• 제목/요약/키워드: occlusal stability

검색결과 149건 처리시간 0.021초

치과용 임플란트 지대주나사의 조임체결력에 따른 지지골과 지대주나사의 유한요소법 응력 분석 (A finite element stress analysis on the supporting bone and abutment screw by tightening torque of dental implant abutment screw)

  • 이명곤
    • 대한치과기공학회지
    • /
    • 제42권2호
    • /
    • pp.99-105
    • /
    • 2020
  • Purpose: A study analysed the stress distribution of abutment screw and supporting bone of fixture by the tightening torque force of the abutment screw within clinical treatment situation for the stability of the dental implant prosthesis. Methods: The finite element analysis was targeted to the mandibular molar crown model, and the implant was internal type 4.0 mm diameter, 10.0 mm length fixture and abutment screw and supporting bone. The occlusal surface was modeled in 4 cusps and loaded 100 N to the buccal cusps. The connection between the abutment and the fixture was achieved by combining three abutment tightening torque forces of 20, 25, and 30 Ncm. Results: The results showed that the maximum stress value of the supporting bone was found in the buccal cortical bone region of the fixture in all models. The von Mises stress value of each model showed 184.5 MPa at the 20 Ncm model, 195.3 MPa in the 25 Ncm model, and 216.5 MPa in the 30 Ncm model. The contact stress between the abutment and the abutment screw showed the stress value in the 20 Ncm model was 201.2 MPa, and the 245.5 MPa in the 25 Ncm model and 314.0 MPa in the 30 Ncm model. Conclusion: The increase of tightening force within the clinical range of the abutment screw of the implant dental prosthesis was found to have no problem with the stability of the supporting bone and the abutment screw.

하악 임플란트 고정성 보철에 대합되는 상악 총의치 하방의 골흡수에 대한 고찰 및 증례보고 (Maxillary Resorption under Complete Dentures Opposing Mandibular Implant Supported Fixed Prosthesis: A Literature Review and Case Report)

  • 김보국;김유리
    • 구강회복응용과학지
    • /
    • 제29권4호
    • /
    • pp.426-433
    • /
    • 2013
  • 완전 무치악 환자를 총의치로 수복할 때 특히 하악의 경우 유지, 지지 면적이 상악보다 좁아 의치의 탈락, 불량한 지지 및 안정성, 통증을 유발하여 의치의 사용이 불편할 수 있다. 이런 환자에서 임플란트를 이용한 보철수복은 심미성, 안정성, 저작력을 향상시킬 수 있다. 반면 상악 완전무치악은 구개를 이용할 수 있으므로 총의치로 수복하였을 때 많은 환자들이 잘 적응하여 사용하고 있다. 이에 상하악 완전 무치악 환자의 치료 옵션으로 하악은 임플란트로 지지를 받는 고정성 보철물 또는 임플란트 오버덴쳐로 수복하고 상악은 연조직에 의해 지지를 받는 전통적인 총의치로 수복하는 전악 보철수복이 제시되었다. 이 때 상악 총의치에 대합하는 하악 임플란트 고정성 보철이 상악 잔존치조제의 골흡수에 어떠한 영향을 미치는지에 대한 문헌고찰과 함께 증례를 보고하고자 한다.

내부연결방식 임플랜트 시스템의 삼차원 유한요소법적 연구 (THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF INTERNALLY CONNECTED IMPLANT SYSTEMS)

  • 김유리;조혜원;이재봉
    • 대한치과보철학회지
    • /
    • 제44권1호
    • /
    • pp.85-102
    • /
    • 2006
  • Statement of problem: Currently, there are some 20 different geometric variations in implant/abutment interface available. The geometry is important because it is one of the primary determinants of joint strength, joint stability, locational and rotational stability. Purpose: As the effects of the various implant-abutment connections and the prosthesis height variation on stress distribution are not yet examined this study is to focus on the different types of implant-abutment connection and the prosthesis height using three dimensional finite element analysis. Material and method. The models were constructed with ITI, 3i TG, Bicon, Frialit-2 fixtures and solid abutment, TG post, Bicon post, EstheticBase abutment respectively. And the super structures were constructed as mandibular second premolar shapes with 8.5 mm, 11 mm, 13.5 mm of crown height. In each model, 244 N of vertical load and 244 N of $30^{\circ}$ oblique load were placed on the central pit of an occlusal surface. von Mises stresses were recorded and compared in the crowns, abutments, fixtures. Results: 1. Under the oblique loading, von Mises stresses were larger in the crown, abutment, fixture compared to the vertical loading condition. 2. The stresses were increased proportionally to the crown height under oblique loading but showed little differences with three different crown heights under vertical loading. 3. In the crown, the highest stress areas were loading points under vertical loading, and the finish lines under oblique loading. 4. Under the oblique loading, the higher stresses were located in the fixture/abutment interface of the Bicon and Frialit-2 systems compared to the ITI and TG systems. Conclusions: The stress distribution patterns of each implant-abutment system had difference among them and adequate crown height/implant ratio was important to reduce the stresses around the implants.

