• Title/Summary/Keyword: nuclear physics

Search Result 1,063, Processing Time 0.027 seconds

Determination of Exposure Dose Rate and Isotropic Distributions of Substitute High Dose Rate Ir-192 Source for Co-60 Brachytherapy Source (원격강내조사용 Co-60 선원의 대체용 Ir-192 선원의 조사선량결정 및 선량 등방성조사)

  • 최태진;원철호;김옥배;김시운;김금배;조운갑;한현수;박경배
    • Progress in Medical Physics
    • /
    • v.9 no.1
    • /
    • pp.55-64
    • /
    • 1998
  • In recent, the demand of development of the high dose rate brachytherapy source increased for substitute for Co-60 source by iridium source, since the supplying Co-60 source is very depressed and the high dose rate brachytherapy sources are entirely imported from the abroad. This study investigated the exposure rates and isotropic dose distributions for the Ir-192 source produced from $\^$191/Ir(n,r)$\^$192/Ir by nuclear reactor in Korea Atomic Energy Research Institute. The activity of source was obtained an 1.012 Ci (the initial activity without encapsulation was 2,87Ci) by measurement with encapsuled stainless steel. The exposure rate of provided Ir-192 source was determined on 6.36 ${\pm}$ 0.147 Rm$^2$/h-GBq (2.350 ${\pm}$ 0.054 Rcm$^2$/mCi-hr) within ${\pm}$ 2.2% discrepancy with IC-10 ion chamber (0.14 cc) which was mounted on the acrylic jig to 5, 10 and 20 cm from the center of source. The calculated doses with 22 most significant spectrum lines were corrected with intrinsic efficiency of the germanium detector were compared to measured exposure dose rates within ${\pm}$3.8 % discrepancy. The authors confirmed the high dose rate Ir-192 source could be replaced the long decayed Co-60 source via investigation of the isotropic dose distributions in lateral, source axis and diagonal direction of source center are very closed to within 3% uncertainties. Especially, this exposure rate constant and isotropic dose distribution will be fundamental to build the high dose rate source and develop the computed therapy planning system.

  • PDF

Comparison of Skin Dose Measurement Using Glass Dosimeter and Diode for Breast Cancer Patients (유리 선량계와 다이오드 측정기를 이용한 유방암 환자의 체표면 선량측정 비교)

  • Ko, Young-Eun;Park, Sung-Ho;Choi, Byoung-Joon;Kim, Hee-Sun;Noh, Young-Ju
    • Progress in Medical Physics
    • /
    • v.19 no.1
    • /
    • pp.9-13
    • /
    • 2008
  • The purpose of this study was to measure the skin dose using the glass dosimeter and diode and to compare those measurements to the planned skin dose from the treatment planning system. For the reproducibility of the glass dosimeter (ASAHI TECHNO GLASS CIRPORATION, Japan), the same dose was irradiated to 40 glass dosimeters three times, among which 28 with the reproducibility within 3% were selected for the use of this study. For each of 27 breast cancer patients, the glass dosimeters and diodes were attached to 4 different locations on the skin to measure the dose during treatment. All the patients received one fraction of 180 cGy each. The maximum difference of measurements between the glass dosimeter and diode at the same location was 3.2%. Comparing with the planned skin dose from the treatment planning system (Eclipse v6.5, Varian, USA), the dose measured by the glass dosimeter and the diodeshowed on an average 3.4% and 2.3% difference, respectively. The measured doses were always less than the planned skin dose. This may be due to the specific errors of both detectors. Also, the difference may be caused by the fact that since the skin where the detectors were attached is pretty moveable, it was not fix the detectors on the skin.

  • PDF

Measurement and Estimation for the Clearance of Radioactive Waste Contaminated with Radioisotopes for Medical Application (의료용 방사성폐기물 자체처분을 위한 방사능 측정 및 평가)

