• Title/Summary/Keyword: normalized correlation coefficient

Search Result 108, Processing Time 0.032 seconds

The GOCI-II Early Mission Marine Fog Detection Products: Optical Characteristics and Verification (천리안 해양위성 2호(GOCI-II) 임무 초기 해무 탐지 산출: 해무의 광학적 특성 및 초기 검증)

  • Kim, Minsang;Park, Myung-Sook
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.5_2
    • /
    • pp.1317-1328
    • /
    • 2021
  • This study analyzes the early satellite mission marine fog detection results from Geostationary Ocean Color Imager-II (GOCI-II). We investigate optical characteristics of the GOCI-II spectral bands for marine fog between October 2020 and March 2021 during the overlapping mission period of Geostationary Ocean Color Imager (GOCI) and GOCI-II. For Rayleigh-corrected reflection (Rrc) at 412 nm band available for the input of the GOCI-II marine fog algorithm, the inter-comparison between GOCI and GOCI-II data showed a small Root Mean Square Error (RMSE) value (0.01) with a high correlation coefficient (0.988). Another input variable, Normalized Localization Standard (NLSD), also shows a reasonable correlation (0.798) between the GOCI and GOCI-II data with a small RMSE value (0.007). We also found distinctive optical characteristics between marine fog and clouds by the GOCI-II observations, showing the narrower distribution of all bands' Rrc values centered at high values for cloud compared to marine fog. The GOCI-II marine fog detection distribution for actual cases is similar to the GOCI but more detailed due to the improved spatial resolution from 500 m to 250 m. The validation with the automated synoptic observing system (ASOS) visibility data confirms the initial reliability of the GOCI-II marine fog detection. Also, it is expected to improve the performance of the GOCI-II marine fog detection algorithm by adding sufficient samples to verify stable performance, improving the post-processing process by replacing real-time available cloud input data and reducing false alarm by adding aerosol information.

Comparison Analysis of Vegetation Index and Degree of Green Naturality (식생지수와 녹지자연도의 비교평가)

  • Han, Eui-Jung;Kim, Myung-Jin;Hong, Jun-Suk;Seo, Chang-Wan
    • Journal of Environmental Impact Assessment
    • /
    • v.6 no.2
    • /
    • pp.181-188
    • /
    • 1997
  • Vegetation is an important factor in EIA(Environmental Impact Assessment) and it is assessed according to DGN(Degree of Green Naturality) in EIS(Environmental Impact Statement) preparation. But DGN has room for improvement of assessing vegetation Status. This study introduced NDVI(Normalized Difference Vegetation Index) for improving status assessment method that subjects to DGN. For the application of NDVI, Landsat TM data of Chunchon on May 2, 1989 and June 1, 1994, and data of Ulsan on November 5, 1984, November 2, 1992 and May 9, 1994 were used. It compared NDVI with DGN according to season and location. The correlation coefficient value for the spring image (1994, 0.7, p=0.01) was proved to be higher than that of autumn (1984, 0.5, p=0.01).

  • PDF

Mapping Herbage Biomass on a Hill Pasture using a Digital Camera with an Unmanned Aerial Vehicle System

  • Lee, Hyowon;Lee, Hyo-Jin;Jung, Jong-Sung;Ko, Han-Jong
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.35 no.3
    • /
    • pp.225-231
    • /
    • 2015
  • Improving current pasture productivity by precision management requires practical tools to collect site specific pasture biomass data. Recent developments in unmanned aerial vehicle (UAV) technology provide cost effective and real time applications for site specific data collection. For the mapping of herbage biomass (BM) on a hill pasture, we tested a UAV system with digital cameras (visible and near-infrared (NIR) camera). The field measurements were conducted on the grazing hill pasture at Hanwoo Improvement Office, Seosan City, Chungcheongnam-do Province, Korea on May 17 and June 27, 2014. Plant samples were obtained from 28 sites. A UAV system was used to obtain aerial photos from a height of approximately 50 m (approximately 30 cm spatial resolution). Normalized digital number (DN) values of Red and NIR channels were extracted from the aerial photos and a normalized differential vegetation index using DN ($NDVI_{dn}$) was calculated. The results show that the correlation coefficient between BM and $NDVI_{dn}$ was 0.88. For the precision management of hilly grazing pastures, UAV monitoring systems can be a quick and cost effective tool to obtain site-specific herbage BM data.

