• Title/Summary/Keyword: object scanning

Search Result 256, Processing Time 0.029 seconds

A Study on Stereo Visualization of the X-ray Scanned Image Based on Volume Reconstruction (볼륨기반 X-선 스캔영상의 3차원 형상화 연구)

  • Lee, Nam-Ho;Park, Soon-Yong;Hwang, Young-Gwan;Park, Jong-Won;Lim, Yong-Gon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.7
    • /
    • pp.1583-1590
    • /
    • 2011
  • As the existing radiation scanning systems use 2-dimensional radiation scanned images, the low accuracy has been pointed out as a problem of it. This research analyzes the applicability of the stereo image processing technique to X-ray scanned images. Two 2-dimensional radiation images which have different disparity values are acquired from a newly designed stereo image acquisition system which has one additional line sensor to the conventional system. Using a matching algorithm the 3D reconstruction process which find the correspondence between the images is progressed. As the radiation image is just a density information of the scanned object, the direct application of the general stereo image processing techniques to it is inefficient. To overcome this limitation of a stereo image processing in radiation area, we reconstruct 3-D shapes of the edges of the objects. Also, we proposed a new volume based 3D reconstruction algorithm. Experimental results show the proposed new volume based reconstruction technique can provide more efficient visualization for cargo inspection. The proposed technique can be used for such objects which CT or MRI cannot inspect due to restricted scan environment.

Autophagy-related protein LC3 and Beclin-1 in the first trimester of pregnancy

  • Chifenti, Barbara;Locci, Maria Teresa;Lazzeri, Gloria;Guagnozzi, Mariangela;Dinucci, Dino;Chiellini, Federica;Filice, Maria Elena;Salerno, Maria Giovanna;Battini, Lorella
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.40 no.1
    • /
    • pp.33-37
    • /
    • 2013
  • Autophagy is a degradation process that acts in response to environmental stressors. Recently, autophagy has been detected in normal term, preeclamptic and intrauterine growth-restricted placentas. The object of this work was to investigate the presence of autophagy in first trimester voluntary interruption of pregnancy placental villi by the expression of autophagy-related proteins, light chain 3 (LC3), and Beclin-1. In first trimester placental villi laser scanning confocal microscopy (LSCM) analysis revealed LC3 and Beclin-1 immunoreactivity prevalently located in villous cytotrophoblasts. Using LSCM, LC3, and Beclin-1 were localized to the cytoplasm of the trophoblast layer in human full-term placentas. Beclin-1 expression and LC3 activation were confirmed by western blotting. These data emphasize that autophagy activation is different among cytotrophoblasts and syncytiotrophoblasts depending on the gestational age and thus we speculate that autophagy might play a prosurvival role throughout human pregnancy.

Preparation and Evaluation of Non-Crystalline Cefuroxime Axetil Solid Dispersion (비결정성 세푸록심 악세틸 고체분산체의 제조 및 평가)

  • Woo, Jong-Soo;Chang, Hee-Chul;Lee, Chang-Hyun
    • Journal of Pharmaceutical Investigation
    • /
    • v.32 no.2
    • /
    • pp.73-80
    • /
    • 2002
  • Cefuroxime axetil is a cephalosporin antibiotic having a high activity against a wide spectrum of Grampositive and Gram-negative microorganisms. It is a cephalosporin antibiotic which exist as 2 diastereoisomers: diastereoisomer A and B. It shows polymorphism of three forms: a crystalline form having a melting point of about $180^{\circ}C$, a substantially amorphous form having a high melting point of about $135^{\circ}C$ and a substantially amorphous form having a low melting point of about 70^{\circ}C$. The crystalline form of cefuroxime axetil is slightly soluble in water because diastereoisomer A has lower solubility than B in water. Substantially amorphous form of which there are no difference in solubility between diastereoisomer A and B has better solubility than crystalline form, but it forms a thicker gel than crystalline form upon contact with an aqueous medium. Based on this reason, cefuroxime axetil is not readily absorbable in the gastrointestinal tract, rendering its bioavailability on oral administration very low. The object of this study was to develop an improved non-crystalline cefuroxime axetil composition having a high physicochemical stability and bioavailability. A non-crystalline cefuroxime axetil solid dispersant showing no peak on a Differential Scanning Calorimetry (DSC) scan is prepared by dissolving cefuroxime axetil and a surfactant in an organic solvent; suspending a water-insoluble inorganic carrier in the resulting solution; and spray drying the resulting suspension to remove the organic solvent, said solid dispersant having an enhanced dissolution and stability of cefuroxime axetil and being useful for the preparation of a pharmaceutical composition for oral administration. Tablet was formulated with this cefuroxime axetil solid dispersant, disintegrants and other ingredients. It disintegrated and dissolved easily and dynamically in dissolution medium, so showed a good dissolution profile.