  • Kim, Changbum;Park, MinSeok;Kim, Gi-Sub;Jung, Haijo;Jang, Seongjoo
    • Progress in Medical Physics
    • /
    • v.25 no.1
    • /
    • pp.8-14
    • /
    • 2014
  • The amounts of radioactive wastes to be disposed in the medical institute have been increased due to development of radiation diagnosis and therapy rapidly. They are produced mostly by the very short lived radioisotopes such as $^{18}F$ used in PET/CT, $^{99m}Tc$, $^{123}I$, $^{125}I$ and $^{201}Tl$, etc. IAEA proposed a criteria for the clearance level of waste which depends on the individual ($10{\mu}Sv/y$) and collective dose (1 man-Sv/y), and concentration of each nuclide (IAEA Safety Series No 111-P-1.1, 1992 and IAEA RS-G-1.7, 2004). Radioactive wastes of $^{18}F$, $^{99m}Tc$, $^{123}I$, $^{125}I$ and $^{201}TI$ in the several types of container like Marinelli beaker, vial and plastic, were collected to measure the concentration of the waste of each nuclide in accordance with IAEA criteria. The measurement method and procedure of determining specific activity of the wastes using gamma emitters like MCA, gamma counter and beta emitters were developed. For the efficiency calibration of the detectors, CRM (certified reference material) which has the same dimension and shape was provided by Korea Research Institute of Standards and Science (KRISS). Correction factor of the radioactivity decay was calculated based on the measurement results, and the consideration of mutual relation with theoretical equation. The result of this study will be proposed as ISO standard.

Development of Phantom for Evaluate the Suitability of Ir-192 HDR Source with Brachytherapy Tools (근접치료용 하나로 생산 Ir-192 선원의 임상기기 적합성평가용 팬톰개발)

  • Shin, Kyo Chul;Choi, Sang Gyu;Kim, Ki Hwan;Son, Kwang Jae;Jeong, Dong Hyeok;Kim, Jeung Kee
    • Progress in Medical Physics
    • /
    • v.24 no.3
    • /
    • pp.171-175
    • /
    • 2013
  • Applicator of various kind of number ten kinds is used to raise from efficiency of brachytherapy to maximum. The compatibility of radiation source and applicator is very important subject for safety brachytherapy. Developed high dose rate brachytherapy source through Hanaro nuclear reactor in Korea Atomic Energy Research Institute and improve compatibility with using equipment in present. In this research, we wished to evaluate stability mechanical safety of radiation source and we developed phantom for evaluate several quality about Ir-192 sealed source that improve newly in Korea Atomic Energy Research Institute and is improved. The result for suitability of Ir-192 HDR source with brachytherapy tools that did normal operation in 2.2~2.7 cm extent about change of equal curvature and consider change of sudden curvature that did normal operation in radius 1.5~1.8 cm extent.

Multi-tracer Imaging of a Compton Camera (다중 추적자 영상을 위한 컴프턴 카메라)

  • Kim, Soo Mee
    • Progress in Medical Physics
    • /
    • v.26 no.1
    • /
    • pp.18-27
    • /
    • 2015
  • Since a Compton camera has high detection sensitivity due to electronic collimation and a good energy resolution, it is a potential imaging system for nuclear medicine. In this study, we investigated the feasibility of a Compton camera for multi-tracer imaging and proposed a rotating Compton camera to satisfy Orlov's condition for 3D imaging. Two software phantoms of 140 and 511 keV radiation sources were used for Monte-Carlo simulation and then the simulation data were reconstructed by listmode ordered subset expectation maximization to evaluate the capability of multi-tracer imaging in a Compton camera. And the Compton camera rotating around the object was proposed and tested with different rotation angle steps for improving the limited coverage of the fixed conventional Compton camera over the field-of-view in terms of histogram of angles in spherical coordinates. The simulation data showed the separate 140 and 511 keV images from simultaneous multi-tracer detection in both 2D and 3D imaging and the number of valid projection lines on the conical surfaces was inversely proportional to the decrease of rotation angle. Considering computation load and proper number of projection lines on the conical surface, the rotation angle of 30 degree was sufficient for 3D imaging of the Compton camera in terms of 26 min of computation time and 5 million of detected event number and the increased detection time can be solved with multiple Compton camera system. The Compton camera proposed in this study can be effective system for multi-tracer imaging and is a potential system for development of various disease diagnosis and therapy approaches.

The Effect of Thin Teflon on TLD Response for in vivo Dosimetry of Radiotherapy (생체 내 흡수선량 측정을 위한, 얇은 테프론의 TLD 반응감도에 대한 효과성)

