• Title/Summary/Keyword: nuclear reactions

Search Result 279, Processing Time 0.022 seconds

Multinuclear Solid-state NMR Investigation of Nanoporous Silica Prepared by Sol-gel Polymerization Using Sodium Silicate

  • Kim, Sun-Ha;Han, Oc-Hee;Kim, Jong-Kil;Lee, Kwang-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권10호
    • /
    • pp.3644-3649
    • /
    • 2011
  • Multinuclear solid-state nuclear magnetic resonance (NMR) experiments were performed to investigate the local structure changes of nanoporous silica during hydrothermal treatment and surface modification with 3-aminopropyltriethoxysilane (3-APTES). The nanoporous silica was prepared by sol-gel polymerization using inexpensive sodium silicate as a silica precursor. Using $^1H$ magic angle spinning (MAS) NMR spectra, the hydroxyl groups, which play an important role in surface reactions, were probed. Various silicon sites such as $Q^2$, $Q^3$, $Q^4$, $T^2$, and $T^3$ were identified with $^{29}Si$ cross polarization (CP) MAS NMR spectra and quantified with $^{29}Si$ MAS NMR spectra. The results indicated that about 25% of the silica surface was modified. $^1H$ and $^{29}Si$ NMR data proved that the hydrothermal treatment induced dehydration and dehyroxylation. The $^{13}C$ CP MAS and $^1H$ MAS NMR spectra of 3-APTES attached on the surface of nanoporous silica revealed that the amines of the 3-aminopropyl groups were in the chemical state of ${NH_3}^+$ rather than $NH_2$.

Influense of the high-voltage conductivity on peculiarity of polarization ferroelectric polymer on based vinylidenefluoride

  • Kochervinskii, V.V.;Chubunova, E.V.;Lebedinskii, Y.Y.;Pavlov, A.S.;Pakuro, N.I.
    • Advances in materials Research
    • /
    • 제4권2호
    • /
    • pp.113-132
    • /
    • 2015
  • The phenomena of high-voltage polarization and conductivity in oriented vinylidenefluoride and tetrafluoroethylene copolymer films have been investigated. It was shown that under certain electric fields, injection of carriers from the material of electrodes appears The barrier for holes injection in the copolymer was found to be lower than that for electrons. It results in more effective screening of the external field near the anode than near cathode. Electrones, ejected from cathode, creating negative charge by trapping on the surface. It is shown that the electrons injected from cathodes create a negative homocharge on the copolymer surface and then become captured on the surface shallow traps. Their nature has been studied by the x-ray photoelectron spectroscopy. It was shown that these traps may consist of chemical defects in the form of new functional groups formed by reactions of surface macromolecules with sputtered atoms of aluminum. The asymmetric shape of hysteresis curves was explained by the difference in mobility of injected holes and electrons. These factors caused appearance of "non-closed" hysteresis curves for fluorine-containing polymer ferroelectrics. Hysteresis phenomena observed at low electric fields (below coercive ones) are to associate with the behavior of the domains localized in the ordered regions formed during secondary crystallization of copolymers.

A frame work for heat generation/absorption and modified homogeneous-heterogeneous reaction in flow based on non-Darcy-Forchheimer medium

  • Hayat, Tasawar;Ahmad, Salman;Khan, Muhammad I.;Khan, Muhammad I.;Alsaedi, Ahmed
    • Nuclear Engineering and Technology
    • /
    • 제50권3호
    • /
    • pp.389-395
    • /
    • 2018
  • The present work aims to report the consequences of Darcy-Forchheimer medium in flow of Cross fluid model toward a stretched surface. Flow in porous space is categorized by Darcy-Forchheimer medium. Further heat transfer characteristics are examined via thermal radiation and heat generation/absorption. Transformation procedure is used. The arising system of nonlinear ordinary differential equations is solved numerically by means of shooting method. The effects of different flow variables on velocity, temperature, concentration, skin friction, and heat transfer rate are discussed. The obtained outcomes show that velocity was enhanced with the increase in the Weissenberg number but decays with increase in the porosity parameter and Hartman number. Temperature field is boosted by thermal radiation and heat generation; however, it decays with the increase in the Prandtl number.

지질강하제에 의한 횡문근 융해증 1예 (A Case of Rhabdomyolysis Induced by Lipid Lowering Agent)

  • 고은미;이태원;임천규;김광원;김명재;최영길
    • 대한핵의학회지
    • /
    • 제24권1호
    • /
    • pp.145-148
    • /
    • 1990
  • Bezafibrate is a lipid?lowering agent and one of the fibric acid derivatives. It is relatively safe and well tolerated and adverse reactions to bezafibrate have largely been restricted to gastrointestinal distrubances. But a few cases of rhabdomyolysis after bezafibrate administration have been reported and recently we experienced bezafibrate-induced rhabdomyolysis in patients with chronic renal failure. So we report this case with the bone scan finding and the literature review We believe that this is the first case report of bezafibrate-induced rhabdomyolysis in Korea.

