Comparison of Indoor Thermal Environments in Winter depending on Supply Vent Configurations (급기구 형상에 따른 겨울철 실내 온열환경의 비교)

  • Han, Hwa-Taik;Jeong, Young-Kyun
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.970-975
    • /
    • 2008
  • This study considers indoor thermal comfort in an ondol space by supply vent configurations to prevent cold draft in winter. A specially-designed vent cap has been investigated in comparison with a round pan-type vent and a simple opening without a cap. Numerical simulations have been conducted using CFD to analyze thermal comfort indices such as Predicted Mean Vote (PMV) and Effective Draft Temperature (EDT) as well as air distribution index i.e. Air Diffusion Performance Index (ADPI). Results show the new vent cap provides improved thermal comfort conditions especially near ondol heated floor, as the cold outdoor air spreads upwards along the vertical wall before reaching occupant region near floor. This paper includes discussions on the flow and comfort distributions created by the thermal jets from the vents.

  • PDF

An Experimental Study for Evaluating Performance of Radiant Floor Cooling System Integrated with Dehumidification (제습기능이 통합된 바닥복사 냉방시스템의 용 가능성에 관한 실험적 연구)

  • 이상엽;황석호;김가현;이승복
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.2
    • /
    • pp.143-152
    • /
    • 2002
  • It is critical for radiant floor cooling system using Ondol to cause condensation on a floor surface. To solve this problem, a radiant floor cooling system integrated with dehumidification was proposed and evaluated in terms of its applicability and prevention of condensation. Therresults show that the proposed system of radiant floor cooling integrated with dehumidification properly maintained the indoor setpoint temperatures and prevented the condensation on a floor surface. To achieve more stable indoor temperatures and humidity control, a further study for the operation of dehumidification panel will be needed.

Radiation Heat-Transfer Coefficient of the Indoor Surface in Ondol Heating Space (온돌난방공간(溫突暖房空間)의 내표면(內表面) 복사열전달률(輻射熱傳達率)에 관(關)한 연구(硏究))

  • Sohn, J.Y.;Ahn, B.W.;Shin, Y.T.
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.17 no.5
    • /
    • pp.598-606
    • /
    • 1988
  • The radiation heat-transfer coefficient is generally used to calculate radiant heat exchange of heating space. The coefficient is evenly adopted in most cases, but it is not correct in actual cases. The purpose of this paper is to grasp the changing aspect of radiation heat-transfer coefficient needed for heating load calculation of radiant heating space. Surface temperatures are measured in an Ondol space, and the coefficients are derived and examined. Gebhart's Absorption Factor Method is used for the calculations of the rates of instantaneous radiant exchange in the room. As the result, it is confirmed that the coefficients are variant according to surface temperatures, and proper coefficients are needed for each of conditions.

  • PDF

A Study on the Application of the Dehumidification System for Radiant Floor Cooling Using Ondol (온돌을 이용한 바닥복사냉방의 제습시스템 적용에 관한 연구)

  • 임재한;여명석;양인호;김광우
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.7
    • /
    • pp.607-616
    • /
    • 2002
  • This study has been conducted to evaluate the applicability of the control method in the dehumidification-integrated radiant floor cooling system in terms of stability of the room air temperature and the control variables through experiments. To do this, the relationship between the control variables in preventing floor surface condensation is first analyzed and the control method is predetermined through simulations. The results are as follows. First, it is necessary to determine the operation status of the dehumidification system according to the relationship between floor surface temperature and dew point temperature in the conditioned space. Second, outdoor reset with indoor temperature feedback control is better than on/off bang-bang control with respect to temperature stability in controlling the room air temperature and the possibility of energy savings. Finally, the humidity sensor can be located with the current thermostat in that there are small differences in absolute humidity in vertical distribution.

