• Title/Summary/Keyword: nose change

Search Result 120, Processing Time 0.021 seconds

Implementation of Nose and Face Detections in Depth Image

  • Kim, Heung-jun;Lee, Dong-seok;Kwon, Soon-kak
    • Journal of Multimedia Information System
    • /
    • v.4 no.1
    • /
    • pp.43-50
    • /
    • 2017
  • In this paper, we propose a method which detects the nose and face of certain human by using the depth image. The proposed method has advantages of the low computational complexity and the high accuracy even in dark environment. Also, the detection accuracy of nose and face does not change in various postures. The proposed method first locates the locally protruding part from the depth image of the human body captured through the depth camera, and then confirms the nose through the depth characteristic of the nose and surrounding pixels. After finding the correct pixel of the nose, we determine the region of interest centered on the nose. In this case, the size of the region of interest is variable depending on the depth value of the nose. Then, face region can be found by performing binarization using the depth histogram in the region of interest. The proposed method can detect the nose and the face accurately regardless of the pose or the illumination of the captured area.

Development of an Electronic Nose System for Evaluation of Freshness of Pork (돈육의 신선도 평가를 위한 전자코 시스템 개발)

  • Lee, Hoon-Soo;Cho, Byoung-Kwan;Chung, Chang-Ho;Lee, Ki-Teak;Jo, Cheo-Run
    • Journal of Biosystems Engineering
    • /
    • v.34 no.6
    • /
    • pp.462-469
    • /
    • 2009
  • The aim of this study was to develop a portable electronic nose system for freshness measurement of stored pork. An electronic nose system was constructed using seven different MOS sensor array. To determine the quality change of pork with storage time, the samples were divided into ten groups in terms of storage time with an increment of 2 day up to 19 storage days. GC-MS, total bacteria's count (TBC), thiobarbituric acid reactive substance (TBARS), and pH analyses as well as the analysis of the electronic nose system measurement were performed to monitor the freshness change of the samples. To investigate the performance of the electronic nose system for detecting the change of freshness of pork, the acquired signal values of the system were compared with those of GC-MS, TBC, TBARS, and pH analysis values. According to principal component analysis (PCA) and linear discriminant analysis (LDA) with the signals of the electronic nose system for the pork samples, the sample groups were clearly separated into two groups of 1-9 days and 11-19 days, and four groups of 1-3 days, 5-9 days, 11 days, and 13-19 days respectively. The results show that the electronic nose system has potential for evaluating freshness of pork.

GROWTH CHANGES IN EXTERNAL NOSE OF THE KOREAN PEOPLE FROM 8 TO 16 YEARS OLD (한국인 8세에서 16세까지 비부외형의 성장 변화)

  • Park, Hyea-Kyung;Kyung, Hee-Moon;Kwon, Oh-Won
    • The korean journal of orthodontics
    • /
    • v.23 no.2 s.41
    • /
    • pp.249-261
    • /
    • 1993
  • This study was conducted to examine the growth change in external nose according to age which plays an important role in determining the facial profile, by analysing the biennial serial lateral cephalograms of 20 males and 20 females of mean 8.5 years old to 16.5 years old who have a normal occlusion. The results of this study were summarized as follows. $\cdot$ Both mean and standard deviation were obtained according to each item, sex and age for the male and female. $\cdot$ Nose heights of the male and female increased with increase in their age. The upper to lower nose height ratio somewhat decreased for both male and female with increase of age. The mean ratio was 3.69 : 1 for the male, respectively, and 3.83 : 1 for the female during this study.$\cdot$ The nose depth indicated the most significant increase of all items according to the increase of age, while the sagittal depth inicated higher value for the female than that of the male in the most age groups. $\cdot$ The nose inclination did not show a remarkable change during this study. $\cdot$ The proportions of growth completed at the earliest age showed the highest percentage for sagittal depth(male : $87.14\%$ & female : $91.29\%$). Also, the male indicated the lowest percentage in lower nose height $(73.04\%)$, while the female did the lowest in nose depth$(79.09\%)$. $\cdot$ There was shown the variable of the greatest correlation between the upper nose inclination and nose depth. $\cdot$ From this study, the whole external nasal growth was occurred downward and forward which was more frequent for forward growth than vertical growth.

