• Title/Summary/Keyword: occupational health and safety risk assessment

Search Result 278, Processing Time 0.024 seconds

Estimation of an Occupational Exposure Limit for Multi-Walled Carbon Nanotubes Manufactured in Korea (국내 일부 다중벽탄소나노튜브의 직업노출기준 추정)

  • Kim, Jong Bum;Kim, Kyung Hwan;Choi, Byung-Gil;Song, Kyung Seuk;Bae, Gwi-Nam
    • Journal of Environmental Science International
    • /
    • v.25 no.4
    • /
    • pp.505-516
    • /
    • 2016
  • With the development of nanotechnology, nanomaterials are used in various fields. Therefore, the interest regarding the safety of nanomaterial use is increasing and much effort is diverted toward establishment of exposure assessment and management methods. Occupational exposure limits (OELs) are effectively used to protect the health of workers in various industrial workplaces. This study aimed to propose an OEL for domestic multi-walled carbon nanotubes (MWCNTs) based on animal inhalation toxicity test. Basic procedure for development of OELs was examined. For OEL estimation, epidemiological study and quantitative risk assessment are generally performed based on toxicity data. In addition, inhalation toxicity data-based no observed adverse effect level (NOAEL) and benchmark dose (BMD) are estimated to obtain the OEL. Three different estimation processes (NEDO in Japan, NIOSH in USA, and Baytubes in Germany) of OELs for carbon nanotubes (CNTs) were intensively reviewed. From the rat inhalation toxicity test for MWCNTs manufactured in Korea, a NOAEL of $0.98mg/m^3$ was derived. Using the simple equation for estimation of OEL suggested by NEDO, the OEL of $142{\mu}g/m^3$ was estimated for the MWCNT manufacturing workplace. Here, we used test rat and Korean human data and adopted 36 as an uncertainty factor. The OEL for MWCNT estimated in this work is higher than those ($2-80{\mu}g/m^3$) suggested by previous investigators. It may be greatly caused by different physicochemical properties of MWCNT and their dispersion method and test rat data. For setting of regulatory OELs in CNT workplaces, further epidemiological studies in addition to animal studies are needed. More advanced technical methods such as CNT dispersion in air and liquid should be also developed.

A Comparison of Dose-Response Assessments for CMR Materials in the Workplace (작업장에서 취급하는 CMR물질의 용량반응평가 방법 비교)

  • Lee, Kyung Hwa;Choi, Han Young;Kim, Chi Nyon;Roh, Young Man;Choi, Hee Jin;Park, Chae Ri
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.28 no.1
    • /
    • pp.51-60
    • /
    • 2018
  • Objectives: Currently, there is only limited knowledge regarding the hazard of low-level exposure to CMR materials in workplaces. To overcome this limitation, a reference concentration for workers($RfC_w$) from among the risk assessment tools proposed by the US EPA is widely used to set a provisional workplace exposure level(PWEL) for CMR materials for which there are no established Korea Occupational Exposure Limits(KOELs) or subjective chemicals for work environment measurements as regulated by Korea Ministry of Employment and Labor(KMOEL). A simple European calculator of derived no effect level(SECO-DNEL) as proposed by REACH can also be used in place of $RfC_w$ to set the PWEL for chemicals. This study was performed to test the acceptability of using SECO-DNEL as an alternative to $RfC_w$ when setting a PWEL for low-level exposures. Methods: The $RfC_w$ and DNEL for the five CMR materials of dinitrogen oxide, catechol, 2-phenoxy ethanol, carbitol, and carbon black were calculated using the dose-response assessments of the US EPA for $RfC_w$ and REACH guidance for SECO-DNEL, respectively. They were compared using paired t-tests to determine the statistical differences between them. Results: For the five chemicals, the $RfC_w$ were 2.53 ppm, 0.10 ppm, 1.73 ppm, 1.66 ppm, and $0.05mg/m^3$, respectively, while the SECO-DNEL were 2.01 ppm, 0.11 ppm, 1.83 ppm, 1.77 ppm, $0.14mg/m^3$, respectively. There was no statistically significant difference between $RfC_w$ and SECO-DNEL. Conclusions: This study suggests that the SECO-DNEL could be applied in place of $RfC_w$ to set a PWEL for low-level exposure to chemicals, especially CMR materials. To further ensure the reliability of SECO-DNEL as an alternative tool, more chemicals should be applied for calculation and comparison with $RfC_w$.

