• Title/Summary/Keyword: off-pump

Search Result 301, Processing Time 0.031 seconds

Design Method for Cast-in-place Energy Pile Considering Equivalent Heat Exchange Rate (등가열교환율을 적용한 현장타설 에너지파일 설계법)

  • Min, Sunhong;Park, Sangwoo;Jung, Kyoungsik;Choi, Hangseok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.3
    • /
    • pp.1049-1061
    • /
    • 2013
  • In this paper, a relative heat exchange rate is numerically compared for cast-in-place concrete energy piles with different heat exchange pipe configurations, and a new design method for energy piles is proposed. An equivalent heat exchange rate was estimated for the W-type (one series loop), multiple U-type (four parallel loops), and coil-type heat exchanger installed in the same large-diameter drilled shaft. In order to simulate a cooling operation in summer by a CFD analysis, the LWT (leaving water temperature) into a energy pile was fixed at $35^{\circ}C$ and then the EWT (entering water temperature) into a heat pump was monitored. In case of continuously applying the artificial maximum cooling load for 100 hours, all of the three types of heat exchangers show the marginally similar heat exchange rate. However, in case of intermittently applying the cooling load with a cycle of 8 hours operation-16 hours off for 7 consecutive days, the coil type heat exchanger exhibits a heat exchange rate only 86 % of the multiple U-type due to measurable thermal interference between pipe loops in the energy pile. On the other hand, the W-type possesses the similar heat exchange rate to the multiple U-type. The equivalent heat exchange rates for each configuration of heat exchangers obtained from the CFD analysis were adopted for implementing the commercial design program (PILESIM2). Finally, a design method for cast-in-place concrete energy piles is proposed along with a design chart in consideration of typical design factors.

An Adjustment Method for the Group Difference in the National Enterance Examination (수능시험 집단간 실력차이 보정방법에 관한 연구)

  • 남보우
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2002.05a
    • /
    • pp.1085-1092
    • /
    • 2002
  • 수십만명의 대입응시자와 대학입학을 준비하는 수백만명의 초중고등학교 학생들에게 공정한 경쟁의 규칙과 측정방법을 마련하여 적응하는 것은 매우 중요하다. 현행 대학입학 수학능력 시험에서 각 영역별 표준점수는 응시계열인 인문계열, 자연계열, 예체능계열로 나누어 각 계열의 평균과 표준편차를 사용하여 계산한다. 따라서 동일한 점수도 어느 응시계열에 속하는가에 따라 표준점수가 달라지게 되며, 상이한 표준점수를 사용하여 대등한 경쟁을 하는 경우가 있어 불공정성이 제기된다. 비록 변환표준점수로 조정하여 계열간 불공정이 어느 정도 조정되지만, 자신의 점수에 비하여 집단의 평균점수가 낮을수록 변환표준점수가 증가하게 되므로 계열선택의 영향이 없다고 보기 어렵다. 이러한 결과로 유리한 계열로 대거 이동하는 현상이 나타나고 있다. 본 연구는 대학입학에 필수적인 대학입학 수학능력시험에서 계열간 실력차이를 보정하여 공정한 경쟁을 가능하게 하는 표준점수 계산방법을 제시하였다. 또한 모든 과목이 선택과목이 되는 2005학년도부터 시행될 수학능력시험에서 과목간 표준점수를 보정하는 방법을 제시하였다 본 연구는 결론을 도출하는데 있어 응시자들간 표준점수의 차이는 응시과목에 따라 달라지지 않는다는 과목의 동질성을 가정하였다. 응시과목의 동질성 가정하에서 집단간의 표준점수를 보정하는 방식은 동일한 시험문제로 각 집단이 시험을 보는 경우 집단간의 차이만큼을 표준점수에 합하여 보정하고, 각 집단이 고유하게 응시하는 시험과목은 공통과목의 차이만큼을 각 집단에 보정하여 주는 것이다. 과목간에 표준점수를 보정하는 방식은 해당과목에 응시한 응시자들이 다른 과목에서 획득한 표준점수의 평균치로보정하는 것이다.하기 위해서, 기업간 프로세스 협업(collaboration) 부분의 데이터 및 서식, 이를 취급하는 기능과 프로세스에 대란 분석을 통해 업무 프로세스 모델링 방법론과 관련한 모델링 지침 및 메타모델을 이용한 표준 업무 프로세스 모델을 개발하여 기업간 업무 프로세스 표준화에 대한 체계적인 관리에 대한 방안을 연구하고자 한다.의Bullwhip effect를 감소시킬 수 있는 장점이 있다. 동시에 이것은 향후 e-Business 시스템 구축을 위한 기본 인프라 역할을 수행할 수 있게 된다. 많았고 년도에 따른 변화는 보이지 않았다. 스키손상의 발생빈도는 초기에 비하여 점차 감소하는 경향을 보였으며, 손상의 특성도 부위별, 연령별로 다양한 변화를 나타내었다.해가능성을 가진 균이 상당수 검출되므로 원료의 수송, 김치의 제조 및 유통과정에서 병원균에 대한 오염방지에 유의하여야 할 것이다. 확인할 수 있었다. 이상의 결과에 의하면 고농도의 유기물이 함유된 음식물쓰레기는 Hybrid Anaerobic Reactor (HAR)를 이용하여 HRT 30일 정도에서 충분히 직접 혐기성처리가 가능하며, 이때 발생된 $CH_{4}$를 회수하여 이용하면 대체에너지원으로 활용 가치가 높은 것으로 판단된다./207), $99.2\%$(238/240), $98.5\%$(133/135) 및 $100\%$ (313)였다. 각각 두 개의 요골동맥과 우내흉동맥에서 부분협착이나 경쟁혈류가 관찰되었다. 결론: 동맥 도관만을 이용한 Off pump CABG를 시행하여 감염의 위험성을 증가시키지 않으면서 영구적인 신경학적 합병증을 일으

