• Title/Summary/Keyword: on-line test

Search Result 3,406, Processing Time 0.03 seconds

A Study on the Assembly Line Design Tool with a Pre/Post Process (전후 처리 기능을 포함하는 조립라인 설계 방법론)

  • Moon, Byoung-Hoon;Choi, Seong-Hoon
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.37 no.4
    • /
    • pp.98-105
    • /
    • 2014
  • According to a simple survey on the current status of the assembly line design, it was found that trial and error methods on the basis of experiences have been used mainly in domestic manufacturing industries, even though there exist a lot of excellent line balancing studies. It seems that more practical researches should be carried out to develop user-oriented line balancing tools especially for small and medium-sized enterprises. This study presents a design of the line balancing tool which can support the line balancing tasks of nonspecialists. The proposed design tool is composed of three major modules: pre-process, line balancing, and post-process. In particular, pre-process and post-process are newly proposed to increase its ease of use. We applied the proposed design to a test problem and test result showed that our practical method may contribute to enhance the efficiency of production operations management.

Parallel Testing Circuits with Versatile Data Patterns for SOP Image SRAM Buffer (SOP Image SRAM Buffer용 다양한 데이터 패턴 병렬 테스트 회로)

  • Jeong, Kyu-Ho;You, Jae-Hee
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.9
    • /
    • pp.14-24
    • /
    • 2009
  • Memory cell array and peripheral circuits are designed for system on panel style frame buffer. Moreover, a parallel test methodology to test multiple blocks of memory cells is proposed to overcome low yield of system on panel processing technologies. It is capable of faster fault detection compared to conventional memory tests and also applicable to the tests of various embedded memories and conventional SRAMs. The various patterns of conventional test vectors can be used to enhance fault coverage. The proposed testing method is also applicable to hierarchical bit line and divided word line, one of design trends of recent memory architectures.

Test on Characteristics of Delta Conversion UPS System (델타변환 무정전전원장치 시스템의 특성 시험)

  • Ji Jun-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.6 no.6
    • /
    • pp.491-496
    • /
    • 2005
  • In this paper, test on characteristics of 3-phase line-interactive UPS system, known as delta conversion UPS system, is studied. Delta conversion UPS system is new line-interactive UPS system using two series-parallel PWM converters instead of using series inductor in conventional single conversion line-interactive UPS system. It is known that the characteristics of input and output in delta conversion UPS system is much improved by controlling source current of AC lines directly. Here the results on load test, normal/backup mode test, and normal/bypass mode test, which are very important in the test on characteristics of UPS system, is presented. And finally overall evaluation on delta conversion UPS system is given.

  • PDF

A Study on the Dynamic Characteristics on the Test Line for Korean High Speed Train (한국형 고속전철의 주행진동 특성에 관한 연구)

  • 김영국;김석원;박찬경
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.555-560
    • /
    • 2003
  • Korean High Speed Train(KHST) has been tested on the high speed test line in Osung site of Korea High Speed Rail Construction Authority (KHRC). since it was developed as G7 Project Plan In 2002. This paper introduces the dynamic test devices in KHST and shows the comparison between the results of test and theoretical computing results which derive from the new model for KHST dynamic behavior. Previous computer simulation model for KHST was developed to review wether the vehicle system was satisfied with the dynamic performance requirements during the design procedure. But It should be applied the results of the parts test for suspension elements in order to compare between the results of computation and real test. Using VAMPIRE Program made by AEA Technology in UK. the new model also was modified. This paper shows that the static wheel loads calculated from new model is similar to test results. For test on high speed line, we prepared the test devices for evaluating the dynamic performances. which was consisted of the accelerometers( based on Kisler Co.) and the data aquisition systems (based on National instrument Co.), and test program coded by LabView 6i program. These lest devices and programs are flexible to extension the channels for adding sensors and connect to the ethernet network. The acceleration of car bodies, bogie frames and axle boxes were compared between the results of computation and test at 150km/. This paper shows that the results of test were high in high frequency band range but similar frequency band range. It might be considered that these differences were caused by the test which did not performed at constant speed for comparison analysis. Also. It will be able to understand the differences and make better results through a lot of tests planed in future.

