• Title/Summary/Keyword: oil window

Search Result 36, Processing Time 0.017 seconds

Recovery of Silicon from Silicon Sludge by Electrolysis (실리콘 슬러지로부터 실리콘의 전해회수(電解回收))

  • Park, Jesik;Jang, Hee Dong;Lee, Churl Kyoung
    • Resources Recycling
    • /
    • v.21 no.5
    • /
    • pp.31-37
    • /
    • 2012
  • As a recovery of elemental silicon from the sludge of Si wafer process, a process of mechanical separation-chlorine roasting-electrolysis has been suggested. The silicon sludge consisted of Si, SiC, machine oil, and metallic impurities. The oil and metal impurities was removed by mechanical separation. The Si-SiC mixture was converted to silicon chloride by chlorine roasting at $1000^{\circ}C$ for 1 hr and the silicon chloride was dissolved into an ionic liquid of $[Bmpy]Tf_2N$ as an electrolyte. Cyclic voltammetry results showed an wide voltage window of pure $[Bmpy]Tf_2N$ and a reduction peak of elemental Si from $[Bmpy]Tf_2N$ dissolved $SiCl_4$ on Au electrode, respectively. The silicon deposits could be prepared on the Au electrode by the potentiostatic electrolysis of -1.9 V vs. Pt-QRE. The elemental silicon uniformly electrodeposited was confirmed by various analytical techniques including XRD, FE-SEM with EDS, and XPS. Any impurity was not detected except trace oxygen contaminated during handling for analysis.

Development of Single-Frame PIV Velocity Field Measurement Technique Using a High Resolution CCD Camera (고해상도 CCD카메라를 이용한 Single-Frame PIV 속도장 측정기법 개발)

  • Lee, Sang-Joon;Shin, Dae-Sig
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.1
    • /
    • pp.21-28
    • /
    • 2000
  • Although commercial PIV systems have been widely used for the non-intrusive velocity field measurement of fluid flows, they are still under development and have considerable room for improvement. In this study, a single-frame double-exposure PIV system using a high-resolution CCD camera was developed. A pulsed Nd:Yag laser and high-resolution CCD camera were synchronized by a home-made control circuit. In order to resolve the directional ambiguity problem encountered in the single-frame PIV technique, the second particle image was genuinely shifted in the CCD sensor array during the time interval dt. The velocity vector field was determined by calculating the displacement vector at each interrogation window using cross-correlation with 50% overlapping. In order to check the effect of spatial resolution of CCD camera on the accuracy of PIV velocity field measurement, the developed PIV system with three different resolution modes of the CCD camera (512 ${\times}$ 512, lK ${\times}$ IK, 2K ${\times}$ 2K) was applied to a turbulent flow which simulate the Zn plating process of a steel strip. The experimental model consists of a snout and a moving belt. Aluminum flakes about $1{\mu}m$ diameter were used as scattering particles for the liquid flow in the zinc pot and the gas flow above the zinc surface was seeded with atomized olive oil with an average diameter of 1-$3{\mu}m$. Velocity field measurements were carried out at the strip speed $V_s$=1.0 m/s. The 2K ${\times}$ 2K high-resolution PIV technique was significantly superior compared to the smaller pixel resolution PIV system. For the cases of 512 ${\times}$ 512 and 1K ${\times}$ 1K pixel resolution PIV system, it was difficult to get accurate flow structure of viscous flow near the wall and small vortex structure in the region of large velocity gradient.

Compatibility of Lithium ion Phosphate Battery in Solar off Grid Application

  • Lakshmanan, Sathishkumar;Vetrivel, Dhanapal;Subban, Ravi;R., Saratha;Nanjan, Sugumaran
    • Journal of Electrochemical Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.472-478
    • /
    • 2022
  • Solar energy harvesting is practiced by various nations for the purpose of energy security and environment preservation in order to reduce overdependence on oil. Converting solar energy into electrical energy through Photovoltaic (PV) module can take place either in on-grid or off-grid applications. In recent time Lithium battery is exhibiting its presence in on-grid applications but its role in off-grid application is rarely discussed in the literature. The preliminary capacity and Peukert's study indicated that the battery quality is good and can be subjected for life cycle test. The capacity of the battery was 10.82 Ah at 1 A discharge current and the slope of 1.0117 in the Peukert's study indicated the reaction is very fast and independent on rate of discharge. In this study Lithium Iron Phosphate battery (LFP) after initial characterization was subjected to life cycle test which is specific to solar off-grid application as defined in IEC standard. The battery has delivered just 6 endurance units at room temperature before its capacity reached 75% of rated value. The low life of LFP battery in off-grid application is discussed based on State of Charge (SOC) operating window. The battery was operated both in high and low SOC's in off-grid application and both are detrimental to life of lithium battery. High SOC operation resulted in cell-to-cell variation and low SOC operation resulted in lithium plating on negative electrode. It is suggested that to make it more suitable for off-grid applications the battery by default has to be overdesigned by nearly 40% of its rated capacity.

