• Title/Summary/Keyword: on-line GC

Search Result 62, Processing Time 0.024 seconds

Determination of the mole fractions of ethylene oxide and freons in medical liquefied gas mixture by GC/AED (GC/AED를 이용한 의료용 액화혼합가스 중 산화에틸렌 및 프레온 가스류의 몰분율 측정)

  • Kim, Hyunjoo;Kim, Dalho;Lim, Arang;Lee, Taeck-Hong;Kim, Jin Seog
    • Analytical Science and Technology
    • /
    • v.25 no.6
    • /
    • pp.382-387
    • /
    • 2012
  • Ethylene oxide ($C_2H_4O$, EtO) is used as a raw material for the production of ethylene glycol and other industrially important material such as ethanolamines and also used as a disinfecting agent. It is applied for gas-phase sterilization of thermally sensitive medical equipment, and for processing of storage facilities as a mixture with fluorinated hydrocarbon. In this perspective, accurate determination of the mole fractions of components in the liquefied gas mixture is required for the quality control and safety of production and use. Each component of the liquefied gas mixture has different chemical and physical properties such as vapor pressure and boiling point. Therefore, we can suppose that analytical results can be different according to the introduction method for the gas phase of upper layer, or for the liquid phase of lower layer in gas cylinder. In this study, we designed a new on-line sample injection device for the liquefied gas mixture in liquid or gas state, and applied to the analysis of liquefied gas mixture of ethylene oxide and fluorinated hydrocarbons by GC/AED (gas chromatograph-atomic emission detector). We studied performance of AED, and effect of sample introduction and selected wavelength to the accuracy and repeatability of analytical results.

Comparative Study on Benefit Evaluation of Urban Rail Construction Project : Korea vs Japan (도시철도 건설사업의 편익계측에 관한 한일 비교연구)

  • 최창식;김경철;김용일
    • Proceedings of the KSR Conference
    • /
    • 1999.11a
    • /
    • pp.17-26
    • /
    • 1999
  • This paper studies on the benefit evaluation of urban railway construction project. We compares Korean Method with Japanese in calculating the generalized cost(GC) of a trip. In Japan, the disadvantage of transferring to another mode or line is included to calculate GC of trip. And environmental effects are contained directly as rail construction benefit. But in Korea, inconvenience of transferring facilities like stairways and passageway for riding a subway is not accounted to analyse benefit. As a result, there is a little investigate to improve and overcoming the inconvenience facilities of transfer, access, and egress. So, we suggest the containing the disadvantage measure of transferring facilities when subway riderships are forecasted. That will be reduced tile capital size of subway.

  • PDF

Simultaneous Determination of Pesticides in Water Using a GC/MS Coupled with Micro Extraction by Packed Sorbent (MEPS-GC/MS를 이용한 농약류 동시 수질분석)

  • Lee, Ki-chang;Lee, Wontae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.5
    • /
    • pp.262-268
    • /
    • 2015
  • This study established an analytical method to simultaneously determine six organophosphorous pesticides [methyldemetone-S, diazinon, fenitrothion, parathion, phentoate, and O-ethyl O-(4-nitrophenyl) phenylphosphonothioate (EPN)] and carbaryl in water using a gas chromatography/mass spectrometry (GC/MS) system coupled with on-line micro extraction by packed sorbent (MEPS) and programmed temperature vaporizer (PTV) injector. Polystyrene divinylbenzene (PDVB) was used as a sorbent of MEPS. The effects of elution solvents, pH, elution volume and draw-eject cycles of samples on sample pretreatment process were investigated. Also, quality assurance and quality control (QA/QC) and the recovery of the pesticides in environmental samples were evaluated. The elution was performed using $30{\mu}L$ of a mixed solvent (acetone : dichloromethane = 80 : 20 (v/v)). Sample pretreatment processes were optimized with seven cycles of draw-eject of sample (1 mL) spiking an internal standard and sulfuric acid. At lower pH, the analytical sensitivity of diazinon decreased, but that of carbaryl increased. The method detection limit and the limit of quantification for this method were 0.02~0.18 and $0.08{\sim}0.59{\mu}g/L$, respectively. The method precision and accuracy were 1.5~11.5% and 83.3~129.8%, respectively, at concentrations of $0.5{\sim}5.0{\mu}g/L$. The recovery rates for all the pesticides except carbaryl in various environmental samples ranged 75.7~129.3%. The recovery rate of carbaryl in effluent sample was over 200% whereas carbaryl in drinking water, groundwater, and river water were in the acceptable range.

