• Title/Summary/Keyword: on-body patch

Search Result 94, Processing Time 0.022 seconds

A Study on Antenna Characteristics for Efficiently Detecting Human Sign (효율적인 인체신호 검출을 위한 안테나 특성 연구)

  • Jang, Dong-Won;Choi, Jae-Ik
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.10a
    • /
    • pp.484-487
    • /
    • 2014
  • In this paper, We describe antenna characteristics for efficiently detecting human signs using small, planar and low power antenna. Then we can measure biological signals including respiration, heart rate, blood pressure, and blood sugar, using UWB (Ultra Wide Band) pulses, while does not contact the human body. The antenna need stable and wideband impedance characteristic, because it use gaussian pulse signal. Usually it has trade-off between wideband impedance and gain. But we don't considered array type antennas because we want to need small size. Generally the antennas that classified as frequency independent satisfy our requirements. Frequency independent antennas include spiral, log-periodic, sinuous, and etc. These antennas are possible to have shape planar type. In this paper, We tested these kind antenna's characteristics in center frequency 5 GHz, Especially circular patch and sinuous antenna designed and analyzed.

  • PDF

Development of Small Manipulator Platform for Composite Structure Repair (복합재 구조물 유지보수를 위한 소형 매니퓰레이터 플랫폼 개발)

  • Geun-Su Song;Hyo-Hun An;Kwang-Bok Shin
    • Composites Research
    • /
    • v.36 no.2
    • /
    • pp.108-116
    • /
    • 2023
  • In this paper, kinematic design and multi-body dynamics analysis were conducted to develop a small manipulator platform for automating the maintenance of structures made of composite materials. To design manipulator kinematically, the existing composite repair process was considered. The 3D design was conducted after selecting the basic specifications of manipulator and end-effecter in consideration of the patch lamination process for repair. Then, variables necessary for simulation and control were generated in MATLAB through inverse kinematic analysis. To evaluate the structural stability of platform, multibody dynamics analysis was conducted using Altair Inspire and Optistruct. Based on the simulation conducted in Inspire, multibody dynamics analysis was conducted in Optistruct, and structural stability was verified through the results of maximum displacement and Von-Mises stress over time. To verify the design, manufacturing and controlling of platform were conducted and compared with the simulation. It was confirmed that the actual repair process path and the simulation showed a good agreement.

Arterial Switch Operation for Transposition of G rest Arteries (대혈관전위증에 대한 동맥전환술)

  • 이호철;류한영
    • Journal of Chest Surgery
    • /
    • v.29 no.3
    • /
    • pp.278-284
    • /
    • 1996
  • Nine infants with transposition of great arteries have undergone arterial switch operation from May 1989 to May 1994 in the Department of Thoracic and Cardiovascular Surgery, Yeungnam University Hospital. Patients' age ranged from 3 days to 90 days, averaging 30$\pm$21 days. Diagnosis was made by two-dimensional echocardiography in all patients. Eight patients were diagnosed as transposition of great arteries with ventricular septal defect and one patient was a simple transposition of great arteries. Associated anomalies were patent ductus arteriosus (8), atrial septal defect (7) and coarctation of aorta(1). The anatomy of the coronary arteries were 7 (77 %) type A and 2 (23 %) type D according to the Yacoub classification. Pulmonary artery reconstruction was done according to Lecompte maneuver with tautologous pericardial patch in 8 patients. Overall operative mortality rate was 55% Left heart failure and pulmonary hypertensive crisis were the cause of death on postoperative 1~2 days in three patients, and two succumbed to death due to sepsis on postoperative 2~ 3 weeks. The mean follow-up period was mean 17 months. No patient had clinically significant postoperative aortic regurgitation and supravalvular pulmonary stenosis. The excessive use of inotropic support postoperatively was identified as a stastically significant risk factor following the arterial switch operation. But other variables such as low body weight, long cardiopulmonary bypass time, excessive hemodilution during cardiopulmonary bypass, hypothermia and volume loading were not significant risk factors.

