• Title/Summary/Keyword: off-angle

Search Result 692, Processing Time 0.025 seconds

A Study on Rotor Position Detection and Securing Initial Position for Switched Reluctance Motor (SRM) (스위치드 릴럭턴스 전동기 (SRM) 회전자 위치 검출 및 초기 위치확보 연구)

  • Jeong, Sungin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.3
    • /
    • pp.141-146
    • /
    • 2020
  • In brushless DC motors (BLDC), the on/off angle of the switch is determined by the optimal alignment of the stator and rotor, while switched reluctance motors (SRM) are complex parameters with many on/off angles of the switch. It appears as a function and therefore the switching angle is variable for optimal operation. Therefore, in order to operate the switched reluctance motor (SRM) optimally, the rotor position can be detected using a high resolution position sensor and a complicated additional circuit. In this paper, rotor position detection and related position detection circuits are applied and detected by using various sensors such as encoder, hall sensor and opto interrupter among several methods to drive switched reluctance motor (SRM). Also a study on securing the initial position of the rotor was conducted.

A Study on the Strength Evaluation of Unidirectional Carbon Fiber Reinforced Plastics by Nondestructive Method (일방성(一方性) 복함재료(複合材料)의 파괴거동(破壞擧動) 및 강도평가(强度評價)에 관(關)한 연구(硏究))

  • Chang, H.K.;Lee, J.S.;Cho, K.S.;Lee, S.H.;Park, E.S.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.7 no.2
    • /
    • pp.42-47
    • /
    • 1988
  • The off-axis tensile strength of the unidirectional carbon fiber reinforced plastic and the residual strength of impact damaged CFRP were measured and compared with the stress wave factor (SWF) of the specimens. The SWF values were measured to be decreased with the strength reduction in both cases and found to be useful for the nondestructive strength evaluation of unidirectional CFRP. The failure behaviour of the unidirectional CFRP during off-axis tensile testing was also monitored by acoustic emission(AE) method. The AE energy release showed the characteristic feature depending on the off-axis angle and this result was analyzed to be caused by the difference of the expected failure mode depending on the off-axis angle. The failure mode of CFRP was found to be analyzed by investigation of the peak amplitude distribution of AE.

  • PDF

Effect of Chest Compression Position Depending on the Rescuer's Hip Joint Angle During Basic CPR (심폐소생술 수행자의 엉덩관절 각도가 심폐소생술 결과에 미치는 영향)

  • Lee, Jae-Min;Yun, Hyeong-Wan
    • Fire Science and Engineering
    • /
    • v.34 no.2
    • /
    • pp.103-109
    • /
    • 2020
  • This study aims to investigate the improvement in basic CPR quality on the basis of the hip joint angle of the rescuer among students in the Department of Emergency Medical Technology who completed a basic CPR curriculum. In this study, we carried out a comparative analysis using SimPad SkillReporter and Resusci Anne® QCPR® to measure the quality of CPR (depth of chest compressions, full relaxation, compression speed, and more) on the basis of the rescuer's hip joint angle in accordance with the 2015 AHA Guidelines and conducted chest compressions and CPR 5 times in a 30:2 ratio. It was found that maintenance of the rescuer's hip joint angle at 90 degrees while compressing and relaxing the chest made a statistically significant difference in both the experimental and control groups. Moreover, this indicated that the closer the hip joint angle was to 90 degrees, the better was the quality of basic CPR. However, there was no significant difference in the hip joint angle, degree of CPR, depth of chest compressions, chest compression speed, chest compression and relaxation percentages (%), accuracy of chest compressions, hands-off time during CPR, and percentage of chest compression time (p > 0.05). Maintaining the hip joint angle at 90 degrees for basic CPR was not significantly different from not maintaining this angle. Nonetheless, good results have been obtained at moderate depth and 100% recoil. Therefore, good outcome and high-quality CPR are expected.