Effect of p16 on glucocorticoid response in a B-cell lymphoblast cell line

  • Kim, Sun-Young;Lee, Kyung-Yil;Jeong, Dae-Chul;Kim, Hak-Ki
    • Clinical and Experimental Pediatrics
    • /
    • v.53 no.7
    • /
    • pp.753-758
    • /
    • 2010
  • Purpose: It has been suggested that p16 has a role in glucocorticoid (GC)-related apoptosis in leukemic cells, but the exact mechanisms have yet to be clarified. We evaluated the relationship between the GC response and p16 expression in a lymphoma cell line. Methods: We used p16 siRNA transfection to construct p16-inactivated cells by using the B-cell lymphoblast cell line NC-37. We compared glucocorticoid receptor (GR) expression, apoptosis, and cell viability between control (p16+NC-37) and p16 siRNA-transfected (p16-NC-37) cells after a single dose of dexamethasone (DX). Results: In both groups, there was a significant increase in cytoplasmic GR expression, which tended to be higher for p16+NC-37 cells than for p16- NC37 cells at all times, and the difference at 18 h was significant (P<0.05). Similar patterns of early apoptosis were observed in both groups, and late apoptosis occurred at higher levels at 18 h when the GR had already been downregulated ($P$<0.05). Cell viability decreased in both groups but the degree of reduction was more severe in p16+NC-37 cells after 18 h ($P$<0.05). Conclusion: These results suggest a relationship between GR expression and cell cycle inhibition, in which the absence of p16 leads to reduced cell sensitivity to DX.

Analysis of Binding Media in Dancheong Sample from Unhangak Hall of Hwaryeongjeon Shrine, Suwon (수원 화령전 운한각 단청시편의 교착제 분석)

  • Park, Jongseo;Lee, Sun Myung;Mun, Seong Woo;Kang, Yeong Seok
    • Journal of Conservation Science
    • /
    • v.37 no.3
    • /
    • pp.245-254
    • /
    • 2021
  • In this study, organic materials in Dancheong specimens were analyzed to establish a Dancheong preparation method in Unhangak Hall of Hwaryeongjeon Shrine, Suwon. IR and pyrolysis/GC/MS were applied to a Zuhong specimen and a gilded one. The IR spectra showed absorption peaks corresponding to C-O, C=O, OH, although they were different from those of animal glue, Asian lacquer, and drying oil. The Pyrolysis/GC/MS after the on-line methylation revealed Asian lacquer-derived components, such as methyl 7-(2,3-dimethoxyphenyl)heptanoate, and drying oil-derived components, such as nonanedioic acid, dimethyl ester. Based on these results, we estimated that Asian lacquer and drying oil were used in the Dancheong preparation. Small amounts of 3-methyl-1H-pyrrole were also detected, which could possibly originate from animal glue. The radiocarbon age of the specimens appeared to be between the late 17th to the early 20th century. This study potentially reports the first case of Asian lacquer detection in a Dancheong specimen in Korea.

Multi Analysis of Fumigants in Soil and Water (물과 토양에서 훈증제의 동시분석법 확립)

  • Kim, Jung-Ho
    • Environmental Analysis Health and Toxicology
    • /
    • v.21 no.4 s.55
    • /
    • pp.365-373
    • /
    • 2006
  • Emission of methyl bromide (MeBr) from soil was implicated in stratospheric ozone depletion. To determine multi analysis of alternatives fumigants for MeBr, this paper describes the methods of analysis in water and soil. The MeBr, methyl iodide (Mel), propargyl bromide (PBr), cis 1,3-dichloropropene (cis 1,3-D), trans 1,3-dichloropropene (trans 1,3-D) and chloropicrin(CP) are separated on the base line on GC-ECD at three column of AT+DB+DB (90m) with temperature programing of $35^{\circ}C{\rightarrow}110^{\circ}C$ on GC-ECD. The relative retention time for MeBr, Mel, PBr, cis 1,3-D, trans 1,3-D and CP is 1.0, 1.4, 2.3, 3.2, 3.6 and 3.7, respertively. The detection limit for MeBr, Mel, PBr, cis 1,3-D, trans 1,3-D and CP is 469 pg, 5 pg, 21 pg, 79 pg, 101 PE and 5pg, respectively. Recovery of MeBr Mel, PBr, cis 1,3-D, trans 1,3-D and CP in water added 150 ppm fumigants were 81%, 96%, 95%, 97%, 98% and 99%, respectively. Recovery of MeBr, MeI, PBr, cis 1, 3-D, trans 1,3-D and CP in soil added 150ppm fumigants were 56%, 84%), 85%, 81%, 87% and 88%, respectively.

Studies of gas chromatographic analysis of malodorous S compounds in air (대기 중 악취황 성분들에 대한 GC 분석의 특성)

  • Kim, Ki-Hyun;Oh, Sang In;Choi, Y.J.
    • Analytical Science and Technology
    • /
    • v.17 no.2
    • /
    • pp.145-152
    • /
    • 2004
  • In this study, analytical characteristics of S gas detection technique were investigated against four major reduced S compounds (including hydrogen sulfide; methyl mercaptan; dimethyl sulfide (DMS); and dimethyl disulfide (DMDS)). To analyze such properties, an analytical system was constructed by combining the GC/PFPD system with the loop injection method. The results of our analysis indicated that response behavior of S gases differs greatly between compounds; H2S exhibited the weakest sensitivity of all compounds, while DMDS with two S-atom compounds the strongest sensitivity. To learn more about their response behavior on GC/PFPD method, their calibration patterns were compared using the three arbitrarily set concentration ranges of low, intermediate, and high. The results showed that calibration patterns of each compound are distinguished because of different factors. There was a line of evidence that calibration of $H_2S$ was affected noticeably by adsorptive loss within the system, whereas those of DMS and DMDS were influenced most sensitively by such factor as the linearity response at a given PMT voltage setting. The overall results of our study suggest that quantification of malordorous S compounds require a better knowledge of compound-specific response behavior against GC detection.

