• Title/Summary/Keyword: nyquist frequency

Search Result 125, Processing Time 0.024 seconds

Real-Time Implementation of Active Classification Using Cumulative Processing (누적처리기법을 이용한 능동표적식별 시스템의 실시간 구현)

  • Park, Gyu-Tae;Bae, Eun-Hyon;Lee, Kyun-Kyung
    • The Journal of the Acoustical Society of Korea
    • /
    • v.26 no.2
    • /
    • pp.87-94
    • /
    • 2007
  • In active sonar system, aspect angle and length of a target can be estimated by calculating the cross-correlation between left and right split-beams of a LFM(Linear Frequency Modulated) signal. However, high-resolution performances in bearing and range are required to estimate the information of a remote target. Because a certain higher sampling frequency than the Nyquist sampling frequency is required in this performance, an over-sampling process through interpolation method should be required. However, real-time implementation of split-beam processing with over-sampled split-beam outputs on a COTS(commercial off-the-shelf) DSP platform limits its performance because of given throughput and memory capacity. This paper proposes a cumulative processing algorithm for split-beam processing to solve the problems. The performance of the proposed method was verified through some simulation tests. Also, the proposed method was implemented as a real-time system using an ADSP-TS101.

A frequency domain adaptive PID controller based on non-parametric plant model representation

  • Egashira, Toyokazu;Iwai, Zenta;Hino, Mitsushi;Takeyama, Yoshikazu;Ono, Taisuke
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10a
    • /
    • pp.165-168
    • /
    • 1996
  • In this paper, we propose a design method of PID adaptive controller based on frequency domain analysis. The method is based on the estimation of a nonparametric process model in the frequency domain and the determination of the PID controller parameters by achieving partial model matching so as to minimize a performance function concerning to relative model error between the loop transfer function of the control system and the desired system. In the design method the process is represented only by a discrete set of points on the Nyquist curve of the process. Therefore it is not necessary to estimate a full order parameterized process model.

  • PDF

Design of DC-free and minimum bandwidth binary line codes by look-up table (조견표를 이용한 무직류 및 최소대역폭 이진선로부호의 설계)

  • 장창기;주언경
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.10
    • /
    • pp.2653-2659
    • /
    • 1996
  • In this paper, DC-free and minimum bandwidth binary line codes with look-up table are proposed and their performances are analyzed. As results of performance analysis, the proposed codes are shown to have spectral nulls at DC and Nyquist frequency. Among the proposed codes, binary line codes of which both codeword digital sum and alternating digital sum are zero have lower code rate but better spectral characteristics. Furthermore, binary line codes which consist of all codewords including those with nonzero digital sum and alternating digital sum have worese spectral characteristics but higher code rate.

  • PDF

Hydrodynamic and Oxygen Effects on Corrosion of Cobalt in Borate Buffer Solution (Borate 완충용액에서 코발트의 부식에 대한 대류와 산소의 영향)

  • Kim, Younkyoo
    • Journal of the Korean Chemical Society
    • /
    • v.58 no.5
    • /
    • pp.437-444
    • /
    • 2014
  • The electrochemical corrosion and passivation of Co-RDE in borate buffer solution was studied by Potentiodynamic and electrochemical impedance spectroscopy. The mechanisms of both the active dissolution and passivation of cobalt and the hydrogen evolution in reduction reaction were hypothetically established while utilizing the Tafel slope, the rotation speed of Co-RDE, impedance data and the pH dependence of corrosion potential. Based on the EIS data, an equivalent circuit was suggested. In addition, the electrochemical parameters for specific anodic dissolution regions were carefully measured. An induction loop in Nyquist plot measured at the open-circuit potential was observed in the low frequency, and this could be attributed to the adsorption-desorption behavior in the corrosion process.

The Effect of Oleic Acid and Propylene Glycol on the Electrical Properties of Skin (올레인산 및 프로필렌글리콜이 피부의 전기적 성질에 미치는 영향)

  • Oh, Seaung-Youl;Guy, Richard H.
    • Journal of Pharmaceutical Investigation
    • /
    • v.24 no.4
    • /
    • pp.281-287
    • /
    • 1994
  • The effects of oleic acid, propylene glycol and 5% (w/w) oleic acid in propylene glycol on the electrical properties of hairless mouse skin were studied and the results were compared. The complex electrical impedance was measured as a function of frequency, and resistance and capacitance were determined from the Nyquist plot. Immediately after the treatment with oleic acid, resistance was 145% of the pretreatment value. However it decreased with time and, after 20 hours, it was about 25% of its pretreatment value. Capacitance increased; immediately after the treatment, it was about 125% of pretreatment value and it seemed to increase slowly with time. When the skin was treated with propylene glycol, resistance decreased about 5O% and capacitance increased about 65%. Similar results were observed when the skin was treated with 5% (w/w) oleic acid in propylene glycol, except that the magnitude of resistance drop was much larger. Oleic acid acted synergistically with propylene glycol. Together with the flux data in the literature, the results obtained in this work indicate that electrical resistance is closely related to the permeability of drug molecules through the skin. The results are discussed in terms of the mechanism of action of these penetration enhancers. Overall, this work provided further mechanistic insight into the role of SC lipids in skin resistance and capacitance.

