• Title/Summary/Keyword: off-pump

Search Result 301, Processing Time 0.023 seconds

Acute Respiratory Failure Treated with Veno-venous Extracorporeal Membrane Oxygenation (정-정맥 체외막형산소화요법을 이용한 급성호흡부전의 치료)

  • Kim, Hyoung-Soo;Han, Sang-Jin;Hong, Kyung-Soon;Yoon, Duck-Hyoung;Lee, Chang-Youl;Lee, Myung-Goo;Hong, Won-Ki;Lee, Sun-Hee;Kim, Kun-Il;Lee, Hee-Sung;Cho, Sung-Woo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.68 no.2
    • /
    • pp.62-66
    • /
    • 2010
  • Background: Extracorporeal membrane oxygenation (ECMO) during severe acute respiratory failure helps to recover the pulmonary function. This study evaluated our experience with veno-venous ECMO in adult patients with acute respiratory failure. Methods: From January 2007 to July 2009, ECMO was used on 54 patients. Of these 54 patients, 7 were placed on veno-venous ECMO for acute respiratory failure. The indications of ECMO were based on the lung dysfunction measured as a $PaO_2/FiO_2$ ratio <100 mm Hg on $FiO_2$ of 1.0, or an arterial blood gas pH <7.25 due to hypercapnia despite the optimal treatment. $EBS^{(R)}$, $Bio-pump^{(R)}$, and Centrifugal Rotaflow $pump^{(R)}$ were used and all cannulations were performed percutaneously via both femoral veins. When the lung function was improved, an attempt was made to wean on ECMO at moderate ventilator settings followed by decannulation. Results: Five of the 7 patients were male and the mean age was $46.3{\pm}18.3$. The causes of acute respiratory failure were 3 cases of pneumonia, 2 near-drownings, 1 pulmonary hemorrhage due to acute hepatic failure and 1 mercury vapor poisoning. The mean support time of ECMO was $17.3{\pm}13.7$ days. Of the 7 patients implanted with ECMO, 5 patients (71%) were weaned off ECMO and 3 patients (43%) survived to hospital discharge after a mean 89.6 hospital days. Conclusion: The early use of ECMO for acute respiratory failure in adults due to any cause is a good therapeutic option for those unresponsive to the optimal conventional treatments.

Fuel cell system for SUAV using chemical hydride - I. Lightweight hydrogen generation and control system (화학수소화합물을 이용한 소형 무인항공기용 연료전지 시스템 연구 - I. 경량 수소 발생 및 제어 장치)

  • Hong, Ji-Seok;Jung, Won-Chul;Kim, Hyeon-Jin;Lee, Min-Jae;Jeong, Dae-Seong;Jeon, Chang-Soo;Sung, Hong-Gye;Shin, Seock-Jae;Nam, Suk-Woo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.3
    • /
    • pp.226-232
    • /
    • 2013
  • A compact hydrogen generation device of fuel cell system using chemical hydride storage technique was designed to fit the propulsion device requirement of a small unmanned aerial vehicle(SUAV). For high efficient, compact, and lightweight hydrogen generation control device, the Co-B catalyst hydrogen conversion rate by $NaBH_4$ aqueous solution flux is measured so that the proper amount of Co-B catalyst for maximum hydrogen generation of 100W stack was proposed. A compact hydrogen generation device is controlled by pump's on/off using its own internal pressure and consumes fuel in high efficiency through a dead-end type fuel cell. The fuel cell system has stable operation for a planed flight profile. The system operates up to maximum 7 hours and at least 4 hours for tough flight profiles.

