• Title/Summary/Keyword: normalized k

Search Result 2,395, Processing Time 0.029 seconds

Mobile Finger Signature Verification Robust to Skilled Forgery (모바일환경에서 위조서명에 강건한 딥러닝 기반의 핑거서명검증 연구)

  • Nam, Seng-soo;Seo, Chang-ho;Choi, Dae-seon
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.26 no.5
    • /
    • pp.1161-1170
    • /
    • 2016
  • In this paper, we provide an authentication technology for verifying dynamic signature made by finger on smart phone. In the proposed method, we are using the Auto-Encoder-based 1 class model in order to effectively distinguish skilled forgery signature. In addition to the basic dynamic signature characteristic information such as appearance and velocity of a signature, we use accelerometer value supported by most of the smartphone. Signed data is re-sampled to give the same length and is normalized to a constant size. We built a test set for evaluation and conducted experiment in three ways. As results of the experiment, the proposed acceleration sensor value and 1 class model shows 6.9% less EER than previous method.

Quantitative Comparison of the Photocatalytic Efficiency of TiO2 Nanotube Film and TiO2 Powder

  • Jang, Jun-Won;Park, Sung Jik;Park, Jae-Woo
    • Journal of Soil and Groundwater Environment
    • /
    • v.21 no.2
    • /
    • pp.8-14
    • /
    • 2016
  • We compared the plausible reaction mechanism and quantitative efficiency of highly self-organized TiO2 nanotube (ntTiO2) film with TiO2 powder. Film was fabricated by electrochemical potentiostatic anodization of titanium thin film in an ethylene-glycol electrolyte solution containing 0.3 wt% NH4F and 2 vol% deionized water. Nanotubes with a pore size of 80-100 nm were formed by anodization at 60 V for 3 h. Humic acid (HA) was degraded through photocatalytic degradation using the ntTiO2 film. Pseudo first-order rate constants for 0.3 g of ntTiO2, 0.3 g TiO2 powder, and 1 g TiO2 powder were 0.081 min−1, 0.003 min−1, and 0.044 min−1, respectively. HA adsorption on the ntTiO2 film was minimal while adsorption on the TiO2 powder was about 20% based on thermogravimetric analysis. Approximately five-fold more normalized OH radicals were generated by the ntTiO2 film than the TiO2 powder. These quantitative findings explain why ntTiO2 film showed superior photocatalytic performance to TiO2 powder.

The Effect of Neck Assistive Device Considering Mckenzie Type Subjects with Forward Head Posture

  • Lee, Han-Suk;Lee, Woo-Cheol;Kim, Joon-Ho
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.10 no.2
    • /
    • pp.89-94
    • /
    • 2015
  • PURPOSE: The aim of this study was to determine the effect of device considering Mckenzie type for the subjects with forward head posture (FHP). METHODS: The subjects were 35 patients with FHP (mean age was $23.7{\pm}2.8$ years; mean height; $172.1{\pm}11.7$, mean weight; $65.8{\pm}13.9$, mean NDI(Neck Disability Index; $3.7{\pm}3.2$, mean FHP; $6.7{\pm}2.2$). We measured the posture with the Body style S-8.0(LU Commerce, South Korea) to evaluate the FHP. We collected the surface EMG(Myosystem 1400, Noraxon, USA) data to quantify changes in normalized activation levels of muscles in SternoCleidoMastoid muscle(SCM), Scalenus Anterior(SA), Trapezius upper fiber(TU) and Splenius Cervicis(SC), during the subjects were instructed to glide their head into a "chin-in" position for a retraction without and with device. RESULTS: The condition with device significantly decreased the %RVC of SA($90.84{\pm}40.54$), SCM($74.98{\pm}43.65$) and TU($67.60{\pm}47.83$) compared to the condition without device(SA;$100.39{\pm}56.32$, SCM;$119.03{\pm}109.26$, Trapezius;$80.55{\pm}39.27$). But the %RVC of capitis($65.87{\pm}47.83$) with device was increased($70.82{\pm}52.78$). There was significant difference in the %RVC between SCM and Trapezius muscle in two conditions. CONCLUSION: New device for FHP reduces the EMG activities of the TU, SCM and SA muscle. We have to develop the function of feedback to facilitate the motion in the future.

