• Title/Summary/Keyword: ocular

Search Result 851, Processing Time 0.021 seconds

A study of the manual procedure of ocular prosthesis (의안의 제조 방법에 관한 연구)

  • Kim, Jai Min;Park, Dong Hwa;Yoo, Geun Chang;Kim, Soon Ae;Cho, Seung Kwon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.2
    • /
    • pp.95-99
    • /
    • 2002
  • To investigate the manual procedure for custom fitting of ocular prosthesis and the cytotoxicity induced by extract solution of prosthetic eye, this study was performed. These procedures included the trial fitting of the wax model, impression molding, the an of iris color duplication, sclera mold made from the prosthetic wax model, scleral tints and vascular pattern, finishing and polishing. Inhibition of cell growth for extract solution was measured by MTT assay. Extract solution did not show the cytotoxicity. This study suggests that the manual procedure for custom fitting of ocular prosthesis is good for education of students.

  • PDF

The effect of the visual impairment on the Island Elder (섬지역 노인의 시력장애 요인 실태조사)

  • Kim, Jeong Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.2
    • /
    • pp.107-112
    • /
    • 2002
  • In order to investigate the situation of ocular disorders involving visual functions of elder in the Island area, the survey was carried out subjective methods on 228 persons(456 eyes) over the of 60. The analysis of data resulted in as follows : 1. Among the total 456 eyes, the ocular disorders was 54.8%. 2. The causes of ocular disorders with visual impairment ; Senile cataract(44.8%), Pterygium(55.2%) 3. Age distribution of cataract showed the sixties 46.4%, the seventies 37.5% and the eighties($80{\leq}$) 16.1%. 4. As to the distribution corrected visual acuity in cataract ; 0.1 below(8.9%). 0.1~0.3(14.3%), 0.4~0.6(36.6%), 0.7 over(40.2%). 5. Age distribution of pterygium showed the sixties 60.9%, the seventies 26.1% and the eighties($80{\leq}$) 13.0%. 6. As to the distribution corrected visual acuity in pterygium ; 0.1 below(5.l%), 0.1~0.3(5.8%), 0.4~0.6(20.3%), 0.7 over(68.8%).

  • PDF

Inferior Blow-Out Fracture Reduction Using Two Urinary Balloon Catheters

  • Jo, Eun Jun;Kim, Jong Hwan;Yang, Ho Jik
    • Archives of Craniofacial Surgery
    • /
    • v.16 no.3
    • /
    • pp.114-118
    • /
    • 2015
  • Background: The reduction of orbital blowout fracture primarily aims to normalize the extra-ocular movement by returning the herniated orbital soft tissue into the original position, and to prevent enophthalmos by normalizing the orbital cavity volume. We introduce a balloon catheter-assisted orbital floor reduction technique. Methods: A retrospective review was performed for all patients with orbital floor fracture who underwent the technique described in the main body of this text. Medical records were reviewed for demographic data, clinical presentation and course, degree of enophthalmos, intraorbital volume on computed tomography scan, and postoperative outcomes. The enophthalmos and intraorbital volume of the injured site were compared to the uninjured eye and orbit. Results: The review identified 14 patients (11 male, 3 female). The mean preoperative difference in en-exopthalmos was 2.13 mm, while the mean orbital volume was 116%. The mean postoperative difference in en-exophthalmos had improved to 0.61 mm with a mean orbital volume of 101.85%. At the time of catheter removal at 10 days, three patients experienced diplopia (n=1), extra-ocular movement disorder (1), or enophthalmos (1). All of these had resolved by the 6-month follow-up visit. Conclusion: Balloon catheter-assisted reduction of the orbital floor fractures was associated with improvements in intraorbital volume and enopthalmos in the 14 patients. Notable complications included diplopia, enophthalmos, and limited extra-ocular movement, all of which were transient in the early postoperative period and had resolved by 6-month follow up.