티타늄 합금, 지르코니아, 폴리에테르에테르케톤 지대주 재질에 따른 임플란트 구성요소의 응력분포: 유한 요소 분석을 통한 비교 연구 (Stress distribution in implant abutment components made of titanium alloy, zirconia, and polyetheretherketone: a comparative study using finite element analysis)

  • 김성민
    • 대한치과기공학회지
    • /
    • 제46권2호
    • /
    • pp.21-27
    • /
    • 2024
  • Purpose: This study aimed to analyze the stress distribution and deformation in implant abutments made from titanium (Ti-6Al-4V), zirconia, and polyetheretherketone (PEEK), including their screws and fixtures, under various loading conditions using finite element analysis (FEA). Methods: Three-dimensional models of the mandible with implant abutments were created using Siemens NX software (NX10.0.0.24, Siemens). FEA was conducted using Abaqus to simulate occlusal loads and assess stress distribution and deformation. Material properties such as Young's modulus and Poisson's ratio were assigned to each component based on literature and experimental data. Results: The FEA results revealed distinct stress distribution patterns among the materials. Titanium alloy abutments exhibited the highest stress resistance and the most uniform stress distribution, making them highly suitable for long-term stability. Zirconia abutments showed strong mechanical properties with higher stress concentration, indicating potential vulnerability to fracture despite their aesthetic advantages. PEEK abutments demonstrated the least stress resistance and higher deformation compared to other abutment materials, but offered superior shock absorption, though they posed a higher risk of mechanical failure under high load conditions. Conclusion: The study emphasizes the importance of selecting appropriate materials for dental implants. Titanium offers durability and uniform stress distribution, making it highly suitable for long-term stability. Zirconia provides aesthetic benefits but has a higher risk of fracture compared to titanium. PEEK excels in shock absorption but has a higher risk of mechanical failure compared to both titanium and zirconia. These insights can guide improved implant designs and material choices for various clinical needs.

구강 접근과 트로카를 이용한 하악 과두하부 골절의 정복과 고정 (OPEN REDUCTION AND TRANSORAL FIXATION USING TROCHAR FOR MANDIBULAR SUBCONDYLE FRACTURE)

  • 허준영;김종윤;임재형;박광호;허종기
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제32권1호
    • /
    • pp.43-48
    • /
    • 2010
  • The mandibular condyle fracture occurs at 15-30% frequency of whole mandibular fracture. The treatment of choice is open reduction or closed reduction. In many cases, closed reduction is preferred for treatment of condylar fracture because it is hard to approach to condyle and there is risk of surgical complications, such as nerve damage in open reduction. Open reduction, however, has some advantages like possibility of anatomical reduction, occlusal stability and rapid functional recovery. Furthermore, it is possible to retain original ramal heights and to decrease deviation during mouth opening. There are many surgical approaches for open reduction of subcondyle fracture. At present, transoral approach using trochar device is tried for effective and minimally invasive method for open reduction of subcondyle fracture. And the authors report the cases of reduction of subcondyle fracture with transoral approach using trochar device.

임플란트 나사의 안정성 (Stability of implant screw joint)

  • 정재헌;곽종하;장두익
    • 구강회복응용과학지
    • /
    • 제19권2호
    • /
    • pp.125-137
    • /
    • 2003
  • The use of screw-retaind prosthesis on an osseointegrated implant is a popular treatment modality offering relative ease in the removal of the restoration. One of the complications associated with this modality is the loosening of the abutment and coping screws. Loosening of the screws results in patient dissatisfaction, frustration to the dentist and, if left untreated, component fracture. There are several factors which contribute to the loosening of implant components which can be controlled by the restorative dentist and lab technician. This article offers pratical solutions to minimize this clinical problem and describes the factors involved in maintaining a stable screw joint assembly. To avoid joint failure, adherence to specific clinical, as well as mechanical, parameters is critical. With respect to hardware, optimal tolerance and fit, minimal rotational play, best physical properties, a predictable interface, and optimal torque application are mandatory. In the clinical arena, optimal implant distribution; load in line with implant axis; optimal number, diameter, and length of implants; elimination of cantilevers; optimal prosthesis fit; and occlusal load control are equally important.

