Adsorption-DAF Hybrid Process for the Simultaneous Removal of Algae and Organic Compounds (조류와 유기화합물의 동시제거를 위한 흡착 - DAF 복합공정)

  • Lee, Jae-Wook;Kwak, Dong-Heui;Choi, Seung-Phil;Jung, Heung-Joe
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.2
    • /
    • pp.208-214
    • /
    • 2004
  • Dissolved air flotation (DAF) is an effective solid/liquid separation process for low density floc particles such as algal, color-alum and clay-alum flocs produced from low turbidity water. The removal of taste and odor-causing organics (2-mthylisoboneol and geosmin) originating from algae in drinking water is a local and worldwide concern. Although DAF has been effectively applied for the removal of suspended solid, its application for the treatment of dissolved organic carbon is very limited. In this study, a new hybrid system consisting of adsorption and DAF processes was introduced for the simultaneous removal of algae and taste and odor-causing organics. Powdered activated carbon (PAC) was used as an adsorbent. In this proposed system, the major concern of eliminating the spent PAC from the system was also addressed. It was found that zeta potential of algae and PAC was increased with coagulant dosage, and the removal efficiency in DAF was also enhanced up to 90~95% under the given experimental conditions. Based on this study, the hybrid process was found to be a promising technology for the simultaneous removal of algae and dissolved organic pollutants.

Odor Removal by Using Compost and Granular Scrap Tires (퇴비 및 폐타이어 Granule을 이용한 악취 제거)

  • Chung, Yoon-Jin
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.13 no.1
    • /
    • pp.43-50
    • /
    • 1999
  • In spite of low energy requirement, and operation and construction cost, biofilters with soil beds have not been operated efficiently. Because of excess moisture in winter and rainy periods, saturated pores in the bed prevent passage and sorption of odorous compounds. Sometimes this results in septic conditions that release previously sorbed and oxidized sulfur. Therefore, an economical and effective alternative needs to be developed. The objectives of this study were to confirm applicability of the granular scrap tires with compost for treating odorous gas as well as to obtain optimum design parameters for proposed system. In lab-scaled test, multiple stage reactors had lower headloss than a single stage reactor and less headloss was occurred for the gas with higher moisture content. For practical purpose, pilot-scaled reactor was operated to remove odor from septic tank, manure and animal wastewater treatment plant and composting machine. According to the results of pilot scaled test, $H_2S$ can be always removed completely and ammonia/amine can be removed excellently when proper moisture content is provided. The results from lab and pilot test showed that granular scrap tire could be replaced with soil as supporting material for biofilter showed excellent drainage because of its ability to reject moisture.

  • PDF

Overview of the Formation, Components, Color, and Abnormal Findings of Urine (소변의 생성, 구성성분, 색깔, 그리고 이상소견)

  • Park, Se Jin;Shin, Jae Il
    • Childhood Kidney Diseases
    • /
    • v.17 no.2
    • /
    • pp.29-34
    • /
    • 2013
  • Urine production is vital for the removal of certain waste products produced by metabolism in the body and for the maintenance of homeostasis in the body. The kidneys produce urine by the following three precisely regulated processes: filtration, reabsorption, and secretion. Urine is composed of water, certain electrolytes, and various waste products that are filtered out of the blood through the glomeruli. The physical features of urine are evaluated carefully to detect any abnormal findings that may indicate underlying diseases in the genitourinary system. A change in urine color may indicate an underlying pathological condition, although many of the causes of abnormal urine color are benign effects of medications and foods. A characteristic and specific odor may be the result of a metabolic disease rather than a concentrated specimen or a simple urinary tract infection. Although transient changes in urine output and nocturia are usually benign conditions, persistent abnormal findings require further workup, with a thorough medical history taking. This article presents many of the conditions that physicians may encounter and will help them in the diagnosis and in establishing a treatment plan.