  • Kim, Sookil;Yum, Ha-Young;Jeong, Tae-Sig;Moon, Chang-Woo
    • Progress in Medical Physics
    • /
    • v.14 no.2
    • /
    • pp.74-80
    • /
    • 2003
  • The purpose of this study was to evaluate the performance of the teflon encapsulated TLD rod, which may be used in nuclear medicine for the direct in vivo measurements of radiation dose. We analyzed the influence of teflon encapsulation for measuring absorbed dose. An experiment was carried out to evaluate and observe the response of a LiF TLD-100 rod in a thin-wall teflon capsule at different depths in a solid phantom. An adult anthropomorphic phantom was used to measure the absorbed dose using thin teflon encapsulated TLD. The measurements of PDD-, and TMR in solid phantom and athe bsorbed dose in humanoid phantom performed with normal TLD were compared with values obtained by teflon encapsulated TLD. It was demonstrated that the difference of TL response of LiF in phantom with and without teflon thin-wall capsule was less than 3% under the same conditions beyond the build-up region. However, significant differences were observed near the phantom surface because of the build-up effect caused by the thin-wall thickness of the teflon capsule. Thus, our study showed that the contribution of teflon thin-wall capsule to TLD response for the megavoltage photon beams was negligible and that it did not significantly effect dose measurement. The teflon encapsulated TLD described in this work has been proven to be appropriate for in vivo dosimetry in therapeutic environments.

  • PDF

Development and Performance Test of Preamplifier and Amplifier for Gamma Probe (감마프로브용 전단증폭기와 주증폭기의 개발과 성능 평가)

  • Bong, Jung-Kyun;Kim, Hee-Joung;Lee, Jong-Doo;Kwon, Soo-Il
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.1
    • /
    • pp.100-109
    • /
    • 1999
  • Purpose: Preamplifier and amplifier are very important parts for developing a portable counting or imaging gamma probe. They can be used for analyzing pulses containing energy and position information for the emitted radiations. The commercial Nuclear Instrument Modules (NIMs) can be used for processing these pulses. However, it may be improper to use NIMs in developing a portable gamma probe, because of its size and high price. The purpose of this study was to develop both preamplifier and amplifier and measure their performance characteristics. Materials and Methods: The preamplifier and amplifier were designed as a charge sensitive device and a capacitor resistor-resistor capacitor (CR-RC) electronic circuit, respectively, and they were mounted on a print circuit board (PCB). We acquired and analyzed energy spectra for Tc-99m and Cs-137 using both PCB and NIMs. Multichannel analyzer (Accuspec/A, Canberra Industries Inc., Meriden Connecticut, U.S.A) and scintillation detectors (EP-047(Bicron Saint-Gobain/Norton Industrial EP-047 (Ceramics Co., Ohio, U.S.A) with $2"{\times}2"$ NaI(T1) crystal and R1535 (Hamamatsu Photonics K.K., Electron Tube Center, Shizuoka-ken, Japan) with $1"{\times}1"$ NaI(T1) crystal were used for acquiring the energy spectra. Results: Using PCB, energy resolutions of EP-047 detectors for Tc-99m and Cs-137 were 12.92% and 5.01%, respectively, whereas R1535 showed 13.75% and 5.19% of energy resolution. Using the NIM devices, energy resolutions of EP-047 detector for Tc-99m and Cs-137 were measured as 14.6% and 7.58%, respectively. However, reliable energy spectrum of R1535 detector could not be acquired, since its photomultiplier tube (PMT) requires a specific type of preamplifier. Conclusion: We developed a special preamplifier and amplifier suitable for a small sized gamma probe that showed good energy resolutions independent of PMT types. The results indicate that the PCB can be used in developing both counting and imaging gamma probe.

  • PDF

Effect of Acute and Chronic Treatment with Risperidone on the Serotonin and Dopamine Receptors in the Rat Brain (Risperidone의 급성 및 만성 투여가 흰쥐 뇌의 Serotonin과 Dopamine 수용체에 미치는 영향)

  • Choi, Yun-Young;Son, Hye-Kyung;Kim, Chang-Yoon;Lee, Chul;Lee, Hee-Kyung;Moon, Dae-Hyuk
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.1
    • /
    • pp.9-18
    • /
    • 1997
  • The therapeutic efficacy of antipsychotic drugs is generally attributed to their ability to block dopamine $D_2$ receptors. Classical $D_2$ antagonists are not effective to treat negative symptoms and produce extrapyramidal side effects On the other hand, atypical antipsychotic agents ameliorate negative symptoms without producing extra-pyramidal side effects, and it is reported to be associated with blockade of serotonin $5-HT_2$ receptors. The purpose of this study was to evaluate the effect of risperidone on neuroreceptors in the rat brain by Quantitative autoradiography method. In acute treatment group, risperidone was injected into Peritoneal cavity of male Wistar rats with dose of 0, 0.1, 0.25, 0.5, 1.0 and 2.0mg/kg in each group(5/group), and they were decapitated after 2 hours. In chronic treatment group, risperidone was injected with dose of 0, 0.1, and 1mg/kg(I.P.) for 21 days and decapitated after 24 hours following last treatment. The effect of risperodone on the binding of [$^3H$]spiperone to $5-HT_2$ and $D_2$ receptors were analysed in 4 discrete regions of the striatum, nucleus accumbens, and frontal cortex by quantitative autoradiography Acute treatment with risperidone reduced cortical $5-HT_2$ specific [$^3H$]spiperone binding to 32% of vehicle-treated control. Subcortical $5-HT_2$ specific [$^3H$]spiperone binding was not affected at all dose groups whereas a significant reduction (57%) in $D_2$ specific [$^3H$]spiperone binding was observed in risperidone treated group at doses of 1-2mg/kg. Chronic treatment with risperidone produced a decrease in the maximal number of cortical $5-HT_2$ receptors to 51% and 46% of control in 0.1mg/kg & 1mg/kg treated group respectively. In conclusion, risperidone is a cortical serotonin receptor antagonist with relatively weak antagonistic action on dopamine receptors. These effects oil neuroreceptors may explain the therapeutic effect of risperidone as a atypical antipsychotic agents.