  • PDF

Nasal airway function after Le Fort I osteotomy with maxillary impaction: A prospective study using the Nasal Obstruction Symptom Evaluation scale

  • Kim, Hyo Seong;Son, Ji Hwan;Chung, Jee Hyeok;Kim, Kyung Sik;Choi, Joon;Yang, Jeong Yeol
    • Archives of Plastic Surgery
    • /
    • v.48 no.1
    • /
    • pp.61-68
    • /
    • 2021
  • Background This study evaluated changes in nasal airway function following Le Fort I osteotomy with maxillary impaction according to the Nasal Obstruction Symptom Evaluation (NOSE) scale. Methods This cohort study included 13 patients who underwent Le Fort I osteotomy with maxillary impaction. Nasal airway function was evaluated based on the NOSE scale preoperatively and at 3 months postoperatively. The change in the NOSE score was calculated as the preoperative score minus the postoperative score. If the normality assumptions for changes in the NOSE score were not met, a nonparametric test (the Wilcoxon signed-rank test) was used. Differences in NOSE score changes according to patient characteristics and surgical factors were evaluated using the Kruskal-Wallis test and the Mann-Whitney test. Results Patients ranged in age from 18 to 29 years (mean ±standard deviation [SD], 23.00±3.87 years). Three were men and 10 were women. Eleven patients (84%) had an acquired dentofacial deformity with skeletal class III malocclusion. The preoperative NOSE scores ranged from 40 to 90 (mean±SD, 68.92±16.68), and the postoperative NOSE scores ranged from 25 to 80 (53.84±18.83). The cohort as a whole showed significant improvement in nasal airway function following maxillary impaction (P=0.028). Eleven patients (84%) had either improved (n=8) or unchanged (n=3) postoperative NOSE scores. However, nasal airway function deteriorated in two patients. Patient characteristics and surgical factors were not correlated with preoperative or postoperative NOSE scores. Conclusions Nasal airway function as evaluated using the NOSE scale improved after maxillary impaction.

Volatile Discrimination of Irradiated and Fumigated White Ginseng Powders at Different Storage Times and Temperatures Using the Electronic Nose

  • Shin, Jung-Ah;Kwon, Joong-Ho;Lee, Ki-Teak
    • Preventive Nutrition and Food Science
    • /
    • v.11 no.3
    • /
    • pp.237-242
    • /
    • 2006
  • The pattern of volatile emissions from white ginseng powders (WGP) that were treated with selected preservatives was investigated during 5-months of storage (at -10 and $25^{\circ}C$) by an electronic nose system equipped with 12 metal-oxide sensors. WGP were treated with gamma radiation at 5 kGy, commercial methyl bromide (MeBr), and phosphine fumigations. Electronic nose differentiated the volatile patterns of the WGP with each different preservative treatment. In addition, each volatile pattern was affected by both storage time (1, 2 and 5 months) and temperature (-10 and $25^{\circ}C$). After 5-months of storage, the least change of volatile patterns was observed from WGP fumigated with phosphine at $-10^{\circ}C$. The result also showed that volatile changes in WGP were much more affected by storage time than by storage temperature.

Quantitative Analysis of Lower Nose and Upper Lip Asymmetry in Patient with Unilateral Cleft Lip Nose Deformity using 3D camera (3D camera를 이용한 일측성 구순비변형환자에서의 비하부 및 상구순 비대칭의 정량적 분석)

  • Oh, Tae suk;Koh, Kyung suk;Kim, Tae gon
    • Archives of Plastic Surgery
    • /
    • v.36 no.6
    • /
    • pp.702-706
    • /
    • 2009
  • Purpose: Analysis of lower nose and upper lip asymmetry in patients with unilateral cleft lip nose deformity has been proceeded through direct measurement and photo analysis. But there are limitation in presenting real image because of its 2 dimensional trait. The authors analyzed such an asymmetry using 3D VECTRA system (Canfield, NJ, USA) in quantitative way. Methods: In 25 Patients with unilateral cleft lip nose deformity(male 12, female 13, age ranging from 4 to 19), patients with right side deformity were 10 and left were 15. Analysis of asymmetry was proceeded through 3D VECTRA system. After taking 3 dimensional photo, alar area, upper lip area, nostril perimeter, nostril area, Cupid's bow length, nostril height and nostril width were measured. Correlation coefficient and inter data quotients were calculated. Results: In nostril perimeter, maximal difference of cleft side and non - cleft side was 39.3%, asymmetric quotient Qasy = Qcl/Qncl(Qcl, value of cleft side; Qncl, value of non - cleft side) was ranged from 0.84 to 1.85 and in seven cases the length of cleft side was smaller. In nostril area, maximal difference was 69.6% and in 13 cases cleft side was smaller. In lower nasal area, maximal difference was 37.2% asymmetric quotient Qasy = Qcl/Qncl was ranged from 0.47 to 2.03 and in 20 cases cleft side was smaller. The correlation coefficients of nostril perimeter and area were 0.8345. Conclusion: Using 3D VECTRA system, the authors can measure nostril perimeter and lower nasal area that could not been measured with previous methods. Asymmetry of midface was analyzed through area comparison in quantitative way. Futhermore, post operative change can be measured in quantitative method.