Performance comparison of MIMO-VLC systems according to the change of an emission angle (발광 각도 변화에 따른 MIMO-VLC 시스템의 성능 비교)

  • Lee, Byung-Jin;Kim, Yong-Won;Kim, Young-Keun;Kim, Kyung-Seok
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.2
    • /
    • pp.73-79
    • /
    • 2014
  • Visible light communication is a communication method using an LED having a high-speed ON / OFF rate data to be transmitted, it is used as a wireless high speed data transmission. VLC system evolves, the problem of basic research is intended to improve performance and ensure reliability of the communication. The nature of the visible light communication, communication is performed only in the reach of the light, which indicates a big difference by the emission angle of the light. Therefore, in this paper, in the case of indoor environments generally, with the attributes of the multiple LED is equipped, was applied to a MIMO (Multiple Input Multiple Output) communication system. and analyzed SNR performance and total power can be obtained on the reception side by changing the emission angle of the transmitter. As a result of the simulation was run against this, it was confirmed that there is a significant impact on the performance of BER and SNR performance by the emission angle of the transmitter.

Operative Treatment of Intraarticular Calcaneal Fractures using Extensile Lateral Approach (광범위 외측 도달법을 이용한 관절내 종골 골절의 수술적 치료)

  • Chung, Hyung-Jin;Ahn, Jong-Kuk;Bae, Su-Young;Jung, Hoon
    • Journal of Korean Foot and Ankle Society
    • /
    • v.13 no.1
    • /
    • pp.60-67
    • /
    • 2009
  • Purpose: This study was designed to investigate the usefulness of extensile lateral approach for accurate reduction and rigid internal fixation in comminuted intraarticular fractures of calcaneus. Materials and Methods: From October 2002 to May 2007, we managed 55 patients (62 cases) with open reduction and internal fixation using extensile lateral approach. Among these, 38 patients (43 cases) who underwent preoperative and postoperative CT scan were enrolled. All patients were evaluated over 24 months after surgery. Bohler angle and Gissane angle on plain X-ray, displacement and step-off of articular surface of calcaneus on CT scan were measured and we compared the difference between preoperative and postoperative value of them. Clinical results were assessed by using AOFAS Ankle-Hindfoot Scale. Results: The average Bohler angle was restored from $6.8^{\circ}$ to $23.5^{\circ}$ and Gissane angle was improved from $116.4^{\circ}$ to $113.5^{\circ}$ after operation. The average distance of displacement was restored from 4.2 mm to 1.4 mm and step-off of articular surface was recovered from 5.1 mm to 1.3 mm. Clinical results were excellent in 17 cases, good in 18 cases, fair in 3 cases, and poor in 5 cases. 10 cases developed postoperative complications such as skin necrosis, heel pain, limitation of motion of ankle and subtalar arthritis. Conclusion: The extensile lateral approach is valuable for the comminuted intraarticular fractures of calcaneus that enables accurate anatomical reduction and rigid internal fixation by providing direct exposure of subtalar joint.

  • PDF

Convergence Comparison of the Angle Change of Ankle Joint while Walking according to the Heel height of Insole Shoes in 20s males with Flatfoot (평발을 가진 20대 남성이 인솔구두의 굽 높이에 따른 보행 시 발목관절의 각도변화에 대한 융복합적 비교)

  • Seo, Kyo-Chul;Park, Seung-Hwan;Kim, Hyen-Ae
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.12
    • /
    • pp.117-123
    • /
    • 2021
  • The purpose of this study is to convergence comparison the ankle joint angle change during walking of college students in their 20s with flat foot according to the heel height of insole shoes. Qualisys Track Manager Software ver. 2.8 (Qalisys Track Manager) was used for 15 college students. Functional shoes with insoles were manufactured, and the heel heights of the shoes were set to 3cm and 7cm. The subjects wore shoes with two high heels and gaited by attaching a reflex marker to the side of the ankle joint. The angle change of the ankle joint was measured in the gait stance phase. The angle of the ankle joint significantly decreased both heel strike, foot flat, midstance, and toe off to the heel height increased when the subjects with flat feet wore insole shoes. Therefore, it is thought that flat feet should wear low shoes when wearing insoles to reduce the fatigue of the soles and to walk comfortably.

