• 제목/요약/키워드: number of fixture

검색결과 70건 처리시간 0.025초

외식산업의 창업에 대한 연구 (A Study on New Business of the Food Service Industry)

  • 조병소
    • 한국관광식음료학회지:관광식음료경영연구
    • /
    • 제9권
    • /
    • pp.273-302
    • /
    • 1998
  • INTERNATIONAL MONITORY FUNDS wave swept the Economic structural insolvency lies one upon another with low growth, low trust, low prices, low interest and low employment as[2 down 3 up] phenomenons have been distinguished and low enterprise a control of structures due to forecasting 200 million unemployment, including 600 million unemployed the head of a family population have a difficulty in their life. Only way to give them hope is through the commencement of an enterprises to have 2nd career development. But end of 1995, 467,00 dining out companies have been established and recently business are in depression. There are many business conditions of change of business or reduce operations, if unemployment populations of 5%, 100,000 peoples doing the commencement of an enterprises, enormous number of dining out companies will be increased and the competition will be fierce, especially those who have short knowledge and experience doing the commencement of an enterprises have high failure than success which will give a problems to society. Our study is to make the commencement of an enterprise to reducing the faiure and to be successful for main point to successful commencement of an enterprise, the established can self capability and mental condition, the main important factor is types of industry selection, successful and those established who takes this conditions will very carefully inspect various matters by scientifically and rationally mind industrys propulsion graphs and open official fixture graphs will framing detail factors. One by inspect the reduction of failure, and successful commencement of an enterproses mind industry have been studied.

  • PDF

Radiation effect on peri-implant tissue after implantation

  • Kweon, Hyeog-Sin;Song, Kwang-Yeob
    • 대한치과보철학회지
    • /
    • 제38권3호
    • /
    • pp.291-309
    • /
    • 2000
  • Statement of problem. There were several studies on the effects of irradiation to peri-implant bone tissue. However, no clear biological effect of irradiation on peri-implant bone tissue was reported yet. Purpose. This study compared the effect of irradiation on the surrounding tissue of a HA-coated implant fixture with controls. Material and methods. 6 Steri-Oss implants were implanted into the femur of 6 mongrels. The implanted dogs were divided into three groups and received irradiation. After 1 month, 2months and 4 months healing period, the histologic examination and mobility test and digital radiographic imaging analyses were performed to compare the control and experimental group respectively. Results. The irradiated group showed slower healing than control group in light microscopic observations. The mobility test demonstrated significant less number (Periotest) in control group than that of irradiated groups. The digital radiographic imaging analysis showed that the bone density of irradiated group was higher than control group. Conclusion. Generally, control group showed favorable biological response and less mobility than irradiated group. The conflict result of bone density value were measured by the digital radiographic imaging analysis. The digital radiographic imaging analysis needs more research in future.

  • PDF

Splinted or Non-splinted: 다수의 인접한 치아 결손부 수복을 위한 임플란트 보철 (Splinted and non-splinted implant-supported restorations : prosthetic considerations for restoring multiple adjacent teeth)

  • 윤형인
    • 대한치과의사협회지
    • /
    • 제54권3호
    • /
    • pp.198-205
    • /
    • 2016
  • The purpose of this paper was to investigate the significance of splinted and non-splinted implant-supported restorations with an internal connection for multiple consecutively missing teeth. Upon examination of the effects of fixture-abutment connection, the distribution of occlusal load was favorable in splinted implant-prosthesis with an external connection, but effect of strain distribution was not significant in splinted implant-prosthesis with an internal connection. In splinted implant-prostheses for short implants, strain distribution was not affected by the method of retention. For cement-retained prostheses, the effect of strain distribution due to splinting was not significant. In clinical studies, non-splinted prostheses with an internal connection for multiple consecutively missing teeth showed high survival rate, mild marginal bone loss, and stable periodontal condition. However, failure to achieve optimal proximal contact between single-unit prostheses may lead to food impaction, and veneer fracture may be inevitable when the framework provides inadequate support in the proximal region. In conclusion, splinted implant-prosthesis is not an indication in all cases, and clinical consideration of its use should be based on the patient's oral condition, such as location and number of implants, formation of proximal contact, canine guidance, existence of parafunctional habit, and oral hygiene, when multiple consecutively missing teeth are replaced by internal connection type implant.

