• Title/Summary/Keyword: odor intensity

Search Result 144, Processing Time 0.023 seconds

Emission Characteristics of Odor Compounds from a Sewage Treatment Plant Near an Industrial Complex Area in Daegu City (대구시 산업단지 인근 하수처리장의 악취발생 특성)

  • Lee, Myeong-Sug;Kang, Dong-Hoon;Keum, Jong-Lok;Kwon, Byoung-Youne;Jo, Hang-Wook;Lee, Chan-Hyung;Kim, Eun-Deok;Lim, Ho-Jin;Song, Hee-Bong
    • Journal of Environmental Health Sciences
    • /
    • v.44 no.2
    • /
    • pp.178-187
    • /
    • 2018
  • Objectives: This study evaluated the odor emission characteristics from a sewage treatment plant near an industrial complex area in Daegu City. Methods: Odor samples were collected from March 2017 to December 2017 and analyzed for specified offensive odor substances. The odor quotient and the odor contribution were calculated. Results: Ammonia, methyl mercaptane, hydrogen sulfide, dimethyl sulfide, acetaldehyde, propionylaldehyde, toluene, xylene, and methylethylketone were detected in all samples for monitoring the specified odor compounds. The result of contribution analysis is that hydrogen sulfide made the highest contribution in all processes, followed by acetaldehyde. Conclusion: The major components of odor can be determined by evaluating their degree of contribution to the odor intensity and the concentration of the individual odor component. To increase the effectiveness of odor reduction, rather than addressing high-concentration odor compounds, policies focused on materials with a high odor contribution are necessary.

Emission Characteristics of Odor Compounds in a Charcoal Production Kiln (숯가마 배가스 중 악취물질의 배출특성)

  • Park, Seong-Kyu;Choi, Sang-Jin;Hwang, Ui-Hyun;Lee, Jeong-Joo;Kim, Daekuen
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.4
    • /
    • pp.319-326
    • /
    • 2014
  • Exhaust gas emitted as a result of the incomplete combustion of biomass in charcoal kilns includes odor compounds as well as other air pollutants such as particulate matters, sulfur and nitrogen oxides, and carbon monoxide. A number of offensive odor compounds affect quality of life. In this study, odor emissions were investigated from biomass burning in a pilot-scale charcoal kiln and a commercial-scale kiln. Complex odor from emission source reached up to 10,000 dilutions to threshold during the study period. Combustion fume was found to contain reduced sulfur compounds, aldehydes, and volatile organic compounds. Hydrogen sulfide and methyl mercaptan were the major odorants which highly contributed to the offensive odor.

An Investigation on the Odor Characteristics of Livestock Facilities (축산시설에서 발생되는 악취의 축종별 특성에 대한 설문조사)

  • Jang, Young-Kee;Song, Ki-Pong;Kim, Ho-Jung;Yoo, Yong-Hee
    • Journal of Environmental Impact Assessment
    • /
    • v.13 no.1
    • /
    • pp.33-40
    • /
    • 2004
  • At Recent the number of livestock is rapidly increased and the scale of farm has changed to large operations in Korea. So the odors from livestock feeding operations have increased and become major environmental problem. The odor emission are dependent on the types of manure management system and the meteorological factors. This report presents the results of a questionnaire on the odor characteristics from livestock facilities for the beef, dairy, swine and poultry. It is founded that the impact by odors from the facilities for swine and poultry is higher than cow and dairy, and the odor intensity at morning is higher than other times.

Survey on Public Responses to Odor Produced at Jangrim-Sinpyoeng Municipal and Industrial Wastewater Treatment Plant in Busan (신평장림 공단 폐수처리장 발생의 악취 조사연구)

  • Son, Hyun-Keun;Sivakumar, Subpiramaniyam;Yoon, Young-Hun
    • Journal of Environmental Health Sciences
    • /
    • v.37 no.3
    • /
    • pp.201-208
    • /
    • 2011
  • Objective: Emissions of volatile organic compounds (VOCs) from municipal wastewater treatment plants and industrial wastewater are often overlooked as sources of exposure to toxic chemicals. VOCs from such sources evaporate readily into the air and may have significantly adverse impacts on public health. The present study aimed to establish the concentration of VOCs released from Jangrim-sinpyoeng Municipal and Industrial Wastewater Treatment plant (JWTP) in Busan, South Korea and assess the causes of the odor/stench in the surrounding residential facilities. Stench intensity, frequency and release time, and wind direction were also monitored. Methods: Onsite data were collected on a daily basis from a laboratory located on the JWTP premises through a period spanning 2006 to 2010. A second set of data was obtained in 2006 by conducting a questionnaire survey with 210 respondents living near JWTP. The experimental and survey data were analysed statistically using the SPSS package. Results: The survey results showed that people residing around JWTP strongly perceive a stench from the plant. The intensity of the stench was influenced significantly by wind direction and the location of the apartments facing the JWTP. Public participation formed a significant step in determining the quality of the study environment. Conclusion: Onsite data and survey data obtained in 2006 indicate that the nature of the odor experienced by residents is due to the intensity of total VOCs released by JWTP. However, additional research is needed to determine the effects of the VOC pollution on public health and quality of life.