Water Balance Analysis of Pumped-Storage Reservoir during Non-Irrigation Period for Recurrent Irrigation Water Management (순환형 농업용수관리를 위한 농업용 저수지의 비관개기 양수저류 추정)

  • Bang, Na-Kyoung;Nam, Won-Ho;Shin, Ji-Hyeon;Kim, Han-Joong;Kang, Ku;Baek, Seung-Chool;Lee, Kwang-Ya
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.62 no.4
    • /
    • pp.1-12
    • /
    • 2020
  • The extreme 2017 spring drought affected a large portion of South Korea in the Southern Gyeonggi-do and Chungcheongnam-do districts. This drought event was one of the climatologically driest spring seasons over the 1961-2016 period of record. It was characterized by exceptionally low reservoir water levels, with the average water level being 36% lower over most of western South Korea. In this study, we consider drought response methods to alleviate the shortage of agricultural water in times of drought. It could be to store water from a stream into a reservoir. There is a cyclical method for reusing water supplied from a reservoir into streams through drainage. We intended to present a decision-making plan for water supply based on the calculation of the quantity of water supply and leakage. We compared the rainfall-runoff equation with the TANK model, which is a long-term run-off model. Estimations of reservoir inflow during non-irrigation seasons applied to the Madun, Daesa, and Pungjeon reservoirs. We applied the run-off flow to the last 30 years of rainfall data to estimate reservoir storage. We calculated the available water in the river during the non-irrigation season. The daily average inflow from 2003 to 2018 was calculated from October to April. Simulation results show that an average of 67,000 tons of water is obtained during the non-irrigation season. The report shows that about 53,000 tons of water are available except during the winter season from December to February. The Madun Reservoir began in early October with a 10 percent storage rate. In the starting ratio, a simulated rate of 4 K, 6 K, and 8 K tons is predicted to be 44%, 50%, and 60%. We can estimate the amount of water needed and the timing of water pump operations during the non-irrigation season that focuses on fresh water reservoirs and improve decision making for efficient water supplies.

Redo CABG through a Left Posterolateral Thoracotomy - A case report- (좌측 후측방개흉술을 이용한 관상동맥 우회 재수술 치험 1예)

  • Song, Chang-Min;Kim, Mi-Jung;Jeong, Seong-Cheol;Kim, Woo-Shik;Shin, Yong-Chul;Kim, Byung-Yul
    • Journal of Chest Surgery
    • /
    • v.41 no.3
    • /
    • pp.366-368
    • /
    • 2008
  • We report there on a 46-year-old male patient whose angina recurred after a coronary bypass graft (CABG). Occlusion of the first diagonal branch was found on performing a coronary angiogram (CAG), and this occlusion had not previously been present. So, a redo-off pump CABG was performed via a left posterolateral thoracotomy. The anastomosis was made between the descending thoracic aorta and the diagonal branch by using the right radial artery. On the Multi-detector computerized tomography (MDCT) coronary angiogram conducted after the operation, it was confirmed that there was no abnormality in the anastomosis site. A Redo-CABG was successfully performed via left posterolateral thoracotomy in the patient whose disease was only at the diagonal branch.

Clinical Experiences of MIDCAB - Developmental Stage and Early Short-term Results - (최소침습적 관상동맥우회술의 발전단계와 경험에 대한 고찰)

  • 이영탁;정철현
    • Journal of Chest Surgery
    • /
    • v.32 no.11
    • /
    • pp.1009-1016
    • /
    • 1999
  • Background: Minimally invasive direct coronary artery bypass surgery(MIDCAB) has been increasing in interest along with the new techniques in myocardial immobilization for easier and safer procedures. Until the opening of the era of new techniques, adequate accuracy and good patency of grafts were debatable. Our experiences of MIDCAB were studied according to the stages of technical developments. Material and Methods: Since March 1996, 55 patients have undergone MIDCAB procedures. The patients of off-pump CABG(no cardiopulmonary bypass under full sternotomy) were excluded from the study. In the early experience(Stage I), a left anterior small thoracotomy through the left parasternal incision was performed(n=6); then an approach through the lower partial sternotomy was used(Stage II, n=33); and recently, a chest wall elevator for harvesting the internal thoracic artery and the foot plate for myocardial immobilization have been used(USSC, Norwalk, CT)(Stage III, n=16). Result: The surgical procedures of four patients in the Stage II group have been converted to conventional bypass because of the deeply seated left anterior descending coronary artery in two patients, fracture of the calcific lesion in the right coronary artery in one patient, and a cardiogenic shock during hypothermia in the other patient with ventricular dysfunction. Two patients in stage II experienced symptomatic recurrences after surgery and restenosis was verified on angiocardiography. They were managed by interventional procedures. All the other patients were doing well without symptoms, except one patients in Stage II who underwent PTCA procedure for a lesion in the circumflex artery during the follow up period. Conclusion: The new and specialized devices are essential to the development of MIDCAB surgery. MIDCAB and the hybrid procedures in multi-vessel disease are on the way to further development. So far, our experience is limited only to a single device among the many new devices for the purpose.

