• 제목/요약/키워드: off-site risk

Search Result 72, Processing Time 0.031 seconds

Multi-unit Level 3 probabilistic safety assessment: Approaches and their application to a six-unit nuclear power plant site

  • Kim, Sung-yeop;Jung, Yong Hun;Han, Sang Hoon;Han, Seok-Jung;Lim, Ho-Gon
    • Nuclear Engineering and Technology
    • /
    • v.50 no.8
    • /
    • pp.1246-1254
    • /
    • 2018
  • The importance of performing Level 3 probabilistic safety assessments (PSA) along with a general interest in assessing multi-unit risk has been sharply increasing after the Fukushima Daiichi nuclear power plant (NPP) accident. However, relatively few studies on multi-unit Level 3 PSA have been performed to date, reflecting limited scenarios of multi-unit accidents with higher priority. The major difficulty to carry out a multi-unit Level 3 PSA lies in the exponentially increasing number of multi-unit accident combinations, as different source terms can be released from each NPP unit; indeed, building consequence models for the astronomical number of accident scenarios is simply impractical. In this study, a new approach has been developed that employs the look-up table method to cover every multi-unit accident scenario. Consequence results for each scenario can be found on the table, established with a practical amount of effort, and can be matched to the frequency of the scenario. Preliminary application to a six-unit NPP site was carried out, where it was found that the difference between full-coverage and cut-off cases could be considerably high and therefore influence the total risk. Additional studies should be performed to fine tune the details and overcome the limitations of the approach.

Development of Risk Representation System for Chemical Plane (화학공장의 위험도 표현 시스템 개발)

  • Ko Jae Wook;Lee Jung Woo;Lim Dong Ho
    • Journal of the Korean Institute of Gas
    • /
    • v.9 no.2 s.27
    • /
    • pp.28-33
    • /
    • 2005
  • Because chemical industrial facilities deal with large amount of hazardous materials, the damage affect to off-site as well as on-site when an accident occurs. So it is necessary to develop a Risk Representation System for effective control and response to major accidents. In this study a Risk Representation System(S/W) was developed to help analyzing actual risk and to set an alternative that can reduce the analyzed risk by drawing the level of individual plant's risk on a digital map network.

  • PDF

Modular reactors: What can we learn from modular industrial plants and off site construction research

  • Paul Wrigley;Paul Wood;Daniel Robertson;Jason Joannou;Sam O'Neill;Richard Hall
    • Nuclear Engineering and Technology
    • /
    • v.56 no.1
    • /
    • pp.222-232
    • /
    • 2024
  • New modular factory-built methodologies implemented in the construction and industrial plant industries may bring down costs for modular reactors. A factory-built environment brings about benefits such as; improved equipment, tools, quality, shift patterns, training, continuous improvement learning, environmental control, standardisation, parallel working, the use of commercial off shelf equipment and much of the commissioning can be completed before leaving the factory. All these benefits combine to reduce build schedules, increase certainty, reduce risk and make financing easier and cheaper.Currently, the construction and industrial chemical plant industries have implemented successful modular design and construction techniques. Therefore, the objectives of this paper are to understand and analyse the state of the art research in these industries through a systematic literature review. The research can then be assessed and applied to modular reactors.The literature review highlighted analysis methods that may prove to be useful. These include; modularisation decision tools, stakeholder analysis, schedule, supply chain, logistics, module design tools and construction site planning. Applicable research was highlighted for further work exploration for designers to assess, develop and efficiently design their modular reactors.

A Study on Development of Pre-Hazards Risk Analysis Guide Tool (연구실 위험분석을 위한 사전유해인자 가이드 Tool 개발 연구)

  • Choi, Byeong Kyu;Rhie, Kwang Won
    • Journal of the Korea Safety Management & Science
    • /
    • v.19 no.4
    • /
    • pp.133-140
    • /
    • 2017
  • The Ministry of Science, ICT and Future Planning made law for Pre-Hazard Risk Analysis in December 31, 2014 to protect researchers from continuing accidents in laboratory. Conducted before an experiment, Pre-Hazard Risk Analysis finds hazards of the experiment and rules to manage the hazards.So the Pre-Hazard Risk Analysis can support laboratory safety system by prevent accidents in laboratory. Pre-Hazards Risk Analysis is newly created system so that executors need Guidelines to perform this analysis properly. This study is to develop guide tool for Pre-Hazard Risk Analysis by analyzing other risk assessment systems; PSM, Off-site Consequence Assessment, laboratory safety system. Also, this study suggested how to establish database for Pre-Hazard Risk Assessment by analyse KRAS.

Establishment of the Appropriate Risk Standard through the Risk Assessment of Accident Scenario (사고시나리오별 위험도 산정을 통한 적정 위험도 기준 설정)

  • Kim, Kun-Ho;Chun, Young-Woo;Hwang, Yong-Woo;Lee, Ik-Mo;Kwak, In-ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.2
    • /
    • pp.74-81
    • /
    • 2017
  • An off-site consequence analysis is used to calculate the risks when hazardous chemicals that is being used on-site has been exposed off-site; the biggest factor that impacts the risk is the risks of accident scenarios. This study seeks to calculate risks according to accident scenarios by applying OGP/LOPA risk calculating methods for similar facilities, calculate risk reduction ratio by inspecting applicable IPL for incidents, and propose an appropriate risk standard for different risk calculating methods. Considering all applicable IPL when estimating the safety improvement of accident scenarios, the risk of OGP is 8.05E-04 and the risk of LOPA is 1.00E-04, According to the case of IPL, the risk is 1.34E-02. The optimal risk level for accident scenarios using LOPA was $10^{-2}$, but the appropriate risk criteria for accident scenarios in foreign similar studies were $10^{-3}{\sim}10^{-4}$, the risk of a scenario can be determined at an unacceptable level. When OGP is applied, it is analyzed as acceptable level, but in case of applying LOPA, all applicable IPL should be applied in order to satisfy the acceptable risk level. Compared to OGP, the risk is high when LOPA is applied. Therefore, the acceptable risk level should be set differently for each risk method.