  • PDF

Influence of Microbial Activity on the Long-Term Alteration of Compacted Bentonite/Metal Chip Blocks

  • Lee, Seung Yeop;Lee, Jae-Kwang;Kwon, Jang-Soon
    • 방사성폐기물학회지
    • /
    • 제19권4호
    • /
    • pp.469-477
    • /
    • 2021
  • Safe storage of spent nuclear fuel in deep underground repositories necessitates an understanding of the long-term alteration of metal canisters and buffer materials. A small-scale laboratory alteration test was performed on metal (Cu or Fe) chips embedded in compacted bentonite blocks placed in anaerobic water for 1 year. Lactate, sulfate, and bacteria were separately added to the water to promote biochemical reactions in the system. The bentonite blocks immersed in the water were dismantled after 1 year, showing that their alteration was insignificant. However, the Cu chip exhibited some microscopic etch pits on its surface, wherein a slight sulfur component was detected. Overall, the Fe chip was more corroded than the Cu chip under the same conditions. The secondary phase of the Fe chip was locally found as carbonate materials, such as siderite (FeCO3) and calcite ((Ca, Fe)CO3). These secondary products can imply that the local carbonate occurrence on the Fe chip may be initiated and developed by an evolution (alteration) of bentonite and a diffusive provision of biogenic CO2 gas. These laboratory scale results suggest that the actual long-term alteration of metal canisters/bentonite blocks in the engineered barrier could be possible by microbial activities.

Nano Yttrium-90 and Rhenium-188 production through medium medical cyclotron and research reactor for therapeutic usages: A Simulation study

  • Abdollah Khorshidi
    • Nuclear Engineering and Technology
    • /
    • 제55권5호
    • /
    • pp.1871-1877
    • /
    • 2023
  • The main goal of the coordinated project development of therapeutic radiopharmaceuticals of Y-90 and Re-188 is to exploit advancements in radionuclide production technology. Here, direct and indirect production methods with medium reactor and cyclotron are compared to evaluate derived neutron flux and production yield. First, nano-sized 186W and 89Y specimens are suspended in water in a quartz vial by FLUKA simulation. Then, the solution is irradiated for 4 days under 9E+14 n/cm2/s neutron flux of reactor. Also, a neutron activator including three layers-lead moderator, graphite reflector, and polyethylene absorbent- is simulated and tungsten target is irradiated by 60 MeV protons of cyclotron to generate induced neutrons for 188W and 90Sr production via neutron capture. As the neutron energy reduced, the flux gradually increased towards epithermal range to satisfy (n/2n,γ) reactions. The obtained specific activities at saturation were higher than the reported experimental values because the accumulated epithermal flux and nano-sized specimens influence the outcomes. The beta emitters, which are widely utilized in brachytherapy, appeal an alternative route to locally achieve a rational yield. Therefore, the proposed method via neutron activator may ascertain these broad requirements.

Feasibility study of a resistive-type sodium aerosol detector with ZnO nanowires for sodium-cooled fast reactors

  • Jewhan Lee;Da-Young Gam;Ki Ean Nam;Seong J. Cho;Hyungmo Kim
    • Nuclear Engineering and Technology
    • /
    • 제55권7호
    • /
    • pp.2373-2379
    • /
    • 2023
  • In sodium systems, leakage is one of the safety concerns; it can cause chemical reactions, which may result in fires. There are contact and non-contact types of leak detectors, and the conventional method of non-contact type detection is by gas sampling. Because of the complexity of this method, there has always been a need for a simple gas sensor, and the resistive-type nanostructure ZnO sensor is a promising option with various advantages. In this study, a ZnO sensor was fabricated, and the concept was tested as a leak detector using a dedicated experiment facility. The experiment results showed distinctive changes in resistance with the presence of sodium aerosol under various conditions. Replacing the conventional gas sampling with the ZnO sensors is expected to enable identification of the leakage location if used as a point-wise instrumentation and to greatly reduce the total cost, making the system simple, light, and effective. For further study, more tests will be performed to evaluate the sensitivity of key parameters under various conditions.