  • PDF

A New Photovoltaic System Architecture of Module-Integrated Converter with a Single-sourced Asymmetric Multilevel Inverter Using a Cost-effective Single-ended Pre-regulator

  • Manoharan, Mohana Sundar;Ahmed, Ashraf;Park, Joung-Hu
    • Journal of Power Electronics
    • /
    • v.17 no.1
    • /
    • pp.222-231
    • /
    • 2017
  • In this paper, a new architecture for a cost-effective power conditioning systems (PCS) using a single-sourced asymmetric cascaded H-bridge multilevel inverter (MLI) for photovoltaic (PV) applications is proposed. The asymmetric MLI topology has a reduced number of parts compared to the symmetrical type for the same number of voltage level. However, the modulation index threshold related to the drop in the number of levels of the inverter output is higher than that of the symmetrical MLI. This problem results in a modulation index limitation which is relatively higher than that of the symmetrical MLI. Hence, an extra voltage pre-regulator becomes a necessary component in the PCS under a wide operating bias variation. In addition to pre-stage voltage regulation for the constant MLI dc-links, another auxiliary pre-regulator should provide isolation and voltage balance among the multiple H-bridge cells in the asymmetrical MLI as well as the symmetrical ones. The proposed PCS uses a single-ended DC-DC converter topology with a coupled inductor and charge-pump circuit to satisfy all of the aforementioned requirements. Since the proposed integrated-type voltage pre-regulator circuit uses only a single MOSFET switch and a single magnetic component, the size and cost of the PCS is an optimal trade-off. In addition, the voltage balance between the separate H-bridge cells is automatically maintained by the number of turns in the coupled inductor transformer regardless of the duty cycle, which eliminates the need for an extra voltage regulator for the auxiliary H-bridge in MLIs. The voltage balance is also maintained under the discontinuous conduction mode (DCM). Thus, the PCS is also operational during light load conditions. The proposed architecture can apply the module-integrated converter (MIC) concept to perform distributed MPPT. The proposed architecture is analyzed and verified for a 7-level asymmetric MLI, using simulation results and a hardware implementation.

Subxiphoid Incisional Hernia Development after Coronary Artery Bypass Grafting

  • Kim, Hye-Seon;Kim, Ki-Bong;Hwang, Ho-Young;Chang, Hyung-Woo;Park, Kyu-Joo
    • Journal of Chest Surgery
    • /
    • v.45 no.3
    • /
    • pp.161-165
    • /
    • 2012
  • Background: Median sternotomy can weaken the upper abdominal wall and result in subxiphoid incisional hernia. We evaluated risk factors associated with the development of subxiphoid incisional hernias after coronary artery bypass grafting (CABG). Materials and Methods: Of 1,656 isolated CABGs performed between January 2001 and July 2010, 1,599 patients who were completely followed up were analyzed. The mean follow-up duration was $49.5{\pm}34.3$ months. Subxiphoid incisional hernia requiring surgical repair developed in 13 patients (0.8%). The hernia was diagnosed $16.3{\pm}10.3$ months postoperatively, and hernia repair was performed $25.0{\pm}26.1$ months after the initial operation. Risk factors associated with the development of subxiphoid incisional hernia were analyzed with the Cox proportional hazard model. Results: Five-year freedom from the hernia was 99.0%. Univariate analysis revealed that female sex (p=0.019), height (p=0.019), body surface area (p=0.046), redo operation (p=0.012), off-pump CABG (p=0.049), a postoperative wound problem (p=0.041), postoperative bleeding (p=0.046), and low cardiac output syndrome (p<0.001) were risk factors for the development of the hernia. Multivariable analysis showed that female sex (p=0.01) and low cardiac output syndrome (p<0.001) were associated with subxiphoid hernia formation. Conclusion: Female sex and postoperative low cardiac output syndrome were risk factors of subxiphoid hernia. Therefore, special attention is needed for patients with high-risk factors.