  • PDF

Development of liquid target for beam-target neutron source & two-channel prototype ITER vacuum ultraviolet spectrometer

  • Ahn, B.N.;Lee, Y.M.;Dang, J.J.;Hwang, Y.S.;Seon, C.R.;Lee, H.G.;Biel, W.;Barnsley, R.;Kim, D.E.;Kim, J.G.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.421-422
    • /
    • 2011
  • The first part is about development of a liquid target for a neutron source, which is designed to overcome many of the limitations of traditional beam-target neutron generators by utilizing a liquid target neutron source. One of the most critical aspects of the beam-target neutron generator is the target integrity under the beam exposure. A liquid target can be a good solution to overcome damage to the target such as target erosion and depletion of hydrogen isotopes in the active layer, especially for the one operating at high neutron fluxes with no need for water cooling. There is no inherent target lifetime for the liquid target neutron generator when used with continuous refreshment of the target surface exposed to the energetic beam. In this work, liquid target containing hydrogen has been developed and tested in vacuum environment. Potentially, liquid targets could allow a point neutron source whose spatial extension is on the order of 1 to $10{\mu}m$. And the second is about the vacuum ultraviolet (VUV) spectrometer which is designed as a five-channel spectral system for ITER main plasma measurement. To develop and verify the design, a two-channel prototype system was fabricated with No. 3 (14.4 nm~31.8 nm) and No. 4 (29.0 nm~60.0 nm) among the five channels. For test of the prototype system, a hollow cathode lamp is used as a light source. The system is composed of a collimating mirror to collect the light from source to slit, and two holographic diffraction gratings with toroidal geometry to diffract and also to collimate the light from the common slit to detectors. The two gratings are positioned at different optical distances and heights as designed. To study the appropriate detector for ITER VUV system, two different electronic detectors of the back-illuminated charge coupled device and the micro-channel plate electron multiplier were installed and the performance has been investigated and compared in the same experimental conditions. The overall system performance was verified by measuring the spectrums.

  • PDF

Impedance Changes of Living Tissue During Radiation Exposure Dose (방사선 피폭선량에 대한 생체 조직의 임피던스 변화)

  • Kil, Sang Hyeong;Lee, Moo Seok;Nam, Ji Ho;Lee, Yeong Hwa;Kim, Gun Do;Lee, Jong Kyu
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.4
    • /
    • pp.202-207
    • /
    • 2013
  • Bioimpedance involves a lot of information related to living tissue. If there is alteration in bio tissue, its electrical characteristics also change. It is to study electrical characteristics of pork tenderlion in using a HP-4194A Impedance/Gain-phase analyzer instrument and electrical characteristics changes by graded radiation exposure dose. The results were as follow 1. Electrical characteristics of pork tenderlion in repeated measurement had high precision within ${\pm}5$% of coefficiency of variability. 2. During the measurement impedance absolute value and phase alteration did not show statistically significant difference.(p>0.05) 3. While impedance phase of electrical characteristics associated with frequency change was almost stable, impedance absolute value was in inverse proportion to frequency that means high inverse correlation of -0.096(r). 4. Impedance absolute value dropped in radiation exposure dose. The alteration of the value did not show statistically significant difference in 1 Gy, 2 Gy and 4 Gy.(p>0.05) However in radiation exposure dose of 10 Gy, the decrease of impedance absolute value was significantly different.(p<0.05) 5. Impedance phase according to radiation exposure dose change did not show statistically significant difference in 1 Gy, 2 Gy, 4 Gy, and 10 Gy(p>0.05).