• Title/Summary/Keyword: omission test

Search Result 94, Processing Time 0.031 seconds

Chinese KFL learners' production aspects of post-lexical phonological process in Korean - Focusing on the nasalization - (운율구 형성과정에서 나타나는 어휘부와 후어휘부 필수음운현상에 대한 중국인학습자들의 발화양상 -비음화를 중심으로-)

  • Yune, Youngsook
    • Phonetics and Speech Sciences
    • /
    • v.8 no.1
    • /
    • pp.53-62
    • /
    • 2016
  • In this study, we examined whether Chinese learners of Korean can correctly produce the phonological process on the lexical and post-lexical level. For this purpose 4 Korean native speakers and 10 advanced and 10 intermediate Chinese learners of Korean participated in the production test. The materials analyzed constituted 10 Korean sentences in which nasalization can be applied on the syllable boundary, word boundary(w-boundary) as well as accentual phrase boundary(AP-boundary). The results show that for Korean speakers, nasalization was applied 100% at all level whereas for Chinese speakers, the rate of application of nasalization is different according to prosodic constituents and Korean proficiency. Nasalization was more frequently applied at the lexical level than the post-lexical level, and it is more frequent in the w-boundary conditions than in the AP-boundary conditions. However, the rate of nasalization in the w-boundary is close to the lexical level. The pronunciation errors were committed either as non application of nasalization or coda obstruent ommission. In the case of non application of nasalization, Chinese learners of Korean produced the target syllables as underling forms, which were not transformed as surface forms. In addition, we can observe the ommission of coda obstruents in 'lenis obstruents+nasal sound' sequences. As a result, nasalization is blocked by this omission.

Effect of Cooling Velocity on the Microstructures and Mechanical Properties of Si, Mn, V added HSLA Steels (Si, Mn, V이 첨가된 비조질강의 미세조직 및 기계적 성질에 미치는 냉각속도의 영향)

  • Park, Yon-Seo;Choi, Chang-Soo;Chung, In-Sang
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.14 no.5
    • /
    • pp.267-274
    • /
    • 2001
  • Microalloyed steels, which substituted by conventional quenched and tempered steels, have been used in a wide variety of structural and engineering application. The main driving force for preference of MA steels is a cost reduction which can be achieved by an omission of heat treatment. In this study, low carbon martensitic MA steels in 0.18C-0.30(0.60)Si-2.00(1.80)Mn-0.05S-1.5Cr-0.05(0.10)V-0.015Ti(wt%) were investigated to know the effects of cooling method on the mechanical properties and microstructures of Si, Mn, V added microalloyed steel at different reheating temperature. Microstructure of oil quenched steels which were comprised lath martensite, auto-tempered martensite and retained austenite, had more various structure than that of air cooled steel made of mainly bainite. Therefore, oil quenched steels, which had more various microstructure, had better strength-toughness balance compare to air cooled steels. In the impact test, fracture mode of oil quenched steels, which showed good mechanical properties, were dimple, but that of air cooled steels were cleavage.

  • PDF

A Study on the Indoor Air Pollutants Emission Characteristics by Composed Building Materials (건축자재 마감구성에 따른 실내공기오염물질 방출특성에 관한 연구)

  • Park, Jin-Chul;Rhee, Eon-Ku;Yu, Hyung-Ku
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.3-8
    • /
    • 2005
  • Building parts of Multi-Family Houses are consisted of several building material assembly. Therefore, after selecting building materials with test result of emission intensity and their feature, composed building materials are made equally with actual construction methods, and experimented emission intensity. 7 days after experiment, formaldehyde emission intensity appeared low in an order of Tile Wall, Wood Flooring, Wallpaper, Reum Flooring, Silk Wallpaper, and 20 days after experiment, TVOC emission intensity appeared low in an order of Tile Wall, Reum Flooring, Silk Wallpaper, Wood Flooring, Wallpaper. There was a clear difference in TVOC emission intensity according to kind of building materials. Composed building materials that weight per unit area is big and omission intensity is high, they effect continuously to indoor air because decrement is small.