Quantitative Evaluation of Remote Field Eddy Current Defect Signals (배관 결함부 원거리장 와전류 신호 정량화 연구)

  • Jeong, Jin-Oh;Yi, Jae-Kyung;Kim, Hyoung-Jean
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.6
    • /
    • pp.555-561
    • /
    • 2000
  • The remote field eddy current (RFEC) inspection was performed on the ductile cast iron pipes with nominal outer diameter of 100mm, which were machined with various shapes and sizes of defects. Ductile cast iron pipes which are used as water supply pipe have the non-uniform thickness and asymmetric cross section due to relatively high degree of allowable errors during the manufacturing processes. These characteristics of ductile cast in pipes cause the long range background noises in RFEC signals along the pipe. In this study, tile machined defects in pipes were effectively classified by the moving window average (MWA) method which eliminated the long-range noise. The voltage plane polar plots (VPPP) method was used to quantitatively evaluate the depth and circumferential degree of defects. The VPPP signatures showed that the angle between defect signature and the normalized in-phase component on the VPPP is linear to the depth of defects. The nondestructive RFEC technique proved to be capable of quantitatively evaluating the machined defects of underground water supply pipe.

  • PDF

Some issues on the downscaling of global climate simulations to regional scales

  • Jang, Suhyung;Hwang, Manha;Hur, Youngteck;Kavvas, M. Levent
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.229-229
    • /
    • 2015
  • Downscaling is a fundamental procedure in the assessment of the future climate change impact at regional and watershed scales. Hence, it is important to investigate the spatial variability of the climate conditions that are constructed by various downscaling methods in order to assess whether each method can model the climate conditions at various spatial scales properly. This study introduces a fundamental research from Jang and Kavvas(2015) that precipitation variability from a popular statistical downscaling method (BCSD) and a dynamical downscaling method (MM5) that is based on the NCAR/NCEP reanalysis data for a historical period and on the CCSM3 GCM A1B emission scenario simulations for a projection period, is investigated by means of some spatial characteristics: a) the normalized standard deviation (NSD), and b) the precipitation change over Northern California region. From the results of this study it is found that the BCSD method has limitations in projecting future precipitation values since the BCSD-projected precipitation, being based on the interpolated change factors from GCM projected precipitation, does not consider the interactions between GCM outputs and local geomorphological characteristics such as orographic effects and land use/cover patterns. As such, it is not clear whether the popular BCSD method is suitable for the assessment of the impact of future climate change at regional, watershed and local scales as the future climate will evolve in time and space as a nonlinear system with land-atmosphere feedbacks. However, it is noted that in this study only the BCSD procedure for the statistical downscaling method has been investigated, and the results by other statistical downscaling methods might be different.

  • PDF

Bearing Faults Identification of an Induction Motor using Acoustic Emission Signals and Histogram Modeling (음향 방출 신호와 히스토그램 모델링을 이용한 유도전동기의 베어링 결함 검출)

  • Jang, Won-Chul;Seo, Jun-Sang;Kim, Jong-Myon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.11
    • /
    • pp.17-24
    • /
    • 2014
  • This paper proposes a fault detection method for low-speed rolling element bearings of an induction motor using acoustic emission signals and histogram modeling. The proposed method performs envelop modeling of the histogram of normalized fault signals. It then extracts and selects significant features of each fault using partial autocorrelation coefficients and distance evaluation technique, respectively. Finally, using the extracted features as inputs, the support vector regression (SVR) classifies bearing's inner, outer, and roller faults. To obtain optimal classification performance, we evaluate the proposed method with varying an adjustable parameter of the Gaussian radial basis function of SVR from 0.01 to 1.0 and the number of features from 2 to 150. Experimental results show that the proposed fault identification method using 0.64-0.65 of the adjustable parameter and 75 features achieves 91% in classification performance and outperforms conventional fault diagnosis methods as well.