A Study on the Simplified Estimating Method of Off-site Consequence Analysis by Concentration of Hydrochloric Acid (염산수용액의 농도별 간이 영향 평가 방법 연구)

  • Jung, Y.k.;Kim, B.;Heo, H.;Yoo, B.;Sin, C.;Yoon, Y.;Yoon, J.;Ma, B.
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.2
    • /
    • pp.52-58
    • /
    • 2017
  • One of the most important elements of the management of chemical accident is threat zone estimation of fires, explosions and toxic gas dispersion based on chemical releases. The threat zone estimation is going to be standard of emergency response for the first defender and base line data of off-site risk assesment (hereinafter referred to as "ORA") and risk management plan (hereinafter referred to as "RMP"). Generally, ALOHA form EPA(U.S.) and Kora(from KOREA MINISTRY OF ENVIRONMENT) has been used for the off-site consequence analysis in Korea. However it is hard to predict accurate consequences rapidly in case of emergency. Hydrochloric acid is a multipurpose raw material used in many industrial applications such as chemical, metal and food industries. It is usually treated in concentrations from 10 ~ 35 %, and release accident have occurred frequently. In this study, we have developed a simplified estimating method and equation to calculate threat zone easily in case of emergency due to release accident of hydrochloric acid.

Damage Effects Modeling by Chlorine Leaks of Chemical Plants (화학공장의 염소 누출에 의한 피해 영향 모델링)

  • Jeong, Gyeong-Sam;Baik, Eun-Sun
    • Fire Science and Engineering
    • /
    • v.32 no.3
    • /
    • pp.76-87
    • /
    • 2018
  • This study describes the damage effects modeling for a quantitative prediction about the hazardous distances from pressurized chlorine saturated liquid tank, which has two-phase leakage. The heavy gas, chlorine is an accidental substance that is used as a raw material and intermediate in chemical plants. Based on the evaluation method for damage prediction and accident effects assessment models, the operating conditions were set as the standard conditions to reveal the optimal variables on an accident due to the leakage of a liquid chlorine storage vessel. A model of the atmospheric diffusion model, ALOHA (V5.4.4) developed by USEPA and NOAA, which is used for a risk assessment of Off-site Risk Assessment (ORA), was used. The Yeosu National Industrial Complex is designated as a model site, which manufactures and handles large quantities of chemical substances. Weather-related variables and process variables for each scenario need to be modelled to derive the characteristics of leakage accidents. The estimated levels of concern (LOC) were calculated based on the Gaussian diffusion model. As a result of ALOHA modeling, the hazardous distance due to chlorine diffusion increased with increasing air temperature and the wind speed decreased and the atmospheric stability was stabilized.

A Study on Application Method & System Introduction of Laboratory Pre-hazards Risk Analysis (연구실 사전유해인자위험분석 적용방안 및 제도도입 연구)

  • Cho, Nam Joon;Ji, Yong Gu
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.4
    • /
    • pp.126-135
    • /
    • 2016
  • The purpose of this study is to develop risk assessment techniques and institutional analysis of domestic and international, the management techniques that can efficiently manage the harmful factor of the laboratory and to present the institutional measures that can be efficiently implemented. Due to a variety of adverse factors of laboratory, accidents of laboratory of various forms have occurred, but there is no risk assessment system in order to manage this effectively. So, we investigated this domestic existing risk assessment methods and the outside of the risk assessment system, and also analyzed accidents of domestic laboratory that occurred in 2014. In addition, we targeted the 24 laboratories in 21 universities to investigate the management of harmful factors of the laboratory and performed applying test for 12 domestic laboratories. Existing risk evaluation system, such as PMS, SMS, off-site impact assessment, since the industrial site is the subject, is a difficult problem to be directly applied to the laboratory of the research institute. So, we implemented management status and harmful factors survey and classified the research and development activities based on this data. Finally we developed "pre-hazards risk analysis method" to create each of the safety management measures. In addition, research activities personnel conducted voluntarily risk assessment, which is shared by institutions and government. It is presented the institutional system for safety management of laboratory. Its result, pre-hazards risk analysis method and institutionalization scheme will be able to achieve laboratory accident prevention system.

Trend in Off-Line PD Monitoring with HVAC Testing (배전반 설비의 온라인 모니터링 및 진단의 동향)

  • Yun, Ju-Ho;Hong, Chang-Il;Hwang, Jong-Sun;Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.529-530
    • /
    • 2007
  • The paper considers the relation between on-line monitoring and diagnostics on the one hand and high-voltage (HV) withstand and partial discharge (PD) on-site testing on the other. HV testing supplies the basic data (fingerprints) for diagnostics. In case of warnings by on-line diagnostic systems, off-line withstand and PD testing delivers the best possible information about defects and enables the classification of the risk. Because alternating voltage (AC) is the most important test voltage, the AC generation on site is considered. Frequency tuned resonant (ACRF) test systems are best adapted to on-site conditions. They can be simply combined with PD measuring equipment. The available ACRF test systems and their application to electric power equipment -from cable systems to power transformers - is described.

  • PDF