악교정수술 후 조기 재수술 증례의 분석 (Clinical analysis of early reoperation cases after orthognathic surgery)

  • 이주환;이인우;서병무
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제36권1호
    • /
    • pp.28-38
    • /
    • 2010
  • The factors influencing the relapse and recurrence of skeletal deformity after the orthognathic surgery include various factors such as condylar deviation, the amount of mandibular set-back, stretching force by the soft tissues and muscles around the facial skeleton. The purpose of this report is to recognize and analyze the possible factors of reoperation after orthognathic surgery, due to early relapses. Six patients underwent reoperation after the orthognathic surgeries out of 110 patients from 2006 to 2009 were included in this study. In most cases, clincal signs of the insufficient occlusal stability, anterior open bite, and unilateral shifting of the mandible were founded within 2 weeks postoperatively. Although elastic traction was initiated in every case, inadequate correction made reoperation for these cases inevitable. The chief complaints of five cases were the protruded mandible combined with some degree of asymmetric face and in the other one case, it was asymmetric face only. Various factors were considered as a major cause of post-operative instability such as condylar sagging, counter-clockwise rotation of the mandibular segment, soft tissue tension related with asymmetrical mandibular set-back, preoperatively existing temporomandibular disorder (TMD), poor fabrication of the final wafer, and dual bite tendency of the patients.

Camouflage treatment of posterior bite collapse in a patient with skeletal asymmetry by using posterior maxillary segmental osteotomy

  • Badr, Haitham;Lee, Soo-Yeon;Park, Hong-Sik;Ohe, Joo-Young;Kang, Yoon-Goo;Ahn, Hyo-Won
    • 대한치과교정학회지
    • /
    • 제50권4호
    • /
    • pp.278-289
    • /
    • 2020
  • Orthodontic treatment of posterior bite collapse due to early loss of molars and the consequent drift of adjacent teeth is complicated. When the posterior bite collapse occurs in patients with facial asymmetry, both transverse and vertical compensation are necessary for camouflage orthodontic treatment. In such cases, posterior maxillary segmental osteotomy (PMSO) can be an effective alternative procedure that simplifies the orthodontic treatment and shows long-term stability through dental compensation within the alveolar bone housing. This case report aimed to describe the orthodontic treatment of maxillary occlusal plane canting caused by severely extruded maxillary teeth in a patient with skeletal facial asymmetry that was corrected with PMSO along with protraction of the lower second molar to replace the space of the extracted first molar. The treatment duration was 18 months, and stable results were obtained after 2 years of retention.

저작근의 피로가 치아접촉안정성 및 저작근활성에 미치는 효과 (The Effect of Masticatory Muscle Fatigue on the Occlusal Contact Stability and Masticatory Muscle Actibities)

  • Hye-Yeong Kim;Sun-Ha Kim;Jae-Kap Choi
    • Journal of Oral Medicine and Pain
    • /
    • 제17권1호
    • /
    • pp.41-50
    • /
    • 1992
  • The authors performed a experimental study to evaluate the effects of masticatory muscle fatigue on tooth contact and masticatory muscle activity in 26 normal healthy women. The experimental masticatory muscle fatigue was induced by unilateral biting of 5kg force on mandibular first molar. The results were as follows : 1. The initial symptom related to muscle fatigue pain appeared in 85.19 seconds of isometric contraction and the endurance time of isometric contraction was 203.15 seconds. 2. The pain occurred more frequently in masseter region than in temporal region. In masseter pain the incidence was almost equal between both sides, whereas the temporal pain was more in contralateral side. 3. The spontaneity and the symmetry of tooth contact during maximum clenching were reduced after isometric unilateral biting. 4. After induction of experimental muscle fatigue, the EMG activities of masseter muscles of both sides and ipsilateral temporal muscle showed the tendency of decreasing activities. 5. The asymmetry indicies of masseter and temporal muscles were reduced after isometric bilateral biting.

  • PDF

구강 및 구인두종양수술시 구순-하악골이단 접근법의 이용에 관한 임상적 연구 (A CLINICAL STUDY ON THE APPLICATION OF LABIO-MANDIBULOTOMY APPROACH FOR ORAL AND OROPHARYNGEAL TUMORS)

  • 표성운
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제21권2호
    • /
    • pp.225-230
    • /
    • 1999
  • The labiomandibulotomy approch to the oral cavity and oropharygeal region was first described by Roux in 1836 and become popular for oral and oropharyngeal tumors in cases where there are no clinical and radiological signs of mandible invasion. Anterior labiomandibulotomy and swing procedure provides excellent access and facilitate a mandibular resection and subsequent repair. In last two years, 8 cases of oral and oropharyngeal tumors were treated by this approach at the Dept. of Oral & Maxillofacial Surgery, Holy Family Hospital, Catholic University of Korea. And we analyzed postoperative complications as well as functional evaluations, and the results were as follows; In 4 cases, marginal mandibulectomy were combined with labiomandibulotomy and in case of malignancies, neck dissection was performed simultaneously. In almost case, plate and miniscrew fixation was used for osteotomy sites. Histologic evaluation of the resection margins of the specimens revealed tumor free in all cases. The postoperative complications were occured in 3 cases, one case of nonunion, one case of orocutaneous fistula, and one case of wound dehisence. Occlusal stability, jaw movement and swallowing function were acceptable postoperatively in 3 months. From above results, we concluded that, this approach not only provides wide exposure, permitting radical removal of benign and malignant lesions but also preserves function with minimal complications.

  • PDF