  • PDF

Effect of Enhancers on the Electrical Properties of Skin: The Effect of Azone and Ethanol

  • Oh, Seaung-Youl;Guy, Richard H.
    • Journal of Pharmaceutical Investigation
    • /
    • v.24 no.3
    • /
    • pp.41-47
    • /
    • 1994
  • The effect of Azone and ethanol on the electrical properties of human and hairless mouse skin was studied and the results were compared. The complex electrical impedance was measured as a function of frequency, and resistance and capacitance were determined from Nyquist plot. After the treatment of human-heat separated epidermis with Azone, contrary to the expectation, resistance increased about 60% and it did not change with time. Capacitance also increased; immediately after the treatment, it was about 110% of pretreatment value and it increased further with time. On the other hand, when hairless mouse skin was treated with Azone, marked changes occured; resistance fell almost to the value of bathing medium itself and capacitance increased to about 200% of its pretreatment value. Similar result were obtained when hairless mouse skin was treated with 100% ethanol. The results suggest that there are differences in the strength of barrier properties of stratum corneum (SC) between human and hairless mouse skin. Overall, the results provide further mechanistic insight into ion conduction through the skin and into the role of SC lipids in skin capacitance.

  • PDF

Investigation of the existing thermal noise theories for field-effect transistors using the monte-carlo method and the generalized ramo-shockley theorem (Monte-carlo 방법과 일반화된 ramo-shockley 정리를 통한 FET 열잡음 이론의 검증)

  • 모경구;민홍식;박영준
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.33A no.10
    • /
    • pp.107-114
    • /
    • 1996
  • Monte carlo method is especially a useful method for the analysis of thermal noise of semiconductor devices since the time dependence of microscopic details is simulated directly. Recently, a mthod for the calculation of the instantaneous currents of 2-dimensional devices, which is numerically more accurate than the conventional method, has been proposed using the generalized ramo-shockley theorem. Using this mehtod we investage the validity of the existing thermal noise theories of field-effect transistors. First, the 1-dimensional analysis of thermal noise theories of field-effect transistors. First, the 1-dimensional analysis of thermal noise theories of field-effect transistors. First, the 1-dimensional analysis of thermal noise using ramo-shockley theorem is shown to be applicable to 2 dimensional devices if the frequency of interest is low enough. The correlation between electrons in different regions of th echannel is shown not to be negligible. And we also obtian the spatial map of the noise in the channel region. By doing so, we show that the steady state nyquist theorem is the correct theory rather than the theory by van der ziel et.al.

  • PDF

Symbol Synchronization of OFDM Systems using Signs of Preamble Signals (훈련신호의 부호를 사용한 OFDM 시스템의 심볼동기)

  • 황진권
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.5A
    • /
    • pp.502-513
    • /
    • 2004
  • This paper proposes a symbol synchronization method in the IEEE 802.11a wireless OPDM system, which uses only signs of the in-phase and the quadrature signals in the short preamble. The short preamble is sampled with 2 tines of Nyquist sampling rate and both of the autocorrelation and the cross-relation are used in the proposed method. This method has some advantages that the ACG (Automatic Gain Control) can be processed concurrently during the short preamble and its implementation is not much complicated. The proposed symbol synchronization method is verified through simulations on frequency offset, multi-path and white Gaussian noise.

The Analysis of Stability in a Steam Generator (증기발생기의 안정성 분석)

  • Shin Whan Kim;Goon Cherl Park
    • Nuclear Engineering and Technology
    • /
    • v.17 no.4
    • /
    • pp.279-289
    • /
    • 1985
  • The purpose of this paper is to investigate the density-wave oscillation type instability in the recirculating loop of U-tube steam generator (UTSG). The perturbed and nodalized conservations equations based on the drift-flux model have been derived to obtain the single-and two-phase pressure drop perturbations, by taking into account the slip between phases, nonuniform heat flux and heated wall dynamics. To assess the stability, the frequency domain technique with the Nyquist criterion has been used under the constant pressure drop boundary condition through the loop. The computer implementation of this model, SASG, was used for the parametric study of the steam generator in Kori-Unit 1. The results of the parametric study revealed important factors influencing UTSG stability margin.

  • PDF

Use of Higher Order Frequency Response Functions for Non-Linear Parameter Estimation (고차 주파수응답함수를 이용한 비선형 시스템의 매개변수 추정)

  • 이건명
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.40-45
    • /
    • 1994
  • 기계시스템의 비선형특성 해석을 위하여 여러가지 방법이 활용되고 있는데, 이들은 Nyquist 선도의 찌그러짐(distortion), Hilbert 변환, 복원력면(restoring force surface), NARMAX, 고차 주파수응답함수(higher order frequency response function), DPE(direct parameter estimation)를 이용한 방법등이다. 이들중 고차 FRF(frequency response function)는 그 개념이 선형시스템의 FRF와 유사하여 비선형시스템의 해석방법으로서 주목을 받고 있으나 아직은 고차 FRF의 특성에 대한 이론적 연구 단계이고, 고차 FRF로부터 비선형특성을 정량적으로 해석하는 연구는 거의 이루어지지 않고 있다. 다항식으로 표시되는 비선형성을 갖는 시스템이 정현파가진을 받을 때 그 응답의 가진주파수 성분은 가진력진폭과 고차 FRF의 무한급수로 나타낼 수 있다. 가진력의 진폭을 변화시켜가며 응답을 측정하고, 고차항을 무시하면 고차 FRF의 값을 근사적으로 구할 수 있다. 고차 FRF는 비선형 시스템의 매개변수의 식으로 나타낼 수 있으므로 이로부터 비선형 매개변수를 추정할 수 있다. 본 논문에서는 비선형강성과 비선형감쇠를 갖는 1자유도 시뮬레이션 시스템에 이 매개변수 추정법을 각각 적용함으로써 이 방법의 가능성을 고찰하였다.

  • PDF