Suspected Intimal Sarcoma in the Abdominal Aorta -A case report- (복부 대동맥에 발생한 혈관 내막 육종 의증 - 1예 보고 -)

  • Choi, Eun-Seok;Kim, Kyung-Hwan;Choi, Jin-Ho;Lee, Jae-Hang;Hwang, Ho-Young;Kim, Ki-Bong
    • Journal of Chest Surgery
    • /
    • v.43 no.2
    • /
    • pp.204-207
    • /
    • 2010
  • A 68 year-old man visited our institution due to chest pain. Coronary angiography revealed triple vessel disease. A computed tomographic angiogram performed as a routine preoperative examination demonstrated an intraluminal spider-web-like mass from the infrarenal abdominal aorta to both common iliac arteries. The infrarenal aorta and both common iliac arteries were excised and replaced with concomitant off-pump coronary artery bypass grafts. Histologic examination of the aorta suggested an intimal sarcoma. A postoperative computed tomographic angiogram performed 3 months postoperatively showed no evidence of a residual or a recurred lesion.

Mechanism Diagnosis and Avoidance Design on Transient Acoustic Vibration of Reheater Water Supply Piping in Supercritical Boiler (초임계 보일러 재열기 급수 공급배관의 과도 음향진동 진단 및 회피설계)

  • Kim, Yeon-Whan;Bae, Yong-Chae;Kim, Jae-Won;Lee, Doo-Young;Heo, Hae-Yong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.5
    • /
    • pp.385-393
    • /
    • 2013
  • In this paper, the mechanism identification and the avoidance measures on the phenomena of transient acoustic vibration amplified at the water-supply piping system to regulate the steam temperature of the boiler reheater in 500MW class supercritical power plant are presented. The pressure pulsation waves induced by the impeller passing of two feed-water pumps with five blades are coincident with the local acoustic modes of boiler reheater water-supply piping system. There are the phenomena amplified at the peaks of 5X, 10X, 15X and 20X in spectrums of piping vibration, sound pressure, and the feed-water's pressure pulsation waves. The shut-off device is installed in the piping system for the interception of pressure pulsation waves transmitted from two feed-water pumps and the modified design change of the piping layout is applied for the acoustic resonance avoidance. The acoustic natural frequencies are separated from the harmonics of pressure pulsation waves induced by the pump impellers passing through the design change of the span length. The acoustic vibration is gone by resonance avoidance measures. As a result, more than 20 dBA reduction is achieved from 100 dBA to 80 dBA.

Abatement of CF4 Using RF Plasma with Annular Shape Electrodes Operating at Low Pressure (환상형상 전극구조를 갖는 저압 RF plasma를 이용한 CF4 제거)

  • Lee, Jae-Ok;Hur, Min;Kim, Kwan-Tae;Lee, Dae-Hoon;Song, Young-Hoon;Lee, Sang-Yun;Noh, Myung-Keun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.6
    • /
    • pp.690-696
    • /
    • 2010
  • Abatement of perfluorocompounds (PFCs) used in semiconductor and display industries has received an attention due to the increasingly stricter regulation on their emission. In order to meet this circumstance, we have developed a radio frequency (RF) driven plasma reactor with multiple annular shaped electrodes, characterized by an easy installment between a processing chamber and a vacuum pump. Abatement experiment has been performed with respect to $CF_4$, a representative PFCs widely used in the plasma etching process, by varying the power, $CF_4$ and $O_2$ flow rates, $CF_4$ concentration, and pressure. The influence of these variables on the $CF_4$ abatement was analyzed and discussed in terms of the destruction & removal efficiency (DRE), measured with a Fourier transform infrared (FTIR) spectrometer. The results revealed that DRE was enhanced with the increase in the discharge power and pressure, but dropped with the $CF_4$ flow rate and concentration. The addition of small quantity of $O_2$ lead to the improvement of DRE, which, however, leveled off and then decreased with $O_2$ flow rate.