Evaluation of Extremely Low Frequency Magnetic Fields emission Level from High Voltage Transmission Lines (고압 송전선로에서 극저주파 자기장 영향평가 적용에 관한 연구)

  • Jung, Joon Sig;Choi, Sung Ho;Jeon, Hyung Jin;Kim, Yoon Shin;Hong, Seung Cheol
    • Journal of Environmental Impact Assessment
    • /
    • v.23 no.5
    • /
    • pp.353-363
    • /
    • 2014
  • The purpose of this study was to investigated the ELF-MF emission level of various environments such as 258 facilities near located to high voltage transmission lines and 120 high voltage transmission lines, 17 underground cable lines. In addition, ELF-MF reduction rate according to separation distance was calculated by using simulations. An appropriate separation distance showing below 4mG was at least 70m. In the case of the appropriate separation distance for 120 high voltage transmission lines, 154kV required 20m of separation distance and 345kV required 60m of separation distance. The simulation results showed that the appropriate separation distance showing below 4mG was 40m and 60m for overhead 154kV and 345kV respectively. To adjust the worst conditions considering the aspects of environmental impact assessment study and the electric power currents that will increase in the future, the appropriate minimum separation distance for HVTL is judged to be above 70m in this study. Thus, there is a need to establish the greenbelt or buffer zone within 70m so as to create an environment in which the receptors are not exposed and thereby eliminate the risk factors of ELF-MF against humans.

Exposure Assessment of Korean Farmers While Applying Chlorpyrifos, and Chlorothalonil on Pear and Red Pepper (노지고추 및 배 재배 농업인의 방제작업 중 Chlorpyrifos, Chlorothalonil 노출에 관한 연구)

  • Kang, Tae-Sun;Kim, Gil-Joong;Choe, In-Ja;Kwon, Young-Jun;Kim, Kyung-Ran;Lee, Kyung-Sook
    • Journal of agricultural medicine and community health
    • /
    • v.29 no.2
    • /
    • pp.249-263
    • /
    • 2004
  • Objectives: The objectives of the present study were to establish the exposure monitoring method of chlorpyrifos and chlorothalonil application to pear and field red pepper by vehicle-mounted sprayer, hand-held sprayer and to assess the risk. Methods and Results: Chlorpyrifos met all of requirements of sampling and analysis method(U.S. EPA), but chlorothalonil met only dermal patch method. Potential dermal and inhalation exposure was evaluated in 42 farmers. Compared with the hand-held sprayer application, vehicle mounted sprayer demonstrated producing relatively lower dermal exposure levels with statistical significance. In dermal exposure during hand-held application, there is no significant difference between pear and red pepper. Conclusions: This results show that application method is the main factor of dermal exposure. There was no statistically significant difference between each group of respiratory exposure level. The margin of safety (MOS) was calculated to assess the risk of pesticide exposure. All Chlorpyrifos MOS values are lower than 0.2, which mean working conditions are unsafe. In order to protect farmers, big efforts to control exposure are needed.

  • PDF

Assessment of Defect Risks in Apartment Projects based on the Defect Classification Framework (효율적인 품질관리를 위한 공동주택 하자위험 분석)

  • Jang, Ho-Myun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.11
    • /
    • pp.510-519
    • /
    • 2019
  • The aim of this study was to set a defect classification framework and evaluate the defect risks in apartment buildings For this, approximately 15,056 defect items for 133 apartment buildings were examined. As a result of the analysis, the major defect of the RC work was cracks, which were found mainly in public locations. Moreover, the RC work was found to exhibit a high defect risk of water problem and surface appearance, which are highly connected with cracks. Second, the finish work has a high defect risk because it is composed of various work types, and there are many kinds of materials and construction parts involved. Third, the major defects of the waterproof work were incorrect installation and missing tasks, which have high defect risks in the garage. This is because defects that require rework occur mainly in the underground garage. Based on these results, this study proposed countermeasures for defect risk management to be considered in the construction, handover, post-handover, and occupancy phases. These have been set in detail based on the three zones: low frequency high severity (LFHS), low frequency low severity (LFLS), and high frequency low severity (HFLS).

