• 제목/요약/키워드: occlusal conditions

검색결과 80건 처리시간 0.02초

Recovery from Acute Malocclusion in Temporomandibular Disorders with Stabilization Splint: Case Report

  • Kim, Ji-Rak
    • Journal of Oral Medicine and Pain
    • /
    • 제46권1호
    • /
    • pp.14-19
    • /
    • 2021
  • Various conditions such as pain or effusion of temporomandibular joint, degenerative condylar resorption, and articular disc displacement can be a cause of malocclusion. However, the reasons of occlusal changes are ambiguous in some patients. Unexpected occlusal change in patients with or without temporomandibular disorder (TMD) symptom was mostly caused by masticatory muscular disorders. This article reports two cases of recovery of occlusal relationship in TMDs patients after stabilization splint therapy. Stabilization splint therapy could be useful in certain conditions of occlusal changes in TMD.

임상가를 위한 특집 2 - 턱관절장애와 관련된 교합변화의 치료 (Treatment of occlusal changes associated with temporomandibular joint disorder)

  • 정재광
    • 대한치과의사협회지
    • /
    • 제51권2호
    • /
    • pp.84-91
    • /
    • 2013
  • Temporomandibular joint disorder(TMJD) was mainly characterized with joint pain, motion limitation, joint sound, resulted from pathologic conditions in temporomandibular joint and around tissue. As temporomandibular joint is one of decisive factors determining the occlusion, disorders in temporomandibular joint may cause the occlusal changes. The causes of occlusal changes related with TMJD can be classified into 2 categories; (1) those related to progression of disorder, 2) those related to treatment of the disorder. The clinical manifestation of occlusal changes depend on their causes and affected site. Therefore, whenever possible, treatment should be directed to the relief of the underlying causes, However, it is not always possible to relieve the underlying conditions. Moreover, some occlusal changes may remain irreversible even after the considerable improvement in clinical symptoms. Regarding the treatment of the permanent occlusal changes, it has been reported that the extensive occlusal treatment including occlusal adjustment, prosthodontic treatment, orthodontic treatment should be applied. Here, we present with a case report of occlusal change caused by the progressive temporomandibular joint disorder, together with introducing the intermaxillary traction appliance as the possible treatment option.

마우스가드의 형태가 운동선수의 체력 및 운동능력에 미치는 영향 (The Effect of Occlusal Condition on Physical Fitness and Motor Capacity in Athletes According to Various Types of Mouthguards)

  • 최수정;정재광;이규복;채원식
    • 구강회복응용과학지
    • /
    • 제29권1호
    • /
    • pp.1-9
    • /
    • 2013
  • 본 연구의 목적은 마우스가드의 착용이 기초 체력 및 운동 능력에 미치는 영향을 밝히는데 있다. 특히 부분피개 마우스가드 착용의 효과를 파악하여 교합의 안정성이 기초 체력 및 운동 능력에 미치는 영향을 밝히고자 한다. 이를 위해 K대학교 체육교육과에 재학 중인 대학생 20명을 대상으로 5가지 교합상태-마우스가드 미착용, 전악피개 마우스가드 착용, 좌우측 편측 마우스가드 착용, 전치부 마우스가드 착용-에서 각각 사이드스텝, 제자리 높이뛰기, 배근력, 악력, 외발서기, 유연성과 같은 기초 체력 및 운동능력을 측정하였다. 본 연구의 결과 전악피개 마우스가드의 착용은 운동능력 측정 항목 중 사이드스텝, 제자리 높이뛰기, 배근력, 악력, 외발서기, 유연성, 전신반응 모두에서 마우스 가드 미착용 시와 비교하여 유의성 있는 차이가 나타나지 않았다. 하지만 부분피개 마우스가드의 착용 시에는 미착용 시에 비해 전신반응이 유의성 있게 향상되었다. 이러한 결과를 통해 전악피개 마우스가드의 착용이 운동능력에 유의한 영향은 없으나 부분피개 마우스가드의 착용은 민첩성 향상에 기여할 수 있는 것으로 사료된다. 뿐만 아니라 교합적인 안정성이 단기적으로는 전신반응의 향상에 긍정적인 효과를 발생시키지 못하는 것으로 판단된다.