  • PDF

솔레노이드 형태의 RF 칩 인덕터에 대한 연구 (A Study for Solenoid-Type RF Chip Inductors)

  • 김재욱;윤의중;정여창;홍철호
    • 한국전기전자재료학회논문지
    • /
    • 제13권10호
    • /
    • pp.840-846
    • /
    • 2000
  • In this work, small-size, high-performance solenoid-type RF chip inductors utilizing a low-loss Al$_2$O$_3$core material were investigated. The size of the chip inductors fabricated in this work were 15$\times$10$\times$0.7㎣, 2.1$\times$1.5$\times$10㎣, and 2.4$\times$2.0$\times$1.4㎣ and copper (Cu) wire with 40 ㎛ diameter was used as the coils. High frequency characteristics of the inductance, quality factor, and impedance of developed inductors were measured suing an RF Impedance/Material Analyzer (HP4291B with HP16193A test fixture). It was observed that the developed inductors with the number of turns of 7 have the inductance of 33 to 100nH and exhibit the self-resonant frequency (SRF) of .26 to 1.1 GHz. The SRF of inductors decreases with increasing the inductance and the inductors have the quality factor of 60 to 80 in the frequency range of 300 MHz to 1.1 GHz. In this study, small-size solenoid-type RF chip inductors with high inductance and high quality factor were fabricated successfully. It is suggested that the thin film-type inductor is necessary to fabricate the smaller size inductors at the expence of inductance and quality factor values.

  • PDF

유한요소법을 이용한 브러시레스 DC 모터의 특성 해석에 관한 연구 (A Study on the Characteristic Analysis of Brushless DC Motor Using FEM)

  • 정신영;송유석;이주;장석중;박건희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.920-922
    • /
    • 2002
  • This paper investigates the cogging torque reduction in a brushless DC(BLDC) motor having an inner-rotor with surface-mounted segment-type permanent magnets. The kind of magnets for the BLDC motor could have different waveforms of magnetization such as square, trapezoidal and sinusoidal form. This paper discusses the effect of the unsymmetrical magnetization distribution in the segment-type permanent magnet, which is able to obtain through a segment structure that the number of poles per segments is 2 ($N_p/N_s$), on the cogging torque and EMF waveform. Where the existing magnetizer fixture for the square-type magnetization is used to magnetize the magnets in two segment structures of $N_p/N_s$ = 1 and 2. The effectiveness of the proposed designs had been confirmed by comparing cogging torque, and EMF waveform between conventional and new models which are analyzed by Finite Element Method (FEM).

  • PDF

Experimental investigation of interlaminar mechanical properties on carbon fiber stitched CFRP laminates

  • Iwahori, Yutaka;Ishikawa, Takashi;Watanabe, Naoyuki;Ito, Akira;Hayashi, Yoichi;Sugimoto, Sunao
    • Advanced Composite Materials
    • /
    • 제16권2호
    • /
    • pp.95-113
    • /
    • 2007
  • Experimental investigations of interlaminar mechanical properties for carbon fiber reinforced plastic (CFRP) laminates were carried out using aramid fiber ($Kevlar^{(R)}$-29 1000d) and carbon fiber (TR40-1K 612d, Mitsubishi Rayon) stitching. Various carbon fiber (CF) stitch densities were used to prepare a number of CF stitched CFRP laminates for double cantilever beam (DCB) tests. An insert tongue-type loading fixture, developed by the Japan Aerospace Exploration Agency (formerly the National Aerospace Laboratory of Japan), was also employed in the DCB test. Interlaminar tension tests were carried out under an out-of-plane directional loading using a single CF stitch thread in the CFRP laminates. The DCB test results clarified that the relationship between the volume fractions of the CF stitch thread ($V_{ft}$) and mode I critical energy release rate ($G_{Ic}$) showed a mostly linear function with a higher gradient than that of the $Kevlar^{(R)}$ stitched CFRP laminates. The CF stitched CFRP tension test results indicated that the consumption energy per unit area ($E_i$) was larger than that of $Kevlar^{(R)}$ stitched CFRP laminates.