Continuous Measurements of Reduced Sulfur Gases in Urban Air (연속측정방법을 이용한 도심권 대기질 내 저농도 황화합물의 관측에 대한 연구)

  • Choi Ye-Jin;Kim Ki-Hyun;Oh Sang-In;Shon Zang-Ho
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.2
    • /
    • pp.195-204
    • /
    • 2004
  • In this study, the concentrations of major reduced sulfur compounds (H$_2$S, $CH_3$SH, DMS, and DMDS) were determined from ambient air in a monitoring station located in the mid-eastern area of Seoul. Measurements of sulfur species were conducted by the combination of on -line air sampling, thermal desorption, and capillary GC/PFPD analysis. A total number of 143 hourly samples were collected in the two time periods set between June and July 2003. The mean concentrations of four sulfur species measured in the whole study period were found on the order: DMS (535$\pm$183) > H$_2$S (47$\pm$10) > DMDS (35$\pm$22) > $CH_3$SH (6.19$\pm$29.4 pptv). The results of this study show that the concentrations of DMS at the study area are generally higher than those reported previously in the oceanic environments, while those of other sulfur species are not easy to compare with due to the lack of data. The H$_2$S concentrations were generally higher during the daytime than the nighttime, whereas those of others generally exhibited a reversed diurnal pattern. The overall results of our study suggest that the distribution of major reduced S compounds should be controlled by diverse processes in the urban area.

Studies on the Simultaneous Determination of VNA and TSNA by GC - TEA (Gas chromatography-Thermal Energy Analyzer에 의한 휘발성 니트로소아민과 담배 특유의 니트로소아민들의 동시 분석연구)

  • Rhee, Mun-Su;Ji, Sang-Woon;Park, Yang-Su
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.15 no.2
    • /
    • pp.174-184
    • /
    • 1993
  • This is to investigate the methodology for the simultaneous determination of Wk, mk and TSNA using gas chromatography(GC) in combination with chemiluminescence detector, thermal energy analyzer(TEA) . The simultaneous analysis has been estimated by evaluating tobacco. The TEA was linked to GC equipped with non -polar SPB -5 fused silica capillary column which was introduced into the ceramic pyrolysis tube by the point of 16cm from the end of TEA. Quantification was carried out by internal standardization with WDPA after calibration of retention times and response factors with authentic nitrosoamines. It was demonstrated that WDPA was most preferable as internal standard for the simultaneous analysis. The recoveries of the internal standard were in the range of 83∼96% . Nitrosoamines in this method were detected with determination limit of 0.1ng and was made by a straight line in calibration curve by TEA response. The suitability of nitrosoamines extraction in tobacco leaf was investigated. It was most suitable to extract nitrosoamines from tobacco leaves with 0.01 M NaOH within a period of 8 hours. Thimerosal as an antibacterial agent was added to NaOH solution to prevent artifactual formation. The fractionation and the purification of nitrosoamines form alkaline extracts were conveniently performed using Extrelut multilayer column and dichloromethane. Reproducible and reliable results were obtained for the determination of nitrosamines in a relatively short time compared to previous known method. TSNA contents in burley were about 4 times higher as those in the fluecured tobacco.

  • PDF

Development of Portable Preconcentration-Gas Chromatography System for Fast Analysis of Trace Benzene, Toluene and Xylene in Air (대기 중 극미량의 벤젠, 톨루엔 및 자일렌의 신속한 분석을 위한 휴대용 농축-기체 크로마토크래피 시스템 개발)

  • Jung, Young-Rim;Kim, Man-Goo
    • Analytical Science and Technology
    • /
    • v.14 no.5
    • /
    • pp.432-441
    • /
    • 2001
  • An automated on-line portable preconcentration-short column gas chromatograph was developed, which used preconcentrator using adsorption tube with Tenax-GR and Curie-point heating. The developed system operated with 3 steps of processing, preconcentration, thermal desorption, and analysis and cleaning, and could continued operating within 1~2 min cycle. The recoveries of preconcentrator for toluene was ranged between $94.7{\pm}6.6%$ and $103.8{\pm}3.1%$ with less than 7% of RSD. For benzene, toluene and xylene(BTX) standard gas test, IDL was 41, 49, $472ng/m^3$ benzene, toluene and o-xylene, respectively. The BTX mixture was analyzed within 30 sec with baseline separation by the system equipped with 4 m long capillary column. The deficiency of separation power caused by short column was solved by the control of sample injection volume and inlet/outlet pressure ratio. The automated portable preconcentration-short column gas chromatograph system was found to be useful for the continuous air monitoring of BTX at ppb levels in ambient air.

  • PDF