Acceptance Test and Clinical Commissioning of CT Simulator

  • An, Hyun Joon;Son, Jaeman;Jin, Hyeongmin;Sung, Jiwon;Chun, Minsoo
    • Progress in Medical Physics
    • /
    • v.30 no.4
    • /
    • pp.160-166
    • /
    • 2019
  • This study examined the clinical use of two newly installed computed tomography (CT) simulators in the Department of Radiation Oncology. The accreditation procedure was performed by the Korean Institute for Accreditation of Medical Imaging. An Xi R/F dosimeter was used to measure the CT dose index for each plug of the CT dose index phantom. Image qualities such as the Hounsfield unit (HU) value of water, noise level, homogeneity, existence of artifacts, spatial resolution, contrast, and slice thickness were evaluated by scanning a CT performance phantom. All test items were evaluated as to whether they were within the required tolerance level. CT calibration curves-the relationship between CT number and relative electron density-were obtained for dose calculations in the treatment planning system. The positional accuracy of the lasers was also evaluated. The volume CT dose indices for the head phantom were 22.26 mGy and 23.70 mGy, and those for body phantom were 12.30 mGy and 12.99 mGy for the first and second CT simulators, respectively. HU accuracy, noise, and homogeneity for the first CT simulator were -0.2 HU, 4.9 HU, and 0.69 HU, respectively, while those for second CT simulator were 1.9 HU, 4.9 HU, and 0.70 HU, respectively. Five air-filled holes with a diameter of 1.00 mm were used for assessment of spatial resolution and a low contrast object with a diameter of 6.4 mm was clearly discernible by both CT scanners. Both CT simulators exhibited comparable performance and are acceptable for clinical use.

Shear bond strength of composite resin to high performance polymer PEKK according to surface treatments and bonding materials

  • Lee, Ki-Sun;Shin, Myoung-Sik;Lee, Jeong-Yol;Ryu, Jae-Jun;Shin, Sang-Wan
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.5
    • /
    • pp.350-357
    • /
    • 2017
  • PURPOSE. The object of the present study was to evaluate the shear bonding strength of composite to PEKK by applying several methods of surface treatment associated with various bonding materials. MATERIALS AND METHODS. One hundred and fifty PEKK specimens were assigned randomly to fifteen groups (n = 10) with the combination of three different surface treatments (95% sulfuric acid etching, airborne abrasion with $50{\mu}m$ alumina, and airborne abrasion with $110{\mu}m$ silica-coating alumina) and five different bonding materials (Luxatemp Glaze & Bond, Visio.link, All-Bond Universal, Single Bond Universal, and Monobond Plus with Heliobond). After surface treatment, surface roughness and contact angles were examined. Topography modifications after surface treatment were assessed with scanning electron microscopy. Resin composite was mounted on each specimen and then subjected to shear bond strength (SBS) test. SBS data were analyzed statistically using two-way ANOVA, and post-hoc Tukey's test (P<.05). RESULTS. Regardless of bonding materials, mechanical surface treatment groups yielded significantly higher shear bonding strength values than chemical surface treatment groups. Unlike other adhesives, MDP and silane containing self-etching universal adhesive (Single Bond Universal) showed an effective shear bonding strength regardless of surface treatment method. CONCLUSION. Mechanical surface treatment behaves better in terms of PEKK bonding. In addition, self-etching universal adhesive (Single Bond Universal) can be an alternative bonding material to PEKK irrespective of surface treatment method.

A New Moving Mobile Base Station (MMBS) Scheme for Low Power RMIMS Wireless System (PARTI: MMBS general issues, clystering and signalling Procedures) (저전력 RMIMS 무선 터미널을 위한 새로운 움직이는 이동 기지국 시스템 구조 (1부 : MMBS 일반사항, 클러스터링 및 신호절차))

  • 박수열;고윤호;유상조;김성대
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.12B
    • /
    • pp.2298-2319
    • /
    • 1999
  • In this paper, we propose a new moving mobile base station (MMBS) scheme for very low power and micro-size RMIMS (radio-interfaced micro information monitoring system) terminals. RMIMS terminals can be used in various application service areas such as pollution monitoring, environment surveillance, traffic monitoring, emergency monitoring (e.g., building, bridge, railroad breakdown), security monitoring (e.g., theft, alarm) and military application. For these applications based on wireless transmission technologies, sensor type RMIMS terminals must satisfy low cost and low power design (e.g., solar power, life limited battery) requirement. In RMIMS terminal design, this low power requirement limits transmission range of uplink or reverse link and means small cell size. Also these applications using RMIMS terminals may have a little bit non real-time traffic characteristic and low scattering density in service area.

