• Title/Summary/Keyword: observed speed

Search Result 2,308, Processing Time 0.032 seconds

The Effect of Gait Training of Progressive Increasing in Body Weight Support and Gait Speed on Stroke Patients (점진적 체중지지와 보행속도 증가 훈련이 뇌졸중 환자의 보행에 미치는 효과)

  • Kim, Sung-Hoon;Choi, Jong-Duk
    • The Journal of Korean Physical Therapy
    • /
    • v.25 no.5
    • /
    • pp.252-259
    • /
    • 2013
  • Purpose: The aim of this study was to evaluate the effect of progressive body weight decrease combined with increasing level of overground walking speed training for patients with chronic stroke. Methods: Eighteen subjects with chronic stroke were composed of the control group (5% body weight support combined with increasing speed training) and the experimental group (progressive body weight decrease with increasing speed training); three sets, three times per week over a period of four weeks. Results: Significant differences in terms of comfortable gait speed (CGS) and the rate of change of CGS were observed between the control and experimental groups (p<0.05). However, no significant difference in the dynamic gait index was observed between the control and experimental groups (p>0.05). A significant difference in the 6 minute walking test (6MWT) was observed for the experimental group, and a significant difference in the rate of change for the 6MWT was observed between the control and experimental groups (p<0.05). Conclusion: The progressive body weight decrease combined with increasing in level of overground walking speed training may be a better and more effective method for community walking and reintegration.

EVALUATION OF MARINE SURFACE WINDS OBSERVED BY ACTIVE AND PASSIVE MICROWAVE SENSORS ON ADEOS-II

  • Ebuchi, Naoto
    • Proceedings of the KSRS Conference
    • /
    • v.1
    • /
    • pp.146-149
    • /
    • 2006
  • Marine surface winds observed by two microwave sensors, SeaWinds and Advanced Microwave Scanning Radiometer (AMSR), on the Advanced Earth Observing Satellite-II (ADEOS-II) are evaluated by comparison with off-shore moored buoy observations. The wind speed and direction observed by SeaWinds are in good agreement with buoy data with root-mean-squared (rms) differences of approximately 1 m $s^{-1}$ and $20^{\circ}$, respectively. No systematic biases depending on wind speed or cross-track wind vector cell location are discernible. The effects of oceanographic and atmospheric environments on the scatterometry are negligible. The wind speed observed by AMSR also exhibited reasonable agreement with the buoy data in general with rms difference of 1.2 m $s^{-1}$. Systematic bias which was observed in earlier versions of the AMSR winds has been removed by algorithm refinements. Intercomparison of wind speeds globally observed by SeaWinds and AMSR on the same orbits also shows good agreements. Global wind speed histograms of the SeaWinds data and European Centre for Medium-range Weather Forecasts (ECMWF) analyses agree precisely with each other, while that of the AMSR wind shows slight deviation from them.

  • PDF

Effect of Electric Fields on the Propagation Speed of Tribrachial Flames in Coflow Jets (동축류 제트에서 삼지화염 전파의 전기장 효과에 대한 실험적 연구)

  • Won, Sang-Hee;Chung, Suk-Ho;Cha, Min-Suk
    • 한국연소학회:학술대회논문집
    • /
    • 2006.10a
    • /
    • pp.220-226
    • /
    • 2006
  • The effect of electric fields on the propagation speed of tribrachial flames has been investigated in a coflow jet by observing the transient flame propagation behavior after ignition. Without having electric fields, the propagation speed of tribrachial flame edges showed a typical behavior by having an inverse proportionality to the mixture fraction gradient at the flame edge. The behavior of flame propagation with the electric fields was investigated by applying high voltage to the central fuel nozzle and the enhancement of propagation speed has been observed by varying the applied voltage and frequency for AC electric fields. The propagation speed of tribrachial flame was also investigated by applying negative and positive DC voltages to the nozzle and similar improvements of the propagation speed were also observed. The propagation speeds of tribrachial flames in both the AC and DC electric fields were correlated well with the electric field intensity, defined by the electric voltage divided by the distance between the nozzle electrode and the edge of tribrachial flames.

