• Title/Summary/Keyword: off-pump

Search Result 302, Processing Time 0.024 seconds

A Study on the Operating Characteristics of Solar Collecting System in Solar Thermal/Geothermal Hybrid System with Facade Integrated Solar Collector (Facade 일체형 태양열 집열기를 갖는 태양열/지열 하이브리드 시스템의 태양열 집열시스템 작동특성 연구)

  • Baek, Nam-Choon;Lee, Jin-Kook;Yu, Chang-Kyun;Yoon, Eung-Sang;Yoon, Jong-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.5
    • /
    • pp.69-76
    • /
    • 2010
  • In this study, the solar thermal and geo-source heat pump(GSHP) hybrid system for heating and cooling of Zero Energy Solar House(ZESH) was analyzed by experiment. The GSHP in this hybrid system works like as aback-up device for solar thermal system. This hybrid system was designed and installed for Zero Energy Solar House (KIER ZeSH) in Korea Institute of Energy Research. The purpose of this study is to find out that this system is optimized and operated normally for the heating load of ZeSH. The analysis was conducted as followings ; - the thermal performance of facade integrated solar collector - the on/off characteristics of solar system and GSHP - the contribution of solar thermal system. - the performance of solar thermal and ground source heat pump system respectively. - the meet of thermal load (space and water heating load). This experimental study could be useful for the optimization of this system as well as its application in house. This hybrid system could be commercialized for the green home if it is developed to a package type.

Improved Design in Fishing Operation System for Small Inshore and Coastal Fishing Vessels -II -Design of a Remote Steering System- (소형 연근해 어선의 조업 시스템 개선에 관한 연구-II -원격 조타 시스템의 설계-)

  • 이대재
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.36 no.1
    • /
    • pp.25-32
    • /
    • 2000
  • A combination steering system was designed to provide the flexibility in controlling the steering wheel in fishing operations of the inshore and coastal fishing vessels. The designed steering system basically is consisted of three driving units, such as a electrically driven hydraulic pump unit with a solenoid control valve, a DC motor driven hydraulic pump unit and a manually driven hydraulic pump unit, and two controllers to provide remote steering on the deck, respectively. The steering torque was measured and analyzed to investigate the dynamic performance of the developed steering system. The steering system showed excellent linearity between the working pressure of cylinder and the torque of rudder post in case of increasing in rudder angle from $5^{\circ} to 35^{\circ}$ that is, the steering torque increased from $10.4 kgf{\cdot}m$ to $105.3 kgf{\cdot}m$ and then the working pressure of cylinder fluctuated from 6.3 kgf/cm super(2) to 16.4 kgf/cm super(2). The steering time of 3.2 sec in remote hydraulic steering by the on/off solenoid valve control was much faster than 13.2 sec in the manual steering by the helmsman and 11.6 sec in the electric steering by a DC motor, and then it was verified that operation of one unit does not affect other units in combination steering system in any way. Furthermore, the developed steering system can be remotely controlled in multiple stations of the deck during the fishing operation and the automatic pilot steering unit can be used to add hydraulic steering.

  • PDF

Internal Flow Analysis of Seawater Cooling Pump using CFD (CFD를 이용한 해수냉각펌프의 내부유동 분석)

  • Bao, Ngoc Tran;Yang, Chang-jo;Kim, Bu-gi;Kim, Jun-ho
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.23 no.1
    • /
    • pp.104-111
    • /
    • 2017
  • This research focuses on simulation and visualization of flow field characteristics inside a centrifugal pump. The 3D numerical analysis was carried out by using a numerical CFD tool, addressing a Reynolds Average Navier-Stock code with a standard k-${\varepsilon}$ two-equation turbulence model. The simulation accounts for friction head loss due to rough walls at suction, impeller, discharge areas and volumetric head loss at impeller wear ring. A comparison of performance curves between simulation and experimentation is included, and it reveals a same trend of those results with a small difference of maximum 5 %. At best efficiency point, velocity vectors are smooth but it changes significantly under off-design point, a strong recirculation appears at the outlet of impeller passages near tongue area. A relatively uniform preassure distribution was observed around the impeller in despite of the tongue. Within the volute, because of its geometry, spiral vortexes formed, proving that the flow field in this region was relatively turbulent and unsteady.

