt. And this method seems to work for another narrow and long spaces where air enters in one direction. In addition, when the air flow rate of the each duct was less than 300 CMM, it was efficient to increase the flow rate of the duct located at the rear of the conveyor belt, and when the flow rate of the each duct was higher than 300 CMM, it was efficient to increase the flow rate of the duct located at the front of the conveyor belt.

An Analytic Study on the Figure of Number Line (수직선 표기법에 대한 분석 연구)

  • Suh, Bo Euk;Shin, Hyun Yong;Na, Jun Young
    • Journal of Educational Research in Mathematics
    • /
    • v.23 no.2
    • /
    • pp.135-152
    • /
    • 2013
  • The purpose of this study is to navigate to the desired direction for the figure of number line through the extensive analysis of number line in middle school textbooks and literatures. For the efficient achievement of this purpose, three research questions were posed as follows: First, we compare the figures of number line in textbooks of Korea and other countries. Korean math textbooks mark the arrow on both sides of number line. But, however, coordinate plane was marked with arrow on only positive direction of number line. In contrast, the majority of secondary school textbooks in several foreign countries has the arrow only on positive direction. Second, the change in the figure of number line has been analyzed historically from two perspectives. From the first to 2007-revised curriculum, math textbooks of Korea were analyzed. Since the 6th curriculum, the number of textbooks with arrows on both sides has increased sharply. That is, textbooks with one arrow almost have disappeared. It is strange that any explanation for this abrupt change can't be found. The following analysis was also performed on published foreign literatures since Descartes. There was no arrow in the early figures of number line. But after 19th century, number lines with one arrow have begun to appear. Third, based on the previous study, we propose a reasonable way for the figure of number line. In fact, we claim that, in terms of linguistic symbols, the number line should be with only one arrow on positive side.

  • PDF

The Observationi of User Behaviors of the Urban Plaza using Time-Lapse Record-A case study of Chungryangri Station Plaza- (Time-Lapse 촬영방법을 이용한 도심 광장의 이용행태에 관한 연구 -청량리 역광장을 사례로-)

  • 조창완;진양교
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.26 no.3
    • /
    • pp.199-212
    • /
    • 1998
  • The ultimate goal of this study can be summed up as follows: First, the utility of Time-Lapse that observes and records people's behavior will be shown and its merits and demerits will be discussed through comparing with other data-collecting methods such as the naked- eye observation, and the specific way in which Time-Lapse can be put to use will be suggested. Second, analysis of use behavior boserved in the plaza of Chungryangri station by Time-Lapse will be made, on the basis of which suggestions will be made concerning planing, designing, layout, and management of the station plaza. Time-Lapse can observe and records the plaza of Chungryangri Staton through 6 different ways of recording in Time-Lapse: 30 seconds, every minute, every two minutes, second every five minutes, every one tenth of a second, and every one fifth of a second, and these different ways of recording were analyzed through comparison from one to each other to check their respective utilities. And also analysis of tracks of pedestrians, density, and use behavior of users were made, according to which the way in which Time-Lapse can be utilized was examined. Several useful results obtained from this study are shown as follows. First, Time-Lapse made it possible to continuously observe for a long time using minimu efforts, and a single tape which is able to cover from 12 hours up to 25 days is useful for observing variation of behavior in space with the passage of time and seasons. Second, among six ways of recording, the recording every one tenth of a second and every one fifth of a second are useful for finding the tracks of pedestrians, the number of users, the member compositions, the time spent in one place, and manner of use. And besides the moving direction and its purpose can be recognized in a short time, which makes it possile to see where crossings of moving directions occur. Third, the recording every thirty seconds, every minute, every two minutes, and every five minutes are useful for analyzing the density in space as well as for finding the number of users and frequency of facilities use. In particular the recording every thirty seconds made it possible to keep the track of pedestrians' walking, and to observe even slowly moving motions such as cleaning. But when the recording interval exceeds one minute, this was not possible. Fourth, time-lapse has advantages over the naked eye observation in several respects. Time-lapse can measure observed behavior and density in terms of number, and locate the position of users. Time-Lapse, if accompanied by other methods such as interviewing and question that can examine psychological aspects like satisfaction or the purpose of use and be a useful device for space studies.

  • PDF

Gluteus Medius Muscle Activities According to Various Angle of Mediolateral Ramp During Cross Walking and One-leg Standing (다양한 각도의 경사로 횡단 조건에서 보행과 한발 서기 시 중둔근 활성도)