Measurements of proton beam flux and energy of APEP using foil activation technique

  • Wenlin Li;Qifan Dong;Hantao Jing;Li Ou;Zhixin Tan;Sixuan Zhuang;Qingbiao Wu
    • Nuclear Engineering and Technology
    • /
    • 제56권1호
    • /
    • pp.328-334
    • /
    • 2024
  • The activation method of metallic foils is an important technique to measure the flux and energy of proton beams. In this paper, the method was used to measure the CSNS APEP proton flux at seven nominal proton energies ranging from 10 MeV to 70 MeV for beam spot sizes of the 20 mm × 20 mm and 50 mm × 50 mm. The reactions of natTi(p, x)48V, natNi(p, x)57Ni, natCu(p, x)58Co, and 27Al(p, x)24Na were employed to measure the proton beam flux with a range of 107-109 p/cm2/s. Furthermore, we also proposed a method using the activity ratio with a stacked-foil target to determine the energy spread of a Gaussian-like distribution for different nominal proton energies. The optimal combinations of Al, Cu, Ti, Ni, Mo, Fe, Nb, and In foils were adopted for the proton energies. The measured energy spreads for degraded beams of 30 MeV-70 MeV were found to be smaller than 10.00%.

Correction of Prompt Gamma Distribution for Improving Accuracy of Beam Range Determination in Inhomogeneous Phantom

  • Park, Jong Hoon;Kim, Sung Hun;Ku, Youngmo;Lee, Hyun Su;Kim, Young-su;Kim, Chan Hyeong;Shin, Dong Ho;Lee, Se Byeong;Jeong, Jong Hwi
    • 한국의학물리학회지:의학물리
    • /
    • 제28권4호
    • /
    • pp.207-217
    • /
    • 2017
  • For effective patient treatment in proton therapy, it is therefore important to accurately measure the beam range. For measuring beam range, various researchers determine the beam range by measuring the prompt gammas generated during nuclear reactions of protons with materials. However, the accuracy of the beam range determination can be lowered in heterogeneous phantoms, because of the differences with respect to the prompt gamma production depending on the properties of the material. In this research, to improve the beam range determination in a heterogeneous phantom, we derived a formula to correct the prompt-gamma distribution using the ratio of the prompt gamma production, stopping power, and density obtained for each material. Then, the prompt-gamma distributions were acquired by a multi-slit prompt-gamma camera on various kinds of heterogeneous phantoms using a Geant4 Monte Carlo simulation, and the deduced formula was applied to the prompt-gamma distributions. For the case involving the phantom having bone-equivalent material in the soft tissue-equivalent material, it was confirmed that compared to the actual range, the determined ranges were relatively accurate both before and after correction. In the case of a phantom having the lung-equivalent material in the soft tissue-equivalent material, although the maximum error before correction was 18.7 mm, the difference was very large. However, when the correction method was applied, the accuracy was significantly improved by a maximum error of 4.1 mm. Moreover, for a phantom that was constructed based on CT data, after applying the calibration method, the beam range could be generally determined within an error of 2.5 mm. Simulation results confirmed the potential to determine the beam range with high accuracy in heterogeneous phantoms by applying the proposed correction method. In future, these methods will be verified by performing experiments using a therapeutic proton beam.

Usefulness of cyclic thermal therapy and red blood cell scintigraphy in patients with chemotherapy-induced peripheral neuropathy

  • Kim, Minjoo;Kim, Eun-Mi;Oh, Phil-Sun;Lim, Seok Tae;Sohn, Myung-Hee;Song, Eun-Kee;Park, Keon Uk;Kim, Jin Young;Won, Kyoung Sook;Jeong, Hwan-Jeong
    • The Korean Journal of Pain
    • /
    • 제34권4호
    • /
    • pp.427-436
    • /
    • 2021
  • Background: Pharmacological and non-pharmacological therapies have been used to treat patients with chemotherapy-induced peripheral neuropathy (CIPN). However, the effect of therapies in cancer patients has yet to be investigated comprehensively. We hypothesized that cyclic thermal therapy would improve blood flow and microcirculation and improve the symptoms driven by CIPN. Methods: The criteria of assessment were blood volume in region of interest (ROI) in the images, and European Organization for Research and Treatment of Cancer-Quality of Life Questionnaire-Chemotherapy-Induced Peripheral Neuropathy 20 questionnaire scores. The blood volume was quantified by using red blood cell (RBC) scintigraphy. All patients were treated 10 times during 10 days. The thermal stimulations, between 15° and 41°, were repeatedly delivered to the patient's hands. Results: The total score of the questionnaires, the score of questions related to the upper limbs, the score of questions closely related to the upper limbs, and the score excluding the upper limbs questions was decreased. The blood volume was decreased, and the variance of blood volume was decreased. During cooling stimulation, the blood volume was decreased, and its variance was decreased. During warming stimulation, the blood volume was decreased, and its variance was decreased. Conclusions: We suggest that cyclic thermal therapy is useful to alleviate CIPN symptoms by blood circulation improvement. RBC scintigraphy can provide the quantitative information on blood volume under certain conditions such as stress, as well as rest, in peripheral tissue.