• Title/Summary/Keyword: on-line test

Search Result 3,406, Processing Time 0.032 seconds

A Study on Overall Measurement System Development of HEMU-400X Performance Test (차세대고속열차 성능시험을 위한 종합계측시스템 개발 연구)

  • Lee, Young-Yeob;Ryu, Sang-Hyun;Kim, Bong-Rae;Kim, Kyung-Taek
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.1118-1123
    • /
    • 2011
  • The introduction of high speed railway(KTX) in Korea after the Korean high speed train through the KTX-II of the development is being run is made. Thus the demand for the railway technology advances and high performance, Korean government promoted the development of the next-generation high speed train system(HEMU-400X). In addition to the production of train system essential element of the train through an on-line test is to evaluate the performance. Through the on-line test of the train in order to evaluate the performance test items should be selected first and need to the test procedures are required. In addition, an Overall Measuring System(OMS) to measure the performance of the train system should be established. In this study for the on-line test of the HEMU-400X test items was selected for detailed measurements and performance evaluation of a comprehensive and efficient trains to test an OMS for the development are discussed.

  • PDF

A Study on OLED display device's line defect test methode (OLED display device의 Line Defect 시험법에 관한 연구)

  • Choi, Young-Tae;Choi, Jai-Rip
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2009.04a
    • /
    • pp.523-529
    • /
    • 2009
  • The ACF(Anisotropic Conductive Film) is used for bonding Drive IC and OLED display device panel. If ACF bonding process is problem, a malfunction of line defect can occur. Because electric resistance increase between the panel and drive IC after a period of time, drive IC can not supply enough current to the panel. This paper is studied on a method of test for line defect.

  • PDF

Estimation of Straight Line Stability of a Damaged Surface Combatant through Spiral Maneuver Test Model Considering Asymmetry (비대칭성이 고려된 나선형 시험 모델을 통한 손상 수상함의 직진 안정성 추정)

  • Ha, Jeong Soo;Jeong, Yeon Hwan
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.16 no.2
    • /
    • pp.110-117
    • /
    • 2020
  • In this paper, we estimated the straight line stability by performing a 3 degree of freedom spiral test simulation of a intact/damaged surface combatant using the hydrodynamic coefficient obtained through the PMM(Planar motion mechanism) test based on system engineering process. A model ship was ONR Tumblehome and damaged compartment was set on the starboard bow. As a result of conducting a spiral test simulation based on the experimental results of J.Ha (2018), the asymmetric straight line stability due to the damaged compartment was confirmed. In the case of a ship in which the starboard bow was damaged, it was confirmed that it had the characteristic to deflect to the left when going straight. Also, when estimating the straight line stability of a both port and starboard asymmetric surface combatant, a separated equation of motion model that sees the port and starboard as different ships seems suitable.

Study on Electrical Environmental Obstacle Using a 765kV Double Circuit Test Line (765kV 시험선로를 이용한 전기환경장해 특성연구)

  • Kim, Jeong-Boo;Jo, Seong-Sae;Shin, Goo-Yong;Lee, Dong-Il;Yang, Kwang-Ho;Ahn, Hee-Sung;Bae, Jeong-Hyo;Koo, Ja-Yoon;Min, Seok-Weon
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1517-1519
    • /
    • 1994
  • This paper describes electrical environmental study of a 765kV double circuit test line. Corona performance on several candidate conductor bundles has been investigated in the corona cage (single phase simulation facility) since 1984. We have known that six RAIL conductor bundle is the most suitable for the 765kV transmission Line, [3] To investigate electrical environmental impact of the future commerciale line, we build a full sacle 765kV test line in 1993. The test results of Audible Noise, Radio Interference, TV Interference from August, 1993 to Jan. 1994 were measured as $48.7[dBA](L_{50})$. $57.4[dB{\mu}V/m]$(Fair weather, $L_{50})$. $14.5[dB${\mu}$V/m]$(Fair weather, $L_{50}$). We have found that the Audible Noise data were very close to the predicted(48.5 [dBA]) by BPA Corona and Field Effects Computer program, however, the RI and TVI data were much higher than predicted(42 [dBmV/m], $7.9[dB{\mu}V/m)$ by the BPA program. We have investigating the reason of the difference. In the constructing of full scale test line, we developed the tubular tower, 765kV test transformer and hardwares of 765kV transmission line insulator strings. Also we will investigate the effects of plants under the 765kV test Line.