  • PDF

Reform of sacrificial ritual model through the empirical tests of reformative model far Korean sacrificial rite (제례 재구성 모델의 실증적 검증을 통한 제례 모델 재구성)

  • 두경자
    • Journal of Families and Better Life
    • /
    • v.19 no.6
    • /
    • pp.241-263
    • /
    • 2001
  • The objectives of this study were empirically to test the reformative model for Korean sacrificial rite and to investigate the effects of demographic variables. the survey was conducted by means of questionnaire with 600 persons located in Seoul. Major findings were as follows ; 1, Sacrificial day ; was displayed (1) dead day (2) holiday in back and forth of dead day 2. Sacrificial time ; was showed (1) 8-9 h. p.m (2) 6-7 h. p.m 3. Sacrificial extent ; was displayed (1) grandparents and parents (2) only parents 4. Participative extent ; was showed (1) Cousin (2) only sons and daughters 5. Sacrificial procedure ; was displayed twice deep bow and 1 minute\`s silent prayer. 6. New year's and Chusok's rite ; was showed (1) simple foods (2) joint leisure time 7. Sacrificial table ; was displayed (1) boiled rice . water . gustoish articles. (2) omission of food table 8. rite\`s socialization ; was showed (1) delivery and marketing sale\`s food (2) special sacrificial restaurant. 9. Womens'and mens'difference ; women were active 7ut men were passive 10. Age's difference ; excepting 30-40, the all generations were more reformative. 11. Number of brothers ; small number of brothers were more reformative than a many number. 12. Sacrificial manager or not , managers were conservative than persons were not managers.

  • PDF

A Study on Biological Wastewater Treatment using the Combination of Anaerobic and Two Intermittent Aeration Tanks Operated Alternately: A Pilot-scale Study (혐기 및 2단 교호(交互) 간헐포기조를 이용한 하수고도처리에 관한 연구: 파일럿 규모의 실험결과를 중심으로)

  • Choi, Yong-Su;Hong, Seok-Won;Kwon, Gihan
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.3
    • /
    • pp.269-274
    • /
    • 2004
  • The performance of a newly designed wastewater treatment process equipped with an anaerobic and two intermittent aeration tanks operated alternately was investigated. During the experimental period, several types of cyclic operating schedules with different aeration and non aeration time were examined for the optimization. At all modes, the removals of organic matter and SS were highly achieved. With respect to T-N removal, however, the cycle length for aeration on/off affected the efficiencies. At the optimal operating mode, the ORP bending point indicating the disappearance of nitrate was observed. Considering the influent wastewater characteristics and cyclic operating schedules, it can be suggested that T-P removal is much more BOD/T-P ratio and/or its load dependant rather than the aeration on/off time. The results obtained from pilot-scale test showed the competitive advantage of this alternating process through an omission of nitrate recycle and operational flexibility against influent load variations when comparing with other continuous flow processes.

The Relationship between Hair Zinc and Lead Levels and Clinical Features of Attention-Deficit Hyperactivity Disorder

