• Title/Summary/Keyword: odor occurrence rate

Search Result 6, Processing Time 0.018 seconds

Evaluation of the Odor around an Industrial Complex Area and the Operational Effects of the Odor Monitoring System in Seo-gu, Daegu City (대구시 서구 산업단지 주변 지역의 악취오염도와 악취감시시스템 운영 평가)

  • Lee, Myeong-Sug;Keum, Jong-Lok;Kang, Dong-Hoon;Jo, Hang-Wook;Kwon, Byoung-Youne;Kim, Eun-Deok;Lee, Chan-Hyung;Song, Hee-Bong;Shin, Sang-Hee
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.1
    • /
    • pp.45-54
    • /
    • 2021
  • Objectives: This study evaluated the odor around an industrial complex area (#1-#5) and the operational effects of the Odor Monitoring System in Seo-gu in Daegu City. Methods: Samples were collected from November 2012 to December 2018 and were analyzed for complex odor. The odor occurrence rate and the odor reduction rate were calculated. Results: In 2018, the mean concentration of complex odor decreased 20.9% and the odor occurrence rate decreased from 65.0 to 27.5% around the industrial complex area (#1-#5) in Seo-gu compared to 2013. After the operation of the Odor Monitoring System, the standard excess rate (3.0%→40.8%) and the excess concentration of complex odor (1,442→4,304) increased at odor-emitting workplaces. In addition, the mean concentration of complex odor (15.9%) and the odor occurrence rate (60.6%→32.9%) around the industrial complex area (#1-#5) and the number of odor complaints (23.4%) in Seo-gu decreased. Conclusion: In order to reduce the odor around the industrial complex area, it is important to improve the odor emitting facilities. The Odor Monitoring System uses scientific and systematic monitoring methods that can help control and manage the odor emission facilities.

A Study on the Characteristics and Distribution of the Time-Spatial Occurrence of Offensive Odors -Gangwon Province - (악취의 시공간적 발생 특성 및 분포도 분석 - 강원지역을 대상으로 -)

  • Kim, Byoung-Ug;Hyun, Geun-Woo;Bae, Sun-Hak;Hong, Young-Kyun;Lee, Yeong-Seob;Yi, Geon-Ho;Huh, In-Ryang;Choi, Seung-Bong
    • Journal of Environmental Health Sciences
    • /
    • v.46 no.4
    • /
    • pp.376-387
    • /
    • 2020
  • Objectives: This study is aimed at offering basic data for making plans for offensive odor management after researching offensive odor occurrence and characteristics in Gangwon Province. Methods: The data used in the study is based on offensive odor data analyzed by the Gangwon Institute of Health and Environment from 2012 to 2019. The data were reclassified by year, month, facility, and region to identify characteristics of occurrence. Finally, a distribution map of offensive odors was created using ArcGIS. Results: The highest monthly frequency of offensive odor occurrence falls in June, August, and July, and the summer season and third quarter are the highest. According to the latest eight-year data for Gangwon Province, complaints about offensive odors in county areas are more frequent than those in city areas. There are many offensive odor complaints in Wonju, Cheorwon, and Heongsung. The main offensive odor emission facilities are livestock and waste treatment (recycling) facilities. Complaints about offensive odors are relatively lower the Yeongdong area than Yeongseo area, which is considered to be the result of characteristics of land-sea breezes and geographical factors. Offensive odors from livestock facilities count for an average of 53.9% of the total, and the inadequacy rate of livestock facilities averages 36.9%. Conclusions: To maintain a clean environment in Gangwon Province, it is strongly recommended that an offensive odor reduction plan for livestock facilities be established. Areas with a high density of offensive odor occurrence should be identified and systematically managed with short- and mid-term measures. If offensive odors is managed using GIS, it is possible to identify the characteristics of occurrence by time and space and also by facility. In addition, since systematic data management is possible, it is believed that a rapid response to offensive odors, prediction of their spread, and efficient management are possible.

