• 제목/요약/키워드: on-selective PVC membrane electrodes

검색결과 37건 처리시간 0.022초

Optimal Immobilization of Penicillinase for Ion-selective Electrode

  • Hur, Moon-Hye;Kang, Hee-Jin;Min, Hye-Young;Lee, Ji-Yeun;Lee, Ki-Hyun;Ahn, Moon-Kyu
    • Archives of Pharmacal Research
    • /
    • 제20권1호
    • /
    • pp.68-71
    • /
    • 1997
  • Penicillin sensor was prepared by immobilizing penicillinase (Pcase) on $H^{+}$-selective carboxylated poly (vinyl chloride) (PVC-COOH) membrane or cellulose filter membrane. The immobilization techniques are as follows. Pcase was immobilized with GTH on $H^{+}$-selective PVC-COOH membrane or some amount of BSA was dropped on that membrane. Another method to make immobilization is to mix type I Pcase with GTH and drop on a cellulose filter membrane. According to immobilization techniques, there were some differences in response properties of enzyme electrodes, however, all electrodes responded to Pcase-resistant penicillin derivatives. Pcase immobilized on cellulose filter membrane with $H^{+}$-selective PVC membrane eletrode was more stable and more sensitive to penicillinase-resistant penicillin derivatives than any other immobilization techniques.

  • PDF

Polymeric Membrane Cesium-Selective Electrodes Based on Quadruply-bridged Calix[6]arenes

  • 최은미;오혜진;고승화;최용국;남계춘;전승원
    • Bulletin of the Korean Chemical Society
    • /
    • 제22권12호
    • /
    • pp.1345-1349
    • /
    • 2001
  • New quadruply-bridged calix[6]arenes (I-V) have been studied as cesium selective ionophores in poly(vinyl chloride) (PVC) membrane electrodes. PVC membranes were prepared with dioctyl sebacate (DOS) or 2-nitrophenyl octyl ether (o-NPOE) as the sol vent mediator and potassium tetrakis(p-chlorophenyl)borate as the lipophilic salt additive. These ionophores produced electrodes with near-Nernstian slope. The selectivity coefficients for cesium ion with respect to alkali, alkaline earth and ammonium ions have been determined. The lowest detection limit (logaCs+ = -6.3) and the higher selectivity coefficient (logkpotCs+,Rb+ = -2.1 by SSM, -2.3 by FIM for calix[6]arene I) for Cs+ have been obtained for membranes containing quadruply-bridged calix[6]arenes (I, Ⅱ, Ⅲ), which have no para t-butyl substituents on the bridging benzene ring.

Lead-selective PVC Membrane Electordes Based on Bis(Crown ether)s

  • 오금철;강은철;정규성;팽기정
    • Bulletin of the Korean Chemical Society
    • /
    • 제20권5호
    • /
    • pp.556-558
    • /
    • 1999
  • Lead-selective PVC membrane electrodes based on newly synthesized bis(crown ether)s containing 18-crown-6 moiety was prepared using standard PVC membrane composition. In order to monitor lead in environmental samples by lead sensor, especially good selectivity over alkali and alkaline earth metals has to be obtained. Thus, responses of the PVC membrane prepared with new bis(crown ether)s and Fluka ionophore V (crown ether) base to various cations include lead, alkali and alkaline earth metal ions were investigated for their use as a lead sensor. The polymeric liquid membrane based on trans-1 8-crown-6 ether exhibits the best overall potentiometric performances as a lead-selective electrode in terms of a wide linear dynamic range (between 10-6 and 10-2 M, Pb2+), excellent detection limit (less than 10-6 M) and good durability within limited error. The preferences of lead over other cations, such as Ag+, Hg2+, Na+, Ca2+ and even K+ in the aforementioned electrode are much better than the Fluka ionophore V system.

Effect of Surfactants on the Electrochemical Performance of Cation-Selective Membrane Electrodes

  • Oh, Hyun-Joon;Cha, Geun-Sig;Nam, Hak-hyun
    • Bulletin of the Korean Chemical Society
    • /
    • 제24권1호
    • /
    • pp.37-44
    • /
    • 2003
  • We examined the effect of polyether-type nonionic surfactants (Brij 35, Triton X-100, Tween 20 and Tween 80) on the potentiometric properties of sodium-, potassium- and calcium-selective membranes which are prepared with widely used ionophores and four kinds of polymer matrices [poly(vinyl chloride) (PVC), polyurethane (PU), PVC/PU blend, and silicone rubber (SR)]. It was found that the PVC-based membranes, which provide the best performance among all other matrix-based membranes in the absence of nonionic surfactants, exhibited larger change in their potentiometric properties when nonionic surfactants are added to the sample solution. On the other hand, the sodium-selective SR-based membrane with calix[4]arene, potassium-selective PVC/PU- or SR-based membrane with valinomycin, and the calcium-selective SR-based membrane with ETH 1001 provide almost identical analytical performance in the presence and absence of Tween 20 or Tween 80 surfactants. The origin of nonionic surfactants effect was also investigated by interpreting the experimental results obtained with various matrices and ionophores. The results suggest that the nonionic surfactant extracted into the membrane phase unselectively form complexes with the primary and interfering ions, resulting in increased background potential and lower binding ability for the ionophore. Such effects should result in deteriorated detection limits, reduced response slopes and lower selectivity for the primary ions.