  • PDF

The effects of continuous and intermittent compressive pressure on alkaline phosphatase activity of Periodontal Ligament cells (지속적 및 간헐적 가압력이 치주인대 배양세포의 Alkaline Phosphatase 활성도에 미치는 영향)

  • Kwon, Suk-Yee;Bae, Seong-Min;Kyung, Hee-Moon;Sung, Jae-Hyun
    • The korean journal of orthodontics
    • /
    • v.27 no.4 s.63
    • /
    • pp.599-605
    • /
    • 1997
  • The propose of this study was to evaluate the effect of cellular activity on PDL cells dependent on intermittent and continuous compressive force by determining the alkaline phosphatase activity. An intermittent and continuous compressive forces were applied on PDL cells at the confluent stage. The alkaline phosphatase activity was measured on control and experimental groups every 24, 48, 72hours. The experimental group were consist of continuous and intermittent compressive group which were compressed by $300g/cm^2$ of diaphram pump. The intermittent compressive group was connected by timer which was worked on 10 minutes and off 10minutes. The results were as follows ; 1. The alkaline phosphatase activity of intermittent compressive group was lower than control group at 24 hours(P<0.05). 2. The alkaline phosphatase activity between each groups showed no significant differences at 48hours. 3. The alkaline phosphatase activity of continuous compresssive group was significantly higher than control group at 72 hours(P<0.01).

  • PDF

Integrated RT-PCR Microdevice with an Immunochromatographic Strip for Colorimetric Influenza H1N1 virus detection