Efficiency Characteristics by Mixed Absorbents for the Removal of Odor Compounds in the Wet Scrubber (습식세정탑 내 악취가스 제거를 위한 복합흡수제의 효율 특성)

  • Park, Young G.;Kim, Jeong-in
    • Applied Chemistry for Engineering
    • /
    • v.22 no.1
    • /
    • pp.48-55
    • /
    • 2011
  • It was found that the absorbent mixed with 2-aminoethanol and others has been applied to remove them via chemical neutralization. The absorbent of natural second metabolites was achieved by a removal efficiency of 20~30% by itself depending on treatment conditions, but the complex absorbent mixed with 0.2% amine chemical provides the removal efficiency of over 98%. Optimal removal efficiencies have been examined against two major parameters of the temperature and pH to remove ammonia and hydrogen sulfide gases. The chemical analysis was also performed to analyze the composition of an essential oil by GC-MS. The monoterpenes in an essential oil reacted with odorous compounds by neutralization and their reaction mechanism was partially elucidated.

Ammonia neutralization and removal using electrolyzed-acidic water (전해산성수를 이용한 암모니아 중화와 제거)

  • Choi, Weon-Kyung
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.5
    • /
    • pp.185-190
    • /
    • 2021
  • An electrolyzed-acidic water treatment was investigated as a methods for removing ammonia, which is a cause of odor in life environment. The prepared electrolyzed-acidic water was found out as stable solvent capable of neutralizing weak alkaline ammonia by measuring changes in pH and ORP. It was found out that ammonia was removed from the mixture solution of electrolyzed-acidic water and ammonia water by the UV-vis absorbance analysis and electrochemical open-circuit potential measurement. The neutralized ammonia by electrolyzed-acidic water and effectively removed odor was measured using ammonia gas detecter. Consequently, we recommend the electrolyzed-acidic water can effectively and safely remove ammonia in eco-friendly.

A Study on Architectural Form of Waste to Energy Plants in accordance with Law - Focus on Seoul and Tokyo - (법규에 따른 자원회수시설의 건축적 형태에 관한 연구 - 서울과 도쿄를 중심으로 -)

  • Jung, Seung-won;Lee, Kang-jun
    • Journal of Urban Science
    • /
    • v.11 no.1
    • /
    • pp.29-35
    • /
    • 2022
  • Waste to Energy Plant were recognized as hateful facilities, and there were many conflicts in the location due to social problems such as the NIMBY phenomenon due to problems such as damage to property in the surrounding area, odor, and image loss. Problems such as air pollution and odor are solved by the development of advanced prevention facilities such as electric dust collectors, wet cleaning systems, semi-dry reaction towers, bag filters, and catalyst towers (SCR: Selective Catalytic Reduction), and air recycling facilities in waste storage tanks. However, it is being avoided because of the perception that it is an incinerator. To resolve these conflicts, the government installs and operates resident convenience facilities to compensate residents near resource recovery facilities, provides green space and improves the environment, and supports heating expenses in accordance with the 「Waste Treatment Facility Support Act」. The purpose of this study is to derive implications through the analysis of domestic and overseas case studies for resident convenience facilities and environment improvement for the promotion of local communities in resource recovery facilities and use them as basic data for community promotion and environmental improvement when installing resource recovery facilities in the future.

The results of meat quality traits and sensory characteristics according to the concentration of androstenone in uncastrated pigs

  • Shah Ahmed Belal;Jong-Hyun Jung
    • Journal of Animal Science and Technology
    • /
    • v.66 no.2
    • /
    • pp.387-397
    • /
    • 2024
  • Pork quality is determined by several attributes, among which odor and taste are the utmost significant. Therefore, this study was aimed to assess the effects of boar odor hormone concentration on the quality traits and sensory acceptability of pork. A total twenty-six (26) non-castrated 3-way crossbred (Landrace × Yorkshire × Duroc) pigs were selected with an average body weight (ABW) 115.6 kg before to slaughter. The three treatment groups (low, medium and high) were divided according to the androstenone concentration. In experiment 1, for meat quality traits carcass was selected based on androstenone concentration: low (LC, 0.64-0.69 ㎍/g, n = 9), medium (MC, 0.70-0.99 ㎍/g, n = 7) and high (HC, 1.00-1.69 ㎍/g, n = 10). In experiment 2, for sensory evaluation carcasses were also selected based on the abovementioned conditions. Results revealed that androstenone concentration not effect on proximate components, meat quality traits and fatty acids except palmitoleic acid. Sensory evaluation data showed that boar taint and meat boar taint were significantly increased in a concentration-dependent manner from low to high, whereas, gravy and meat flavor preference were significantly increased in LC group than HC group. In addition, correlation analysis showed that boar taint and meat boar taint were positively, and gravy and meat flavor preference were negatively correlated with boar taint hormones. In essence, our findings indicate that androstenone concentration had no effect on meat qualities, but a high concentration of androstenone had a negative effect on the sensory characteristics in uncastrated pigs.