A Study on the Distribution Characteristics of Sulfur Compounds in Ambient air using Continuous Monitoring Method in Incheon Area

  • Seo, Seok-Jun;Lim, Yong-Jae;Hong, You-deok;Park, Geon-Young
    • Journal of Integrative Natural Science
    • /
    • v.8 no.2
    • /
    • pp.128-134
    • /
    • 2015
  • This paper focuses on the applicability of a continuous monitoring method on trace sulfur compounds in the ambient air by TD and GC/PFPD. The target compounds for monitoring include H2S(hydrogen sulfide), Methyl mercaptan, Dimethyl Sulfide, and Dimethyl disulfide. The result of QA/QC on monitoring instruments satisfies all the standards of Odor Measurement and Analysis Method, showing that the reproductivity of the compounds by concentration is within 10%, linearity is above 0.98 of a correlation efficient, method detection limit is 0.16 ppb by MM standard, and recovery rate is over 70%. Monitoring was conducted for two years from March 2006 to February 2008. As a result of the monitoring, the average concentration of H2S was 0.08 ppb, with the maximum concentration at 16.15 ppb. The result indicates that it is reasonable to do continuous monitoring as there appears a spontaneous event of high concentration by the condition of the site during monitoring odor-causing substances. Therefore, it is suggested that the continuous monitoring method used in this paper is appropriate to identify the characteristics of sudden occurrence and concentration variations of sulfur compounds.

Occurrence and Repression of Off-Odor in Cooked Rice during Storage under Low Temperature Warming Condition of Electric Rice Cooker (전기밥솥으로 저온보온한 쌀밥의 이취 발생 및 억제)

  • Park, Seok-Kyu;Ko, Yong-Duck;Cho, Young-Sook;Shon, Mi-Yae;Seo, Kwon-Il
    • Korean Journal of Food Science and Technology
    • /
    • v.29 no.5
    • /
    • pp.919-924
    • /
    • 1997
  • The changes in physicochemical properties of cooked rice stored in an electric rice cooker at different temperature (63, 66, 69 and $72^{\circ}C$) were investigated. The growth of thermophilic bacteria was gradually increased in all samples with storage time up to 6 hours and increased rapidly afterward. The bacterial growth rate was higher during storage at low temperature than at high temperature, and the bacterial number generally reached the maximum at 18 hours of the storage. The number of bacteria in sample stored at $63^{\circ}C$ was increased to $10^6$ CFU/g after storage for 6 hours. The heat treatment at 6 hours of storage decreased the bacterial number to $10^5 $ CFU/g at 8 hours of storage. Bacterial number was gradually increased with storage time after the first heat treatment. When the sample was reheated after 8 hours of storage, the bacterial number was reduced to the level at which off-odor was not detected after storage for 24 hours. During the storage, moisture content of heat-treated sample was lower than that of sample stored at $63^{\circ}C$ but higher than that of sample stored at $72^{\circ}C$. The L value of heat-treated sample was higher than that of the sample stored at $72^{\circ}C$, but lower than that of the sample stored at $63^{\circ}C$. The b value showed an opposite trend to the L value with regard to the storage temperature. Changes in texture were not remarkable during the storage for the sample heat-treated and stored at low temperature. The occurrence of off-odor and browning was depressed in the heat-treated sample, and the texture and overall eating quality were more acceptable than the samples stored at low temperature.

  • PDF

A Study on Environmental Standards of School Building (교사환경기준에 관한 연구)