Design Formula for Launching Nose of ILM Bridge Considering the Interaction Behavior with Superstructure Sections (상부단면과의 상호작용을 고려한 ILM 교량용 압출추진코의 최적화 설계식)

  • Lee, Hwan-Woo;Jang, Jae-Youp
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.23 no.1
    • /
    • pp.53-60
    • /
    • 2010
  • In constructing ILM(Incremental Launching Method) bridges, a launching nose is generally used in order to absorb temporary stress occurring during launching. The sectional forces of superstructure of ILM bridges, which occurs during launching, varies significantly according to the length, weight and stiffness of the launching nose. Thus in order to guarantee the safety of section of ILM bridges, the change of stress according to interaction behavior between launching nose and superstructure should be considered. However, the span division and span length are often decided based on previous cases in practice. It makes the design sections of launching nose are similar in spite of different projects. The designer's anxiety to optimize the launching nose to affect the optimum design of superstructure is also weak. In this study, an design formular to optimize the nose is proposed by using the analysis formular of nose-deck interaction and the design level of ILM bridges constructed on 00 Expressway is examined. According to the result of this study, the proposed design formulas are expected to make a significant contribution to section design that is economically efficient and at the same time guarantees the safety of the superstructure and launching noses of ILM bridges regardless of span length.

The Surface Roughness of Aluminium Material according to Cutting Conditions in the CNC Lathe Working (CNC 선반가공(旋盤加工)에서 절삭조건(切削條件)에 따른 알루미늄의 표면(表面)거칠기 변화(變化))

  • Kim, Tae-Wook;Son, Ki-Dong
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.5 no.3
    • /
    • pp.201-208
    • /
    • 2002
  • The machine tool which operates by hand is replacing by CNC machine tool to improve the quality of the product and the productivity in modem mechanic industry. The precision of machine part is influenced greatly the surface roughness by cutting condition of machine tool. So this study was performed to examine the aluminium surface roughness of section according to change of strength rating, nose radius, cutting speed, using live center. The results of this study are as follows; 1. In the case of 56mm diameter of test piece(length is below triple of diameter), whether establish the live center or not, doesn't influence to the surface roughness, and it is possible to make product without the live center. 2. The average surface roughness of 42mm diameter(length is quadruple of diameter) is similar to the 56mm diameter in the cutting condition of nose radius 0.8mm and cutting speed 140mm/min, but there are increases and differences in other cutting conditions. 3. In the case of test piece length more 70m/min(140m/mm) and nose radius improved greatly using the live center. 4. In the case of test piece length is quintuple of diameter, the nose radius must choose big tool and increase the cutting speed in preference live center establishment availability to improve that is surface roughness. Conclusively, if aluminum test piece length is fewer than triple of diameter, can process without establishing live center. If aluminum test piece length is more than quintuple of diameter, cutting conditions to improve surface roughness are (1) cutting speed (2) nose radius (3) whether the live center uses or not.

  • PDF

A simple method of intraoperative intubation tube change

  • Cho, Jin Yong;Kim, Hyeon Min;Ryu, Jae Young
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.40 no.5
    • /
    • pp.250-252
    • /
    • 2014
  • Nasotracheal intubation should be performed in patients with jaw fractures because maxillomandibular fixation is required. However, when there are concomitant fractures of the nose and facial bones, an intubation tube positioned at the nose makes it difficult to perform an intricate surgery. In order to overcome these problems, a variety of ways to change the position of the tube have been introduced. We describe a simple technique of switching the tube from a nasal to oral position, which was easily executed in a patient with concomitant nasal and mandibular fractures, accompanied by a literature review.

Discrimination of Rice Volatile Compounds under Different Milling Degrees and Storage Time Using an Electronic Nose (전자코를 이용한 도정 및 저장에 따른 쌀의 휘발성분 패턴 판별)

  • Han, Hyun Jung;Dong, Hyemin;Noh, Bong Soo
    • Korean Journal of Food Science and Technology
    • /
    • v.48 no.2
    • /
    • pp.187-191
    • /
    • 2016
  • The objective of this study was to analyze the volatile compounds in rice under various milling degrees using a mass spectrometry-based electronic nose and discriminant function analysis (DFA). Less volatile components were more frequently found in rice with a lower milling degree. Milling degree resulted in a shift of DF1 to the left side of the DFA plot. This indicated that the DF1 scores were correlated with the milling degree of rice. Brown rice was found to have more volatile components regardless of the milling degree. Thus, rice prepared at different milling degrees could be effectively discriminated with electronic nose analysis. Moreover, more volatile components were detected with an increase in storage time. A slight change in volatile components was found with an increase in the milling degree. The electronic nose could predict the milling degree and storage time of rice.