• 제목/요약/키워드: on-off circuit power

검색결과 354건 처리시간 0.026초

양극성 펄스 파워 모듈레이터의 파워셀 구동을 위한 게이트 드라이버 (Gate Driver for Power Cell Driving of Bipolar Pulsed Power Modulator)

  • 송승호;이승희;류홍제
    • 전력전자학회논문지
    • /
    • 제25권2호
    • /
    • pp.87-93
    • /
    • 2020
  • This study proposes a gate driver that operates semiconductor switches in the bipolar pulsed power modulator. The proposed gate driver was designed to receive isolated power and synchronized signals through the gate transformer. The gate circuit has a separate delay in the on-and-off operation to prevent a short circuit between the top and bottom switches of each leg. On the basis of the proposed gate circuit, a bipolar pulsed power modulator prototype with a 2.5 kV/100 A rating was developed. Finally, the bipolar pulsed power modulator was tested under resistive load and plasma reactor load conditions. It is verified that the proposed gate driver can be applied to a bipolar pulsed power modulator.

GTO 스너버 회로 설계에 관한 연구 (Design Considerations and Criteria of GTO Snubber Circuit)

  • 서재형;서범석;현동석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.376-378
    • /
    • 1994
  • The turn-off behavior of the GTO Thyristor by its nature differs very much from that of other power f semiconductor switching devices. So canful attention should be paid in designing the GTO snubber circuit. This paper presents the effect of turn-off snubber circuit elements on the switching characteristics of the GTO, and describes considerations and criteria for the selection of the snubber component values.

  • PDF

Active Clamping 방식을 이용한 전력용 반도체의 최적 직렬연결 방법 (Optimized Series Connection of Power Semiconductor Using Active Clamping Method)

  • 김봉석;고광철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2143-2145
    • /
    • 2005
  • Power semicondcutor인 IGBT MOSFET, GTO, SI-Thyristor등은 높은 스위치 신뢰성과 life time, 그리고 fast repetition rate 등을 지니고 있기 때문에 medium/High voltage영역에서 스위치 사용이 대두되어 왔으나, Thyratron이나 Trigatron(Gap switch)와 비교하여 낮은 전압/전류를 스위칭하기 때문에 전통적으로 직렬연결을 통해 high voltage 영역의 스위치로 사용되어 왔다. 하지만, 직렬연결되어 있는 각각의 power semiconductor와 gate driving circuit의 on/off synchronization이 맞지 않기 때문에 부하의 급격한 변화에 따른 전압의 balance에 문제가 가장 심각하게 대두되어 왔다. 이러한 문제를 해결하기 위해서 gate driving circuit에서 제어를 해주는 방법과 power semiconductor에서 제어를 해주는 방법이 있으나 두 방식 모두 문제점이 있다. 본 논문에서는 기존의 zener clamping방식에서 벗어나 새로운 active clamping방식의 직렬연결을 제안했으며 시뮬레이션과 실험을 통해 나타난 이 결과들은 on/off transient 시 symmetry를 유지하는데 효과적이라는 것을 보여주고 있다.

  • PDF

Resonant Pulse Power Converter with a Self-Switching Technique

  • Kim, Hyeok-Jin;Chung, Gyo-Bum;Cho, Jae-Ho
    • Journal of Power Electronics
    • /
    • 제10권6호
    • /
    • pp.784-791
    • /
    • 2010
  • In this paper, a resonant pulse power converter (RPPC) is proposed. The proposed RPPC transfers the pulse-shape power from a DC source to a load periodically. The RPPC consists of a resonant circuit and a resonant pulse converter driven by a self-switching circuit. Depending on the magnitude difference between the input and output voltages, the operations of the RPPC are divided into 4 modes; boost mode, hybrid mode, direct mode and cut-off mode, respectively. The main switch of the RPPC turns on in the ZCS condition and off in the ZVS condition spontaneously. The operational principles of a RPPC using the self-switching technique are analyzed and verified in experiments. An example of a RPPC application is demonstrated in the area of thermoelectric energy harvesting.

소프트 스위칭 기법을 이용한 1단 PFC-flyback 컨버터 (The Study on the One-stage PFC-flyback Converter using the Soft Switching Technique)

  • 이상혁;황정구;박성준
    • 전력전자학회논문지
    • /
    • 제18권3호
    • /
    • pp.263-269
    • /
    • 2013
  • The flyback converter has been applied widely in isolated DC/DC power converters because this converters employ a single MOSFET switch. The leakage inductance should be minimized for high efficiency of flyback converter. but in reality, it is very difficult. Namely, The Snubber circuit is essential to recover the leakage inductance stored energy when the switch is turn off. Flyback Converter typically operates in DCM mode and when switch is turn off in hard switching, this hard switching action results in a high power losses and switching stresses. In order to overcome these problems, a novel soft switching flyback converter using resonant snubber circuit is proposed in this paper. The resonant snubber circuit is composed of the transformer leakage inductance and a capacitor. To verify and confirm the proposed resonant snubber circuit, PSIM simulation and hardware prototype are implemented. Simulation and Experimental results indicate that the proposed resonant snubber circuit is effective.

