• 제목/요약/키워드: oil removal

검색결과 377건 처리시간 0.028초

하수처리장의 유지제거에 대한 연구 (A Study on the Removal of Grease and Oill in the Treatment Plant)

  • 박재효
    • 한국환경보건학회지
    • /
    • 제7권1호
    • /
    • pp.1-7
    • /
    • 1981
  • During 20 days from November 4 to 28, 1980, the quantities of grease and oil, BOD (biological oxygen demand), COD (chemical oxygen demand), SS (suspended solid) were measured at Grit Chamber, Primary Sedimentation Tank, Secondary Sedimentation Tank in Chung Gye Chun sewage treatment plant. The results were as follows. 1. The average of grease and oil quantities were 251mg/l at Grit Chamber, 185mg/l at Primary Sedimentation Tank, 47mg/l at Secondary Sedimentation Tank. 2. In the secondary treatment for the removal of grease and oil, the removed quantities of grease and oil were increased according to increasing the quantities of influent grease and oil. The regression equation were as follows G.O.removed=0.731 G.O. influent+3.235 (r=0.887) 3. The average of grease and oil removal rate was 76.4% and the standard deviation of grease and oil removal rate daily was 10.6%. 4. G.O. (grease and oil) and BOD, COD, SS showed significant correlationship at Grit Chamber, Primary Sedimentation Tank, Secondary Sedimentation Tank. (P<0.05). 5. In the secondary treatment, effluent grease & oil and other parameters were analyzed by means of Stepwise multiple regression. Multple regression equation for estimates of effluent grease and oil were as follows. $GO_E=-9.1637+2.0380 SS_E+0.068 SS_I$ (r=0.778) 6. The correlative parameters for the effluent grease and oil seem to be the influent SS and the effluent SS. 7. It was estimated that the removal of grease and oil would be improved by means of improvement of suspended solids removal efficiency but it is necessary to inquire further into the study.

  • PDF

프로테아제와 리파제의 혼합에 따른 세척성의 변화 (Effects of Mixing Protease and Lipase on Detergency)

  • 서수진;박정희
    • 한국의류학회지
    • /
    • 제24권2호
    • /
    • pp.205-213
    • /
    • 2000
  • This study investigated the effect of mixing protease and lipase on detergency. The detergency of protein soiled, oil soiled and protein-oil soiled cloths and the relative hydrolytic activity of enzymes were examined. The protease-lipase added detergent solution was most effective for the removal of protein in protein-oil soiled cloths. This is because the lipase removed the protein that was physically bound to oil as well as the protease removed the protein. The protease added detergent solution was second effective, the lipase added detergent solution was third effective, and the detergent solution without protease and lipase was the least effective. The protease-lipase added detergent solution was also most effective in the oil removal from protein-oil soiled cloths. Unlike in protein removal, however, the protease added detergent solution was more effective in oil removal than the lipase added detergent solution. This is because the removal of oil bound to protein by protease was more effective than the removal of oil by lipase. In soiling-washing cycles, however, the effects of lipase increased, and as a result, the detergency of protease added detergent solution and the lipase added detergent solution became similar.

  • PDF

유침절연 변압기에서 연속적 수분제거 유효성에 관한 연구 (Study on the Effectiveness of Continuous Water Removal in Oil Immersed Transformers)

  • 선종호;황돈하;김진수
    • 조명전기설비학회논문지
    • /
    • 제30권2호
    • /
    • pp.20-25
    • /
    • 2016
  • This paper describes the effectiveness of continuous water removal in oil immersed transformers. Insulation oil in which insulation papers were immersed were prepared for tests and water concentrations in oil with heating time were measured at five oil temperatures. Also, the tests that water dissolved in $100^{\circ}C$ oil was removed at once and continuously at $50^{\circ}C$ and $100^{\circ}C$ were performed for consideration of effective method for water removal. Test results indicated that the oils for water measurement have to be extracted at similar temperatures and water in oil has to be continuously removed at higher temperatures for more effective water management of transformers.