  • PDF

A Study on Optimized Mapping Environment for Real-time Spatial Mapping of HoloLens

  • Hwang, Leehwan;Lee, Jaehyun;Hafeez, Jahanzeb;Kang, Jinwook;Lee, Seunghyun;Kwon, Soonchul
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.9 no.3
    • /
    • pp.1-8
    • /
    • 2017
  • Recently, the development of the head mounted display (HMD) device has attracted a great deal of attention to the actual contents. Especially, Augmented Reality (AR), which is a mixture of actual information and virtual world information, is focused on. AR HMD is able to interact by arranging virtual objects in real space through spatial recognition using depth camera. In order to naturally mix virtual space with real space, it is necessary to develop a technology for realizing spatial mapping information with high accuracy. The purpose of this paper is to evaluate the optimal configuration of augmented reality application program by realizing accurate spatial mapping information when mapping a real space and an object placement environment using HoloLens. To do this, we changed the spatial mapping information in real space to three levels, which are the number of meshes used in cubic meters to scan step by step. After that, it was compared with the 3D model obtained by changing the actual space and mesh number. Experimental result shows that the higher the number of meshes used in cubic meters, the higher the accuracy between real space and spatial mapping. This paper is expected to be applied to augmented reality application programs that require scanning of highly mapped spatial mapping information.

Development of Speed Measurement Accuracy Using Double Loop Detectors (2중 루프검지기 속도측정 정확도 개선 알고리즘 개발)

  • 강정규
    • Journal of Korean Society of Transportation
    • /
    • v.20 no.5
    • /
    • pp.163-174
    • /
    • 2002
  • Speeding has been reported as one of the major causes for fatal traffic accidents in Korea. The resolution against this dangerous speeding comes to make the automated speed enforcement system an enforcement tool. The speed detection device, which measures speeds of each incoming vehicles using double loop sensors, requires high accuracy. The object of this study is to develop an accurate speed measurement algorithm using double loop detectors. Some important findings are summarized as follows: 1) It was found that speed measurement errors are caused by scanning rate, distance of two loops, irregular vehicle trajectories, multiple vehicles in detection zone. 2) A proposed algorithm using two signal set proved to reduce variance as well as mean of speed measurement. 3) A proposed filtering algorithm was effective to filter irregular driving vehicles and multiple vehicles in detection zone. A comprehensive field test of developed algorithm resulted in significant improvement of speed measurement accuracy.

Image Measurement and Processing using Near-Range Passive Millimeter-wave Imaging System (근거리 수동 밀리미터파 이미징 시스템을 이용한 영상 측정과 영상처리)

  • Jung, Kyung Kwon;Yoon, Jin-Seob;Chae, Yeon-Sik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.8
    • /
    • pp.159-165
    • /
    • 2015
  • In this paper, we designed and tested of the passive millimeter-wave imaging system in near range. The proposed passive millimeter-wave imaging system consists two parts. The first part is a 94 GHz band millimeter imaging sensor which is coupled to an antenna, two LNAs, and a diode detector. The second part is a control unit. The control unit is consists of the 2-axes Cartesian robot, the data acquisition (DAQ), and imaging program. The 2-axes Cartesian robot should be able to scan a 2-D image of the metalic tools, IC card and plastic objects, with a raster scanning method. The passive millimeter-wave image of $20{\times}20$ pixels is acquired within less than 60s, and is immediately displayed and stored for post processing.In order to improve the image quality, interpolation methods are applied.

A Study on Conservation Treatment for Excavated Carbonization Wooden Object : Comparative Experiment on the PEG Method and Sugar Alcohol Method (출토 탄화 목제유물의 보존처리 : PEG법과 당알코올법 실험비교)

  • Lee, Hyun-Hye
    • Journal of Conservation Science
    • /
    • v.24
    • /
    • pp.57-66
    • /
    • 2008
  • It is reported that excavated carbonized wooden objects tend to have more peeling and deformation stemming from the coexisting of different types of parts of objects. However, there is little research results on this. In this experiment, the sugar alcohol method was used and then compared with the results of the PEG4000 method which widely uses. This research targets: prediction of strength by weight increase, investigation of the dimensional stabilization effects by measuring the rate of shrinkage change, condition of drug penetration and change of wood texture by using a scanning electron microscope. As the results, the PEG4000 method needs a phased approach over 80% impregnation. On the other hand, the S A method remains steady from over 40% impregnation. The Deformation of carbonized wooden objects used in this experiment is considered as the phenomenon by shrinkage of non-carbonized parts. The PEG4000 method is verified the shrinkage in the samples treated with 20%, 40% and 60%; the S A method is verified the shrinkage in the samples treated with 20%.

  • PDF