Growth and Characterization of InGaP/InGaAs p-HEMI Using Compound Source MBE (Compound Source MBE를 이용한 InGaP/InGaAs p-HEMT 구조의 성장 및 특성 분석)

  • Kim, J.H.;S.J. Kang;S.J. Jo;J.D. Song;Lee, Y.T.;J.I. Song
    • Proceedings of the IEEK Conference
    • /
    • 2000.06b
    • /
    • pp.16-19
    • /
    • 2000
  • DC and low frequency noise characteristics of InGaP/InGaAs pseudomorphic HEMTs (p-HEMTs) grown by compound source MBE are investigated for temperature range of 150K to 370K. Equivalent input noise spectra( $S_{iv}$ ) were measured as a function of frequency and temperature. $S_{iv}$ was measured to be 3.4 $\times$ 10$^{-12}$ $V^2$/ Hz at 1kHz for 1.3 X 50${\mu}{\textrm}{m}$$^2$InGaP/InGaAs p-HEMT at room temperature. Measurements of the low-frequency noise spectra of the p-HEMT as a function of temperature show that the trap with an activation energy level around 0.589 eV is a dominant trap that accounts for the low-frequency noise behavior of the device. The normalized extrinsic gm frequency dispersion of the p-HEMT. was as low as 2.5% at room temperature, indicating that the device has well-behaved low-frequency noise characteristics. Sub-micron (0.25 $\times$ 50${\mu}{\textrm}{m}$$^2$) gate p-HEMT showed $f_{T}$ and $f_{max}$ of 40GHz and 108GHz, respectively.y.y.

  • PDF

Comparison of Therapeutic Efficacy between Lamivudine and Alpha-Interferon in Korean Children with Chronic Hepatitis B at Two Years after the Initiation of Treatment (소아 만성 B형 간염 환아에서 라미부딘과 알파 인터페론의 치료효과 비교 : 치료 시작 후 2년 경과 시점 비교)

  • Choe, Byung-Ho;Jang, You Cheol;Jang, Chang Hwan;Oh, Ki Won;Lee, Jun Hwa;Ko, Cheol Woo
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.1
    • /
    • pp.55-62
    • /
    • 2005
  • Purpose : We compared the therapeutic efficacy of lamivudine and alpha-interferon in children with chronic hepatitis B two years after the initiation of treatment, so that we could verify the safety and long term efficacy of lamivudine in children. Methods : We prospectively studied 44 children(32 male and 12 female; age, 1-18 years, mean, 9 years) treated for chronic hepatitis B from September 1996 to June 2004 in Kyungpook National University Hospital in Korea. Twenty three children were treated with interferon, and 21 with lamivudine. Treatment efficacy was defined as the normalization of ALT and hepatitis B virus(HBV) DNA levels, loss of HBsAg and HBeAg seroconversion at two years after the initiation of treatment. Results : Among the 23 children treated with interferon, the ALT level normalized in 10 children(43 %) and HBV DNA was undetectable in 12 children(52%). HBsAg was undetectable in one child (4 %) and HBeAg seroconversion occurred in nine children(39%) two years after the initiation of treatment. In comparison, among the 21 children treated with lamivudine, ALT normalized in 20 children (95%), HBV DNA in 19(90%), HBsAg in 5(24%), and HBeAg seroconversion occurred in 13(62%). Above all, in the lamivudine treated group under the age of seven, HBeAg and HBsAg seroconversion occurred in six(75%) and five(63%) out of the eight children respectively, which showed superior HBsAg seroconversion rate if treated in preschool aged children. Conclusion : We believe that the therapeutic efficacy of lamivudine in children with chronic hepatitis B could be better than interferon with fewer side effects, especially in preschool aged children.