Traumatic Asphyxia with Compressive Thoracic Injuries -4 Cases Report- (흉부손상에 의한 외상성 가사 4예)

  • 김현순
    • Journal of Chest Surgery
    • /
    • v.13 no.3
    • /
    • pp.212-218
    • /
    • 1980
  • A severe crushing injury of the chest produce a very striking syndrome referred to as traumatic asphyxia. This syndrome is characterized by bluish-red discoloration of the skin which is limited to the distribution of the valveless veins of the head and neck. And also if it is characterized by bilateral subconjunctival hemorrhages and neurological manifestations. But these clinical entities faded away progressively in a few weeks. Apporximately 90% of the patients who live for more than a few hours will recover from traumatic asphyxia when it occurs as a single entity. And so, death results from either severe associated injuries of from subsequent infection, rather than from pulmonary or cardiac insufficiency in traumatic asphyxia. We have experienced 4 cases of traumatic asphyxia with severe crushing thoracic injuries at department of the chest surgery, Captial Armed forces General Hospital during about 3 years from April 1977 to Aug. 1980. The 1st 22 year-old male was struct 2$\frac{1}{2}$ ton truck on the road and was transferred to this hospital immediately. He had taken tracheostomy due to severe dyspnea with contusion pneumonia and for removal of a large amount of bronchial secretion. The 2nd case was 23 year-old male who was got buried in a chasm. In this case, the heavy metal post tumbled over him back while at work. The 3rd case was 39 year-old male who leapt out of a window in 5th story while fire broke out in living room by oil stove heating. He had multiple rib fracture with right hemothor x and right colle's fracture and pelvic bone fracture. The last 22 year-old male was run over by a gun carriage. The wheel of this gun carriage passed over his thorax and right chin. He was brought to this hospital by helicopter. when he was first examined at emergency room, he was in semicomatose state and has pneurmomediastinum with multiple rib fracture and severe subcutaneous emphysema. As soon as he arrived, bilateral closed thoracostomy was performed and cardiopulmonary resuscitation was done. In hospital 8th weeks, chest series showed fibrothorax in right side even if chest wall stabilized. All 4 cases had multiple petechiae over their facees and chest and bilateral subconjunctival hemorrhages referred to as traumatic asphyxia. 3 cases except one case who received splenectomy, had been suffered from contusion pneumonia and had been treated with respiratory care. In these 3 cases, they had warning of impending injury before accident, and took a deep breath hold it and braces himself. And also, even if he had not impending fear in remaining one case, he had taken a deep breath and had got valsalva maneuver for pulling off the heavy metal post. Intrathoracic pressure rose suddenly and resulted to traumatic asphyxia in this situation. All these cases were recovered completely without sequelae except one fibrothorax, right.

  • PDF

Analysis on Response System in US for Chemicals Driven Marine Pollution Accidents and Korean Response Policy Plan (화학물질 해양오염사고에 대한 미국의 방제체제 분석과 국내의 방제정책 방안)

  • Choi, Jong-Wook;Lee, Seung-Hwan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.15 no.3
    • /
    • pp.205-212
    • /
    • 2009
  • With an entry into force of OPRC-HNS on June 14th 2007, response system against any large scale accidents related to HNS is required to respond rapidly and effectively in a national scale, US national response system and national contingency plan for any chemicals in operation were analyzed to understand the characteristics of management system and response system for any HNS driven accidents in the Us. Main characteristics of the US system were well described as an unified information window and an integrated incident command system supported by response facilities, manpower and technical support from other response organizations through good cooperation. In general, response activities are conducted by private sectors, however, the government will take over response activities in case large scale accidents occur in the Us. Expected expenses for response activities are covered by a type of Superfund in the Us. Several applicable ways are proposed to enable NGO to participate in and reorganize response system in ROK, and are feasible in collaboration with other response organizations and private sectors in the aspects of equipment, technology and manpower, Based upon the above activities, it is desirable to reorganize domestic rules and/or regulations related to response measures in ROK.

  • PDF

Geochemical Characteristics of the Hydrocarbons from the Block 6-1, Ulleung Basin (울릉 분지 6-1 광구에서 발견된 탄화수소의 지화학적 특성)

  • Lee, Young-Joo;Cheong, Tae-Jin;Oh, Jae-Ho;Park, Se-Jin;Yi, Song-Suk
    • The Korean Journal of Petroleum Geology
    • /
    • v.11 no.1 s.12
    • /
    • pp.1-8
    • /
    • 2005
  • Seventeen exploratory wells have been drilled in the Block VI-1 of offshore Korea, which is located in the southern part or the Ulleung Basin. Gas show has been recognized from most of the wells, and gas and condensate have been accompanied in some wells. Commercial discovery of gas, accompanied by condensate, has been made from Gorae V well. The reservoir gases or the Dolgorae III, Gorae I, and Gorae V wells in the Ulleung Basin mainly consists of hydrocarbon gases (>93%). These gases are thermogenic wet gases which contain more than 96% of the methane and result from the cracking of petroleum or kerogen. Based on the chemistry and composition of the gases and stable isotope data, they seem to be generated from different source rocks. The condensates from the Gorae I and V wells are mostly generated from terrestrial organic matter. Lacustrine organic matter may not play an important role for the generation of these condensates. The condensates from the Gorae V wells consist predominantly of terrestrial organic matter but with minor subsidiary input from marine organic matter. The condensates from Gorse I and V wells may be generated from different source rocks. The thermal maturity level of the condensates from the Gorae V well ranges from early to middle oil generation zone and condensate from Gorae I reaches middle oil window. Correlation or the thermal maturation level of the condensates and organic matter in the sediments reveals that a depth of the generation of liquid hydrocarbons can be inferred to 3,000 m and 3,900 m for the Gorae V and I wells, respectively. Gorae V well, however, did not reach the target depth and the geochemical data of the Gorae I well were obscured due to the severe sediment caving in.

  • PDF