Optimization of operating parameters to remove and recover crude oil from contaminated soil using subcritical water extraction process

  • Taki, Golam;Islam, Mohammad Nazrul;Park, Seong-Jae;Park, Jeong-Hun
    • Environmental Engineering Research
    • /
    • 제23권2호
    • /
    • pp.175-180
    • /
    • 2018
  • Box-Behnken Design (BBD) under response surface methodology (RSM) was implemented to optimization the operating parameters and assess the removal and recovery efficiencies of crude oil from contaminated soil using subcritical water extraction. The effects of temperature, extraction time and water flow rate were explored, and the results indicate that temperature has a great impact on crude oil removal and recovery. The correlation coefficients for oil removal ($R^2=0.74$) and recovery ($R^2=0.98$) suggest that the proposed quadratic model is useful. When setting the target removal and recovery (>99%), BBD-RSM determined the optimum condition to be a temperature of $250^{\circ}C$, extraction time of 120 min, and water flow rate of 1 mL/min. An experiment was carried out to confirm the results, with removal and recovery efficiencies of 99.69% and 87.33%, respectively. This result indicates that BBD is a suitable method to optimize the process variables for crude oil removal and recovery from contaminated soil.

MHD 수처리방식에 의한 에멀젼오일폐수의 처리 (Emulsified Oily Wastewater Treatment by MHD Water Treatment Device)

  • 김인수;박승조
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제17권4호
    • /
    • pp.20-27
    • /
    • 1993
  • Emulsified oily wastewater is generally hard to treat in separating oil and water by conventional separators. In this paper the magnetohydrodynamic water treatment device was used to separate oil from emulsified oily wastewater which contained high conductivity. The emulsified oil removal rates and economic ranges of oil separation at various factors were investigated to confirm the influence of the magnetic field in MHD water treatment device according to the characteristics of emulsion brake. Experimental results proved that the oil removal rates were proportional to Lorentz force which depends on the intensity of magnetic field, conductivity and velocity of wastewater.

  • PDF

프로테아제와 리파제가 직물의 세척에 미치는 영향 (The Effects of Protease and Lipase on the Detergency of Fabrics)

  • 이정숙;정소화
    • 한국의류산업학회지
    • /
    • 제2권4호
    • /
    • pp.339-345
    • /
    • 2000
  • The effects of protease and/or lipase on the removal of protein soil and oily soil were investigated in this study. Cotton, rayon, nylon, and PET fabrics were soiled by padding of fresh bovine blood and spotting of mixed artificial sebum evenly. The soiled fabrics were aged at $130^{\circ}C$ for 30 minutes. The fabrics were washed by using Terg-O-Tometer at various conditions. Protease and/or lipase were added in the alcohol ethoxylate (AE) detergent solution. The removal efficiency was evaluated by analysis of protein and/or oil on the fabrics before and after washing, respectively. The detergency of protein and/or oil on the fabrics was discussed with enzyme concentration, washing time, washing temperature, pH of washing solution and fiber characteristics. The hydrolysis of protease improved effectively the removal of oil as well as protein by increasing removal of protein-oil mixed soil at the same time. The effect of lipase added detergent solution was slightly shown on the removal of oil and/or protein. The removal of mixed soils from cotton fabrics was very low because of large amount of residual soils caused by the physical characteristics of cotton fiber.

  • PDF

토양세정 기술을 활용한 윤활유와 아연 복합오염 철도토양의 정화 연구 (Feasibility Study on Soil Flushing for Railway Soil Contaminated with Lubricant Oil and Zinc)

  • 박성우;조정민;이재영;박준규;백기태
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제16권4호
    • /
    • pp.31-37
    • /
    • 2011
  • The feasibility study of soil flushing was investigated to remediate lubricant oil and zinc contaminated railway soil. In this study, mixed washing agents of surfactant and inorganic acid/base were used for the simultaneous removal. The mixed washing agent of non-ionic surfactant and HCl removed 15% of the lubricant oil and 40% of zinc, respectively. Alkaline-enhanced soil washing process increased the removal of lubricant oil up to 40%. This is because alkaline solution reduced the interfacial tension between water phase and lubricant oil phase due to the soap formation reaction. To simulate in-situ soil flushing for the remediation of railroad-related contamination, two dimensional soil flushing was carried out based on the results of batch soil washing. In the soil flushing, the removal efficiencies of lubricant oil and zinc were 34% and 16%, respectively. Even though the removal efficiency was low, the mixed washing agent can remove metal and lubricant oil simultaneously.