  • PDF

Speed Up Test on conventional Line by using Korean High Speed Train(HSR-350x) (한국형 고속 전철을 활용한 기존선 속도향상 고찰)

  • Kim Ki-Hwan;Park Choon-Soo;Kim Seok-Won
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.334-338
    • /
    • 2004
  • KTX has started commercial service from Seoul to Busan and Mokpo since April 1, 2004. The service line is composed of new-high speed line and conventional line. Before KTX is runs, the maximum operational speed on conventional line was 140km/h. In order to reduce the traveling time, operation speed of KTX must be increased on the conventional line. So, we performed test running with prototype HSR-350x and verification of safety was made in $10\%$ speed-up. Korean High Speed Train HSR-350x) was developed by G7 - R&D project. In this study, in safety aspect, several technical reviews are introduced and the possibility for reduction of traveling time is investigated on the conventional line by using HSR-350x.

  • PDF

Considerations on the Long-term Reliability of On-line Partial Discharge Ceramic Sensor for Thermal Power Generators and its Demonstration in the Field

  • Sun, Jong-Ho;Youn, Young-Woo;Hwang, Don-Ha;Kang, Dong-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.1
    • /
    • pp.103-108
    • /
    • 2012
  • The present study describes the considerations on the long-term reliability of the on-line partial discharge (PD) ceramic sensor for thermal power generators. Voltage acceleration aging tests were carried out under continuous and impulsive thermal aging at more than $100^{\circ}C$, considering the practical service environment. Experimental results show that the sensors have a life that could last for more than 100 years, excellent dielectric characteristics, and insulation strength. In addition, the ceramic on-line PD sensors were installed in a thermal power generator in Korea for demonstration. The results of the PD calibration and test voltage application prove that the on-line ceramic sensors have satisfactory performances for on-line PD measurement.

Verification of Underground Distribution Line Modeling with Field Test (실증시험을 통한 지중배전선로 모델링 기법 검증 연구)

  • Yun, Chang-Sub;Lee, Jae-Bong;Kim, Byong-Suk;Lee, Jong-Beom
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.12
    • /
    • pp.2091-2097
    • /
    • 2007
  • This paper described the verification of modeling technique of underground distribution from comparison between field test and simulation. It needs more exact transient phenomenon analysis model to establish lightning protection of underground distribution line. Although, there were a lot of transient phenomenon researches, nobody could has verified the confidence of modeling from field tests in interior until now. So, simulation model verified field test is needed to analyse transient phenomenon of underground distribution system. The examination must be accomplished in many different condition before suggesting these verified analysis model. In this paper, the conditions were examined and the various data results on the different line composition was compared with the EMTP simulation, when the lightning impulse test was accomplished at underground distribution line. Also the value between field test and simulation was very closed and the method of modeling has demonstrated confidence, when the method is used to analyse domestic transient phenomenon of underground distribution.

Performance Analysis of Laboratory and Field Luminance for Phosphorescent Line Marking and Preliminary Study of Luminance Analysis Using Digital Images (축광노면표시의 실내 및 현장 휘도 성능분석과 디지털이미지를 이용한 휘도분석 사전연구)