  • Heo, Hyun Young;Kim, Yong Tae;Chen, Yuchao;Choi, Jong Young;Seo, Tae Seok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.273-273
    • /
    • 2013
  • Recently, Point-of-care (POC) testing microdevices enable to do the patient monitoring, drug screening, pathogen detection in the outside of hospital. Immunochromatographic strip (ICS) is one of the diagnostic technologies which are widely applied to POC detection. Relatively low cost, simplicity to use, easy interpretations of the diagnostic results and high stability under any circumstances are representative advantages of POC diagnosis. It would provide colorimetric results more conveniently, if the genetic analysis microsystem incorporates the ICS as a detector part. In this work, we develop a reverse transcriptase-polymerase chain reaction (RT-PCR) microfluidic device integrated with a ROSGENE strip for colorimetric influenza H1N1 virus detection. The integrated RT-PCR- ROSGENE device is consist of four functional units which are a pneumatic micropump for sample loading, 2 ${\mu}L$ volume RT-PCR chamber for target gene amplification, a resistance temperature detector (RTD) electrode for temperature control, and a ROSGENE strip for target gene detection. The device was fabricated by combining four layers: First wafer is for RTD microfabrication, the second wafer is for PCR chamber at the bottom and micropump channel on the top, the third is the monolithic PDMS, and the fourth is the manifold for micropump operation. The RT-PCR was performed with subtype specific forward and reverse primers which were labeled with Texas-red, serving as a fluorescent hapten. A biotin-dUTP was used to insert biotin moieties in the PCR amplicons, during the RT-PCR. The RT-PCR amplicons were loaded in the sample application area, and they were conjugated with Au NP-labeled hapten-antibody. The test band embedded with streptavidins captures the biotin labeled amplicons and we can see violet colorimetric signals if the target gene was amplified with the control line. The off-chip RT-PCR amplicons of the influenza H1N1 virus were analyzed with a ROSGENE strip in comparison with an agarose gel electrophoresis. The intensities of test line was proportional to the template quantity and the detection sensitivity of the strip was better than that of the agarose gel. The test band of the ROSGENE strip could be observed with only 10 copies of a RNA template by the naked eyes. For the on-chip RT-PCR-ROSGENE experiments, a RT-PCR cocktail was injected into the chamber from the inlet reservoir to the waste outlet by the micro-pump actuation. After filling without bubbles inside the chamber, a RT-PCR thermal cycling was executed for 2 hours with all the microvalves closed to isolate the PCR chamber. After thermal cycling, the RT-PCR product was delivered to the attached ROSGENE strip through the outlet reservoir. After dropping 40 ${\mu}L$ of an eluant buffer at the end of the strip, the violet test line was detected as a H1N1 virus indicator, while the negative experiment only revealed a control line and while the positive experiment a control and a test line was appeared.

  • PDF

Remote Monitoring Panel and Control System for Chemical, Biological and Radiological Facilities (화생방 방호시설을 위한 원격감시 패널 및 제어시스템)

  • Park, Hyoung-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.1
    • /
    • pp.464-469
    • /
    • 2019
  • A remote monitoring panel and control system was developed to control various valves and access control chambers, including gas shutoff valves used in CBR(Chemical, Biological and Radiological) facilities. The remote monitoring panel consisted of a main panel installed in the NBC (Nuclear, Biological and Chemical) control room and auxiliary panel installed in the clean room, and the size was divided into pure control and control including CCTV. This system can be monitored and controlled remotely according to the situation where an explosion door and gas barrier door can occur during war and during normal times. This system is divided into normal mode and war mode. In particular, it periodically senses the operation status of various valves, sensors, and filters in the CBR facilities to determine if each apparatus and equipment is in normal operation, and remotely alerts situation workers when repair or replacement is necessary. Damage due to the abnormal operation of each device in the situation can be prevented. This enables control of the blower, supply and exhaust damper, emergency generator, and coolant pump according to the state of shutoff valve and positive pressure valve in the occurrence of NBC, and prevents damage caused by abrupt inflow of conventional weapons and nuclear explosions.

