• Title/Summary/Keyword: off-gas

Search Result 898, Processing Time 0.031 seconds

Estimation of greenhouse gas (GHG) emission from wastewater treatment plants and effect of biogas reuse on GHG mitigation

  • Chang, Jin;Kyung, Daeseung;Lee, Woojin
    • Advances in environmental research
    • /
    • v.3 no.2
    • /
    • pp.173-183
    • /
    • 2014
  • A comprehensive mathematical model was developed for this study to estimate on-site and off-site GHG emissions from wastewater treatment plants (WWTPs). The model was applied to three different hybrid WWTPs (S-WWTP, J-WWTP, and T-WWTP) including anaerobic, anoxic, and aerobic process, located in Seoul City, South Korea. Overall on-site and off-site GHG emissions from S-WWTP, J-WWTP, and T-WWTP were $305,253kgCO_2e/d$, $282,682kgCO_2e/d$, and $117,942kgCO_2e/d$, respectively. WWTP treating higher amounts of wastewater produced more on-site and off-site GHG emissions. On average, the percentage contribution of on-site and off-site emissions was 3.03% and 96.97%. The highest amount of on-site GHG emissions was generated from anoxic process and the primary on-site GHG was nitrous oxide ($N_2O$). Off-site GHG emissions related to electricity consumption for unit operation was much higher than that related to production of chemicals for on-site usage. Recovery and reuse of biogas significantly reduced the total GHG emissions from WWTPs. The results obtained from this study can provide basic knowledge to understand the source and amount of GHG emissions from WWTPs and strategies to establish lower GHG emitting WWTPs.

On/Off-Design/Transient Analysis of a 50KW Turbogenerator Gas Turbine Engine (50KW 터보제너레이터용 가스터빈 엔진의 설계점/ 탈설계/과도성능해석)

  • Kim, Su-Yong;Park, Mu-Ryong;Jo, Su-Yong
    • 연구논문집
    • /
    • s.27
    • /
    • pp.87-99
    • /
    • 1997
  • Present paper describes on/off design performance of a 50KW turbogenerator gas turbine engine for hybrid vehicle application. For optimum design point selection, relevant parameter study is carried out. The turbogenerator gas turbine engine for a hybrid vehicle is expected to be designed for maximum fuel economy, ultra low emissions, and very low cost. Compressor, combustor, turbine, and permanent-magnet generator will be mounted on a single high speed (82,000 rpm) shaft that will be supported on air bearings. As the generator is built into the shaft, gearbox and other moving parts become unnecessary and thus will increase the system's reliability and reduce the manufacturing cost. The engine has a radial compressor and turbine with design point pressure ratio of 4.0. This pressure ratio was set based on calculation of specific fuel consumption and specific power variation with pressure ratio. For the given turbine inlet temperature, a rather conservative value of $1100^\circK$ was selected. Designed mass flow rate was 0.5 kg/sec. Parametric study of the cycle indicates that specific work and efficiency increase at a given pressure ratio and turbine inlet temperature. Off design analysis shows that the gas turbine system reaches self operating condition at N/$N_{DP}$ = 0.53. Bleeding air for turbine stator cooling is omitted considering low TIT and for a simple geometric structure. Various engine performance simulations including, ambient temperature influence, surging at part load condition. Transient analysis were performed to secure the optimum engine operating characteristics. Surge margin throughout the performance analysis were maintained to be over 80% approximately. Validation of present results are yet to be seen as the performance tests are scheduled by the end of 1998 for comparison.

  • PDF

Development and Performance Test of Gas Safety Management System based on the Ubiquitous Home (u-home 가스안전관리시스템 개발 및 성능시험)

  • Park, Gyou-Tae;Lyu, Geun-Jun;Kim, Young-Gyu;Kim, Yeong-Dae;Jee, Cha-Wan;Kwon, Jong-Won;Kim, Hie-Sik
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.3
    • /
    • pp.13-20
    • /
    • 2011
  • In this paper, we proposed a system to raise gas safety management by using the wireless communication module and intelligent gas safety appliances. Our designed systems configure a micom-gas meter, an automatic extinguisher, sensors, and a wallpad. A micom-gas-meter monitors gas flow, gas pressure, and earthquake. An automatic fire extinguisher checks gas(combustible) leaks and temperature of $100^{\circ}C$ and $130^{\circ}C$. Sensors measure smoke and CO gas. In our novel system, a micom-gas meter cut off inner valve with warnings, an automatic fire extinguisher cut off middle valve and spray extinguishing materials, and sensors generate signals for smoke and CO when occurring gas risk. Gas safety appliances and sensors takes safety measures, and transmit those signal to a wallpad. The wallpad again transmit signal like events to a control server. Users can connect web pages for gas safety through B-ISDN and control and manage them. We hereby devised scenarios for gas safety and risk management, and demonstrated their effectiveness through experiments.