Potentiometric Characteristics of Ion-Selective Electrodes Based on Upper-Rim Calix[4]crown Neutral Carrier

  • 강유라;오현준;이경문;차근식;남학현;백경수;임혜재
    • Bulletin of the Korean Chemical Society
    • /
    • 제19권2호
    • /
    • pp.207-211
    • /
    • 1998
  • Potentiometric characteristics of DOS plasticized PVC-based membranes containing upper-rim calix[4]crown neutral carrier to various metal cations and protonated alkylamines have been examined. Although the calix[4]crown-based membrane electrodes exhibited substantial emf responses to alkali and alkaline earth metal cations, their high detection limits (- log[Cs+]=4.5) and sub-Nernstian response slopes (48 mV/pCs+) to the most selective cation, cesium, indicate that the metal cation complexing ability of calix[4]crown is much weaker than that of macrocyclic crown ethers. However, the calix[4]crown-based membrane electrodes exhibited near-Nernstian response slopes (56 mV/decade for hexylNH3+) with low detection limits (log[hexylNH3+]= - 6.7) to most alkylammonium ions compared to those of blank (DOS plasticized PVC membrane with no ionophore) or crown ether-based membranes. While the selectivity patterns of blank and crown ether-based membranes are determined primarily by the lipophilicity of alkylammonium ions, the membranes doped with calix[4]crown ionophore could effectively discriminate the steric shapes of nonpolar alkyl groups of alkylammonium ions.

이온 선택성 전극을 이용한 의약품 정량: Calix[4]arene과 Dibenzo-18-crown-6-ether에 의한 verapamil-선택성 polymeric membrane electrode (Ion-Selective Electrodes in Drugs Analysis: Verapamil-Selective Polymeric Membrane Electrodes Based on Calix[4]arene and Dibenzo-18-crown-6-ether Ionophores)

  • 이은엽;김성진;김영학;김재현;허문회;안문규
    • 약학회지
    • /
    • 제39권1호
    • /
    • pp.61-67
    • /
    • 1995
  • PVC membrane electrodes based on the lipophilic neutral carrier, dibenzo-18-crown-6, cyclic oligomers of teit-butylphenol-formaidehyde condensates, calix[4]arenes as the active sensors for verapamil have been prepared and tested in a variety of plasticizers. At pH 5.0, the electrode exhibits a Nernstian response in the range of 10$^{-2}$~5$\times$10$^{-5}$ M verapamil with a slope of 49.1$\pm$0.5mV per concentration decade. The electrode constructed in this work can be used continuously for at least 1 month before any damage to the membrane occurs. And the analyses of the local anesthetic amine, which are good to select a specific compound in a mixed solution, were also accomplished by using of another neutral carrier, a DB18C6, for comparing with calix[4]arene.

  • PDF

N,N,N,N-Tetrabenzylethylenediamine 중성운반체를 이용한 수소 이온 선택성 막전극 (A hydrogen ion-selective membrane electrode based on N,N,N,N-Tetrabenzylethylenediamine as neutral carrier)

  • 정성숙;박면용;정구춘;조동회;이경재;김재우
    • 분석과학
    • /
    • 제8권2호
    • /
    • pp.187-193
    • /
    • 1995
  • N,N,N,N-Tetrabenzylethylenediamine 중성운반체를 이용하여 PVC 수소이온 선택성 막전극을 제조하였다. 가소제 종류(phthalates와 sebacate) 및 친지방성 첨가제(NaTPB)에 따른 막전극의 전기저항과 수소이온 감응범위 및 알칼리금속과 알칼리토금속의 존재하에서 방해효과를 조사하였다. 가소제 종류에 의한 전기저항은 영향을 거의 받지 않았고 NaTPB 0.7%의 경우 수소이온에 대한 Nernstian 기울기는 가장 이론값에 근접하였으며, 또한 알칼리금속 및 알칼리토금속에 의한 방해도 적게 받았다. pH-선택성 고분자 막전극은 pH 2~10 범위내에서 선형적이고, 산과 알칼리용액 중에서 안정성 및 재현성 시험 결과 매우 좋게 나타났다.