  • Hong, Seok-Pyo;Park, Young-Soo
    • The Journal of Korean Society for School & Community Health Education
    • /
    • v.1 no.1
    • /
    • pp.11-43
    • /
    • 2000
  • The purpose of this study was, through analyzing the previous researches, to grasp the present status of environment of school building(ESB), research the sundry records of each element and, through comparative analysis of the standard of ESB in Korea, the United States, and Japan, select the normative standard of ESB, to clarify the point at issue presented in Regulation of Construction & facility Management for Elementary and and Secondary School in Korea, and to suggest an alternative preliminary standard of ESB. To carry out a research for this purpose, these were required: 1. to investigate the existing present status of ESB, 2. to make a comparative analysis of the standard of ESB in each country, 3. to suggest the normative standard of preliminary standard of ESB, 4. to analyze the controversial points of the standard of ESB in Korea, 5. to suggest an alternative preliminary standard of ESB. The conclusions were as follows: 1. Putting, through analyzing the previous researches, the existing present status of ESB together, it seemed that lighting environment, indoor air environment and noise environment were all in poor conditions. 2. In the result of a comparative analysis of the standard of ESB in Korea, Japan and the United States, in Korea the factors of each lighting and indoor air environment were not presented properly, in Japan, in lighting environment aspect, the standard on natural lighting and the factors on brightness were not presented., and in the USA the essential factors of each environment were throughly presented. In the comparison of the standards on each factor, Korea showed that the standard level presented was less properly prescribed than those of the USA and Japan but it also showed that the standard levels prescribed in the USA and in Japan were mostly similar to the standard levels in records investigated. 3. With the result of the normative standard selection on School Builiding environment factor of prescribed in this study, the controversial points of the standard of ESB in Korea were analyzed and the result was utilized to suggest new preliminary standard of ESB. 4. As the result of the analysis of the controversial points of the standard of ESB in Korea, it was found that the standard of ESB in Korea should be established on a basis of School Health Act and be concretely presented in School Health Regulation and School Health Rule. The factors of each environment was improperly presented in the existing standard of ESB in Korea. Moreover the standard of them was inferior to that of the records investigated and those of in the USA and in Japan and it also showed that the standard of it in Korea was improper to maintain Comfortable Learning Environment. 5. A suggested preliminary standard of ESB acquired through above study as follows: 1) In this study a new kind of preliminary standard of ESB is divided into lighting environment, indoor air environment, noise environment, odor environment and for above classification, reasonable factor and standard should be established and the controling way on each standard and countermeasures against it should be considered. 2) In lighting environment, the factors of natural lighting are divided into daylight rate, brightness, glare. In the standard on each factor, daylight rate should secure 5% of a mean daylight rate and 2% of a minimum daylight rate, brightness ratio of maximum illumination to minimum illumination should be under 10:1, and in glare there should not be an occurrence factor from a reflector outside of the classroom. And the factors of unnatural lighting are illumination, brightness, and glare. In the standard on each factor, illumination should be 750 lux or more, brightness ratio should be under 3 to 1, and glare should not occur. And Optimal reflection rate(%) of Colors and Facilities of Classroom which influences lighting environment should be considered. 3) In indoor air environment factors, thermal factors are divided into (1) room temperature, (2) relative humidity, (3) room air movement, (4) radiation heat, and harmful gases (5) CO, (6) $CO_2$ that are proceeded from using the heating fuel such as oval briquettes, firewood, charcoal being used in most of the classroom, and finally (7) dust. In the standard on each factor, the next are necessary; room temperature: $16^{\circ}C{\sim}26^{\circ}C$(summer : $E.T18.9{\sim}23.8^{\circ}C$, winter: $E.T16.7{\sim}21.7^{\circ}C$), relative humidity: $30{\sim}80%$, room air movement: under 0.5m/sec, radiation heat: under $5^{\circ}C$ gap between dry-bulb temperature and wet-bulb temperature, below 1000 ppm of ca and below 10ppm of $CO_2$, dust: below 0.10 $mg/m^3$ of Volume of dust in indoor air, and ventilation standard($CO_2$) for purification of indoor air : once/6 min.(about 7 times/40 min.) in an airtight classroom. 4) In the standard on noise environment, noise level should be under 40 dB(A) and the noise measuring way and the countermeasures against it should be considered. 5) In the standard on odor environment, odor level under Physical Method should be under 2 degrees, and the inspecting way and the countermeasures against it should be considered.

  • PDF

Clean Flotation Process to Recycle useful Materials from Fly Ash (비산재로부터 유용성분을 회수하는 청정부유선별공정)

  • Han, Gwang Su;Kim, Dul-Sun;Lee, Dong-Keun
    • Clean Technology
    • /
    • v.26 no.3
    • /
    • pp.177-185
    • /
    • 2020
  • All coal ash, generated from coal-fired power plants, is entirely dumped onto a landfill site. As coal ash contains 80% fly ash, a clean floating process was developed in this study to recover useful components from coal ash and to use them as high value-added industrial materials. When the unburned carbon (UC) was recovered from the fly ash, soybean oil, an eco-friendly vegetable oil, was used as collector instead of a non-ionic kerosene collector to prevent the occurrence of odor from the kerosene. After the UC was separated by flotation, particulate ceramic microsphere (CM) was recovered, without generating acidic wastewater, through hydro-cyclone instead of sulfuric acid solution in order to separate ceramic microsphere (CM) and cleaned ash (CA) from the residue. By utilizing soybean oil as a collector, the recovery rate of UC turned high at 85.8% due to the increased adsorption of UC, the high viscosity of soybean oil, and the increase in floating properties caused by the linoleic acid contained in soybean oil. All of the combustible components contained in the recovered UC were carbon components, with the carbon content registering high when soybean oil was used. The recovered UC had many pores with a rough surface; thus, it could be easily ground and then used as an industrial material for its fine particles. The CM and CA recovered by the clean separation process using hydro-cyclone had a spherical shape, and the particles were clearly separated without clumping together. The average diameter (D50) of the particles was 5 ㎛, so it was possible to realize the atomization of CM through a process change.