  • Kim, Sang Tae;Lee, Yong Mun;Kim, Heung Rae;Choi, Kee Choo
    • International Journal of Highway Engineering
    • /
    • v.18 no.6
    • /
    • pp.145-152
    • /
    • 2016
  • OBJECTIVES : Visibility at night can be improved by using retroreflection for short distances and phosphorescent line markings for long distances. In this study, we analyzed the characteristics of the phosphorescent line marking through a laboratory luminance test. Field performance analysis was performed through tests conducted on the road. We also examined the luminance measurement methods using the digital image obtained during the phosphorescent visibility evaluation. METHODS : In this study, the laboratory luminance test of the phosphorescent line marking was conducted using seven specimens to characterize the luminance changes according to the type of the glass beads, the thickness of the phosphorescent line marking, and the brightness and irradiation time of the light source. Phosphorescent and general line markings were made at 150 m to investigate the field luminance performance. A preliminary review of the luminance measurement methods was made using a digital image from a digital single-lens reflex (DSLR) camera. The measured luminance ratio of the general and the phosphorescent line markings was compared with the calculated luminance ratio using luminance analysis. RESULTS : Through the laboratory luminance test, it was seen that the change in luminance, which corresponds to the brightness of the light source, appears large but the influence of the thickness and irradiation time is low. The field performance test of the phosphorescent line marking conducted on the road involved measuring the luminance on the day the marking was made and 7 days after the marking was made. The luminance was found to be $190mcd/m^2$ at 30 min after sunset and approximately $10-12mcd/m^2$ 4h after sunset. The results of the luminance test were captured using a digital image for each time group. The luminance ratio of the phosphorescent line marking, when compared to that of the general line marking, showed a similar trend within a 13% maximum error. Additionally, when this luminance ratio is compared to the direct field measurement, it could be confirmed that the luminance ratio, as captured in the digital image, showed a similar tendency. CONCLUSIONS : 1) The change in luminance corresponding to the brightness of the light source is significant in comparison with that corresponding to the thickness and the irradiation time. In addition, the results of the field test for the phosphorescent line marking satisfied the phosphorescent fire protection standard. 2) We examined the validity of the luminance measurement method using a digital image and we concluded that the change in the luminance ratio shows a similar tendency in both the cases. The results can form the basis for luminance measurement methodology for the construction and maintenance of phosphorescent line markings.

Evaluation of Behaviors on Mooring Line Embedded in Sand Using Centrifuge Test (원심모형실험을 이용한 모래지반에 관입된 계류선 거동 평가)

  • Lee, Hoon Yong;Kim, Surin;Kim, Jaehyun;Kim, Dong-Soo;Choo, Yun Wook;Kwo, Osoon
    • Journal of Ocean Engineering and Technology
    • /
    • v.28 no.1
    • /
    • pp.47-54
    • /
    • 2014
  • When an anchor penetrates and is installed under a seabed, a portion of the mooring line connected to the anchor is also embedded under the seabed. This embedded mooring line affects the capacity of the anchor in two ways. First, the frictional resistance that occurs between the mooring line and the seabed reduces the pulling force acting on the anchor. Second, the embedded part of the mooring line forms a reverse catenary shape due to the bearing resistance of the soil, so that an inclined pulling force is applied to the anchor. To evaluate the mooring line's effect on the capacity of an anchor in sand, centrifuge model tests were performed using two relative sand densities of 76% and 51% while changing the anchor depths. The test results showed that the load is reduced much more in deep and dense sand, and the inclination angle of the load is lower in shallow and loose sand.

Effect of Distance Phoria on Stereoacuity (원거리 사위도가 입체시에 미치는 영향)

  • Chun, Young-Yun;Joo, Seok-Hee;Park, Seong-Jong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.1
    • /
    • pp.101-105
    • /
    • 2008
  • Purpose: In this study we measured the mean value of the distance stereoacutiy for adult subjects and evaluated the variation of the distance stereoacuity according to correction of phoria using the Pola Test E-II of Carl Zeiss. Methods: We investigated the distance stereoacuity for 50 adults (male: 29, female: 21) ranging in age from 19 to 46 years using D6 Circle chart and D8 Line chart in the Pola Test E-II. Results: The mean values of the distance stereoacuity measured on the D6 Circle test and D8 Line test were 159.6 and 149.4 seconds of arc respectively. The mean variations of the distance stereoacuity according to correction of phoria in D6 Circle test were increased 43.2 seconds of arc in exophoria and 51 seconds of arc in esophoria, and those in D8 Line test were increased 42 seconds of arc in exophoria and 70.2 seconds of arc in esophoria. Conclusions: We knew from these results that the distance stereoacuity after prescription of phoria improved more esophoria than exophoria.

  • PDF