A Study on the Characteristics of Nanodiamond Films with the Gas Flow Control (가스 유량제어에 의한 나노다이아몬드 박막의 특성연구)

  • Kim, Tae-Gyu;Kim, Chang-Hoon
    • Journal of the Korean institute of surface engineering
    • /
    • v.39 no.4
    • /
    • pp.153-159
    • /
    • 2006
  • Nanodiamond films were deposited on Si substrate by introducing a time dependent on/off modulation of $CH_4\;and\;O_2$ flows in a vertical-type microwave plasma enhanced chemical vapor deposition system. Surface morphology and diamond quality of the film were investigated as a function of the on/off modulation time interval. The diamond nucleation density on the substrate was enhanced under low temperature and low pressure condition. In addition, the diamond nucleation density was enhanced by increasing the on/off modulation time interval. Enhanced diamond quality was noticeable under the condition of a longer on/off modulation time interval. It was suggested that the nanodiamond nuclei formed the cluster formation.

Experiment Study on Operation Model of Automatic Cylinder Valve by the Temperature Differences (온도차 변동에 따른 전자밸브 작동모델 실험적 연구)

  • Jang, Kap-Man;Eom, Seok Hwa;Kim, In Chan;Kim, Chung Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.6
    • /
    • pp.73-79
    • /
    • 2012
  • Currently, all domestic CNG vehicles have manual cylinder valves installed. These are inconvenient for drivers in case of a gas leak accident, because drivers have to stop the vehicle operation and manually close the valve. It makes difficult condition for drivers to quickly and properly respond to such accidents. In advanced European countries, they require Automatic cylinder valve installation, which has a structure where the valve is automatically shut off when the driver turns off the ignition in case of a gas leak. If this electric valve system is introduced in Korea, the safety of CNG buses will be improved with better functionalities. In this paper, in order to solve the structural problem of difficulty for a driver to identify the operational status of individual Automatic cylinder valves, an approach was made regarding temperature increase with pressure increase during CNG filling. it was estimated that the temperature increased approximately more than $30^{\circ}C$ due to pressure difference during the filling. Therefore, it was concluded from the experimental data that the valve of the container whose temperature did not increase did not operate, resulting in filling failure.

A Developing Tendency of Liquefied Natural Gas Carriers (액화천연가스 운반선(LNGC)의 발전 추세)

  • Lee, Dong-Sup
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.15 no.3
    • /
    • pp.269-274
    • /
    • 2009
  • Recently, the construction of Liquefied Natural Gas Carriers(LNGC) is being promoted larger and larger depending on long voyage. In 1950 years, $5,000m^3$ class of LNGC had been changed to $71,500m^3$ class in 1973. and to $210,000-266,000m^3$ class in 2007. Especially, the system of main engines and cargo control, Re-liquefaction of natural gases have become possible in LNGC. This research deals with the LNG projects, world markets of energy and developing tendency of liquefied natural gas carriers.

  • PDF

The Ejector Design and Test for 5kW Molten Carbonate Fuel Cell (75kW 용융탄산염 연료전지 시스템의 MBOP 개발)

  • Kim, Beom-Joo;Kim, Do-Hyung;Lee, Jung-Hyun;Kang, Seung-Won;Lim, Hee-Chun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.353-356
    • /
    • 2009
  • A pivotal mechanical balance of plant for 75kW class molten carbonate fuel cells comprise of a catalytic burner and an ejector which has been designed and tested in KEPRI(Korea Electric Power Research Institute). The catalytic burner, which oxidizes residual fuel in the anode tail gas, was operated at several conditions. Some problems arose due to local overheating or auto-ignition, which could limit the catalyst life. The catalytic burner was designed by considering both gas mixing and gas velocity. Test results showed that the temperature distribution is very uniform. In addition, an ejector is a fluid machinery to be utilized for mixing fluids, maintaining vacuum, and transporting them. The ejector is placed at mixing point between the anode off gas and the cathode off gas or the fresh air Several ejectors were designed and tested to form a suction on the fuel tail gas and balance the differential pressures between anode and cathode over a range of operating conditions. The tests showed that the design of the nozzle and throat played an important role in balancing the anode tail and cathode inlet gas pressures. The 75kW MCFC system built in our ejector and catalytic burner was successfully operated from Novembe, 2008 to April, 2009. It recorded the voltage of 104V at the current of 754A and reached the maximum generating power of 78.5kW DC. The results for both stand-alone and integration into another balance of plant are discussed.

