• 제목/요약/키워드: ondol

검색결과 248건 처리시간 0.021초

온돌의 열효율에 관한 실험적 연구 (An Experimental Study on the Thermal Efficiency of the Ondol House Beating System)

  • 배순훈;강신형
    • 대한설비공학회지:설비저널
    • /
    • 제4권3호
    • /
    • pp.183-190
    • /
    • 1975
  • Most Korean houses are heated by the Ondol heating system. There has been, however, no reasonable design procedure availabe yet for the system. The conventional design should be improved to have auniform floor surface. temperature distribution and to have a high thermal efficiency. Thermal efficiencies of the ondol were defined and the method of experimentation was studied. An experiment, using a life-size model which was well insulated, was performed to observe the variation in thermal efficiency as the length of fuel burning time was varied.

  • PDF

건식이중바닥온돌시스템 개발을 위한 실험적 연구 (A Experimental Study for Developing of the Dry Double Floors Hydronic Ondol System)

  • 김난행;손장열
    • 한국주거학회논문집
    • /
    • 제17권3호
    • /
    • pp.1-7
    • /
    • 2006
  • The aim of the research was to evaluate the characteristics of thermal environment and thermal comfort in the Dry Double floors Hydronic Ondol System. Physical indoor thermal environments (the floor surface temperature, the vertical temperature, etc.) and skin temperature have especially been measured. Physical features conditions, sensation, thermal comfort, humidity sensation, comfort of body were investigated for the survey. As a result, (1) During the operation of the boiler (12 hour), the average indoor temperature is appeared to be $21.6^{\circ}C$. The floor surface temperature showed peak value of $31.4{\sim}40.6^{\circ}C$ after 8hours 30minutes after the start-point of the heating. The vertical difference of temperature was turned out to be not uniform. (2) While the skin temperature showed a narrow distribution of temperature in the Dry Double floors Hydronic Ondol system. (3) The response to thermal comfort which people felt was satisfactory, and most of them felt dry during the test.

2차원(次元) 온돌 상난방(床煖房)시스템의 연도내 열유동(熱流動) 및 열전달(熱傳達) 수치해석(數値解析) (Numerical Analysis of Heat Flow and Heat Transfer in Flue Channel of Two-Dimensional Ondol Panel Heating System)

  • 김영득;민만기;이상혁;김원갑
    • 설비공학논문집
    • /
    • 제6권4호
    • /
    • pp.337-343
    • /
    • 1994
  • Numerical analysis was applied to a simplified two-dimensional Ondol heating model which consists of heating space on the top of it along with radiant and convective heating floor panel, flue channel in the midway and rectangular underground soil region at the bottom. These three components constitute a system thermally coupled at the top and bottom interfaces of the flue channel. Investigated in the present paper are effects with variations of the Reynolds numbers of 100, 200, and 300, Grashof numbers of $0.1{\times}10^6$ and $0.3{\times}10^6$ and aspect ratios of 15 and 20 on the heat transfer and fluid flow characteristics of two-dimensional Ondol heating model by computer simulation.

  • PDF

독락당과 계정의 원형과 변화과정 연구 (A Study on the Original Form and Change of Dokrak-dang and Gye-jeong)

  • 김도경
    • 건축역사연구
    • /
    • 제23권5호
    • /
    • pp.23-36
    • /
    • 2014
  • Source criticism is very important on the research of architectural history as well as general history. In this point this research studied on the original form and change of Dokrak-dang that is very important building in architectural history of Korea. The result is as in the following. Dokrak-dang that Whoijae built at first was three by two kans size that had daecheong of four kans and ondol-bang of two kans. Gye-jeong that Whoijae built was three kans size that had daecheong of two kans and ondol-bang of one kan. After Whoijae died, Dokrak-dang's ondol-bang was changed to maru between 1555 and 1556 and ondol-bang in west side and stack room was added in 1630. Gye-jeong was changed to ㄱ-shaped floor plan that was added up two kans from three kan's 'ㅡ'-shaped one.

수치해석을 통한 구들의 열 흐름 특성 연구 (Heat Flow Characteristics of Traditional Ondol (Gudle) by Numerical Analysis)

  • 리신호;리광훈
    • 한국농공학회논문집
    • /
    • 제49권1호
    • /
    • pp.17-22
    • /
    • 2007
  • The heat flow characteristics of the Gudle (traditional Ondol) used a lot at farm houses have been performed with variations of Bunengki (Fireridge) by numerical analysis and field experiment. The Doedon-Gorae (Return-Firetunnel) Gudle is analyzed among the structure of Gudle. The distribution of heat flow in Gorse (Firetunnel) and the temperature distribution in floor of 3 Buneomgi (Fire ridge) was more uniform than that of 1 Buneomgi. The heat efficiency of 3 Buneomgi was higher than that of 1 Bunengki. That is, the 3 Bunengk is more efficient and more uniform temperature.