일체형 케이블 트레이의 롤포밍 성형해석에 관한 연구 (Roll Forming Analysis for All-in-one Cable Tray)

  • 한명철;성창민;김정관;권유홍
    • 한국기계가공학회지
    • /
    • 제17권4호
    • /
    • pp.143-149
    • /
    • 2018
  • A cable tray is a fixture to support and protect electrical and communication cables. In this study, a roll-forming analysis is conducted to produce an all-in-one cable tray. The number of process stands is calculated using an empirical formula. By applying bending methods to the design of the roll flower pattern, the final process stands and forming angles are determined. The shape and stress variations in the cable tray are modeled and observed by roll forming analysis using LS-DYNA Software. The width of the side rail and the maximum stress on all stands does not exceed the reference values. The forming machine and rolls are manufactured based on the results of the roll forming analysis. In addition, all-in-one cable trays satisfy the National Electrical Manufacturers Association standards when they are manufactured according to this design.

수종의 임플랜트 시스템의 나사풀림에 관한 연구 (Screw Loosening of Various Implant Systems)

  • 안진수;조인호;임주환;임헌송
    • 구강회복응용과학지
    • /
    • 제18권2호
    • /
    • pp.81-91
    • /
    • 2002
  • Dental implant systems have shown many post-surgical problems and One of the most frequent problem is screw loosening. To reduce screw loosening, a number of methods have been tried and recently fundamental modification of fixture-abutment connection structure was developed and used the most frequently. Former implant system structure, such as Br${\aa}$nemark, had external hex with the height of 0.7 mm and later, fixture with external hex of 1.0 mm height and internal hex structure were developed. In addition, the method of morse taper application was introduced to reduce screw loosening. In this study, the level of screw loosening of each implant systems was compared based on the vibration loosening measurement of abutment screw of each implant systems. Analysis of measured value was performed using 3 kinds of methods, (i) Percentage of average of initial 3 times loosening-torque value(initial loosening value) to tightening-torque of 30 Ncm, (ii) Percentage of loosening-torque value after 200 N strength loaded(experimental value) to initial loosening value and (iii) Percentage of experimental value to 30 Ncm of tightening-torque. Each result of analyses shows the value of initial loosening, loosening by repetitive load and final loosening level. The results of this study were as follows. (1) Percentage of initial loosening value to tightening-torque was increased in order of 0.7 mm external hex, 1.0 mm external hex, internal hex and internal taper and all values between each groups showed statistical significance (p<0.05). (2) Percentage of experimental value to initial loosening value was increased in order of internal hex, 0.7 mm external hex, 1.0 mm external hex and internal taper. Value of internal taper showed significant difference with that of 0.7 mm external hex and internal hex (p<0.05). (3) Percentage of experimental value to tightening torque was increased in order of 0.7 mm external hex, 1.0 mm external hex, internal hex and internal taper. Values of all groups showed statistical significance (p<0.05) except between the groups of 1.0 mm external hex and internal hex. Based on those results, there was no significant difference of loosening-torque by repetitive loading except internal taper. It is supposed that implant system with high resistant capability against initial loosening could be recommended for clinical use. In addition, in case of single implant restoration, 1.0 mm external hex or internal hex could be recommended rather than 0.7 mm external hex, and the use of internal taper would be the most useful way to reduce screw loosening.