Simulation of the hot water ONDOL heating system by response factor method (應答係數法에 의한 溫水 溫室 暖房 시스템의 Simulation)

  • 조상준;민만기;최영돈
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.11 no.3
    • /
    • pp.409-424
    • /
    • 1987
  • Simulation on the hot water ONDOL heating system was made in order to investigate the variation of room temperature and specific fuel consumption of boiler. Heat balance equation was derived by response factors and solved implicitly. Variation of room temperature and specific fuel consumption of boiler were calculated with respect to the thickness of room floor, the absorptivity of wall for solar radiation, on-off temperature range of boiler and air exchange. The results show that specific fuel consumption of boiler is independent of the thickness of room floor and decreases with increasing the absorptivity of wall and on-off temperature range of boiler. However, it increases with increasing the air exchange. They also show that, when the absorptivity and on-off temperature range of boiler are increased, the amplitudes of room temperature variation increase.

A Study on the Application of the Radiant Floor Cooling System in Residential Building (주거 건물의 복사냉방시스템 적용에 관한 연구)

  • 임재한;여명석;김광우
    • Journal of the Korean housing association
    • /
    • v.15 no.3
    • /
    • pp.73-82
    • /
    • 2004
  • The objective of this study is to demonstrate the potential of radiant cooling systems using Ondol as an alternative cooling system in residential buildings. For this purpose, computer simulation and model experiments have been performed for the system performance analysis regarding comfort, floor surface condensation, and supply water temperature. The results of this study is the following: In radiant floor cooling system, room air temperatures were maintained within the set temperature range of $\pm$1$^{\circ}C$ without any discomfort condition. And taking into account only the condensation occurrence, it was possible to achieve radiant floor cooling for a period of about 77% of the total cooling period in weather condition of Seoul. The minimum supply water temperature is about 15$^{\circ}C$, so renewable energy system such as ground heat exchange system can be used as an alternative in cooling source. Also, floor surface condensation can be prevented by integrating with the dehumidification system.

Analysis of Ground Heat Loss in Ondol Heating Systems (온돌 난방에서의 지면을 통한 열손실)

  • Cho, Sung-Hwan;Kim, Kwan-Ho
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.7 no.3
    • /
    • pp.160-166
    • /
    • 1978
  • Heat loss to the ground in ondol heating system is analyzed mathematically using conformal mapping and variable transformations, Both two-and three-dimensional systems are analyzed. Heated house is assumed to be rectangular shape. Mean value of heat loss to the ground can be obtained using Figure 2. Effects of thermal parameters to heat loss are discussed. Numerical examples are also given.

  • PDF

Study on the Flow of Briquette Gas in the Ondol Heating System (Chimney Draft of Low Temperature Moist Air) (온돌의 연탄개스유량에 관한 연구(1) (함습저온열기류의 굴뚝통풍력))

  • Min Man-Ki
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.4 no.2
    • /
    • pp.119-128
    • /
    • 1975
  • Natural draft and flow which low temperature moist gas produces in the chimney of an Ondol heating system were numerically analysed. Among several factors involved inlet gas temperature has the strongest influence on the chimney performance and then next specific humidity of the gas. Thermal conductivity of the chimney wall, however, has little influence on the performance of such a low temperature chimney. Under given flow conditions there exists an optimum chimney height which gives a maximum flow rate for a given chimney diameter. This optimum value of chimney height inereases with increase in chimney diameter, inlet gas temperature and specific humidity.

  • PDF

A Study on the Analysis of Smart Ball Requirements for P-IPA-Based Ondol Pipeline Inspection (온돌 파이프라인 하자 점검용 스마트볼 요구사항 분석 연구)

  • Chun, Young-Hyun;Lee, Ung-Kyun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.333-334
    • /
    • 2023
  • Interest in the commercialization of research results is increasing according to the recent social atmosphere. In the field of construction, new technologies are also being actively commercialized. Pre-analysis of products is an important procedure for future market entry. This study aims to conduct a product-based importance-performance analysis as one of the preliminary analysis methods for the commercialization of technologies developed in the field of construction and to explore their applicability. This study conducts a survey on those involved by setting the categories of product quality, convenience, and usability for the commercialization of previously developed pipeline inspection product. Based on this, we would like to present an analysis that calculates importance and performance of the product and helps to set the development direction through interrelationship analysis.