• 제목/요약/키워드: on-line monitoring of drinking water

검색결과 7건 처리시간 0.026초

수돗물 위해요소 리스크 관리를 위한 물안전계획 적용 연구 (A study on the application of water safety plans for the hazard risk management of tap water)

  • 김진근;김두일
    • 상하수도학회지
    • /
    • 제33권4호
    • /
    • pp.259-268
    • /
    • 2019
  • One of the most effective methods to consistently ensure the safety of a tap water supply can be achieved by application of a comprehensive risk assessment and risk management approach for drinking water supply systems. This approach can be termed water safety plans(WSP) which recommended by WHO(world health organization) and IWA(international water association). For the introduction of WSP into Korea, 150 hazards were identified all steps in drinking water supply from catchment to consumer and risk assessment tool based on frequency and consequence of hazards were developed. Then, developed risk assessment tool by this research was implemented at a water treatment plant($Q=25,000m^3/d$) to verify its applicability, and several amendments were recommended; classification of water source should be changed from groundwater to stream to strengthen water quality monitoring contaminants and frequencies; installation of aquarium to monitor intrusion of toxic substances into raw water; relocation or new installation on-line water quality analyzers for efficient water quality monitoring; change of chlorination chemical from solid phase($Ca(OCl)_2$) to liquid phase(NaOCl) to improve soundness of chlorination. It was also meaningful to propose hazards and risk assessment tool appropriate for Korea drinking water supply systems through this research which has been inconsistent among water treatment authorities.

정수장 응집제주입 최적화를 위한 플럭 모니터링 (Optimum Coagulation of Water Treatment Plant using On-line Floc Monitoring System)

  • 황환도;임상호;성규종;한영진;김영범;곽종운
    • 상하수도학회지
    • /
    • 제23권4호
    • /
    • pp.397-406
    • /
    • 2009
  • This study was conducted to monitor the floc sizes forming in the mixing zone in the water treatment plant. The dosing amount of poly aluminium chloride(PAC) was determined by particle dispersion analyzer(iPDA) in the lab and field scale test. During a field test period, PAC coagulant was used and the raw water was taken from Nakdong river. PAC wad diluted to activate the coagulant, leading to bring the more homogeneous dispersion in the shorter time. To monitor the floc sizes, the unit of floc size index(FSI) was used. With increasing of raw water turbidity, FSI value was increased. Also, the increased dosing amount of PAC brought the increased FSI and with overdosing of coagulant was in turn decreased. When the PAC was fed into the raw water after dilution in a field scale test, the width of FSI was narrower compared with the feeding of the mother liquor of PAC, implying that the formed flocs are denser and more uniform sizes. The width of FSI in average was varied on depending on the basicity of coagulant. Also, dF value, fractal dimension was evalued with the different coagulants, showing from 2.01 to 2.03. On-line floc monitor was effective for the optimal dosing in the drinking water plant.

음용수 중 수은 연속자동측정시스템의 개발에 관한 연구 (Fundamental Studies on the Development of On-line Monitoring of Trace Mercury in Drinking Water)

  • 장수현;김효진;김선태;김영만
    • 분석과학
    • /
    • 제12권4호
    • /
    • pp.299-305
    • /
    • 1999
  • Electrolyte as cathode glow discharge(ELCAD)는 용액 중에 포함된 미량 중금속을 연속 자동 측정하기 위한 새로운 플라스마 source로서 주로 원자방출법에 의하여 원소들을 측정한다. 그러나 수은의 경우 원자 방출법보다는 원자 흡수법을 주로 적용한다. 본 연구에서는 기존의 원자흡수분광기의 원자화부분을 ELCAD cell로 대치하여 원자흡수법에 의하여 수은을 측정하였다. 일반적으로 원자방출법에 의하여 원소들의 방출선측정시 용액의 pH가 1.0에서 가장 안정한 플라스마와 가장 큰 방출세기를 나타내었으나 수은인 경우 pH 3.0에서 가장 흡광도가 높았다. 그러나 플라스마의 안정도는 pH가 1.0 일 때가 가장 좋은 관계로 흡광도의 % RSD 값은 pH 1.5 용액에서는 0.35% 이었으며 pH 3.0인 검액에서는 3.6%를 나타내었다. 두 검액에 대해 각각 검량곡선을 작성하였을 때 모두 양호한 직선성을 보였으며, 각각의 검출 한계를 구한 결과, pH 1.5 용액은 약 40 ppb, pH 3.0 용액은 10 ppb level 이었다.