  • Kim, Seon-Chil;Lee, Sang-Yeol
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.12 no.2
    • /
    • pp.53-57
    • /
    • 2017
  • PURPOSE: The purpose of study was to clear up the environmental risk factor that can be easily occurred unstability of hip during gait and one leg standing at various ramp angle. METHODS: Twenties healthy males of 69 subjects is participated in this study. Participants was measured activation on gluteus medius muscle during both conditions (walk across the ramp and one leg stand in the transverse direction) of seven different angle. The measured data were analyzed using one-way ANOVA to investigate the effect of muscle activation on the each condition. The statistical analyses were performed using SPSS ver. 18.0 and p-value less than .05 were considered significant for all cases. A post-hoc test was performed by Bonferoni method. RESULTS: The study showed that more muscle activities on gluteus medius is increased by increasing the ramp angle. Post-hoc analysis demonstrated that the peak and mean of muscle activity increased significantly with a ramp angle of $15^{\circ}$ and $25^{\circ}$ during gait and one-leg stand. CONCLUSION: According to the study results, impaired balance can be easily occurred when cross walk and one-leg stand on a ramp from higher than $15^{\circ}$, and highest risk was angle of $25^{\circ}$ or more. As a people with gluteus medius muscle weakness walks a ramp, the ramp angle has a cross relationship with the impaired balance. If people with gluteus medius weakness walk on the more than $10^{\circ}$ of ramp angle, they will need a lot of attention for prevent impaired balance.

The Influence of Foot Position on Standing Balance on an Unstable Base of Support

  • Lee, Jun Cheol
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.10 no.2
    • /
    • pp.84-94
    • /
    • 2018
  • The purpose of this study was to compare the balance ability at different foot positions using K A T 2000 (Berg, Inc, vista, CA.1994). Thirty (male 15, female 15) normal subjects participated in this study. All subjects were tested at a one leg position or a two leg position that were toe-in $25^{\circ}$, toe-out $25^{\circ}$, and $45^{\circ}$. The starting position was where the subject crossed their arms across the chest and flexed knees slightily. The results of each test were displayed on a screen in a score format, which indicated balance index. These collected data were analyzed by using one way ANOVA, and t-test. The results of this study were as follows: When changing the angle of the foot in the one-foot and two-foot standing positions, there was no statistically significant difference, but the balance performance with the foot rotated by $25^{\circ}$ was better than that with the foot rotated by $45^{\circ}$. When changing the direction of the foot in the one-foot and two-foot standing positions, there was no statistically significant difference, but the balance performance with the foot rotated laterally was better - except for the case when the foot was medially rotated by $25^{\circ}$ in the right-foot static standing position. When the feet were medially rotated by $25^{\circ}$ in the two-foot static standing position, and were medially rotated by $25^{\circ}$ and $45^{\circ}$ in the one-foot static standing position, the balance performance of females was better than that of males. In this study, it was found that the balance performance of the subjects changed when the position of the foot was shifted on an unstable base of support. However, there was little correlation between balance performance and the height, weight and foot length of the subjects. It is necessary to conduct a follow-up study targeting various age groups and those with various diseases using an unstable platform or applying different physical or visual conditions, such as the length of the legs. Physical therapists need to consider the position of the foot in clinical settings for a better balance training or assessment.

THE EFFECT OF AUTOCLAVE STERILIZATION AND REUSE OF $SMARTPEG^{TM}$ ON THE IMPLANT STABILITY QUOTIENT (ISQ) MEASUREMENT ($Smartpeg^{TM}$의 고압멸균소독 및 재사용이 임플랜트 안정성 지수(ISQ) 측정에 미치는 영향)

  • Kang, In-Ho;Kim, Myung-Joo;Lim, Young-Jun;Kim, Chang-Whe
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.5
    • /
    • pp.644-652
    • /
    • 2007
  • Statement of problem: Resonance frequency analysis is evaluated as the non-invasive and objective method for the evaluation of implant stability and has been increasingly used. It is necessary to evaluate the factors affect the ISQ measurement stability. Purpose: This study was performed to evaluate the effect of the autoclave sterilization and reuse of $Smartpeg^{TM}$ on ISQ measurement. Material and methods: $SmartPeg^{TM}$ (Integration Diagnostics Ltd., $G\ddot{o}teborg$, Sweden) of autoclave group (A) was autoclave sterilized 9 times and $Smartpeg^{TM}$ of reuse group (R) was reused 9 times. Ten $SmartPeg^{TM}s$ were allocated to each group and after each autoclave sterilization and reuse, implant stability quotient (ISQ) values were measured 3 times from the two directions a and b at a right angle. $Osstell^{TM}$ mentor (Integration Diagnostics Ltd. $G\ddot{o}teborg$, Sweden) was used and type 1 (article no. 100353) $Smartpeg^{TM}$ was selected according to $Smartpeg^{TM}$ reference list. Osstem Implant US II future (Osstem Co., Seoul, Korea) in $4.0mm{\times}11.5mm$ was embedded in the self-curing acrylic resin ($Orthojet^{(R)}$, Lang Dental, U.S.A.). Data was statistically analyzed by one-way ANOVA $({\alpha}=.05)$ and scheffe test was done where a significant difference exist. Correlation test was also done between ISQ value and the number of autoclave sterilization or reuse. Results: 1. In autoclave group, the means and sd. of ISQ value before autoclave sterilization were $84.97{\pm}0.41,\;84.93{\pm}0.74$ at direction a and b. There was significant differences between autoclave groups at direction a and b (P=.000). 2. In reuse group, the means and sd. of ISQ value before reuse were $85.40{\pm}0.62,\;85.50{\pm}0.57$ at direction a and b. There was no significant difference between reuse groups at direction a and b (P>.05). 3. There was a weak positive correlation between the number of reuse and ISQ value at direction a and b (${\gamma}=.207$ and .246, P<.01). Conclusion: Within the limitations of this study, the following conclusions were drawn. Till ninth reuse of $Smartpeg^{TM}$, the ISQ measurement stability did not be affected. After twice autoclave sterilization of $Smartpeg^{TM}$ the ISQ measurement stability was affected.