  • PDF

An Atlas Generation Method with Tiny Blocks Removal for Efficient 3DoF+ Video Coding (효율적인 3DoF+ 비디오 부호화를 위한 작은 블록 제거를 통한 아틀라스 생성 기법)

  • Lim, Sung-Gyun;Kim, Hyun-Ho;Kim, Jae-Gon
    • Journal of Broadcast Engineering
    • /
    • v.25 no.5
    • /
    • pp.665-671
    • /
    • 2020
  • MPEG-I is actively working on standardization on the coding of immersive video which provides up to 6 degree of freedom (6DoF) in terms of viewpoint. 3DoF+ video, which provides motion parallax to omnidirectional view of 360 video, renders a view at any desired viewpoint using multiple view videos acquisitioned in a limited 3D space covered with upper body motion at a fixed position. The MPEG-I visual group is developing a test model called TMIV (Test Model for Immersive Video) in the process of development of the standard for 3DoF+ video coding. In the TMIV, the redundancy between a set of input view videos is removed, and several atlases are generated by packing patches including the remaining texture and depth regions into frames as compact as possible, and coded. This paper presents an atlas generation method that removes small-sized blocks in the atlas for more efficient 3DoF+ video coding. The proposed method shows a performance improvement of BD-rate bit savings of 0.7% and 1.4%, respectively, in natural and graphic sequences compared to TMIV.

Studies on the Development of Blood Sausage from By-products -Appreciation of Blood Sausage Qualities from the Animal Experiments- (부산물(副産物)을 이용(利用)한 혈액(血液)소시지 개발(開發)에 관한 연구(硏究) -동물실험(動物實驗)을 통한 제품가치(製品價値) 평가(評價)-)

  • Koh, Jin-Bog;Moon, Yoon-Hee;Kim, Jae-Young;Moon, Yeong-Duck
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.13 no.3
    • /
    • pp.319-325
    • /
    • 1984
  • This experiment aims to observe the nutritive value of blood sausages by manufacturing three kinds of them in order to utilize various by-products of swine when it is processed. In attempt to do so, five different diets were made: one control diet and four diets in which three kinds of blood sausages(blood sausage-1 was made with sausage meat 10%, fat 40%, blood 20%, skin 20% and liver 2%. blood sausage-2 was made with ham meat 30%, fat 20%, blood 20%, liver 2% and skin 20%. blood sausage-3 was made with smoked ham patch 30%, fat 20%, blood 20%, liver 2% and skin 20%) and mixed sausage(sausage meat 20%, fat 10% and fish meat 35%) were mixed with control diet at the rates of 10% respectively. These diets were fed to growing male and female albino rats for 6 weeks. The results obtained through this study are summarized as follows. In body weight gain of male rats, blood sausage-1 and 2 groups were significantly higher than mixed sausage group during the experimental period, and in that of female rats, control group and blood sausage-1 group were similar, but the other groups were lower than control group. Food intake was different in each group every week, but the amount of that was similar to each one throughout all experimental period. Food efficiency ratio and protein efficiency ratio in male were similar in each group, but slightly different in female during the feeding period. Liver weights of male in mixed sausage group and blood sausage-3 group were lower than those in control group and blood sausage-2 group, but liver weight of female in blood sausage-2 group was lower than that in control group. And all groups were similar in liver weight per 100 g of body weight. Mixed sausage group and blood sausage-1 group were lower than control group in kidney weight of male, and blood sausage-1 group was lower than control group in kidney weight of female. Kidney weight per 100 g of body weight of male showed that blood sausage-1 group was lower than the other groups. Spleen weight was similar in all groups. Hematocrit and hemoglobin contents in blood, total protein, albumin, albumin/globulin ratio, total lipid and total cholesterol contents in serum were showed almost similar in all groups.

  • PDF

Development of an Eye Patch-Type Biosignal Measuring Device to Measure Sleep Quality (수면의 질을 측정하기 위한 안대형 생체신호 측정기기 개발)