Characteristics of Water Leakage from Cooling Components in a Storage Ring (방사광 차단용 진공부품의 냉각수 누설 특성)

  • Park, C.D.
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.1
    • /
    • pp.1-8
    • /
    • 2008
  • We analyzed the characteristics of water leakage from cooling components of the storage ring in the Pohang Light Source. The water leaks led localized pressure bumps and abnormal pressure changes. The leakage also changed the residual gas compositions depending not only on the position between leakage place to gas analyzer but also on on/off switching of ion pump and electron beam. We found that the residual gas analysis of $CH_4$, CO, NO was useful in determining water leaks.

A Lock-Time Improvement for an X-Band Frequency Synthesizer Using an Active Fast-Lock Loop Filter

  • Heo, Yun-Seong;Oh, Hyun-Seok;Jeong, Hae-Chang;Yeom, Kyung-Whan
    • Journal of electromagnetic engineering and science
    • /
    • v.11 no.2
    • /
    • pp.105-112
    • /
    • 2011
  • In phase-locked frequency synthesizers, a fast-lock technique is frequently employed to overcome the trade-off between a lock-time and a spurious response. The function of fast-lock in a conventional PLL (Phased Lock Loop) IC (Integrated Circuit) is limited by a factor of 16, which is usually implemented by a scaling of charge pumper, and consequently a lock time improvement of a factor of 4 is possible using the conventional PLL IC. In this paper, we propose a novel external active fast-lock loop filter. The proposed loop filter provides, conceptually, an unlimited scaling of charge pumper current, and can overcome conventional trade-off between lock-time and spur suppression. To demonstrate the validity of our proposed loop-filter, we fabricated an X-band frequency synthesizer using the proposed loop filter. The loop filter in the synthesizer is designed to have a loop bandwidth of 100 kHz in the fast-lock mode and a loop bandwidth of 5 kHz in the normal mode, which corresponds to a charge pumper current change ratio of 400. The X-band synthesizer shows successful performance of a lock-time of below 10 ${\mu}sec$ and reference spur suppression below -64 dBc.

Experimental Study on Hydrodynamic Performance and Wave Power Takeoff for Heaving Wave Energy Converter (수직 진자형 파력 발전 장치의 운동성능 및 파력 추출에 관한 실험적 연구)

  • Kim, Sung-Jae;Koo, WeonCheol;Min, Eun-Hong;Jang, Hoyun;Youn, Donghyup;Lee, Byeongseong
    • Journal of Ocean Engineering and Technology
    • /
    • v.30 no.5
    • /
    • pp.361-366
    • /
    • 2016
  • The aim of this study was to experimentally investigate the hydrodynamic performance of a hemispheric wave energy converter (WEC) and its wave power takeoff. The WEC is a heaving body-type point absorber with a hydraulic-pump power take-off (PTO) system. The hydraulic PTO system consists of a hydraulic cylinder, hydraulic motor, and generator, with consideration given to the hydraulic pressure and flow rate. Two body model shapes, including the original hemisphere and a bottom-chopped hemisphere, were considered. The heave RAOs of the two models were evaluated for various body drafts. The effects of the hydraulic PTO system on the RAOs were also investigated.