$Br{\aa}nemark\;Novum^{(R)}$ 즉시 임플랜트 보철 수복 방법에 관한 삼차원 유한요소 분석적 연구 (THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF $BR{\AA}NEMARK\;NOVUM^{(R)}$ IMMEDIATE IMPLANT PROSTHODONTIC PROTOCOL)

  • 김우영;김영수;장경수;김창회
    • 대한치과보철학회지
    • /
    • 제39권5호
    • /
    • pp.463-476
    • /
    • 2001
  • Since the treatment of edentulous patients with osseointegrated implant was first introduced more than 30 years ago, implant therapy has become one of the most important dental treatment modalities today. Based on the previous experience and knowledge, $Br{\aa}nemark\;Novum^{(R)}$ protocol was introduced with the concept of simplifying surgical and prosthetic technique and reducing healing time recently. This protocol recommends the installation of three 5mm wide diameter futures in anterior mandible and the prefabricated titanium bars for superstructure fabrication. This study was designed to analyze the stress distribution at fixture and superstructure area according to changes of fixture number, diameter and superstructure materials. Four 3-dimensional finite element models were fabricated. Model 1 - 5 standard fixtures (13mm long and 3.75mm in diameter) & superstructure consisted of type IV gold alloy and resin Model 2- 3 wide diameter fixtures (13mm long and 5.0mm in diameter) & superstructure consisted of type IV gold alloy and resin Model 3-3 wide diameter fixtures (13mm long and 5.0mm in diameter) & superstructure consisted of titanium and resin Model 4-3 wide diameter fixtures (13mm long and 5.0mm in diameter) & superstructure consisted of titanium and porcelain A 150N occlusal force was applied on the 1st molar of each model in 3 directions - vertical($90^{\circ}$), horizontal($0^{\circ}$) and oblique($120^{\circ}$). After analyzing the stresses and displacements, following results were obtained. 1. There were no significant difference in stress distribution among experimental models. 2. Model 2, 3, 4 showed less amount of compressive stress than that of model 1. However, tensile stress was similar. 3. Veneer material with a high modulus of elasticity demonstrated less stress accumulation in the superstructure. Within the limites of this study, $Br{\aa}nemark\;Novum^{(R)}$ protocol demonstrated comparable biomechanical properties to conventional protocol.

  • PDF

크기에 따른 솔레노이드 형태 RF 칩 인덕터의 주파수 특성 연구 (A Study for Frequency Characteristics of Solenoid-Type RF Chip Inductors)

  • 김재욱
    • 전기전자학회논문지
    • /
    • 제11권4호
    • /
    • pp.145-151
    • /
    • 2007
  • 본 논문에서는 저손실 ${Al_2}{O_3}$ 코아 물질을 이용한 초소형 고성능 솔레노이드 형태 RF 칩 인덕터에 대하여 연구하였다. 본 논문에서 제작된 칩 인덕터의 크기는 $0.86{\times}0.46{\times}0.45m^3$, $1.5{\times}1.0{\times}0.7m^3$, $2.1{\times}1.5{\times}1.0m^3$$2.4{\times}2.0{\times}1.4m^3$으로 하였고, 코일은 $27{\sim}40{\mu}m$의 구리선을 사용하였다. 개발된 인덕터의 인덕턴스, 품질계수, 임피던스의 고주파수 특성은 HP16193A test fixture가 장착된 RF Impedance/Material Analyzer(HP4291B)를 이용하여 측정되었다. 7회 권선된 인덕터들은 13${\sim}$100nH의 인덕턴스와 6.4${\sim}$1.1GHz의 자기공진주파수를 가진다. 인덕터들의 자기공진주파수는 인덕턴스가 증가함에 따라 감소하고, 인덕터들의 직접쓰기는 300MHz${\sim}$1.3GHz의 주파수 범위에서 50${\sim}$80을 가진다. 본 연구에서는 높은 인덕턴스와 높은 직접쓰기를 갖는 초소형 솔레노이드 형태 RF 칩 인덕터가 성공적으로 제작되었다.

  • PDF