  • Changsun Ahn;Jaekwan Lim;Bongsu Jung;Youngjoo Kim
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.12 no.5
    • /
    • pp.171-180
    • /
    • 2023
  • The three major sleep disorders in Korea are snoring, sleep apnea, and insomnia. Lack of sleep is the root of all diseases. Some of the most serious potential problems associated with sleep deprivation are cardiovascular problems, cognitive impairment, obesity, diabetes, colitis, prostate cancer, etc. To solve these problems, the Korean government provided low-cost national health insurance benefits for polysomnography tests in July 2018. However, insomnia patients still have problems getting treated in terms of time, space, and economic perspectives. Therefore, it would be better for insomnia patients to be allowed to test at home. The measuring device can measure six biosignals (eye movement, tossing and turning, body temperature, oxygen saturation, heart rate, and audio). A gyroscope sensor (MPU9250, InvenSense, USA) was used for eye movement, tossing, and turning. The input range of the sensor was in 258°/sec to 460°/sec, and the data range was in the input range. Body temperature, oxygen saturation range, and heart rate were measured by a sensor (MAX30102, Analog Devices, USA). The body temperature was measured in 30 ℃ to 45 ℃, and the oxygen saturation range was 0% for the unused state and 20 % to 90 % for the used state. The heart rate measurement range was in 40 bpm to 180 bpm. The measurement of audio signal was performed by an audio sensor (AMM2742-T-R, PUIaudio, USA). The was -42 dB ±1 dB frequency range was 20 Hz to 20 kHz. The measured data was successfully received in wireless network conditions. The system configuration was consisted of a PC and a mobile app for bio-signal measurement and data collection. The measured data was collected by mobile phones and desktops. The data collected can be used as preliminary data to determine the stage of sleep and perform the screening function for sleep induction and sleep disturbances. In the future, this convenient sleep measurement device could be beneficial for treating insomnia.

Open Heart Surgery for Six Cases of the Conegnital Heart Disease (선천성(先天性) 심장병(心臟病)의 개심술(開心術) -6례(例) 수술경험(手術經驗) -)

  • Lee, Sung Haing;Lee, Sung Koo;Han, Sung Sae;Lee, Kihl Rho;Kim, Song Myung;Lee, Kwang Sook;Lee, Chong Kook
    • Journal of Chest Surgery
    • /
    • v.9 no.2
    • /
    • pp.220-238
    • /
    • 1976
  • Six cases of congenital heart disease were operated on by means of cardiopulmonary bypass between December, 1975 and April, 1976. Two cases of ventricular septal defects (VSD), two cases of VSD, associated with ruptured aneurysm of sinus Valsalva, two cases of atrial septal defects (ASD) and one case of pulmonic stenosis with patent ductus arteriosus were operated. Sarns roller pumps and Bentley Temptrol oxygenators were used for extracorporeal circulation. Pump oxygenator was primed with Ringer's lactate solution, 5% dextrose in water, mannitol, and ACD blood. Flow rate ranged from 2.0 to $2.4L/M^2/min$. Bicarbonate was added to the oxygenator with estimated amount as 15 mEq/L/hr. Venous catheters were introduced into superior and inferior vena cava, and oxygenated blood was returned to the body through aortic cannula inserted into ascending aorta. Moderate hypothermia ($30^{\circ}C$) was induced by core cooling. Aorta was cross clamped for 15 minutes and released for 3 minutes, and repeated clamping when necessary. Atrial and ventricular septal efects were closed by direct sutures. Aneurysms of sinus Valsalva ruptured into the right ventricle were repaired through right ventriculotomy by d:rect closure with Dacron patch reinforcement. Cardiopulmonary bypass time varied from 66 to 209 minutes, and aorta cross clamping time ranged from 13 to 56 minutes. Postoperative bleeding was minimal except one case who needed for evacuation of substernal hematoma. Intra- and postoperative urinary output was satisfactory. Acid-base balance, partial pressure of $O_2$, electrolytes, and hematological changes during intra- and post-perfusion period remained at the acceptable ranges. No mortality was experienced.

  • PDF

Stress Intensity Factor of Cracked Plates with Bonded Composite Patch by p-Convergence Based Laminated Plate Theory (p-수렴 적층 평판이론에 의한 균열판의 팻취보강후 응력확대계수 산정)

  • Woo, Kwang-Sung;Han, Sang-Hyun;Yang, Seung-Ho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.5A
    • /
    • pp.649-656
    • /
    • 2008
  • The enhancement of the service life of damaged or cracked structures is a major issue for researchers and engineers. The hierarchic void element based on the integrals of Legendre polynomials is used to characterize the fracture behaviour of unpatched crack as well as repaired crack with bonded composite patches by computing the stress intensity factors and stress contours at the crack tip. Since the equivalent single layer approach is adopted in this study, the proposed element is necessary to represent a discontinuous crack part as a continuum body with zero stiffness. Thus the aspect ratio of this element to represent the crack should be extremely slender. The sensitivity of numerical solution with respect to energy release rate, displacement and stress has been tested to show the robustness of zero stiffness element as the aspect ratio is increased up to 2000. The stiffness derivative method and displacement extrapolation method have been applied to calculate the stress intensity factors of Mode I problem. It is noted that the proposed hierarchical void element can be one of alternatives to analyze the patched crack problems.