New Smoke Risk Assessment on Wood Treated with Silicone Compound (실리콘 화합물로 처리된 목재의 새로운 연기위험성 평가)

  • Chung, Yeong-Jin;Jin, Eui
    • Fire Science and Engineering
    • /
    • v.33 no.4
    • /
    • pp.16-27
    • /
    • 2019
  • A burning test was conducted on the smoke and combustion gases generated from cypress wood treated with sodium silicate, 3-aminopropyltrimethoxysilane sol, 3-(2-aminoethylamino)propylmethyldimethoxysilane sol, and 3-(2-aminoethylamino) propyltrimethoxysilane sol. The silicone compound sol was applied to each of the cypress wood specimens three times with a brush. The smoke and combustion generation gas were analyzed using a cone calorimeter (ISO 5660-1) and the smoke was also evaluated by applying new smoke risk assessment method. The smoke performance index (SPI) of the cypress treated with silicone compound increased 1.66 to 8.42 times and the smoke growth index (SGI) was 11.8 to 88.2%, respectively. The smoke intensity (SI) is expected to be 1.0~50.5% lower than that of the base specimens, resulting in lower smoke and fire hazards. The third maximum carbon monoxide (COpeak) concentration of the specimens treated with silicone compounds was 22.5~33.3% lower than that of the base specimens. On the other hand, it produced potentially fatal toxicity that was 1.48~1.72 times higher than the US Occupational Safety and Health Administration (OSHA) acceptance standard (PEL). Cypress wood itself produced a high carbon monoxide concentration, but the silicon compound played a role in reducing this level.

A Study for the Appropriateness of the Different Reference Points in the Analysis of Working Posture

  • Kim, Day-Sung;Kim, Chol-Hong
    • Journal of the Ergonomics Society of Korea
    • /
    • v.30 no.5
    • /
    • pp.637-644
    • /
    • 2011
  • Objective & Background: When applying various evaluation tools that analyze work posture risk through observation, accurate measurement of body flexion angle is very important. Method: This study investigated differences and appropriateness of 5 different existing reference points commonly used in the analysis of the work posture. Twenty five ergonomist and trained professionals were participated in this study. A Same flexion angle was utilized for the evaluation of risk assessment of musculoskeletal disorders using five different reference points to investigate the degree of difference between them. To investigate how different the observers' preferred flexion angle measuring methods were compared to the ISO 11226 Reference Posture, a virtual body model was constructed using the Poser 6.0 program. Six types of body flexion postures were constructed, and since neck flexion differs according to body angle, five types of neck flexion postures were constructed with the trunk bending $20^{\circ}$ forward, making up a total of 30 virtual flexion postures. Results: Results showed that the observers used personally preferred reference points instead of reference points recommend in the evaluation tools. Also the results revealed the their seems to be 6 types of flexion angle for the trunk and 11 types of measurement methods for the neck flexion angle in the form of personally preferred reference points. The results showed that a mean difference of $14^{\circ}$($4{\sim}23^{\circ}$) occurred in the trunk, and a mean difference of $20^{\circ}$($-8{\sim}51^{\circ}$) occurred in the neck. To increase accuracy when using the 5 evaluation tools in combination, the ISO 11226 standards, observers' preferred flexion posture standards, and common flexion posture standards of the evaluation tools were compared with the reference points of the 5 evaluation tools. Results showed considerable variance in angle difference for each evaluation tool. Conclusion: According to the results of this study, considering the angle difference between the flexion angle reference points of the evaluation tool and the reference points selected by the observers, it is concluded that instead of personally preferred reference points, the standardized reference points to enhance the accuracy and the objectivity. Application: The result of this study can be used as reference guide to develop the standardized reference point in the future.

A Study of Establishment of the Infrastructure for Consequence Analysis of Metallic Dust Explosion (금속성 분진폭발의 영향 분석을 위한 기반구축에 관한 연구)

  • Jang, Chang Bong;Lee, Kyung Jin;Moon, Myong Hwan;Baek, Ju Hong;Ko, Jae Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.4
    • /
    • pp.84-91
    • /
    • 2017
  • Recent years have witnessed the increased usage of flammable metals, such as aluminum or magnesium, in wide range of high-tech industries. These metals are indispensable for the improvement of physical properties of materials as well as the design capability of the final product. During the process, unwanted metal dusts could be released to the environment. This can lead to an occupational health and safety issues. Due to their flammable nature, more serious problem of an explosion can happen in extreme cases. The explosion is the combustion of tiny solid particles and vapor mixture, caused by pyrolysis. This complex composition makes engineering analysis more difficult, compared to simple gas explosions or vapor cloud combustions. The study was conducted to assess this light metal dust explosion in an effort to provide the bases for a risk assessment. Dust explosion characteristics of each material was carefully evaluated and an appropriate analysis tool was developed. A comprehensive database was also constructed and utilized for the calibration of the developed response model and the verification for its accuracy. Subsequently, guidelines were provided to prevent dust explosions that could occur in top-notch industrial processes.