Masking Effect of Chlorine on Algae-related Taste and Odor in Drinking Water Supplies (염소의 상수원 내 조류 이취미 Masking 효과)

  • Kim, Young-il;Lee, Yu-Jeong;Shin, Heung-Sup;Bae, Byung-Uk
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.2
    • /
    • pp.227-232
    • /
    • 2008
  • The masking effect of chlorine on algae-related taste and odor(T&O) compounds has long been an important issue for water suppliers. In this study, masking experiments with chlorine were performed on two kinds of treated water and one of raw water. After adding chlorine(0 to 0.8 mg/L) to water samples, odor intensity was evaluated by a newly developed sensory method(2-out-of-5 odor test) for three days along with the measurement of residual chlorine concentration. Even though the relationship between the residual chlorine concentration and odor reported by the sensory analysts was not always coincident, it was proved that residual chlorine more than a certain concentration could completely mask both added geosmin and naturally occurring T&O compounds. For the sand-filtered water spiked with 10 ng/L of geosmin, 0.12-0.18 mg/L of residual chlorine was necessary to achieve complete masking. In the case of GAC-filtered water, 10 ng/L of spiked geosmin was completely masked by 0.15-0.1 mg/L of residual chlorine. Combined ozone and GAC was not enough to treat raw water spiked with 300 ng/L of geosmin. In this experiment, sensory analysts were able to detect earthy or musty odors from the treated water. From a masking experiment with raw water taken from the Daechung Reservoir, it was found that fishy odor was more difficult to mask with chlorine than earthy odor. As the chlorine residual declined, the analysts began to notice the original odor and the fishy odor was noticed earlier than the earthy odor.

A Study on Emission Characteristics of Odor Compounds from Waste Transfer Station (적환장에서 발생하는 악취 분포 특성에 관한 연구)

  • Jeon, Jae-Sik;Kim, Eun-Sook;Yoo, Seung-Sung;Oh, Seok-Ryul;Choi, Han-Young
    • Journal of Environmental Health Sciences
    • /
    • v.39 no.5
    • /
    • pp.418-425
    • /
    • 2013
  • Objective: This study was carried out for the purpose of identifying major substances contributing to the production of odor and evaluating the characteristic of odors. Methods: Complex odor and 17 odorous compounds were measured at 18 waste transfer stations located in Seoul. Results: The dilution ratio value of complex odor ranged from 4 to 30 times in the boundary layer of 18 waste transfer stations. At 6 measurement points among the 18 waste transfer stations, the dilution ratio values exceeded standards (15 times). When the results were evaluated in terms of their contribution to the formation of malodor, the patterns indicated that the highest concentration values in the residential waste disposal process were of i-valeraldehyde and acetaldehyde, while butyraldehyde and acetaldehyde accounted for a large proportion of odorous compounds from the waste recycling process. Conclusions: It was found that butyraldehyde and acetaldehyde were the primary compounds released from the food waste disposal process. Overall, aldehyde compounds were the greatest contributor to detectable odor intensity emitted at the waste transfer stations.

Changes in the Characteristics of Textile Products according to the Storage Environmental Condition for Sustainable Care (섬유제품의 지속가능한 관리를 위한 보관환경에 따른 특성변화 연구)

  • Kim, Jeong-Hwa;Lee, Sun-young;Lee, Jung-Soon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.46 no.3
    • /
    • pp.390-406
    • /
    • 2022
  • This study aims to establish the optimal environmental conditions for storing textile products. Four textile products (cotton, wool, nylon, cotton/polyurethane) were used to produce experimental fabrics according to artificial contamination and washing conditions. Each fabric was subjected to three environmental conditions (A: 20-25℃/20% RH, B: 20-25℃/50% RH, C: 30-35℃/65% RH) for 4-12 weeks. Changes in textile characteristics include tensile strength, wrinkle recovery rate, and odor intensity. Results show that the change in tensile strength for the four test fabrics slightly decreased with a storage time of 4 to 12 weeks. The wrinkle recovery rate of the fabrics was the lowest under the C condition. UV exposure causes a substantial decrease in the tensile strength of the textiles. The change in odor characteristics was the highest for the odor intensity in the C condition. For storing textile products for sustainable management, it is desirable to maintain a temperature of 20 to 25℃ with a relative humidity of 50% RH or less and to provide ventilation in an enclosed storage space that can also block UV rays.