  • PDF

입자계수기를 이용한 생물활성탄 공정의 효율평가 (Evaluation of Biological Activated Carbon Using Particle Counter)

  • 김희근;류동춘;김현실;류병순;문성용;김승현;김원경
    • 상하수도학회지
    • /
    • 제20권6호
    • /
    • pp.823-828
    • /
    • 2006
  • For this study, an online particle counter was installed before and after the activated carbon filtration process of D water treatment plant where has advanced water treatment processes, produces average 900,000ton/day of drinking water and supply the produced drinking water to Busan citizens. We collected and analyzed particle count data for about 1 year. We inspected particle breakthrough in three out of sixteen filter processes operated at same conditions, i.e. 5th filter, 6th filter and 7th filter. According to the monitoring results, 6th and 7th filters showed similar results while 5th filter showed different results. When compared seasonal effect, the particle count for dry season was below 10 particles/ml while the particle count for August when monthly average rainfall is over 200mm was much higher than for dry season. In January and August, there was a difference in breakthrough particle size. In January, small particles in 2~3um were mainly detected while in August 10um particles were mainly detected and the size distribution was 40% of total count.

배급수 계통에서 부식억제제 적용에 따른 부식과 적수와의 상관관계 (Correlation between Corrosion Rate and Red Water on Application of Corrosion Inhibitor in Drinking Water Distribution System)

  • 우달식;구성은;이병두;김주환;문광순
    • 상하수도학회지
    • /
    • 제19권1호
    • /
    • pp.68-77
    • /
    • 2005
  • This study was performed to evaluate the application of corrosion inhibitor and to examine the correlation between corrosion rate and red water in a series of batch tests and a test using auto corrosion monitoring system at A water treatment plant in Gyeonggido. The corrosion study in the auto corrosion monitoring system indicated that Fe concentration decreased by 30~50% and corrosion rate also reduced remarkably with corrosion inhibitor at $1.8mg\;PO_4/L$. After addition of corrosion inhibitor, it was indicated the effective adsorption of the inhibitor on the surface of the pipe line forming a protective film. The corrosion rate increases with the increase in Fe concentration. With $1.8mg\;PO_4/L$ of corrosion inhibitor, the corrosion rate decreased remarkably. Fe concentration had correlation to not only red water problems but also the corrosion rate that actually dissolved into the water, primarily due to the deposition of oxidized iron or other compounds as a scale, which serves as a large reservoir of corrosion by-product. Therefore, corrosion rate can be estimated by Fe concentration. For these reasons, an effective corrosion inhibitor is also an effective red water control reagent. The effect of the corrosion inhibition can last for some time even the application the corrosion inhibitor is discontinued. For the cost effective and efficient corrosion control, the concentration and timing of corrosion inhibitor addition must be determined properly.

정수장 응집혼화공정에서의 응집플럭 연속 모니터링 (On-line Monitoring of the Flocs in Mixing Zone using iPDA in the Drinking Water Treatment Plant)