Load-bearing capacity of various CAD/CAM monolithic molar crowns under recommended occlusal thickness and reduced occlusal thickness conditions

  • Choi, Sulki;Yoon, Hyung-In;Park, Eun-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권6호
    • /
    • pp.423-431
    • /
    • 2017
  • PURPOSE. The goal of this study was to evaluate the fracture resistances of various monolithic crowns fabricated by computer-aided design and computer-aided manufacturing (CAD/CAM) with different thickness. MATERIALS AND METHODS. Test dies were fabricated as mandibular molar forms with occlusal reductions using CAD/CAM. With different occlusal thickness (1.0 or 1.5 mm), a polymer-infiltrated ceramic network (Enamic, EN), and zirconia-reinforced lithium silicate (Suprinity, SU and Celtra-Duo, CD) were used to fabricate molar crowns. Lithium disilicate (e.max CAD, EM) crowns (occlusal: 1.5 mm) were fabricated as control. Seventy crowns (n=10 per group) were bonded to abutments and stored in water for 24 hours. A universal testing machine was used to apply load to crown until fracture. The fractured specimens were examined with a scanning electron microscopy. RESULTS. The type of ceramics and the occlusal thickness showed a significant interaction. With a recommended thickness (1.5 mm), the SU revealed the mean load similar to the EM, higher compared with those of the EN and CD. The fracture loads in a reduced thickness (1.0 mm) were similar among the SU, CD, and EN. The mean fracture load of the SU and CD enhanced significantly when the occlusal thickness increased, whereas that of the EN did not. CONCLUSION. The fracture loads of monolithic crowns were differently influenced by the changes in occlusal thickness, depending on the type of ceramics. Within the limitations of this study, all the tested crowns withstood the physiological masticatory loads both at the recommended and reduced occlusal thickness.

Acute Malocclusion Related to Posterior Disc Displacement According to Complete Disc Tearing: Two Case Reports

  • Jo-Eun Park
    • Journal of Oral Medicine and Pain
    • /
    • 제49권2호
    • /
    • pp.29-34
    • /
    • 2024
  • Acute malocclusion can occur in conditions related to temporomandibular joint (TMJ) disorders. This report presents two cases of acute malocclusion related to posterior disc displacement according to complete disc tearing. A 65-year-old male and an 88-yearold female presented with TMJ pain and occlusal discrepancies. Clinical examination, computed tomography, and magnetic resonance imaging revealed complete disc tearing and posterior displacement of a partial disc fragment. Dental cast analysis revealed a slight anterior and lateral deviation of the mandible toward the non-affected side; however, clinically, significant occlusal changes were not observed. This was attributed to the displacement of a small disc fragment rather than the entire disc. Including the cases presented, most instances of complete disc tearing responded well to conservative treatment such as pharmacotherapy and physical therapy, resulting in pain alleviation, and residual occlusal changes were tolerable for the patients in their daily activities. However, persistent occlusal changes or severe chewing difficulty may require surgical intervention.

치아 우식증 진단시 필름 방사선사진상과 디지털 방사선영상의 비교:CCD, CMOS, PSP와 film (A comparison of film and 3 digital imaging systems for natural dental caries detection: CCD, CMOS, PSP and film)

  • 한원정
    • Imaging Science in Dentistry
    • /
    • 제34권1호
    • /
    • pp.1-5
    • /
    • 2004
  • Purpose: To evaluate the diagnostic accuracy of occlusal and proximal caries detection using CCD, CMOS, PSP and film system. Materials and Methods : 32 occlusal and 30 proximal tooth surfaces were radiographed under standardized conditions using 3 digital systems; CCD (CDX-2000HQ, Biomedysis Co., Seoul, Korea), CMOS (Schick, Schick Inc., Long Island, USA), PSP (Digora/sup (R)/FMX, Orion Co./Soredex, Helsinki, Finland) and I film system (Kodak Insight, Eastman Kodak, Rochester, USA). 5 observers examined the radiographs for occlusal and proximal caries using a 5-point confidence scale. The presence of caries was validated histologically and radiographically. Diagnostic accuracy was evaluated using ROC curve areas (Az). Results: Analysis using ROC curves revealed the area under each curve which indicated a diagnostic accuracy. For occlusal caries, Kodak Insight film had an Az of 0.765, CCD one of 0.730, CMOS one of 0.742 and PSP one of 0.735. For proximal caries, Kodak Insight film had an Az of 0.833, CCD one of 0.832, CMOS one of 0.828 and PSP one of 0.868. No statistically significant difference was noted between any of the imaging modalities. Conclusion: CCD, CMOS, PSP and film performed equally well in the detection of occlusal and proximal dental caries. CCD, CMOS and PSP-based digital images provided a level of diagnostic performance comparable to Kodak Insight film.