  • PDF

A study on bulk deposition flux of dustfall and insoluble components by the wind intensity in Busan, Korea (바람의 강도에 따른 강하먼지와 불용성 성분의 조성특성)

  • 황용식;김유근;박종길;문덕환
    • Journal of Environmental Science International
    • /
    • v.11 no.7
    • /
    • pp.651-662
    • /
    • 2002
  • Weather elements were observed by the AWS (Automatic Weather System) and dustfall particles were collected by the modified American dust jar (wide inlet bottle type) at 4 sampling sites in Busan area from March. 1999 to February, 2000. Thirteen chemical species (Al, Ca, Cd, Cr, Cu, Fe, K, Mg, Mn, Ni, Pb, Si, and Zn) were analyzed by AAS and ICP. The purposes of this study were to estimate qualitatively various bulk deposition flux of dustfall and insoluble components by applying regional and seasonal wind intensity. Frequency of wind speed were found in order of low(1-3m/s), very low(<1m/s), medium(3-8m/s) and high(>8m/s), and annual mean had higher range at low(1-3m/s) for 56.3%. Strong negative linear correlation were observed between dustfall and wind direction (northeastern and eastern), but strong positive linear correlation were observed between dustfall and wind direction (western and northwestern) at industrial, commercial and coastal zone(p<0.05). While a negative correlation were observed between wind speed frequency of very low(<1 m/s) and dustfall, and positive correlation were observed between wind speed frequency of low(1-3m/s) and dustfall in coastal zone(p<0.05). The correlation coefficient was observed 0.556 between wind speed frequency of low(1-3m/s) and Ni by commercial zone(p<0.05). The correlation coeffcient show well-defined insoluble trace metals (Al, Ca, Cr, Cu, Fe, Pb, and Zn) and wind speed frequency of low(1-3m/s) at coastal zone, which was found significant difference(p<0.01).

Propagation Characteristics of Turbulent Premixed Flames in Nearly Isotropic Turbulent Flows (등방성 난류 유동장내 예혼합 화염의 자유 전파속도에 관한 실험적 연구)

  • Lee, S.J.;Noh, D.S.
    • 한국연소학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.35-41
    • /
    • 2003
  • Propagation speeds of turbulent premixed flames have been measured in a pulsed-flame flow reactor which generates flames propagating in nearly isotropic turbulent flow field with U'/$S_L$ ranging from 1.2 to 5.3. The measurement involved a high-speed digital imaging at 1000 frames/second to capture the flame propagation motion. In addition to the flame speed measurements, flame perimeter ratio was measured for comparison. The observed flame propagation speed is high ranging from 5 to 20 times the laminar flame speed for the range of U'/$S_L$. The flames observed at extreme equivalence ratios exhibit intermittent propagation in that only a small fraction of ignited flame kernel resulted in full propagation of the flame. Also, at low equivalence ratios the flame speed decreased substantially even at high turbulence intensities.

  • PDF

Characteristics of Recent Occurrence Frequency of Asian dust over the Source Regions - Analysis of the dust Occurrences since 2002 (최근의 황사 발원지에서의 먼지 발생 특성-2002년 이후 먼지발생 경향 분석)

  • Lee, Jong-Jae;Kim, Cheol-Hee
    • Atmosphere
    • /
    • v.18 no.4
    • /
    • pp.493-506
    • /
    • 2008
  • In order to examine the variational features of Asian dust outbreak in recent years, observed WMO synop data were employed for the period from 1996 to 2007. We first divided Asian dust source regions into four subregions; 1) Taklamakan, 2) Gobi, 3) Inner Mongolia-Manchuria and 4) Loess, and the meteorogical variables such as wind speed, precipitation and threshold wind speed observed during the Asian dust outbreak period were compared with those during non-Asian dust period. The results showed that temporal variation of occurrence frequency of dust outbreak had a strong positive correlation with the frequency of strong wind speed and low precipitation in each of the 4 source regions. Spatial distributions of frequency of dust occurrence after 2002 showed increasing trend in Gobi and Inner Mongolia-Manchuria but decreasing trend in Loess region. This is showing a shift in main source region toward Northwest, especially since 2003.

An Application of the Probability Plotting Positions for the Ln­least Method for Estimating the Parameters of Weibull Wind Speed Distribution (와이블 풍속 분포 파라미터 추정을 위한 Ln­least 방법의 확률도시위치 적용)

  • Kang, Dong-Bum;Ko, Kyung-Nam
    • Journal of the Korean Solar Energy Society
    • /
    • v.38 no.5
    • /
    • pp.11-25
    • /
    • 2018
  • The Ln-least method is commonly used to estimate the Weibull parameters from the observed wind speed data. In previous studies, the bin method has been used to calculate the cumulative frequency distribution for the Ln-least method. The purpose of this study is to obtain better performance in the Ln-least method by applying probability plotting position(PPP) instead of the bin method. Two types of the wind speed data were used for the analysis. One was the observed wind speed data taken from three sites with different topographical conditions. The other was the virtual wind speed data which were statistically generated by a random variable with known Weibull parameters. Also, ten types of PPP formulas were applied which were Hazen, California, Weibull, Blom, Gringorten, Chegodayev, Cunnane, Tukey, Beard and Median. In addition, in order to suggest the most suitable PPP formula for estimating Weibull parameters, two accuracy tests, the root mean square error(RMSE) and $R^2$ tests, were performed. As a result, all of PPPs showed better performances than the bin method and the best PPP was the Hazen formula. In the RMSE test, compared with the bin method, the Hazen formula increased estimation performance by 38.2% for the observed wind speed data and by 37.0% for the virtual wind speed data. For the $R^2$ test, the Hazen formula improved the performance by 1.2% and 2.7%, respectively. In addition, the performance of the PPP depended on the frequency of low wind speeds and wind speed variability.