  • 가길현;장현성;김영범;곽종운
    • 대한환경공학회지
    • /
    • 제31권4호
    • /
    • pp.263-271
    • /
    • 2009
  • 본 연구는 Y 정수장 혼화지의 응집효율을 향상시킬 목적으로 혼화지에서 생성되는 플럭을 실시간 온라인으로 평가하였다. 플럭크기를 평가하는 장비로는 온라인으로 플럭을 연속적으로 평가할 수 있는 응집플럭성장측정장치(iPDA)를 사용하였다. 플럭크기를 평가하기 위해 유기고분자 응집제인 폴리아민, 무기응집제 주입량, 원수의 탁도, pH같은 여러 가지 인자를 변수로 적용하였다. 현장실험 기간 동안 사용된 응집제는 폴리염화알루미늄(PACl)이었고, 응집보조재로 폴리아민이 사용되었다. 현장 테스트 기간 동안 원수의 탁도는 25~140 NTU 범위, pH는 7~9이었다. 원수의 탁도가 증가할수록 생성되는 플럭의 크기도 증가 하여 침전속도에 영향을 미쳤다. 회귀선분석으로 부터 FSI (Floc size index)와 탁도 T 값과의 관계식을 다음과 같이 얻었다. FSI = 0.9388logT - 0.3214 ($R^2$ = 0.8040, T : Turbidity) 또한 보조제로 사용된 폴리아민도 플럭크기값에 큰 영향을 주었고, 색도제거제로 사용된 활성탄(PAC)도 그 자체 입자로 작용하여 응집플럭크기 값에 영향을 상당히 주는 것으로 나타났다. 고탁도인 경우 FSI는 [PACl]과 [PAC]함수로 다음과 같은 식을 유도할 수 있었으며 $R^2$ = 0.9050이었다. FSI = $0.0407[T]^{0.324}[PACI]^{0.769}[PAC]^{0.178}$ [PACl] = PACl 주입농도, [PAC] = 활성탄 주입농도 상대적 응집속도 ${\Delta}FST/{\Delta}T$ 값은 응집제의 주입량보다는 활성탄의 주입량이 더 큰 영향을 주었다. 본 연구과정에서 활성탄주입량이 응집속도에 미치는 영향은 응집제의 주입농도가 미치는 것보다 ${\Delta}FST/{\Delta}T$ 값이 1.41 배 큰 것으로 나타났다. 본 연구에서 연구한 결과 플럭크기값 FSI는 여러 가지 영향인자에 상당한 영향을 받는 것으로 분석되었고, 집혼화 효율향상에 유익한 데이터를 얻을 수 있었다.

막 손상 측정을 위한 압력손실시험의 감도에 영향을 미치는 인자 (Influencing Factors on Sensitivity of Pressure Decay Test for Membrane Damage Assessment)

  • 이용수;김형수;김종오
    • 멤브레인
    • /
    • 제27권4호
    • /
    • pp.367-373
    • /
    • 2017
  • 중공사형 정밀여과(MF)와 한외여과(UF)를 포함한 가압식 막여과 시스템은 높은 수준의 병원균 제거 효율로 인해 음용수 처리에 점점 더 많이 사용되고 있다. 그러나 가압식 막여과 시스템에서 분리막의 손상으로 인한 막완결성의 문제가 발생시 병원체가 유출될 수 있으므로, 효과적인 온라인 또는 오프라인 방식의 막 완결성 모니터링 방법을 통해 수질의 안정성을 보장하여야 한다. 최근 막 완결성 시험 중 하나 인 압력손실시험(pressure decay test, PDT)이 가압식 분리막 모듈을 이용한 음용수 처리 시설에 적용되고 있다. 이 논문에서는 PDT의 기체 주입방법에 따른 세 가지 조건으로 원수 측, 여과수 측, 원수 여과수 양방향 측 세 가지 조건을 선정 후 이에 따른 감지감도를 이론값과 실험값을 적용하여 비교하였다. 실험결과 가압되는 측의 부피와 감도는 반비례함을 확인하였고, 주입부의 반대방향에 부압을 형성 시에도 감도가 증가함을 확인할 수 있다. 즉 막 손상의 감지감도는 주입되는 부분의 체적이 작아질수록, 분리막을 경계로 유입과 여과 측의 압력차가 클수록 높아짐을 알 수 있었다.