Clinical Results and Optimal Timing of OPCAB in Patients with Acute Myocardial Infarction (급성 심근경색증 환자에서 시행한 OPCAB의 수술시기와 검색의 정도에 따른 임상성적)

  • Youn Young-Nam;Yang Hong-Suk;Shim Yeon-Hee;Yoo Kyung-Jong
    • Journal of Chest Surgery
    • /
    • v.39 no.7 s.264
    • /
    • pp.534-543
    • /
    • 2006
  • Background: There are a lot of debates regarding the optimal timing of operation of acute myocardial infarction (AMI). Off pump coronary artery bypass grafting (OPCAB) has benefits by avoiding the adverse effects of the cardio-pulmonary bypass, but its efficacy in AMI has not been confirmed yet. The purpose of this study is to evaluate retrospectively early and mid-term results of OPCAB in patients with AMI according to transmurality and timing of operation. Material and Method: Data were collected in 126 AMI patients who underwent OPCAB between January 2002 and July 2005, Mean age of patients were 61.2 years. Male was 92 (73.0%) and female was 34 (27.2%). 106 patients (85.7%) had 3 vessel coronary artery disease or left main disease. Urgent or emergent operations were performed in 25 patients (19.8%). 72 patients (57.1%) had non-transmural myocardial infarction (group 1) and 52 patients (42.9%) had transmural myocardial infarction (group 2). The incidence of cardiogenic shock and insertion of intra-aortic balloon pump (IABP) was higher in group 2. The time between occurrence of AMI and operation was divided in 4 subgroups (<1 day, $1{\sim}3\;days,\;4{\sim}7\;days$, >8 days). OPCAB was performed a mean of $5.3{\pm}7.1$ days after AMI in total, which was $4.2{\pm}5.9$ days in group 1, and $6,6{\pm}8.3$ days in group 2. Result: Mean distal an-astomoses were 3.21 and postoperative IABP was inserted in 3 patients. There was 1 perioperative death in group 1 due to low cardiac output syndrome, but no perioperative new MI occurred in this study. There was no difference in postoperative major complication between two groups and according to the timing of operation. Mean follow-up time was 21.3 months ($4{\sim}42$ months). The 42 months actuarial survival rate was $94.9{\pm}2.4%$, which was $91.4{\pm}4.7%$ in group 1 and $98.0{\pm}2.0%$ in group 2 (p=0.26). The 42 months freedom rate from cardiac death was $97.6{\pm}1.4%$ which was $97.0{\pm}2.0%$ in group 1 and $98.0{\pm}2.0%$ in group 2 (p=0.74). The 42 months freedom rate from cardiac event was $95.4{\pm}2.0%$ which was $94.8{\pm}2.9%$ in group 1 and $95.9{\pm}2.9%$ in group 2 (p=0.89). Conclusion: OPCAB in AMI not only reduces morbidity but also favors hospital outcomes irrespective of timing of operation. The transmurality of myocardial infarction did not affect the surgical and midterm outcomes of OPCAB. Therefore, there may be no need to delay the surgical off-pump revascularization of the patients with AMI if surgical revascularization is indicated.

A Theoretical Study on Boil-off Gas Generated from Cooling Process for Cryogenic Components Using Liquid Hydrogen (액체 수소를 활용한 극저온 부품의 냉각 과정에서 발생하는 BOG에 관한 이론적 연구)

  • DONG WOO HA;HYUN WOO NOH;YOUNG MIN SEO;TAE HYUNG KOO;ROCK KIL KO
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.34 no.6
    • /
    • pp.615-622
    • /
    • 2023
  • In this study, the theoretical analysis focused on the quantity of liquid hydrogen required for cooling down to 20 K, as well as the generation of boil-off gas (BOG) from the cooling process of the cryogenic components. The study involved calculating the amount of liquid hydrogen needed to achieve the desired temperature for the cryogenic components and subsequently determining the resulting BOG production at various reference temperatures. It was shown that it was important to efficiently lower the temperature of cryogenic parts through preliminary cooling. As a result, the reference temperature and pressure had an influence on the BOG generation on the cooling of cryogenic components using liquid hydrogen.