Treatment outcome and risk analysis for cataract after radiotherapy of localized ocular adnexal mucosa-associated lymphoid tissue (MALT) lymphoma

  • Park, Hee Hyun;Lee, Sea-Won;Sung, Soo Yoon;Choi, Byung Ock
    • Radiation Oncology Journal
    • /
    • v.35 no.3
    • /
    • pp.249-256
    • /
    • 2017
  • Purpose: We retrospectively reviewed the results of radiotherapy for localized ocular adnexal MALT lymphoma (OAML) to investigate the risk factors of cataract. Methods: Sixty-seven patients with stage IE OAML treated with radiotherapy at Seoul St. Mary's Hospital from 2001 to 2016 were included. Median treatment dose was 30 Gy. Lens protection was done in 52 (76%) patients. Radiation therapy (RT) extent was as follows: superficial (82.1%), tumor mass (4.5%), and entire orbital socket (13.4%). The risk factors for symptomatic cataract were analyzed using the Cox proportional hazard model. Results: Median follow-up time was 50.9 months (range, 1.9 to 149.4 months). All patients were alive at the time of analysis. There were 7 recurrences and there was no local recurrence. Median time to recurrence was 40.4 months. There were 14 cases of symptomatic cataract. Dose >30 Gy had hazard ratio of 3.47 for cataract (p = 0.026). Omitting lens protection showed hazard ratio of 4.10 (p = 0.008). Conclusions: RT achieves excellent local control of ocular MALT lymphoma. Consideration of RT-related factors such as lens protection and radiation dose at the stage of RT planning may reduce the risk of RT-induced cataract after radiotherapy.

The Characteristics of Diamond-like Carbon Films Deposited by Low Frequency(60Hz) Plasma CVD at Room Temperature for Optical lens (광학렌즈를 위한 저주파(60Hz) 플라즈마 CVD로 실온에서 제작한 다이아몬드성 탄소 박막의 특성)

  • Kang, Sung Soo;Lee, Won Jin;Sung, Duk Yong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.1 no.1
    • /
    • pp.23-28
    • /
    • 1996
  • Hydrogenated amorphous carbon films were fabricated by low frequency(60Hz) Plasma enhanced Chemical vapor deposition(LF-PECVD) at room temperature. The LF_PECVD has a couple of advantages as follows: cheap, and the employment of low power density makes the damage of samples small. The a-C:H films deposited in this work were highly transparent(99%), highly resistance(109-1011${\Omega}$-cm), and very uniform. The samples were deposited by the decomposition of CH4 and H2 mixing gas in the pressure rate range of 1% to 30%. The deposition rates, optical gap, and hydrogen contents are increased with CH4 contents.

  • PDF

A Study on the Exchange of Frames (안경테 교환에 관한 연구)

  • Yu, Dongsik;Lim, Hyeonseon;Lee, Soocheon;Hwang, Jeonghee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.4 no.2
    • /
    • pp.147-154
    • /
    • 1999
  • This study was performed to survey the exchange of frames on 83 persons. We investigated frame size, frame type, binocular prism effect etc. 80.4% among motives of frame-exchanges was a damage or corrosion. The type of frames was round-like 62.4% and 37.6% square-like. The size of frames was $49{\Box}18$ and vertical length 33mm on old-frames, $47{\Box}17$ and 31mm on new-frames. The scope of axis variation was average +3.20~3.80. According to estimation by the rule of RAL-RG 915, the inappropriate horizontal prism effect of new spectacles was 42.2%, more than 38.5% on old spectacles. The inappropriate vertical prism effect was 24.1% on old, 33.7% on new spectacles.

  • PDF

A Measurement and Analysis of Thermoluminescence Spectra of LaAlO3 (LaAlO3에 대한 열자극발광 스펙트럼의 광학적 분석)

  • Lee, J.I.;Moon, J.H.;Kim, D.H.
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.4 no.2
    • /
    • pp.141-146
    • /
    • 1999
  • We measured and analyzed thermoluminescence spectra of $LaAlO_3$, single crystal by 3 dimensional data for temperature, wavelength and luminescence intensity. $LaAlO_3$, has used as the substrates of YBCO(superconductor) or semiconductors. We could determined the energy of recombination center, that is impossible through analysis of glow curve data. We could obtained the energy through analysis of the spectrum data at peak temperature by Franck-Condon model. The total glow curve was deconvoluted to three glow curves by curve fitting method. The activation energies were 0.54eV, 0.91eV and 1.02eV respectively. The energies of recombination centers were determined with 2.04eV and 2.75eV from the analysis of luminescence intensity data for wavelength.