  • PDF

Development of Bending Fatigue Test System for Trolley Line Simulating Real Conditions (실사용조건을 모사한 전차선 굽힘피로 특성평가 시스템개발)

  • Kang, Min-Sung;Ahn, Sang-Soo;Koo, Jae-Mean;Seok, Chang-Sung;Lee, Ki-Won;Cho, Yong-Hyeon
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.3059-3064
    • /
    • 2011
  • A Trolley line is a very important equipment among electric railway equipments since it contacts directly with pantograph and supplies electricity on the electromotive. Such it was thought that a trolley line need not to consider fatigue since the replace cycle by wear is shorter than the replace cycle by fatigue breakage. But, the bending fatigue breakage accidents occurred several times at the Shinkansen trolley line in East Japan Railway Company. Therefore, in case of a new developed trolley line, the evaluation for bending fatigue life became more important, But, since there are not an authorized fatigue test method and a testing device for the trolley line, the quantitative evaluation is difficult. In this study, we analyzed the load and environment condition of trolley line used in the actual spot and the developed testing device that can evaluate bending fatigue properties of the trolley line as simulating the real condition. The bending fatigue test of the trolley line was achieved using the developed testing device and estimated the fatigue life of trolley line and also, established the fatigue test process.

  • PDF

A Evaluation of Maintenance History for K-AGT (한국형 경량전철시스템의 유지보수 이력에 대한 평가)

  • Lee, Ho-Yong;Ryu, Sang-Hwan;Cho, Hong-Shik;Cho, Bong-Kwan;Jang, Yul
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.1014-1023
    • /
    • 2008
  • The K-AGT test line is managed similarly to revenue operation and operated automatically 120km per day, total 90,000km from August 2004 to December 2007. To enhance reliability of developed system, maintenance information system based on RCM is applied. The maintenance program applied in test line is based on RCM which prevent a fault before it happens and a fault made in test line is analysed by reliability growth test. Vehicle system, power supply system, signalling system, track and infrastructure are built in test line and it is reviewed enhancing system performance and changing designs to commercialize through reliability growth analysis method.

  • PDF

An evaluation on 100,000km endurance test for the Korean EMU (표준전동차 10만km 내구도 시험평가)

  • 정종덕;김원경;한석윤;이호용;안태기;한성호
    • Proceedings of the KSR Conference
    • /
    • 2002.05a
    • /
    • pp.336-343
    • /
    • 2002
  • This paper describes the result of endurance test on the Sangju test track. The purpose of the test is to prove the endurance of the Korean EMU for the commercial operation. Test conditions are more severe than actual operation on the commercial line. But endurance test come to an end well without severe problem. Hereafter, Korean EMU will be applied the quality certification of railroad supplies as a testing vehicle and their components will be applied in a new line.

  • PDF

A study of the harmonics evaluation in the test track of Korea High Speed Rail (경부고속철도 시험선구 고조파 예측에 관한 연구)

  • 김길상;오광해;권삼영;이태형
    • Proceedings of the KSR Conference
    • /
    • 1998.11a
    • /
    • pp.241-248
    • /
    • 1998
  • The purpose of this study is to evaluate the harmonics generated from Korea High Speed Rail's trainset and to analyze the effect on the KEPCO power system. This study focuses on the test track of the high speed rail and analyzes 154㎸ transmission line, scott transformer, autotransformer and 27,5㎸ line. The trainset is modeled as a harmonic source attached to the catenary line of the test track. Then, harmonic distortion is calculated. This distortion is compared with the KEPCO's regulations in relation to harmonic.

  • PDF

A Study of the Development of Power System Model for Performance Test of Transmission Line Protective Relay (송전선로 보호용 보호계전기 시험을 위한 계통모델 개발에 관한 연구)

  • Seo H. C.;Lee H. H.;Kim C. H.;Lee J. W.;Jang B. T.;Gwak N. H.;Kim H. P.;Kim l. D.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.430-432
    • /
    • 2004
  • The standard power system model is needed to test a transmission line protective relay There are two methods to develop a power system model for transmission line protection. First method is based on characteristic power system model, and second method is based on functional power system model. This paper presents a standard power system model for performance test of transmission line protective relay, where the power system model is based on the two methods. And this model is simulated by using RTDS to test a protective relay.

  • PDF