Improvement of Radar Rainfall Estimation Using Radar Reflectivity Data from the Hybrid Lowest Elevation Angles (혼합 최저고도각 반사도 자료를 이용한 레이더 강우추정 정확도 향상)

  • Lyu, Geunsu;Jung, Sung-Hwa;Nam, Kyung-Yeub;Kwon, Soohyun;Lee, Cheong-Ryong;Lee, Gyuwon
    • Journal of the Korean earth science society
    • /
    • v.36 no.1
    • /
    • pp.109-124
    • /
    • 2015
  • A novel approach, hybrid surface rainfall (KNU-HSR) technique developed by Kyungpook Natinal University, was utilized for improving the radar rainfall estimation. The KNU-HSR technique estimates radar rainfall at a 2D hybrid surface consistings of the lowest radar bins that is immune to ground clutter contaminations and significant beam blockage. Two HSR techniques, static and dynamic HSRs, were compared and evaluated in this study. Static HSR technique utilizes beam blockage map and ground clutter map to yield the hybrid surface whereas dynamic HSR technique additionally applies quality index map that are derived from the fuzzy logic algorithm for a quality control in real time. The performances of two HSRs were evaluated by correlation coefficient (CORR), total ratio (RATIO), mean bias (BIAS), normalized standard deviation (NSD), and mean relative error (MRE) for ten rain cases. Dynamic HSR (CORR=0.88, BIAS= $-0.24mm\;hr^{-1}$, NSD=0.41, MRE=37.6%) shows better performances than static HSR without correction of reflectivity calibration bias (CORR=0.87, BIAS= $-2.94mm\;hr^{-1}$, NSD=0.76, MRE=58.4%) for all skill scores. Dynamic HSR technique overestimates surface rainfall at near range whereas it underestimates rainfall at far ranges due to the effects of beam broadening and increasing the radar beam height. In terms of NSD and MRE, dynamic HSR shows the best results regardless of the distance from radar. Static HSR significantly overestimates a surface rainfall at weaker rainfall intensity. However, RATIO of dynamic HSR remains almost 1.0 for all ranges of rainfall intensity. After correcting system bias of reflectivity, NSD and MRE of dynamic HSR are improved by about 20 and 15%, respectively.

Early Management of Total Parenteral Nutrition Induced Hepatic Dysfunction with Cyclic Parenteral Nutrition (정맥영양 관련 간기능 장애에서 조기 주기성 정맥영양법의 유용성)

  • Lee, Sung Soo;Chang, Ju Young;Yang, Hye Ran;Ko, Jae Sung;Choi, Kyung Hee;Seo, Jeong Kee
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.7 no.1
    • /
    • pp.61-73
    • /
    • 2004
  • Purpose: Liver function test abnormalities have been reported frequently in patients receiving total parenteral nutrition (TPN). In adults, it is known that liver complications decrease with the use of cyclic parenteral nutrition (CPN), especially if the shift to cycling was not too late. However, there are few studies about the effects of cycling on liver injury in children beyond the neonatal period. The aim of this study is to evaluate the effect of the early use of CPN on total parenteral nutrition induced hepatic dysfunction. Methods: Twelve sets of CPN in 11 children (2 months to 17 years) were included in this study. Data on underlying diseases, age, length of time on TPN, macronutrient intake, complications, and biochemical parameters were collected from clinical records. All children had received CPN in the early period of persistent transaminase elevation or cholestasis complicated by previous continuous PN. The duration of infusion off-time in CPN was 2 hours in patients less than 3 months of age and 4 hours in the older children. Results: All 12 cases showed elevated aminotransferase and 5 of them also showed cholestasis. Serum total bilirubin concentration was normalized in all 5 cases with median periods of 8 days (p<0.05) after initiation of CPN. ALT either decreased significantly or was normalized in all cases with median periods of 30 days (p<0.05) on CPN. The CPN was well tolerated without significant complication except for one case of hyperglycemia. Conclusion: The early use of cyclic parenteral nutrition had a beneficial effect in improving hepatic dysfunction complicated by TPN in children.

  • PDF