  • PDF

유한요소 분석을 이용한 하중 위치에 따른 구치부 임플란트 국소의치 지지골의 응력 분포 연구 (Finite element analysis of stress distribution on supporting bone of posterior implant partial dentures by loading location)

  • 손성식;김영직;이명곤
    • 대한치과기공학회지
    • /
    • 제29권1호
    • /
    • pp.93-101
    • /
    • 2007
  • The purpose of this study is to evaluate the effect of three different oblique mechanical loading to occlusal surfaces of posterior implant partial dentures on the stress distributions in surrounding bone, using 3-dimensional finite element method. A 3-dimensional finite element model of a posterior implant partial dentures composed of three unit implants, simplified 3 gold alloy crown and supporting bone was developed according to the design of AVANA self tapping implant for this study. Three kinds of surface distributed oblique loads(300 N) are applied to following occlusal surfaces in the three crowns; 1) All occlusal surfaces in the three crown(load of 300 N was shared to three crown), 2) Occlusal surface of centered crown (load of 300 N was applied to a centered crown), 3) Occlusal surface of proximal crown(load of 300 N was applied to a distal proximal crown). In the results, 141 MPa of maximum von Mises stress was calculated at third loading condition and 98 MPa of minimum von Mises stress was calculated at first loading condition. From the results, location and type of occlusive loading conditions are important for the safety of supporting bone.

  • PDF

임시 수복물 중합시 시간과 중합온도가 변연 적합도에 미치는 효과 (EFFECT OF TIME AND TEMPERATURE ON THE MARGINAL FIT OF PROVISIONAL RESIN CROWN DURING POLYMERIZATION)

  • 윤승환;오남식;김일규;오성섭;최진호;김왕식;임영일
    • 대한치과보철학회지
    • /
    • 제39권5호
    • /
    • pp.514-525
    • /
    • 2001
  • The purpose of this study was to compare the marginal fit of provisional restorations by differentiating the removal time and setting temperature during resin polymerization. After mixing autopolymerizing methyl methacrylate resin, the material was placed in a preformed resin shell crown. The crown was seated on a die with 1mm shoulder margin. Crowns were removed after 3, 4, 5, 6 minutes and polymerization was continued under the following conditions : $25^{\circ}C$ air, $30^{\circ}C,\;40^{\circ}C,\;50^{\circ}C,\;60^{\circ}C,\;70^{\circ}C$ water. After polymerization. the crown was sectioned. The marginal & occlusal discrepancies were measured. The mean marginal discrelpancies at 3 minutes, 4 minutes, 5 minutes and 6 minutes of removing time were $96.6{\mu}m.\;84.6{\mu}m,\;86.7{\mu}m$ and $105.6{\mu}m$. The mean occlusal discrepancies at 3 minutes, 4 minutes, 5 minutes and 6 minutes of removing time were $106.7{\mu}m,\;89.3{\mu}m,\;98.6{\mu}m$ and $127.7{\mu}m$. There was significant difference between 4 minutes group and 6 minutes group in occlusal discrepancies. The mean marginal & occlusal discrepancies for crowns polymerized in $25^{\circ}C$ air were $98.2{\mu}m$ and $124.1{\mu}m$. The crowns polymerized in $50^{\circ}C$ water demonstrated the smallest marginal & occlusal. discrepancies. The mean value of marginal & occlusal discrepancies in $50^{\circ}C$ water were $73.1{\mu}m$ and $77.5{\mu}m$. These values were smaller than that of $25^{\circ}C$ air. There were significant differences in the occlusal discrepancies between $25^{\circ}C$ air and water conditions of $50^{\circ}C$ water (${\alpha}=0.05$) but. no significant difference in marginal discrepancies. There was no significant difference in the interaction between time and temperature. 4 minutes waiting time & $50^{\circ}C$ water polymerizing condition produces the best fit at the margin of the provisional crown.