PFC ZVT-PWM 승압형 컨버터에서 통합형 멀티칩 전력 모듈 제조를 위한 개선된 소프트 스위치 보조 공진 회로 (A Novel Soft Switched Auxiliary Resonant Circuit of a PFC ZVT-PWM Boost Converter for an Integrated Multi-chips Power Module Fabrication)

  • 김용욱;김래영;소재환;최기영
    • 전력전자학회논문지
    • /
    • 제18권5호
    • /
    • pp.458-465
    • /
    • 2013
  • This paper proposes a novel soft-switched auxiliary resonant circuit to provide a Zero-Voltage-Transition at turn-on for a conventional PWM boost converter in a PFC application. The proposed auxiliary circuit enables a main switch of the boost converter to turn on under a zero voltage switching condition and simultaneously achieves both soft-switched turn-on and turn-off. Moreover, for the purpose of an intelligent multi-chip power module fabrication, the proposed circuit is designed to satisfy several design constraints including space saving, low cost, and easy fabrication. As a result, the circuit is easily realized by a low rated MOSFET and a small inductor. Detail operation and the circuit waveform are theoretically explained and then simulation and experimental results are provided based on a 1.8 kW prototype PFC converter in order to verify the effectiveness of the proposed circuit.

New Zero-Current-Transition (ZCT) Circuit Cell Without Additional Current Stress

  • Kim, C.E.;Park, E.S.;G.W. Moon
    • Journal of Power Electronics
    • /
    • 제3권4호
    • /
    • pp.215-223
    • /
    • 2003
  • In this paper, a new zero-current-transition (ZCT) circuit cell is proposed. The main switch is turned-off under the zero current and zero voltage condition, and there is no additional current stress and voltage stress in the main switch and the main diode, respectively. The auxiliary switch is turned-off under the zero voltage condition, and the main diode is turned-on under the zero voltage condition. The resonant current required to obtain the ZCT condition is relatively small and regenerated to the input voltage source. The operational principles of a boost converter integrated with the proposed ZCT circuit cell are analyzed and verified by the simulation and experimental results.

Zero-Current-Switching in Full-Bridge DC-DC Converters Based on Activity Auxiliary Circuit

  • Chu, Enhui;Lu, Ping;Xu, Chang;Bao, Jianqun
    • Journal of Power Electronics
    • /
    • 제19권2호
    • /
    • pp.353-362
    • /
    • 2019
  • To address the problem of circulating current loss in the traditional zero-current switching (ZCS) full-bridge (FB) DC/DC converter, a ZCS FB DC/DC converter topology and modulation strategy is proposed in this paper. The strategy can achieve ZCS turn on and zero-voltage and zero-current switching (ZVZCS) turn off for the primary switches and realize ZVZCS turn on and zero-voltage switching (ZVS) turn off for the auxiliary switches. Moreover, its resonant circuit power is small. Compared with the traditional phase shift full-bridge converter, the new converter decreases circulating current loss and does not increase the current stress of the primary switches and the voltage stress of the rectifier diodes. The diodes turn off naturally when the current decreases to zero. Thus, neither reverse recovery current nor loss on diodes occurs. In this paper, we analyzed the operating principle, steady-state characteristics and soft-switching conditions and range of the converter in detail. A 740 V/1 kW, 100 kHz experimental prototype was established, verifying the effectiveness of the converter through experimental results.

낮은 입력 정재파비와 잡음을 갖는 수동 및 능동 바이어스를 사용한 저잡음증폭기에 관한 연구 (LNA Design Uses Active and Passive Biasing Circuit to Achieve Simultaneous Low Input VSWR and Low Noise)

  • 전중성
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권8호
    • /
    • pp.1263-1268
    • /
    • 2008
  • In this paper, the low noise power amplifier for GaAs FET ATF-10136 is designed and fabricated with active bias circuit and self bias circuit. To supply most suitable voltage and current, active bias circuit is designed. Active biasing offers the advantage that variations in the pinch-off voltage($V_p$) and saturated drain current($I_{DSS}$) will not necessitate a change in either the source or drain resistor value for a given bias condition. The active bias network automatically sets a gate-source voltage($V_{gs}$) for the desired drain voltage and drain current. Using resistive decoupling circuits, a signal at low frequency is dissipated by a resistor. This design method increases the stability of the LNA, suitable for input stage matching and gate source bias. The LNA is fabricated on FR-4 substrate with active and self bias circuit, and integrated in aluminum housing. As a results, the characteristics of the active and self bias circuit LNA implemented more than 13 dB and 14 dB in gain, lower than 1 dB and 1.1 dB in noise figure, 1.7 and 1.8 input VSWR at normalized frequency $1.4{\sim}1.6$, respectively.

2방향 전자밸브의 PWM 신호에 의한 압력제어 특성 (Pressure Control Characteristics of a 2-Way Solenoid Valve Driven by PWM Signal)

  • 정헌술;김형의
    • 대한기계학회논문집A
    • /
    • 제26권8호
    • /
    • pp.1565-1576
    • /
    • 2002
  • By way of driving a 2-way on/off solenoid hydraulic valve with a pulse width modulation (PWM) signal, control of the pressure in a certain volume is frequently used in various applications. However, the pressure built-up according to the duty ratio and carrier frequency of the PWM signal is not so well understood. In order to clarify the characteristics of 2-way valve hydraulic pressure control systems, in this paper two formula fur the mean and ripple of the load pressure were derived through theoretical analysis. And the accuracy of the derived formula were verified by comparison with the experimental test result. Generally 2-way valve systems are constructed as a bleed-off circuit, while 3-way valves are used as a control element in a meter-in circuit pressure control system. In a bleed-off circuit, the system supply pressure from a hydraulic power pack does not remain constant, but changes according to their external load. In turn, the relief valve in the hydraulic power pack reacts accordingly showing complicated dynamic behavior, which makes an analytical study difficult. In order to resolve the problem, simple but accurate empirical dynamic models fer a bleed-off system were used in the course of formula derivation. As the result, selection criteria for two major control parameters of the driving signal is established and the basic strategy to suppress the unnecessary pressure fluctuation can be provided for a hydraulic pressure control system using a 2-way on/off solenoid valve.