Role of Intra-aortic Balloon Pump in High Risk Patients undergoing Off-Pump Coronary artery bypass graft (심폐바이패스 없이 시행하는 관상동맥 우회술시 고위험군 환자에서 대동맥내 풍선 펌프의 유용성)

  • Cho, Suk-Ki;Jang, Woo-Ik;Lim, Cheong;Lee, Cheul;Lee, Jae-Ik;Kim, Yong-Lak;Ham, Byung-Moon;Kim, Ki-Bong
    • Journal of Chest Surgery
    • /
    • v.34 no.12
    • /
    • pp.895-900
    • /
    • 2001
  • Background : This study aimed to evaluate the usefulness of preoperative placement of intraaortic balloon pump(IABP) in reducing operative risk and facilitating posterior vessel OPCAB in high risk patients with left main disease( 75% stenosis), intractable resting angina, postinfarction angina, or left ventricular dysfunction(ejection fraction 35%). Material and Method : One hundred eighty- nine consecutive patients who underwent multi-vessel OPCAB including posterior vessel revascularization were studied. The patients were divided into group I(n=74) that received preoperative or intraoperative IABP and group II(n=115) that did not receive IABP. In group I, there were 39 patients with left main disease, 40 patients with intractable resting angina, 14 patients with left ventricular dysfunction and 7 patients with postinfarction angina. Ten patients received intraoperative IABP support due to hemodynamic instability during OPCAB. Result : There was one operative mortality in group I and two mortalities in group II. The average number of distal anastomoses was not different between group I and group II(3.5$\pm$0.9 vs 3.4$\pm$0.9, p=ns). There were no significant differences in the number of posterior vessel anastomosis per patient between the two groups. There were no differences in ventilator support time, length of hospital stay, and morbidity between the two groups. There was one case of IABP-related complication in group I. Conclusion : IABP facilitates posterior vessel OPCAB in high risk patients, with comparable surgical results to low risk patients

  • PDF

Development of an Automated Measurement System for Dilution Process and Spraying Amount of Disinfectant

  • Kim, Jung-Chul;Chung, Sun-Ok;Cho, Byoung-Kwan;Chang, Hong-Hee;Kim, Suk;Chang, Dongil
    • Journal of Biosystems Engineering
    • /
    • v.38 no.4
    • /
    • pp.228-239
    • /
    • 2013
  • Purpose: The objectives of this study were to develop an automated disinfectant dilution system, and an automated data management system for spraying amount for resolving uncertainty problem. Methods: Proper diluting rate was made by a controlled volume pump for liquid disinfectant and a screw conveyer pump for solid disinfectant. The water capacity of disinfecting system of 400 L was controlled by two water level sensors. The water quantity of water tank was controlled by the signals which were produced by the water level sensors. Signals were processed by Labview Programming, and ON/OFF of solenoid valve that was used for controlling water supplying to water tank, was controlled by SSR. The operating time of pumps for disinfectant was controlled quantitatively. A turbine flowmeter was used for development of automated measurement system for spraying amount of disinfectant. In order to save the flowmeter data and to control the spraying system, a multi-function data logger was used, and it was processed and saved in Excel file by a program developed in this study. Results: Labview 2010 was used for programming to control the automated measurement system for spraying amount of disinfectant. Results showed that the relationship between flowmeter value and time had a significant linear relationship such as 0.99 of $R^2$. Generally, 6.74 L/s of diluted disinfectant is sprayed for a vehicle passing through the disinfection system (about 15 seconds). Test results showed that average error between the measured spraying amount and the flowmeter data was 50 mL, and the range of error was 1.3%. Since the amount and time of spraying could be saved in real-time by using the spreadsheet files which could not be modified arbitrarily, it made possible to judge objectively whether the disinfection spraying was performed or not. Test results of spraying liquid and solid disinfectant showed that the errors between the measured discharge rate and the theoretical one were ranged within 3-4% for various dilution rates. Conclusions: The disinfection system developed would be working accurately. The automated spraying data base management system satisfied the purpose of this study. The automated dilution process system developed in this study could discharge liquid and solid disinfectant with accurate dilution rate, relatively.