Comparison of Flexural Strength of Three-Dimensional Printed Three-Unit Provisional Fixed Dental Prostheses according to Build Directions

  • Park, Sang-Mo;Park, Ji-Man;Kim, Seong-Kyun;Heo, Seong-Joo;Koak, Jai-Young
    • Journal of Korean Dental Science
    • /
    • v.12 no.1
    • /
    • pp.13-19
    • /
    • 2019
  • Purpose: The aim of this study was to compare the flexural strength of provisional fixed dental prostheses which was three-dimensional (3D) printed by several build directions. Materials and Methods: A metal jig with two abutment teeth and pontic space in the middle was fabricated. This jig was scanned with a desktop scanner and provisional restoration was designed on dental computer-aided design program. On the preprocessing software, the build angles of the restorations were arranged at $0^{\circ}$, $30^{\circ}$, $45^{\circ}$, $60^{\circ}$, and $90^{\circ}$ and support was added and resultant structure was sliced to a thickness of $100{\mu}m$. Processed restorations were printed with digital light processing type 3D printer using poly methyl meta acrylate-based resin. After washing and post-curing, compressive loading was applied at a speed of 1 mm/min on a metal jig fixed to a universal testing machine. The maximum pressure at which fracture occurred was measured. For the statistical analysis, build direction was set as the independent variable and fracture strength as the dependent variable. One-way analysis of variance and Tukey's post hoc analysis was conducted to compare fracture strength among groups (${\alpha}=0.05$). Result: The mean flexural strength of provisional restoration 3D printed with the build direction of $0^{\circ}$ was $1,053{\pm}168N$; it was $1,183{\pm}188N$ at $30^{\circ}$, $1,178{\pm}81N$ at $45^{\circ}$, $1,166{\pm}133N$ at $60^{\circ}$, and $949{\pm}170N$ at $90^{\circ}$. The group with a build direction of $90^{\circ}$ showed significantly lower flexural strength than other groups (P<0.05). The flexural strength was significantly higher when the build direction was $30^{\circ}$ than when it was $90^{\circ}$ (P<0.01). Conclusion: Among the build directions $0^{\circ}$, $30^{\circ}$, $45^{\circ}$, $60^{\circ}$, and $90^{\circ}$ set for 3D printing of fixed dental prosthesis, an orientation of $30^{\circ}$ is recommended as an effective build direction for 3D printing.

Effects of Changes in Illumination Level and Slope on Fall-Related Biomechanical Risk Factors While Walking for Elderly Women (조도와 주로 변화가 노인 여성 보행 시 낙상 관련 운동역학적 위험요인에 미치는 영향)

  • Jeon, Hyun-Min;Park, Sang-Kyoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.25 no.4
    • /
    • pp.413-421
    • /
    • 2015
  • Objective : The purpose of this study was to investigate biomechanical changes of the lower limb including dynamic stability with changes in illumination (300Lx, 150Lx, and 5Lx) and slope (level and $15^{\circ}$ downhill) as risk factors for elderly falls. Method : Fifteen elderly females were selected for this study. Seven infrared cameras (Proreflex MCU 240: Qualisys, Sweden) and an instrumented treadmill (Bertec, USA) surrounded by illumination regulators and lights to change the levels of illumination were used to collect the data. A One-Way ANOVA with repeated measures using SPSS 12.0 was used to analyze statistical differences by the changes in illumination and slope. Statistical significance was set at ${\alpha}=.05$. Results : No differences in the joint movement of the lower limbs were found with changes in illumination (p>.05). The maximum plantar flexion movement of the ankle joints appeared to be greater at 5Lx compared to 300Lx during slope gait (p<.05). Additionally, maximum extension movement of the hip joints appeared to be greater at 5Lx and 150Lx compared to 300Lx during slope gait (p<.05). The maximum COM-COP angular velocity (direction to medial side of the body) of dynamic stability appeared to be smaller at 150Lx and 300Lx compared to 5Lx during level gait (p<.05). The minimum COM-COP angular velocity (direction to lateral side to the body) of dynamic stability appeared smaller at 150Lx compared to 5Lx during level gait (p<.05). Conclusion : In conclusion, elderly people use a stabilization strategy that reduces walk speed and dynamic stability as darkness increases. Therefore, the changes in illumination during gait induce the changes in gait mechanics which may increase the levels of biomechanical risk in elderly falls.