Nickel dust-induced occupational contact dermatitis by welding and grinding work in shipyard workers: a report of nine cases

  • Daehwan Kim;A Ram Kim;Hanjun Kim;Sunghee Lee;Byeonghak Seo;Ho Seok Suh;Chang Sun Sim;Heun Lee;Cheolin Yoo
    • Annals of Occupational and Environmental Medicine
    • /
    • v.34
    • /
    • pp.7.1-7.10
    • /
    • 2022
  • Background: Occupational skin diseases are skin conditions that occur or worsen in relation to work and known to be the second most common type of occupational disease affecting individuals in the United States. In Korea, epidemiological reports related to occupational skin diseases are rare. But, no cases of occupational contact dermatitis caused by welding and grinding work have been reported previously. Case presentation: Nine male workers working in the production department for liquefied natural gas (LNG) ships in Ulsan complained of erythematous papules/patches and itching in various areas of the body after welding and grinding work. The work environment monitoring report revealed that the amount of nickel dust exceeded the time weighted average (TWA) and poor local ventilation status. Based on the symptoms and the overall results of surveys, several tests, and work environment monitoring report, the 2 workers who had positive patch-test reactions to nickel were diagnosed with nickel dust-induced allergic contact dermatitis. The other 7 workers were diagnosed that there was a high probability that they had nickel dust-induced irritant contact dermatitis. The 2 workers who had nickel dust-induced allergic contact dermatitis were recommended to switch their jobs. Conclusions: Nickel is one of the most common cause of allergic contact dermatitis. In this case, the dust was assumed to be created by welding work with a high nickel content new welding rod and subsequent grinding work, and the concentration of this dust exceeded the time weighted average. Thus, it is thought that the nickel dust may have caused contact dermatitis through continuous contact with the workers' exposed skin in a poorly ventilated space. Currently, several domestic shipbuilding companies are manufacturing LNG tankers using a new construction method. Consequently, it is highly likely that similar cases will occur in the future, which makes this case report meaningful.

Analysis on the Spatial Characteristics Caused by the Cropland Increase Using Multitemporal Landsat Images in Lower Reach of Duman River, Northeast Korea (다시기 위성영상을 이용한 두만강 하류지역의 농경지 개간의 공간적 특성분석)

  • Lee, Min-Boo;Han, Uk;Kim, Nam-Shin;Han, Ju-Youn;Shin, Keun-Ha;Kang, Chul-Sung
    • Journal of the Korean Geographical Society
    • /
    • v.38 no.4
    • /
    • pp.630-639
    • /
    • 2003
  • This study aims to analysis the distribution and change of cropland and forest, the Onseong, Saebyeol, and Eundeok counties on the lower reach of Duman(Tumen) river, northeast Korea, using 1992 year Landsat TM data, 2000 year Landsat ETM data, and digital terrain elevation data(DTED). Land cover and land use of the study areas are classified into cropland, forest, village, and water body, using the supervised classification method including 1:50,000 DTED analysis, image band composition, and principal component analysis(PCA). Results of quantitative analysis present that each growth rate of cropland of Onseong and Eundeok are 22.8% and 14.7% corresponding to decreasing rates of forest, 8% and 13.6% during 8 years from 1992 to 2000. In Onseong, Saebyeol, and Eundeok, each values of mean elevations and slope gradients increased to 192m, 95m, and 91m from 157m, 85m, and 78m, and to 6.6$^{\circ}$, 3.0$^{\circ}$, and 4.4$^{\circ}$ from 5.2$^{\circ}$, 2.5$^{\circ}$, and 3.0$^{\circ}$. Especially, in case of newly developed cropland, the values of mean elevation and mean gradient have 225m, 122m, and 127m, and 9.4$^{\circ}$, 5.1$^{\circ}$, and 8.0$^{\circ}$, in above three regions. These new croplands were developing along to deeper valleys and toward lower hill and mountain slope up to knickpoint zone of gradient change. Deforested lands for cropland have formed irregular pattern of patch-type, and become sources for the sheet erosion, rilling and gulleying in mountain slope and sedimentation in local river channel. Though there were no field checking, analysis using landsat images and GIS mapping can help understand actual environmental problems relating to cropland development of mountain slope in North Korea.