  • PDF

충돌형 가스발생기 탈설계점 연소시험

  • Kim, Seung-Han;Han, Yeung-Min;Seo, Seong-Hyeon;Moon, Il-Yoon;Lee, Kwang-Jin;Kim, Jong-Kyu;Seol, Woo-Seok
    • Aerospace Engineering and Technology
    • /
    • v.3 no.2
    • /
    • pp.81-90
    • /
    • 2004
  • This paper describes the results of combustion performance test of fuel-rich gas generator(GG) using LOx and kerosene as propellant at off-design conditions. The chamber pressure is thought to be a function of O/F ratio and total propellant mass flow rate. The test shows that the spatial temperature deviation at the exit of gas generator remains within 7.5K and that the average gas temperature at the exit is a function of propellant O/F ratio. The results of firing test of gas generator at off-design conditions, especially the relation between gas temperature and O/F ratio, can provide useful data for the design of future gas generator and for the development of low-O/F ratio reaction analysis code.

  • PDF

Numerical Study of Heat Flux and BOG in C-Type Liquefied Hydrogen Tank under Sloshing Excitation at the Saturated State (포화상태에 놓인 C-Type 액체수소 탱크의 슬로싱이 열 유속과 BOG에 미치는 변화의 수치적 분석)

  • Lee, Jin-Ho;Hwang, Se-Yun;Lee, Sung-Je;Lee, Jang Hyun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.35 no.5
    • /
    • pp.299-308
    • /
    • 2022
  • This study was conducted to predict the tendency for heat exchange and boil-off gas (BOG) in a liquefied hydrogen tank under sloshing excitation. First, athe fluid domain excited by sloshing was modeled using a multiphase-thermal flow domain in which liquid hydrogen and hydrogen gas are in the saturated state. Both the the volume of fluid (VOF) and Eulerian-based multi-phase flow methods were applied to validate the accuracy of the pressure prediction. Second, it was indirectly shown that the fluid velocity prediction could be accurate by comparing the free surface and impact pressure from the computational fluid dynamics with those from the experimental results. Thereafter, the heat ingress from the external convective heat flux was reflected on the outer surfaces of the hydrogen tank. Eulerian-based multiphase-heat flow analysis was performed for a two-dimensional Type-C cylindrical hydrogen tank under rotational sloshing motion, and an inflation technique was applied to transform the fluid domain into a computational grid model. The heat exchange and heat flux in the hydrogen liquid-gas mixture were calculated throughout the analysis,, whereas the mass transfer and vaporization models were excluded to account for the pure heat exchange between the liquid and gas in the saturated state. In addition, forced convective heat transfer by sloshing on the inner wall of the tank was not reflected so that the heat exchange in the multiphase flow of liquid and gas could only be considered. Finally, the effect of sloshing on the amount of heat exchange between liquid and gas hydrogen was discussed. Considering the heat ingress into liquid hydrogen according to the presence/absence of a sloshing excitation, the amount of heat flux and BOG were discussed for each filling ratio.

A Comparative Study Between On-Pump and Off-Pump Coronary Artery Bypass Grafting on Clinical Outcomes

  • Moon Seong-Min;Choi Seok-Cheol
    • Biomedical Science Letters
    • /
    • v.10 no.3
    • /
    • pp.237-243
    • /
    • 2004
  • In recent, many cardiac centers have preferred off-pump coronary artery bypass grafting (CABG) to on-pump CABG to prevent the adverse effects of cardiopulmonary bypass. The present study was performed to prove beneficial effects of off-pump CABG. Sixty adult patients scheduled for elective CABG were randomly assigned to On-pump group (n=30) or Off-pump group (n=30). Arterial blood samples were drawn before and after the operation (Pre-OP and Post-OP, respectively) for measuring CBC, prothrombin time, activated thromboplastine time, blood gas analysis, creatine kinase-MB (CK-MB) level, and lactate dehydrogenase (LDH) level. Perioperative parameters including heparin and protamine usages, complications, blood components usages, blood loss, ventilation and ICU-staying time, and hospitalization were also evaluated. Platelet count at Post-OP was high in Off-pump group whereas CK-MB and LDH levels were low compared with On-pump group. Off-pump group had significantly lower heparin and protamine usages, lower total leukocyte count, higher hematocrit and hemoglobin levels, less blood loss, lower usages of blood components, shorter ventilation and ICU-staying time, and lower incidence of pleural effusion than On-pump group. Other variables did not significantly differ between two groups. These results showed that Off-pump CABG was a satisfactory technique with less inflammatory reaction, less cardiac damage, less postoperative complications, and less cost.

  • PDF