A Micro-Scale Photovoltaic Energy Harvesting Circuit Using Energy Distribution Technique (에너지 분배 기능을 이용한 마이크로 빛에너지 하베스팅 회로)

  • Lee, Shin-woong;Lee, Chul-woo;Yang, Min-Jae;Yoon, Eun-jung;Yu, Chong-gun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.10a
    • /
    • pp.581-584
    • /
    • 2014
  • In this paper, a micro-scale photovoltaic(PV) energy harvesting system is proposed where an MPPT(Maximum Power Point Tracking) control is implemented using an energy distribution technique. Miniature PV cells output very low energy and low voltages, and thus, they cannot be used to directly power the MPPT controller. In the proposed system, a start-up circuit boosts an internal Vcp, and the boosted Vcp is used to operate the internal MPPT control block. When the Vcp reaches a predefined value, a detector circuit makes the start-up block turn off and provide a power converter with the energy from the PV cell. When the Vcp decreases such that the MPPT controller can not be operated, the energy transferred to the power converter is blocked and the start-up circuit is reactivated. In this way, the MPPT function is achieved by alternately operating the start-up circuit and the power converter using the energy distribution technique, and the harvested energy is transferred to a load through a PMU(Power Management Unit). The proposed circuit is designed in a 0.35um CMOS process and its functionality has been verified through extensive simulations. The designed chip area including pads is $1430um{\times}1110um$.

  • PDF

Design and Development of Intelligent Cattle Shed for the Prevention of Livestock Waste (가축 폐사 방지를 위한 지능형 축사의 설계 및 개발)

  • Jang, Junewoo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2019.05a
    • /
    • pp.32-35
    • /
    • 2019
  • One of the major problems with the livestock industry is that in the summer, livestock will die from heat waves or infectious diseases. Under these circumstances, what livestock need is a proper indoor temperature and a regular sterilization system. Therefore, in this study, we developed a system that automatically controls the power of the fan according to the temperature inside the shaft, and a function that provides feed and sterilization on a regular basis, so that we could manage the toast efficiently. It also proposed the ability to automatically control the power of the fan, to display the temperature inside the shaft to mobile applications, and to provide food and sterilization. First, the function of controlling the power of the fan automatically turns the fan on when the temperature inside the shaft rises above a certain level. Conversely, if the temperature inside the shaft falls below a certain level, turn off the fan. Second, the function of the mobile application is to check the temperature inside the shaft. The third feeding function is periodically fed using a servo motor, and the feeding provided is delivered to livestock through a conveyor belt. Finally, the sterilization function is a function to sterilize livestock periodically using DC motor pump. The intelligent congratulatory functions proposed in this study may contribute to the health of livestock.

  • PDF

A Study on the Safety Distance of the Fuelling Facilities by the Radiation Heat in the Fire at the Gas Station (주유소 내 부대시설 화재발생시 복사열에 따른 주유설비 안전거리에 관한 연구)

  • Kim, Kisung;Lee, Sangwon;Song, Dongwoo
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.6
    • /
    • pp.7-13
    • /
    • 2021
  • Various research has been done on fires and explosions at gas stations at home and abroad. However, only studies of off-site damage in the event of fire at the gas station were conducted, and research on fire at the auxiliary facilities in the gas station was insufficient. The gas station is a place where anyone can easily access dangerous goods. As the risk of fire increases due to the recent increase of auxiliary facilities such as convenience stores and car repair shops in gas stations, it is important to detect the effects of fire on the main oil refinery in case of fire and to verify the validity of existing regulations. In this thesis, we conducted a study to find out the effect of radiation heat on the separation between fixed and fixed oil reactors in the event of fire at an auxiliary facility. Simulation was modelled using FDS 5.5.3 Version, and the size of the fire source was configured with 13 fire assessment devices and the heat emission rate per unit area was entered. Simulation shows that the separation distance of 2 m does not secure the safety of the gas pump in the event of fire at the auxiliary facilities, and radiation heat does not damage at the separation distance of at least 4 m. Accordingly, facilities that can block radiant heat in the event of fire at auxiliary facilities, and measures to limit the use of auxiliary facilities or to re-impose the separation between buildings and fixtures will be needed.