Estimation of Tibia Angle through Time-Varying Complementary Filtering and Gait Phase Detection (시변 상보필터와 보행상태 추정을 이용한 경골의 기울어짐 각도추정)

  • Song, Seok-ki;Woo, Hanseung;Kong, Kyoungchul
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.10
    • /
    • pp.944-950
    • /
    • 2015
  • Recent studies on ankle-foot prostheses used for transtibial amputees have focused on the adaptation of the ankle angle of the prosthesis according to ground conditions. For adaptation to various ground conditions (e.g., incline, decline, and step conditions), ankle-foot prostheses should first recognize the ground conditions as well as the current human motion pattern. For this purpose, the ground reaction forces and orientation angle of the tibia provide fundamental information. The measurement of the orientation angle, however, creates a challenge in practice. Although various sensors, such as accelerometers and gyroscopes, can be utilized to measure the orientation angles of the prosthesis, none of these sensors can be solely used due to their intrinsic drawbacks. In this paper, a time-varying complementary filtering (TVCF) method is proposed to incorporate the measurements from an accelerometer and a gyroscope to obtain a precise orientation angle. The cut-off frequency of TVCF is adaptively determined according to the human gait phase detected by a fuzzy logic algorithm. The performance of the proposed method is verified through experiments.

Effect of Incidence Angle on Turbine Blade Heat Transfer Characteristics (II) - Blade Surface - (입사각 변화에 따른 터빈 블레이드에서의 열전달 특성 변화 (II) - 블레이드 표면 -)

  • Rhee, Dong-Ho;Cho, Hyung-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.4
    • /
    • pp.357-366
    • /
    • 2007
  • The present study investigated local heat/mass transfer characteristics on the surface of the rotating turbine blade with various incidence angles. The experiments are conducted in a low speed annular cascade with a single stage turbine. The blade has a flat tip with the mean tip clearance of 2.5% of the blade chord. A naphthalene sublimation method is used to measure detailed mass transfer coefficient on the blade. At design condition, the inlet Reynolds number is $Re_c=1.5{\times}10^5$ which results in the blade rotation speed of 255.8 rpm. Also, the effect of off-design condition is examined with various incidence angles between $-15^{\circ}$ and $+7{\circ}$. The results indicated that the incidence angle has significant effects on the blade surface heat transfer. In mid-span region, the laminar separation region on the pressure side is reduced and the laminar flow region on the suction side shrinks with increasing incidence angle. Near the tip, the effect of tip leakage flow increases in span wise and axial directions as the incidence angle decreases because the tip leakage flow is formed near the suction side surface. However, the effect of tip leakage flow is reduced with positive incidence angle.

Unsteady Transitional Boundary Layer due to Rotor Stator Interaction at Design and Off Design Operations (설계점 및 탈설계점에서의 rotor-stator 상호작용에 의한 비정상 천이 경계층의 수치해석적 연구)

  • Kang Dong Jin;Jun Hyun Joo
    • Journal of computational fluids engineering
    • /
    • v.4 no.2
    • /
    • pp.17-30
    • /
    • 1999
  • The unsteady transitional boundary layer due to rotor-stator interaction was studied at two operation points, the design and one off design points. The off design point leads to lower blade loading and lower Reynolds number. A Navier-Stokes code developed in the previous study was parallelized to expedite computations. A low Reynolds number turbulence model was used to close the momentum equations. All computations show good agreement with experimental data. The wake induced transitional strip on the suction side of the stator is clearly captured at design point operation. There is no noticeable change in shape and phase angle of the wake induced strip even in the laminar sublayer. The wake induced transitional strip at off design point shows more complex structure. The wake induced transitional strip is observed only in the turbulent layer, and becomes obscure in the laminar sublayer and buffer layer. This behavior is probably consequent upon that the transition is governed by both wake induced strip and natural transition mechanism by Tollmien-Schlichting wave.

  • PDF

IR Cut-off Filter Made of CeO2 and SiO2 Thin Films Coated on PMMA Substrate (PMMA 기판에 CeO2와 SiO2를 코팅하여 제작한 적외선 차단필터)

  • Yu, Yeon-Serk;Choi, Sang-Serk
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.5
    • /
    • pp.480-486
    • /
    • 2006
  • Generally, IR cut-off filters for mobile phone is coated on the glass substrate at high temperature(above $300^{\circ}C$). In this work, we prepared IR cut-off filters on the poly(methyl methacrylate)(PMMA) substrates at low temperature(about $70^{\circ}C$ ). using the $CeO_2\;and\;SiO_2$ coatings by physical vapor deposition. The surface energies of coated and uncoated PMMA, and adhesive properties of IR cut-off filters coatings were examined using contact angle measurements. We demonstrate the improve of mobile phone optical system using these results.