Intercomparison of interannual changes in NDVI from PAL and GIMMS in relation to evapotranspiration over northern Asia

  • Suzuki Rikie;Masuda Kooiti;Dye Dennis
    • Proceedings of the KSRS Conference
    • /
    • 2004.10a
    • /
    • pp.162-165
    • /
    • 2004
  • The authors' previous study found an interannual covariability between actual evapotranspiration (ET) and the Normalized Difference Vegetation Index (NDVI) over northern Asia. This result suggested that vegetation controls interannual variation in ET. In this prior study, NDVI data from the Pathfinder AVHRR Land (PAL) dataset were analyzed. However, studies of NDVI interannual change are subject to uncertainty, because NDVI data often contain errors associated with sensor- and atmosphere-related effects. This study is aimed toward reducing this uncertainty by employing NDVI dataset, from the Global Inventory Monitoring and Modeling Studies (GIMMS) group, in addition to PAL. The analysis was carried out for the northern Asia region from 1982 to 2000. 19-year interannual change in PAL-NDVI and GIMMS-NDVI were both compared with interannual change in model-assimilated ET. Although the correlation coefficient between GIMMS-NDVI and ET is slightly less than for PAL-NDVI and ET, for both NDVI datasets the annual maximum correlation with ET occurs in June, which is near the central period of the growing season. A significant positive correlation between GIMMS-NDVI and ET was observed over most of the vegetated land area in June as well as PAL-NDVI and ET. These results reinforce the authors' prior research that indicates the control of interannual change in ET is dominated by interannual change in vegetation activity.

  • PDF

Identification of Whipping Response using Wavelet Cross-Correlation (웨이블릿 교차상관관계를 이용한 변형체 선박의 휘핑 응답 식별)

  • Kim, Yooil;Kim, Jung-Hyun;Kim, Yonghwan
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.51 no.2
    • /
    • pp.122-129
    • /
    • 2014
  • Identification of the whipping response out of the combined wave-vibration response of a flexible sea going vessel is one of the most interesting research topic from ship designer's point of view. In order to achieve this goal, a novel methodology based on the wavelet cross-correlation technique was proposed in this paper. The cross-correlation of the wavelet power spectrum averaged across the frequency axis was introduced to check the similarity between the combined wave-vibration response and impulse response. The calculated cross-correlation of the wavelet power spectrum was normalized by the auto-correlation of the each spectrum with zero time lag, eventually providing the cross-correlation coefficient that stays between 0 and 1, precisely indicating the existence of the impulse response buried in the combined wave-vibration response. Additionally, the weight function was introduced while calculating the cross-correlation of the two spectrums in order to filter out the signal of lower frequency so that the accuracy of the similarity check becomes as high as possible. The validity of the proposed methodology was checked through the application to the artificially generated ideal combined wave-vibration signal, together with the more realistic signal obtained by running 3D hydroelasticity program WISH-Flex. The correspondence of the identified whipping instances between the results, one from the proposed method and the other from the calculated slamming modal force, was excellent.

Displacement Measurement of Cable Stayed Bridge using Digital Image Processing (디지털 영상처리를 이용한 사장교의 변위 측정)

  • Son, Byung Jik;Jeon, Seung Gon;Heo, Gwang Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.237-242
    • /
    • 2016
  • This paper introduces a method of measuring the displacement of a cable-stayed bridge using digital image processing (DIP). The validity of the DIP technique was confirmed by comparing the results with those obtained using a displacement meter and ANSYS analysis. The normalized cross-correlation (NCC) coefficient was used. 100 kgf and 200 kgf loading experiments were carried out, which showed that when the displacement is large, the reliability of the DIP technique is increased. That is, when the load was increased from 100 kgf to 200kgf, it decreased from 31% to 14% compared to the ANSYS results and from 14% to 4% compared to the displacement meter results. Therefore, the image processing method is able to measure the displacement sufficiently accurately.