Odor Emission from Sediments in Sewer Systems and Odor Removal using an Electrolytic Oxidation Process (하수관거에 퇴적된 유기물에 의한 악취 발생과 산화전리시스템을 이용한 악취 저감)

  • Ahn, Hae-Young;Shin, Seung-Kyu;Song, Ji-Hyeon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.6
    • /
    • pp.703-710
    • /
    • 2011
  • Odor emission from domestic sewer systems has become a serious environmental problem. An investigation on a sewer manhole revealed that anaerobic decay of sediment organic matters (SOMs) and related declines of oxidation reduction potential (ORP) in the sediment layer were the main reason of the production of volatile sulfur compounds. In addition, as the anaerobic decaying period continued, the odor intensity rapidly increased with increasing concentrations of $H_2S$ and dimethyl sulfide. As a feasible method to control SOMs and to minimize odor emission potentials, an electrolytic oxidation process has been employed to the sediment sludge phase. In this study, voltages applied to the electrolytic oxidation process were varied as a main system parameter, and its effects on odor removal efficiencies and reaction characteristics were investigated. At the applied voltages greater than 20 V, the system efficiently oxidized the organic matter, and the ORP in the sludge phase increased rapidly. As a consequence, the removal efficiency of hydrogen sulfide was found to be >99% within 60 minutes of the electrolytic oxidation. Overall, the electrolytic oxidation process can be an alternative to control odor emission from sewer systems, and a threshold input energy needs to be determined to achieve effective operation of the process.

Evaluation of Odors and Odorous Compounds from Liquid Animal Manure Treated with Different Methods and Their Application to Soils (액상 가축분뇨의 처리 및 토양환원에 따른 악취 및 악취물질의 평가)

  • 고한종;최홍림;김기연;이용기;김치년
    • Journal of Animal Science and Technology
    • /
    • v.48 no.3
    • /
    • pp.453-466
    • /
    • 2006
  • To comply with stricter regulations provoked by increasing odor nuisance, it is imperative to practice effective odor control for sustainable livestock production. This study was conducted to assess odor and odorous compounds emitted from liquid animal manure with different treatment methods such as Fresh Manure(without treatment, FM), Anaerobic Digestion(AD) and Thermophilic Aerobic Digestion(TAD) and their application to soil. Air samples were collected at the headspace of liquid manure, upland and paddy soil, and analyzed for odor intensity and offensiveness using an olfactometry; odor concentration index using odor analyser; nitrogen-containing compound such as ammonia(NH3) using fluorescence method; and sulfur containing compounds such as hydrogen sulfide(H2S), methyl mercaptan(MeSH), dimethyl sulfide(DMS) and dimethyl disulfide(DMDS) using gas chromatography-pulsed flame photometric detector, respectively. Odor intensity, offensiveness and concentration index from TAD liquid manure was statistically lower than those from FM and AD(p<0.01). Mean concentrations of H2S, MeSH, DMS, DMDS and NH3 were 65.93ppb, 18.55ppb, 5.26ppb, 0.33ppb and 10.57ppm for liquid manure with AD; and 5.15ppb, 0.97ppb, 0.80ppb, 0.56ppb and 1.34ppm for liquid manure with TAD, respectively. More than 60% of malodorous compounds related to nitrogen and sulfur were removed by heterotrophic microorganisms during TAD treatment. When liquid manure was applied onto upland and paddy soil, NH3 removal efficiencies ranged from 51 to 94% and 22 to 91% for AD and TAD liquid manure, respectively. The above results show that liquid manure with TAD is superior to AD and FM with respect to the odor reduction and odor problem caused by land applied liquid manure is directly related to the degree of odor generated by the manure treatment method.

Evaluation on the Degree of Satisfaction with Working Environment for Workers Engaged in the Composting Plant with Livestock Manure in the Han-river Watershed (한강유역 축분퇴비공장 근로자의 작업환경 만족도 평가)

  • Kim, K.Y.;Choi, H.L.;Kim, C.N.
    • Journal of Animal Science and Technology
    • /
    • v.44 no.2
    • /
    • pp.261-270
    • /
    • 2002
  • This study was executed to elucidate the degree of satisfaction with working environment and the factors affecting it for workers who are engaged in the composting plants with livestock manure in the Han-river watershed. As an evaluation on site, we applied the self-administered questionaire including general characteristics, working conditions, degree of satisfaction with working environment, and degree of satisfaction with working condition. Simultaneously, we analysed the exposure levels of odor (ammonia, hydrogen sulfide, and odor intensity) in the boundary area of plants. As a result of the study, health condition, odor, work load, dust, and smoking were proved to be the main factors affecting the degree of satisfaction with working environment for workers who are employed in the composting plants with livestock manure in the Han-river watershed. Of them, it was investigated that health condition, odor, and work load accounted for 61.3% of the total degree of satisfaction with working environment and health condition(p$<$0.01), odor(p$<$0.05), work load(p$<$0.05), and dust(p$<$0.05) were statistically significant. It was concluded that the degree of satisfaction with working environment was high for the workers who had good health status and low for the workers who had the relatively considerable work load and were often exposed to odor and dust. Therefore, to increase the degree of satisfaction with working environment for workers who are engaged in the composting plants with livestock manure, the measures that can reduce the exposure levels of odor and dust emitting from the composting plant with livestock manure should be improved.