  • Shin, Dong-Won;Kim, Eun-Ji;Oh, Kang-Seob;Shin, Young-Chul;Lim, Se-Won
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.25 no.1
    • /
    • pp.28-36
    • /
    • 2014
  • Objectives : The goal of this study was to examine the association between zinc and lead level and symptoms of attention-deficit hyperactivity disorder (ADHD) among Korean children. Methods : A total of 89 clinic-referred children participated in the study (ADHD group=45, control group=44). The participants were 5-15 years old, and were mainly from urban areas of Seoul, Korea. ADHD was diagnosed using the Kiddie-Schedule for Affective Disorders and Schizophrenia-Present and Lifetime Version. We excluded children with a comorbid psychiatric disorder, medical illness requiring medication, or a prior history of taking ADHD medication. In order to evaluate the severity of ADHD symptoms, parents' Korean ADHD Rating Scale (K-ARS) was used. The ADHD diagnostic system (ADS) was used for evaluation of the severity of inattention and impulsivity. All participants completed the intelligence test and hair mineral analysis. Multiple regression analysis was used to examine the effect of hair zinc and lead levels on the K-ARS and ADS. We measured the predictive ability of the zinc and lead levels using logistic regression analysis. Results : The lead level explained the score for omission errors, commission errors, and response time SD in visual ADS in the ADHD group (adjusted $R^2$=.243, p<.01, adjusted $R^2$=.362, p<.01, and adjusted $R^2$=.275, p<.01), the score for omission errors of auditory ADS in ADHD group (adjusted $R^2$=.407, p<.01) and the entire group (adjusted $R^2$=.292, p<.01). Zinc was significantly explanatory for the K-ARS scores for the entire group (adjusted $R^2$=.248, p<.001) and the ADHD group (adjusted $R^2$=.247, p<.05). Conclusion : These findings suggest a possible role of zinc and lead in ADHD. Lead concentration in hair samples affected the ADS scores, and this was more prominent in children with ADHD. Children with ADHD had a lower zinc concentration in their hair, and the zinc concentration in hair showed negative correlation with the K-ARS score.

Processing Conditions of Dried Shellfish Condiments (패류를 이용한 분말조미료 가공조건)

  • BAE Tae-Jin;CHOI Ok-Soo;KANG Hoon-I
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.32 no.2
    • /
    • pp.175-179
    • /
    • 1999
  • Processing conditions for dried condiments with oyster, pen shell and cockle shell were investigated. The enzymatic hydrolysis for 3 hours was more profitable than hydrothermal extraction to develop flavoring matters from oyster, pen shell and cockle shell. As a result of omission tests, nucleotides were predominated in the taste compounds of shellfish hydrolysates rather than free amino acids, and the contribution of nucleotides and free amino acids to the taste of shellfish hydrolysates was remarkable. The major flavoring components of shellfish hydrolysates were free amino acids and oligopeptides below 500 dalton. When shellfish hydrolysates were separated with membrane (molecular weight cutoff 500 dalton) for recovering flayer, recovering yields of amino type nitrogen were $92.1\~92.8\%$. Moisture contents of dried shellfish condiments prepared with pretense hydrolyzed oyster, pen shell and cockle shell were $3.5\%,\;3.8\%$ and $3.7\%$, respectively. Contents of total nitrogen were $69.4\%,\;78.8\%$ and $74.2\%$, and those of amino nitrogen were $45.5\%,\;48.9\%$ and $45.4\%$, respectively. Drying yield, solubility and absorption rates at Aw 0.88 were $11.7\%,\;78.4\%$ and $6.8\%$ in oyster, $8.2\%,\;73.6\%$ and $6.1\%$ in pen shell, $9.8\%,\;76.9\%$ and $6.6\%$ in cockle shell, respectively.

  • PDF

A Study on the application of planning national index numbers in the Cadastral triangulation point (지적삼각(보조)점의 국가지점번호 활용방안에 관한 연구)

  • Lee, Hyong-Sam;Shin, Soon-Ho;Sung, Yeon-Dong
    • Journal of Cadastre & Land InformatiX
    • /
    • v.45 no.2
    • /
    • pp.45-56
    • /
    • 2015
  • The main purpose of this investigation is to make up for the limitations of parcel addressing and to seek the application plan of cadastral triangulation point to effective installation of national index numbers. The test-bed has been constructed at the mountainous area located in Nowon-gu, seven cadastral triangulation points within the test-bed was directly applied to this investigation. Each points have been firstly converted from a plane rectangular coordinates to a single plane rectangular coordinates (UTM-K). To verify positioning results achieved from these points, a single plane rectangular coordinates through the Network-RTK was considered. With regards to verification result, maximum coordinate shift was revealed by 6 cm, this level of difference can be satisfied to Article 7, paragraph 2 "the regulation for National Index Number". This means that coordinate transformation applied with cadastral triangulation points can achieve the sastisfied result without local surveying. And also, remarkable effects have been created in terms of financial effectiveness and safe preservation of cadastral triangulation points due to the omission of local surveying.