APPLICATION STUDY OF CHEMOINFOMETRICAL NEAR-INFRARED SPECTROSCOPY IN PHARMACEUTICAL INDUSTRY

  • Otsuka, Makoto;Kato, Fumie;Matsuda, Yoshihisa
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.2111-2111
    • /
    • 2001
  • A chemoinfometrical method for evaluating the quantitative determination of crystallinity one polymorphs based on fourie-transformed near-infrared (FT-NIR) spectroscopy was established. A direct comparison of the data with the ones collected from using the and compared with the conventional powder X-ray diffraction method was performed. [Method] The pPure a and g forms of indomethacin (IMC) were prepared by reportedusing published methods. Six kinds of standard samples obtained by physically mixing of a and g forms. After the powder X-ray diffraction profiles of samples have been measured, the intensity values were normalized to against the intensity of silicon powder as the as an external standard. The calibration curves for quantification of crystal content were based upon the total relative intensity of four diffraction peaks from of the form g crystal. FT-NIR spectra of six calibration sample sets were recorded 5 times with the NIR spectrometer (BRAN+LUEBBE). Chemoinfometric analysis was performed on the NIR spectral data sets by applying the principal component regression (PCR). [Results] The relation between the actual and predicted polymorphic contents of form g IMC measured using by the X-ray diffraction method shows a good straight linen linear relation., and it has slope of 0.023, an intercept of 0.131 and a correlation coefficient of 0.986. PCR analyses wereis was performed based on normalized NIR spectra sets offer standard samples of known content of IMC g form. IMC. A calibration equation was determined to minimize the root mean square error of the predictionthe prediction. Figure 1 shows a plot of the calibration data obtained by NIR method between the actual and predicted contents of form g IMC. The predicted values were reproducible and had a smaller standard deviation. Figure 2 shows that the plot for the predicted transformation rate (%) of form a IMC to form g as measured by X-ray diffractomeoy against to those as measured by NIR method. The plot has a slope of 1.296, an intercept of 1,109, and a correlation coefficient of 0.992. The line represents a satisfactory correlation between the two predicted values of form g IMC content. Thus NIR spectroscopy is an effective method for the evaluation to the pharmaceutical products of quantitative of polymorph.

  • PDF

Performance of ISC model-Predicting short-term concentrations around waste incinerator plant (ISC모델의 적용성 평가 - 소각장 주변지역의 단기농도예측)

  • 정상진
    • Journal of Environmental Science International
    • /
    • v.12 no.7
    • /
    • pp.809-816
    • /
    • 2003
  • The short-term version of Industrial Source Complex Model(ISCST3) was evaluated for estimating short-term concentrations using criteria pollutant(SO$_2$, NO$_2$, CO, PM10) data from emission inventory of Young Tong area in Suwon for the year 2002. The contribution of pollutant concentration from point, line, area sources was found 21.8, 76.5 and 1.6%. Statistical parameters, such as correlation coefficient, index of agreement(IA), normalized mean square error(NMSE) and fractional bias(FB) were calculated for each pollutants. The model performance were found good for PM10(82%) and NO$_2$(69%), but poor for SO$_2$(34%) and CO(13%).

Displacement Measurement of Pylon using Image Processing Technique (영상처리 기법을 이용한 주탑의 변위 측정)

  • Son, Byung Jik;Jeon, Seung Gon;Heo, Gwang Hee
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.6 no.3
    • /
    • pp.20-25
    • /
    • 2015
  • This paper introduces a digital image processing(DIP) method as a method for measuring the displacement of pylon. The comparison of DIP results and ANSYS analysis results verified the validity of the image processing technique. Normalized cross-correlation(NCC) coefficient was used and experiments were performed three times. It shows that the displacement difference was 22% and 5% compared to ANSYS results. Therefore, the image processing method is expected to be able to measure the displacement of pylon sufficiently.

Implementation of 4 Channel Photo-Plethysmogram System(I) (4 채널의 Photo-plethysmogram 시스템 구현에 관한 연구(I))

  • Kim, Hyoung-Tae;Han, Soon-Chen;Kim, Jung-Kuk;Huh, Woong;Park, Young-Bae
    • Proceedings of the IEEK Conference
    • /
    • 2002.06e
    • /
    • pp.253-256
    • /
    • 2002
  • In this paper, we implement the volume pulse detection system which can quantitatively represent an artery elasticity. The system consists of transducer which has IRLED-photodiode detecter, temperature sensor, filters, preprocessing circuits, A/D converter, serial communication part and computer system. In order to presume the artery elasticity information we measure the volume pulse at four points and then evaluate the transition time, distance and the correlation coefficient of the pulse wave between the points. We test the system with 10 subjects during the week for basic experiment and obtain the data at four points. As the result of experiment, we can detect normalized volume pulse wave and evaluated parameter with effectively.

  • PDF