침엽수를 이용한 암모니아 가스 제거효율 연구 (Study of ammonia-gas removal′s characteristics using wood-material)

  • 박영규
    • 환경위생공학
    • /
    • 제19권2호
    • /
    • pp.7-14
    • /
    • 2004
  • This paper was investigated to clarify the possibility of ammonia-gas removal by essential oil. First of all, the chemical analysis was performed to analyze the composition of an essential oil by GC-MS. The monoterpenes in an essential oil react with ammonia by neutralization and their reaction mechanism was elucidated. Based on their chemical neutralized reaction, the removal efficiencies of ammonia gas were studied to derive the optimal conditions in the scrubber tower such as optimal temperature and pH. The experimental result shows that the removal efficiency of ammonia gas was achieved over 80 % by the misty aerosol dispersion of scrubber tower.

통합형 오일 정제 시스템의 개발 (Development of an Integrated Oil Purification System)

  • 홍성호;이경희;정남화
    • Tribology and Lubricants
    • /
    • 제38권4호
    • /
    • pp.121-127
    • /
    • 2022
  • This study presents the development of an integrated oil purification system consisting of moisture removal, oil flushing, and oil filtering devices. In this system, the oil flushing device is combined with a micro-bubble generator. Oil purification is necessary for ensuring the high performance of the lubricant through the efficient removal of contaminants and thus enables good maintenance of mechanical systems. The developed purification system removes moisture, varnish, and solid particles. Moreover, during oil purification, the oil flushing device separates foreign materials and contaminants remaining in the lubricating oil piping or mechanical systems. The microbubble generator, which is combined with the oil flushing device, can separate harmful contaminants, such as sludge, wear particles, and rust, from piping or lubrication systems through the cavitation effect. Moisture is removed using a double high-vacuum chamber, while sludge and varnish are removed via electro-absorption using a high-voltage generator. Additionally, the total maintenance cost of the system is reduced through the use of domestically fabricated cartridge filters composed of glass fiber and cellulose. The heater, which maintains the temperature of the lubricant at 60℃, can process 41,000 L of lubricant simultaneously. Multiple tests confirmed that the proposed integrated purification system exhibits good performance in oil flushing and removal of water and varnish.

2단 실린더형 싸이클론의 물 및 오일 액적 제거 성능 분석 연구 (Evaluation of removal performance of a novel two-stage cylinder type cyclone against water and oil droplets)

  • 김수민;김학준;김명준;한방우;우창규;김용진
    • 한국입자에어로졸학회지
    • /
    • 제13권3호
    • /
    • pp.119-125
    • /
    • 2017
  • A novel two stage cylindrical cyclone was developed for a 3 phase separator in shale oil production industry. The cyclone performance was compared with a cone type cyclone and multi cyclone at the same experimental condition using water and oil mists generated by a humidifier and atomizer at the flow rate 1 to $2m^3/min$. The removal efficiency of total suspended water droplets by the novel cyclone, calculated using inlet and outlet concentrations measured by an optical particle counter, was 99% which is higher than 90% of oil droplet removal efficiency at $2m^3/min$. It might be due to the evaporation of small water droplets during the tests. The water and oil droplet removal performance of the novel cyclone based on the quality factor which is a function of pressure drop and removal efficiency was the highest among three cyclones. The results indicate that the cyclone could be an economical device to remove water and oil mists from shale gas generation processes where a huge three phase separator is commonly used.