  • PDF

Studies on Permeation Enhancers for Ocular Peptide Delivery Systems: Pz-peptide as a Novel Enhancer of Ocular Epithelial Paracellular Permeability in the Pigmented Rabbit

  • Chung, Youn-Bok;Lee, Vincnet H.L.
    • Journal of Pharmaceutical Investigation
    • /
    • v.24 no.3
    • /
    • pp.49-57
    • /
    • 1994
  • The objective of this study was to determine whether Pz-peptide, an enhancer of hydrophilic solute permeability in the intestine, could elevate the paracellular permeability of the cornea and conjunctiva in the pigmented rabbit. The in vitro penetration of four hydrophilic solutes, mannitol (MW 182), fluorescein (MW 376), FD-4 (FITC-dextran, 4 KDa), and FD-10 (FITC-dextran, 10 KDa) across the pigmented rabbit cornea and conjunctiva was studied either in the presence or absence of 3 mM enhancers. Drug penetration was evaluated using the modified Ussing chamber. The conjunctiva was more permeable than the cornea to all four markers. EDTA and cytochalasin B showed higher effects on marker transport than Pz-peptide, but Pz-peptide elevated the corneal transport of mannitol, fluoresein, and FD-4 by 50%, 26%, and 50%, respectively, without affecting FD-10 transport. Possibly due to the leakier nature of the conjunctiva, 3 mM Pz-peptide elevated the transport of only FD-4 by about 45%, without affecting the transport of other markers. Furthermore, the transport of Pz-peptide itself across the cornea and conjunctiva increased with increasing concentration in the 1-5 mM range, suggesting that Pz-peptide enhanced its own permeability, possibly by elevating paracellular permeability. Effects of ion transport inhibitors on Pz-peptide transport were then investigated. PZ-peptide penetration was not changed by mucosal addition of $10\;{\mu}M$ amiloride or $10\;{\mu}M$ hexamethylene amiloride, inhibiting serosal $Na^{+}$ exit by $100\;{\mu}M$ ouabain, or replacing $Na^{+}$ with choline chloride in the mucosal side buffer. These results seggested that Pz-peptide enhanced the paracellular permeability of rabbit cornea and conjunctiva and further indicate that ion transporters were not involved in the Pz-peptide induced elevation of paracellular marker permeability.

  • PDF

The Analysis of Normal Values on the Ocular Protrusion and Height of Palpebral Fissure on Women University Students in Korean (한국 여자 대학생들의 검열 폭과 안구돌출의 정상 값 분석)

  • Kim, Douk-Hoon;Kwok, L. Stephen
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.2
    • /
    • pp.139-144
    • /
    • 2005
  • The purpose of this study was undertaken to determine the analysis of normal values of height of palpebral fissure and Hertel exophthalmometry in Korean woman university students. These measurements were taken from 118 health subjects aged 18-21 years in Korea. In 18-21 years, the mean values of height of palpebral fissure were $6.967{\pm}1.599mm$, $7.172{\pm}1.502mm$, $8.015{\pm}1.44mm$ and $7.1{\pm}1.224mm$, respectively. However, In 18-21 years, the mean values of protrusion were $12.50{\pm}2.33mm$, $12.343{\pm}2.634mm$, $12.773{\pm}1.974mm$ and $13.036{\pm}2.23mm$, respectively. As a results, according to increase the aging, the palpebral fissure height and ocular protrusion was more increase. But in 21 ages the palpebral fissure was some decrease. Also in 19 ages the protrusion was some decrease. On the other hand, the right and left eye have not statistically significant.

  • PDF