Effect of raw water quality decrease on water treatment costs (상수원수 수질저하가 정수처리 비용에 미치는 영향)

  • Kim, Jinkeun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.4
    • /
    • pp.239-250
    • /
    • 2020
  • In this study, effects of five raw water quality parameters (turbidity, odor compounds caused by algae, filter clogging caused by algae, pH increase caused by algae, and organic matter) on improvements and operations costs of typical water treatment plant (WTP) were estimated. The raw water quality parameters were assumed the worst possible conditions based on the past data and costs were subsequently estimated. Results showed that new water treatment facilities were needed, such as a selective intake system, an advanced water treatment processes, a dual media filter, a carbonation facility, and a re-chlorination facility depending on water quality. Furthermore, changes needed to be made in WTP operations, such as adding powered activated carbon, increasing the injection of chlorine, adding coagulation aid, increasing the discharge of backwashed water, and increasing the operation time of dewatering facilities. Such findings showed that to reliably produce high-quality tap water and reduce water treatment costs, continuous improvements to the quality of water sources are needed.

Isolation and Identification of Bacteria Removing Sulfur Compound Odor (황 화합물계 악취 제거 미생물의 분리 및 동정)

  • 김진수;유용규;이상섭
    • Korean Journal of Microbiology
    • /
    • v.40 no.2
    • /
    • pp.127-132
    • /
    • 2004
  • We isolated 50 strains from sludge of wastewater treatment aeration tank using selective medium for Thio-bacillus sp. by membrane filtration method. They were identified as Thiobacillus neapolitanus (7), T. tepidarius (4), T. dientrificans (5), T. versutus (23), T. intermedius (2) and T. perometabolis (9). We selected Thiobacillus versutus strain KT51, which had the highest removal efficiency (100%) of hydrogen sulfide and the highest removal efficiency (85%) of dimethyl sulfide for 30 min in screen test. Also Thiobacillus versutus strain KT81 had the highest removal efficiency (26%) of dimethyl disulfide for 30 min in screen test. In applification of lab-scale reactor (closed-biological treatment) using Thiobacillus versutus strain KT51, results were 99.8% (<0.02 ppm) removal efficiency of hydrogen sulfide for 15 min.

Comparative Analysis of Offensive Odorants in Urine Samples in Relation to Sample Treatment Conditions (Urine 시료 중 지정악취성분에 대한 분석연구: 시료의 보관방법과 채취조건의 연계성 연구)

  • Lee, Min-Hee;Kim, Yong-Hyun;Jo, Sang-Hee;Choi, Si-On;Sa, Inyoung;Kim, Ki-Hyun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.5
    • /
    • pp.492-503
    • /
    • 2014
  • In this study, emission characteristics of volatile odorant species released from urine samples were investigated in relation to two key variables: [1] storage conditions before sampling and [2] incubation conditions during sampling. To this end, 20 offensive odorants were quantified by four different analytical systems and then sorted according to seven functional groups. It is indicated that benzene (B), styrene (S), isobutyl alcohol (i-BuAl), butyl acetate (BuAc), butyraldehyde (BA), isovaleraldehyde (IA), and valeraldehyde (VA) did not contribute to urine odor because their concentration levels were measured below detection limits in all samples. On the other hand, emission concentrations of toluene (T), methyl ethyl ketone (MEK), methyl mercaptan ($CH_3SH$), carbon disulfide ($CS_2$), and ammonia ($NH_3$) were generally higher than other compounds. In terms of odor intensity (OI), $CH_3SH$ and $NH_3$ showed the largest OI values in the range of 2~4. According to t-test (storage approach and urine temperature), the results of T, $CS_2$, and $NH_3$ were statistically distinguished from each other in terms of differences in sampling temperature. Likewise, the emissions of certain odorants from urine samples were affected by changes in sample treatment conditions to a degree.