Usefulness of Clinical T-Score of Continuous Performance Test for Differential Diagnosis : among Attention-Deficit Hyperactivity Disorder, Depressive Disorder, Anxiety Disorder, and Tic Disorder (연속수행검사에서 주의력결핍 과잉행동장애 감별 진단 시 임상 T-점수의 유용성 - 주의력결핍 과잉행동장애, 우울장애, 불안장애, 틱장애를 중심으로 -)

  • Yoon, Soo-Youn;Koo, Hoon-Jung;Kim, Boong-Nyun;Cho, Soo-Churl;Shin, Min-Sup
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.19 no.2
    • /
    • pp.112-119
    • /
    • 2008
  • Objectives : This study was conducted to examine whether there are qualitative differences in attention problem among children with various psychiatric disorders, including attention-deficit hyperactivity disorder (ADHD), depressive disorder, anxiety disorder, and tic disorder using clinical ADHD diagnostic system (ADS) T-scores. Methods : The subjects were 794 outpatient children aged from 5 to 15 years, including 540 children with ADHD, 95 children with depressive disorder, 86 children with anxiety disorder, and 73 children with tic disorder. Clinical T-scores on the ADS were calculated using the mean and standard deviations of four ADS variables for the ADHD group. Results : All four groups had T-scores on the ADS in the abnormal range. However, when comparing the clinical T-scores, the children with depressive and anxiety disorders performed better than the children with ADHD. We also found that although the four groups seemed to be similar in terms of clinical T-scores for omission and commission errors, there were significant differences in clinical T-scores for reaction time and the standard deviation of response time (RT) between the ADHD and other groups. Conclusions : We concluded that inattention and impulsivity might not be specific only to ADHD and that the clinical T-scores of RT and standard deviation of RT on the ADS could be used to discriminate between ADHD and other clinical groups.

  • PDF

A re-examination of the current design rule for staggered bolted connections

  • Xue-Mei Lin;Michael C.H. Yam;Ke Ke;Binhui,Jiang;Qun He
    • Steel and Composite Structures
    • /
    • v.46 no.3
    • /
    • pp.403-416
    • /
    • 2023
  • This paper summarised and re-examined the theoretical basis of the commonly used design rule developed by Cochrane in the 1920s to consider staggered bolt holes in tension members, i.e., the s2/4g rule. The rule was derived assuming that the term two times the bolt hole diameter (2d0) in Cochrane's original equation could be neglected, and assuming a value of 0.5 for the fractional deduction of a staggered hole in assessing the net section area. Although the s2/4g rule generally provides good predictions of the staggered net section area, the above-mentioned assumptions used in developing the rule are doubtful, in particular for a connection with a small gauge-to-bolt-hole diameter (g/d0) ratio. It was found that the omission of 2d0 in Cochrane's original equation appreciably overestimates the net section area of a staggered bolted connection with a small g/d0 ratio. However, the assumed value of 0.5 for the fractional deduction of a staggered hole underestimates the staggered net section area for small g/d0 ratios. To improve the applicability of the above two assumptions, a modified design equation, which covers a full range of g/d0 ratio, was proposed to accurately predict the staggered net section area and was validated by the existing test data from the literature and numerical data derived from this study. Finally, a reliability analysis of the test and numerical data was conducted, and the results showed that the reliability of the modified design equation for evaluating the net section resistance of staggered bolted connections can be achieved with the partial factor of 1.25.