  • PDF

정상인과 체육인의 교합상태에 대한 정상적.정량적 비교 연구 (A QUALITATIVE AND QUANTITATIVE STUDY ON OCCLUSAL CONDITIONS IN HEALTH VOLUNTEERS AND ATHLETES WITH NORMAL OCCLUSION)

  • 장정미;이성복
    • 대한치과보철학회지
    • /
    • 제36권2호
    • /
    • pp.302-322
    • /
    • 1998
  • This study was accompolished to analyze and compare the number and area of the occlusal contact points in healthy volunteers and athletes with normal occlusion. For this study, 15 athletes(13 amles and 2 females with average age 20) and 21 healthy volunteers(14 mles and 7 females with average age 20.09) were selected. The visual display acquired by scanning of occlusal record in maximal intercuspation was converted into 16 gray value image. Then, using computer program(J & Lee Occlusal Analyser), the pixel which was in definite range of the gray value was recognized, and the numbers of recognized pixel were calculated to area. The results were as follows ; 1. The average numbers of total occlusal contact feints were 31.05 in control group, and 34.67 in athlete group. The average area of total occlusal contacts was $100.25mm^2$ in control group, and $127.78mm^2$ in athlete group. 2. In control group, the average numbers of occlusal contact points were revealed in order as follows ; the first molar(8.48), the second molar(8.24), the second premolar(4.71), the lateral incisor(2.90), the first premor(2.43), the central incisor(2.19), and the canine(2.1). The least average in canine(2.1) was similar to the average(2.19) in central incisor and (2.09) in lateral incisor. In athlete group, the average numbers of occlusal contact points were revealed in order as follows ; the first molar(8.97), the second molar(8.47), the second premolar(5.60), the canine(3.80), the lateral incisor(3.33), the first premolar(2.67), and the central incisor(1.93). 3. In control group, the average areas of occlusal contact surface were revealed in order as follows ; the first molar($39.47mm^3$), the second molar($37.54mm^3$), the second premolar($9.54mm^3$) the first premolar($6.18mm^3$), canine($3.49mm^3$), the central incisor($2.76mm^3$), and the lateral incisor($1.28mm^3$). In athlete group, the average areas of occlusal contact surface were revealed in order as follows ; the first molar($44.11mm^3$), the second molar($40.69mm^3$), the second premolar($16.50mm^3$), the first premolar($9.39mm^3$), the canine($5.08mm^3$), the lateral incisor($3.7mm^3$), and the central incisor($2.25mm^3$). 4. With aging in both control and athlete group, there was a decreasing tendancy in average number of occlusal contact point, and was an increasing tendancy in average area of occlusal contact surface. In comparison at each age, both the numbers and area of occlusal contact were greater in athlete group than in control group. It was not significant in the numbers of occlusal contact points beween athlete and control group(p>0.1), but significant in the area of occlusal contact surface(p<0.03). 5. In comparision as to the kind of sports(Gymnastics : 2, Rugby : 3, Soccor : 5, Ice hocky : 5), the numbers of occlusal contact points were the most in ice hocky, and the area of occlusal contact surface was the greatest in gymnastics. With increasing a career in athlete group, there was a decreasing tendancy in average numbers of occlusal contact points and was an increasing tendancy in average area of occlusal contact surface. 6. By T-scan analyzing, the contact numbers on the anterior teeth were greater in control group than in athlete group, and on the posterior teeth were greater in athlete group than in control group. And the results acquired by T-scan were lesser than that caquired by the silicone bite records. It was not significant in the posterior teeth, but significant in the anterior teeth. In T-scan records, the numbers of occlusal contact points on second molar were the greatest, but in the silicone records, the numbers on first molar were the greatest.

  • PDF

지르코니아 단일구조 전부도재관의 지대치 형태에 따른 파절 강도 (Fracture Strength Analysis of Monolithic Zirconia Ceramic by Abutment Shape)

  • 김원영;홍민호
    • 대한치과기공학회지
    • /
    • 제36권4호
    • /
    • pp.231-237
    • /
    • 2014
  • Purpose: This study was performed fracture strength test by conducted change of abutment and coping shape for suggesting monolithic all ceramic crown which has thin thickness and superior strength of the occlusal surface. Methods: The specimens on the four kinds abutment was made according to thickness of occlusal surface and angle of axis surface. And All ceramic coping specimens of 6 different kinds was made by the CAD/CAM Method. Compression strength test using the UTM and the verification of compression-stress situation using the 3D finite element method were conducted under optimum conditions. Results: 516C specimen was showed the strongest compression-fracture strength, followed by 516FR, 516F45, specimens. Did not show significant differences between 516FR and 516F45. 516C of the universal testing machine the specimen's surface that are within the vertical load is small, finite element method of a uniformly distributed load, so the value received suggests otherwise. Conclusion: In conclusion, abutments of monolithic ziconia ceramic when having a same thickness of the occlusal, as the angle of occlusal edge is small, the stress is well dispersed and it can endure well in the fracture.