Compressed Demographic Transition and Economic Growth in the Latecomer

  • Inyong Shin;Hyunho Kim
    • Analyses & Alternatives
    • /
    • v.7 no.2
    • /
    • pp.35-77
    • /
    • 2023
  • This study aims to solve the entangled loop between demographic transition (DT) and economic growth by analyzing cross-country data. We undertake a national-level group analysis to verify the compressed transition of demographic variables over time. Assuming that the LA (latecomer advantage) on DT over time exists, we verify that the DT of the latecomer is compressed by providing a formal proof of LA on DT over income. As a DT has the double-kinked functions of income, we check them in multiple aspects: early maturation, leftward threshold, and steeper descent under a contour map and econometric methods. We find that the developing countries (the latecomer) have speedy DT (CDT, compressed DT) as well as speedy income such that DT of the latecomers starts at lower levels of income, lasts for a shorter period, and finishes at the earlier stage of economic development compared to that of developed countries (the early mover). To check the balance of DT, we classify countries into four groups of DT---balanced, slow, unilateral, and rapid transition countries. We identify that the main causes of rapid transition are due to the strong family planning programs of the government. Finally, we check the effect of latecomer's CDT on economic growth inversely: we undertake the simulation of the CDT effect on economic growth and the aging process for the latecomer. A worrying result is that the CDT of the latecomer shows a sharp upturn of the working-age population, followed by a sharp downturn in a short period. Compared to early-mover countries, the latecomer countries cannot buy more time to accommodate the workable population for the period of demographic bonus and prepare their aging societies for demographic onus. Thus, we conclude that CDT is not necessarily advantageous to developing countries. These outcomes of the latecomer's CDT can be re-interpreted as follows. Developing countries need power sources to pump up economic development, such as the following production factors: labor, physical and financial capital, and economic systems. As for labor, the properties of early maturation and leftward thresholds on DTs of the latecomer mean that demographic movement occurs at an unusually early stage of economic development; this is similar to a plane that leaks fuel before or just before take-off, with the result that it no longer flies higher or farther. What is worse, the property of steeper descent represents the falling speed of a plane so that it cannot be sustained at higher levels, and then plummets to all-time lows.

Left Ventricular Systolic Function Improvement after Surgical Revascularization in Postinfarction Angina (급성 심근 경색 후 협심증 환자에서의 관상동맥 우회술 후 좌심실 수축 기능의 호전)

  • Yi Gi-Jong;Park Seong-Yong;Hong You-Sun;Yoo Kyung-Jong;Chang Byung-Chul;Lim Sang-Hyun
    • Journal of Chest Surgery
    • /
    • v.39 no.9 s.266
    • /
    • pp.674-680
    • /
    • 2006
  • Background: Acute myocardial infarction (MI) is a life-threatening disease and surgical revascularization plays a major role in selected cases. The purpose of this study is to evaluate the left ventricular contractility improvement by examining the wall motion score index (WMSI) and left ventricular ejection fraction (LVEF) in patients who under-went surgical revascularization under diagnosis of acute MI. Material and Method: From January, 2001 to December, 2004, 149 patients who underwent coronary artery bypass surgery within 2 weeks of acute MI were included. We evaluated pre- and postoperative left ventricular contractility by measuring WMSI and LVEF and examined the associating factors. Result: WMSI decreased from $1.54{\pm}4.30\;to\;1.43{\pm}0.40$ (p<0.001) and LVEF increased from $48.1{\pm}12.2%\;to\;49.7{\pm}12.3%$ after surgery (p=0.009). Off-pump technique, non-Q wave, anterior MI, and surgery within 7 days after MI were favorable factors for LVEF improvement (p=0.046, p=0.006, p=0.003, p=0.005, respectively). Conversely, aforementioned factors were irrelevant with WMSI improvement. For triple vessel disease, complete revascularization was favorable factor for WMSI improvement (p<0.001). Conclusion: Coronary artery by-pass surgery can improve WMSI and LVEF in patients with acute MI. In case of anterior MI with non-Q wave, early surgical revascularization within 7 days may be most beneficial in LVEF improvement. Regarding WMSI, complete revascularization may be essential.