  • PDF

이온교환체 이온선택성 전극을 이용한 염기성의약품 정량 (Determination of Basic Drugs with Ion-Selective Membrane Electrodes Using Ion-Exchanger)

  • 이지연;정문모;허문회;김은정;안문규
    • 약학회지
    • /
    • 제43권3호
    • /
    • pp.289-293
    • /
    • 1999
  • Many poly (vinyl chloride : PVC) membrane electrodes were investigated for the determination of basic drugs, chlorpromazine, amitriptyline, nortriptyline, etc. These electrodes are based on the use of the ion-association complexes of the basic drugs with eriochrome cyanine R, chromoxane cyanine, chrome azurol S and picric acid as ion-exchange sites in a plasticized PVC matrix. All ion-exchangers except picrate complex were not proper for use, because those complexes in plasticized membrane were excluded into aqueous working solution. These drug electrodes show excellent Nernstian responses in the concentration ranges $10^{-2}~10^{-6}$ mol $dm^{-3}$. Their selectivity with respect to each other, as well as their work-able pH range have been investigated. The major advantages of the proposed methods are their simplicity and speed.

  • PDF

중성운반체를 이용한 K+ 이온선택성 PVC막 전극 (K+ Ion-Selective PVC Membrane Electrodes with Neutral Carriers)

  • 김용렬;조경섭;강안수
    • 공업화학
    • /
    • 제9권5호
    • /
    • pp.734-741
    • /
    • 1998
  • 본 연구에서는 전극전위 분석법을 사용하여 중성운반체로 dibenzo-18-crown-6(D18Cr6)와 valinomycin(Val)을 이용하여 $K^+$ 이온선택성 PVC막 전극의 막과 용액계면에서의 전극특성을 검토하였다. PVC막에서 감응물질(운반체)에 기본전해질의 혼입 (doping)여부, 감응물질의 종류와 함량, 가소제, 막두께 및 이온의 활동도변화에 따른 전극의 기울기, 선형응답범위 한계측정농도 및 방해이온에 따른 선택계수 등 전극특성을 검토하였다. 중성운반체로 D18Cr6, Val을 $K^+$ 이온으로 착체형성하여 사용하였고, 가소제로 dibutylphthalate(DBP), dioctyl sebacate(DOS) 및 dibutyl sebacate(DBS)를, 혼입제인 기본전해질로 potassium tetraphenylborate (KTPB) 및 용매로 THF를 지지체로 PVC를 이용하여 막을 제조하였다. 운반체의 최적 함량은 D18Cr6와 Val의 경우 3.23 wt %이었고, 가소제는 DBP가 가장 적절한 가소제이었다. 막두께에 대한 영향은 최적 막두께 이상에서는 막두께가 얇아질수록 전극특성이 좋아졌으나, 막두께가 이 이하로 얇아지면 운반체의 용출, 막의 강도 등이 작용하여 전극특성이 나빠짐을 알 수 있었다. D18Cr6의 경우 $K^+$ 이온에 대한 혼합용액법에 의한 선택계수 서열은 다음과 같았다: $NH_4{^+}>Ca^{2+}>Mg^{2+}>Na^+$.

  • PDF

Polymeric Membrane and Solid Contact Electrodes Based on Schiff Base Complexes of Co(III) for Potentiometric Determination of Perchlorate Ions

  • Soleymanpour, Ahmad;Hanifi, Abdolghafoor;Kyanfar, Ali Hossein
    • Bulletin of the Korean Chemical Society
    • /
    • 제29권9호
    • /
    • pp.1774-1780
    • /
    • 2008
  • New PVC based polymeric membrane electrodes (PME) and coated glassy carbon electrodes (CGCE) based on synthesized Schiff base complexes of Co(III); [Co(Salen)$(PBu_3)_2$]$ClO_4$, [Co($Me_2$Salen)$(PBu_3)_2$]$ClO_4$, [Co(Salen)$(PBu_3)H_2O$]$ClO_4$; as anion carriers for potentiometric determination of $ClO_4\;^-$were studied. The PME and also CGCE electrodes prepared with [Co(Me2Salen)$(PBu_3)_2$]$ClO_4$ showed excellent response characteristics to perchlorate ions. The electrodes exhibited Nernstian responses to $ClO_4\;^-$ ions over a wide concentration range with low detection limits ($1.0 {\times} 10^{-6}\;mol\;L^{-1}$ for PME and $9.0 {\times} 10^{-7}\;mol\;L^{-1}$ for CGCE). The electrodes possess fast response time, satisfactory reproducibility, appropriate lifetime and, most importantly, good selectivity toward $ClO_4\;^-$ relative to a variety of other common inorganic anions. The potentiometric response of the electrodes is independent of the pH in the pH range 2.5-8.5. The proposed sensors were used in potentiometric determination of perchlorate ions in mineral water and urine samples. The interaction of the ionophore with perchlorate ions was shown by UV/Vis spectroscopy.