온돌을 이용한 복사냉방의 가능성에 관한 연구 (A study on the applicability of radiant cooling using Ondol)

  • 구소영;김용이;석호태;이현우;김광우
    • 설비공학논문집
    • /
    • 제12권2호
    • /
    • pp.200-208
    • /
    • 2000
  • The use of air-conditioning systems for cooling in residential buildings has negative effects on the environment and causes the problem in peak electric power demand in summer. The objective of this study is to demonstrate the potential of radiant cooling systems using ondol as an alternative cooling system in our residential buildings. Computer simulation has been performed for the floor radiant cooling system performance. The results of this study show that. 1) This system can control the temperature of Ondol room within comfort limits. 2) This system can be operated with a little risk of condensation but the control of latent heat will make this system more potential.

  • PDF

온돌면(溫突面)의 방열량(放熱量) 산정방법(算定方法)에 관한 연구(硏究) (A Calculation Method on Heat Flux from Ondol Floor Surface)

  • 손장열;안병욱;방승기
    • 설비공학논문집
    • /
    • 제1권2호
    • /
    • pp.173-181
    • /
    • 1989
  • Until recently there was a lack of reliable performance data for the design and operation of Ondol heating systems. This paper presents a calculation method on heat flux from Ondol floor surface. Total heat flux from floor consists of radiation and convection component. In order to analyse the characteristics of both radiation and convection heat flux, each surface temperature is measured and several temperatures near each wall are measured vertically and horizontally in a practical Ondol heating space. Radiation heat flux is calculated and analysed by Gebhart's Absorption Factor Method with the consideration of instantaneous radiant exchanges. Convection heat output is derived from the vertical temperature profiles near floor. The vertical temperature profiles could be expressed by nonlinear regression equation models and convection coefficients could be estimated by the equations. As a result, radiation, convection and total heat flux are suggested by the expression of difference between floor surface and room air temperature.

  • PDF

PCM을 이용한 온돌패널의 실험 및 특성연구 (Experiment and Property Study of Ondol Panel Based on Phase Change Material)

  • 윤두한;최봉수;홍희기
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.122-125
    • /
    • 2006
  • This paper deals with the Ondol, Korean under-floor heating system using latent heat storage materials. It has been recognized that the heating system using the latent heat storage materials are economically efficient and comfortable. For the comparison and analysis to the data of the existing experiment, a repetitive experiment makes sure the ability of Ondol panel.

  • PDF

박길룡의 주가(住家) 계획에서 온돌의 역할에 관한 연구 - 1926년부터 1941년까지의 계획안들을 중심으로 - (A Study of the Role of Ondol in Park Gil-ryong's Housing Design - Focused on the housing plans from 1926 to 1941 -)

  • 한장희;정인하
    • 대한건축학회논문집:계획계
    • /
    • 제36권1호
    • /
    • pp.69-80
    • /
    • 2020
  • The purpose of this study was to analyze the arrangement of rooms in Park Gil-ryong's housing plans to understand the influence of ondol on his design. Architect Park published diverse housing plans in Korean newspapers and magazines. Out of them, this study attempts to select the urban housing for the middle class as an object of analysis, and clarify the mutual relationship between the ondol and their room arrangement. This study is significant because it gives a precious opportunity to understand Park's ideas on housing improvement in the 1930s, and how his ideas affected other architects.

온돌 온열환경지표 평가방법 (Evaluation Methods on ONDOL Thermal Environmental Index)

  • 김성조
    • 한국산업융합학회 논문집
    • /
    • 제25권1호
    • /
    • pp.101-110
    • /
    • 2022
  • For this purpose, the authors proposed and proved usefulness of the modified mean skin temperature which is integrated mean radiation temperature and the effect of floor contacted heat conduction. The mean radiation temperature is applied form factor between half cross-legged human body and surrounding wall of indoor. In addition the floor contacted heat conduction is applied heat transfer coefficient of half cross-legged human body. Eight Korean young men were targeted for the experiment. From the experiment the authors excerpted physiological reaction and psychological reaction in Ondol environment which is combined physiccal environmental factor of artificial climate chamber, air and floor temperature. As a result of the experiment it is confirmed that heat conduction has more impact than heat exchange from existing research for the heat exchange between half cross-legged human body and surrounding wall in Ondol thermal environment. Thereby, it is proved the effectiveness of the modified mean skin temperature which is added floor contacted temperature to the Ondol thermal environmental evaluation index.