A study on the relationship between rubbing scratches on an alignment film and rubbing cloths using a high-speed camera

  • Inoue, Y.;Kuramoto, Y.;Hattori, M.;Adachi, M.;Kimura, M.;Akahane, T.
    • Journal of Information Display
    • /
    • v.12 no.3
    • /
    • pp.125-128
    • /
    • 2011
  • Alignment failure sometimes occurs during the rubbing process because the rubbing cloth comes in direct contacts with the surface of the alignment film. A number of researches observed and evaluated the surface of the alignment film after the rubbing process had been reported. The real-time rubbing process has not been observed directly yet, though. In this study, the movement of the piles of the rubbing cloth during the rubbing process was observed with a high-speed camera. Furthermore, the relationship between the rubbing scratch on the alignment films and the movement of the pile was investigated. It was found that the movement of the pile affected the rubbing scratches.

Diurnal Variations of O3 and NO2 Concentrations in an Urban Park in Summer: Effects of Air Temperature and Wind Speed (여름철 도심 공원의 O3과 NO2 농도의 일변화: 기온과 풍속의 영향)

  • Han, Beom-Soon;Kwak, Kyung-Hwan;Baik, Jong-Jin
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.32 no.5
    • /
    • pp.536-546
    • /
    • 2016
  • The diurnal variations of $O_3$ and $NO_2$ in an urban park and the effects of air temperature and wind speed on the diurnal variations are investigated. $O_3$ and $NO_2$ concentrations were observed at a site in an urban park of Seoul from 27 July 2015 to 9 August 2015. The $O_3$ and $NO_2$ concentrations observed in the urban park are compared to those observed at the Gangnam air quality monitoring station (AQMS). The $O_3$ concentration is higher in the urban park than at the Gangnam AQMS in the daytime because the amount of $O_3$ dissociated by NO is smaller as well as partly because the amount of $O_3$ produced in the oxidation process of biogenic volatile organic compounds (VOCs) is larger in the urban park than at the Gangnam AQMS. The $NO_2$ concentration is lower in the urban park than at the Gangnam AQMS during day and night because the observation site in the urban park is relatively far from roads where $NO_x$ is freshly emitted from vehicles. The difference in $NO_2$ concentration is larger in the daytime than in the nighttime. To examine the effects of air temperature and wind speed on the diurnal variations of $O_3$ and $NO_2$, the observed $O_3$ and $NO_2$ concentrations are classified into high or low air temperature and high or low wind speed days. The high $O_3$ and $NO_2$ concentrations in the daytime appear for the high air temperature and low wind speed days. This is because the daytime photochemical processes are favorable when the air temperature is high and the wind speed is low. The scatter plots of the daytime maximum $O_3$ and minimum $NO_2$ concentrations versus the daytime averages of air temperature and wind speed show that the daytime maximum $O_3$ and minimum $NO_2$ concentrations tend to increase as the air temperature increases or the wind speed decreases. The daytime maximum $O_3$ concentration is more sensitive to the changes in air temperature and wind speed in the urban park than at the Gangnam AQMS.

Development of Guidelines for Installing Speed Control Humps (차량과속방지턱의 설치기준 개발에 관한 연구)

  • 문무창;장명순
    • Journal of Korean Society of Transportation
    • /
    • v.12 no.1
    • /
    • pp.137-149
    • /
    • 1994
  • The objective of study is to evaluate the effect of speed control hump on traffic operation and accidents. Three sites were investigated for the change of traffic accidents before and after the hump installation. Vehicle speeds approaching the hump were also analyzed. The study revealed that not only the number of traffic accidents but also the accident severity were significantly reduced by the installation of hump. Further, different types of traffic accidents with lower severity were observed after the hump installation. For the effect of speed reduction by hump, it was found that the speeds observed at 15m upstream of hump were in the range of 36~50 percent of approaching speeds which were not affected by (ie, without) the hump. Economic analysis of hump installation showed the benefit-cost ratio of 4.3 and 11.2 at two sites. Further analysis revealed that the benefit by the accident reduction exceeds the cost by speed reduction and installation capital if AADT is below 43,150 vehicles on two lane highways. It is recommended from the study that humps should be considered on two lane highways of high accident locations for excessive speeds to reduce traffic accidents and severity.

  • PDF