• 제목/요약/키워드: normal temperature

검색결과 2,451건 처리시간 0.026초

2.2 kW와 3.7 kW 유도전동기의 정상과 구속운전에 따른 전류 및 온도 특성 (Characteristic of Current and Temperature according to Normal and Abnormal Operations at Induction Motor of 2.2 kW and 3.7 kW)

  • 이종찬;김두현;김성철
    • 한국안전학회지
    • /
    • 제38권3호
    • /
    • pp.35-42
    • /
    • 2023
  • This study analyzed the current and temperature characteristics of major components of an induction motor during normal and abnormal operations as functions of the difference in the rated capacities of medium and large-sized motors widely used in industrial settings. The temperature rise equation of the induction motor winding was derived through locked-rotor operation experiments and linear regression analysis. When the ambient temperature is 40 ℃, the time to reach 155 ℃, the temperature limit of the insulation class (F class) of the winding of the induction motor, was confirmed to be 48 seconds for the 2.2 kW induction motor and 39 seconds for the 3.7 kW induction motor. This means that when the rated capacity is large or the installation environment is high temperature, the time to reach the temperature limit of the insulation class during locked-rotor operation is short, and the risk of insulation deterioration and fire is high. In addition, even if the EOCR (Electronic Over Current Relay) is installed, if the setting time is excessively set, the EOCR does not operate even if the normal and locked-rotor operation of the induction motor is repeated, and the temperature limit of the insulation grade of the winding of the induction motor is exceeded. The results of this study can be used for preventive measures such as the promotion of electrical and mechanical measures for the failure of induction motors and fire prevention in industrial sites, or the installation of fire alarm systems.

The Effectiveness of Infrared Thermography in Patients with Whiplash Injury

  • Lee, Young Seo;Paeng, Sung Hwa;Farhadi, Hooman F.;Lee, Won Hee;Kim, Sung Tae;Lee, Kun Su
    • Journal of Korean Neurosurgical Society
    • /
    • 제57권4호
    • /
    • pp.283-288
    • /
    • 2015
  • Objective : This study aims to visualize the subjective symptoms before and after the treatment of whiplash injury using infrared (IR) thermography. Methods : IR thermography was performed for 42 patients who were diagnosed with whiplash injury. There were 19 male and 23 female patients. The mean age was 43.12 years. Thermal differences (${\Delta}T$) in the neck and shoulder and changes in the thermal differences (${\Delta}dT$) before and after treatment were analyzed. Pain after injury was evaluated using visual analogue scale (VAS) before and after treatment (${\Delta}VAS$). The correlations between ${\Delta}dT$ and ${\Delta}VAS$ results before and after the treatment were examined. We used Digital Infrared Thermal Imaging equipment of Dorex company for IR thermography. Results : The skin temperature of the neck and shoulder immediately after injury showed $1-2^{\circ}C$ hyperthermia than normal. After two weeks, the skin temperature was normal range. ${\Delta}T$ after immediately injuy was higher than normal value, but it was gradually near the normal value after two weeks. ${\Delta}dT$ before and after treatment were statistically significant (p<0.05). VAS of the neck and shoulder significantly reduced after 2 week (p=0.001). Also, there was significant correlation between ${\Delta}dT$ and reduced ${\Delta}VAS$ (the neck; r=0.412, p<0.007) (the shoulder; r=0.648, p<0.000). Conclusion : The skin temperature of sites with whiplash injury is immediately hyperthermia and gradually decreased after two weeks, finally it got close to normal temperature. These were highly correlated with reduced VAS. IR thermography can be a reliable tool to visualize the symptoms of whiplash injury and the effectiveness of treatment in clinical settings.

HEAT REMOVAL TEST USING A HALF SCALE STORAGE CASK

  • Bang, K.S.;Lee, J.C.;Seo, K.S.;Cho, C.H.;Lee, S.J.;Kim, J.M.
    • Nuclear Engineering and Technology
    • /
    • 제39권2호
    • /
    • pp.143-148
    • /
    • 2007
  • Spent nuclear fuel generated at nuclear power plants must be safely stored during interim storage periods. A dry storage cask to safely store the spent nuclear fuel should be able to adequately emit the decay heat from the spent nuclear fuel. Therefore, heat removal tests using a half scale dry storage cask have been performed to estimate the heat transfer characteristics of a dry storage cask under normal, off-normal, and accident conditions. In the normal condition, the heat transfer rate to an ambient atmosphere by convective air through a passive heat removal system reached 83%. Accordingly, the passive heat removal system is designed well and works adequately. In the off-normal condition, the influence of a half blockage in the inlet on the temperature appears minimal. In the accident condition, the temperature rose for 12 hours after the accident, but the temperature rise steadied after 36 hours.

Prediction models of the shear modulus of normal or frozen soil-rock mixtures

  • Zhou, Zhong;Yang, Hao;Xing, Kai;Gao, Wenyuan
    • Geomechanics and Engineering
    • /
    • 제15권2호
    • /
    • pp.783-791
    • /
    • 2018
  • In consideration of the mesoscopic structure of soil-rock mixtures in which the rock aggregates are wrapped by soil at normal temperatures, a two-layer embedded model of single-inclusion composite material was built to calculate the shear modulus of soil-rock mixtures. At a freezing temperature, an interface ice interlayer was placed between the soil and rock interface in the mesoscopic structure of the soil-rock mixtures. Considering that, a three-layer embedded model of double-inclusion composite materials and a multi-step multiphase micromechanics model were then built to calculate the shear modulus of the frozen soil-rock mixtures. Given the effect of pore structure of soil-rock mixtures at normal temperatures, its shear modulus was also calculated by using of the three-layer embedded model. Experimental comparison showed that compared with the two-layer embedded model, the effect predicted by the three-layer embedded model of the soil-rock mixtures was better. The shear modulus of the soil-rock mixtures gradually increased with the increase in rock regardless of temperature, and the increment rate of the shear modulus increased rapidly particularly when the rock content ranged from 50% to 70%. The shear modulus of the frozen soil-rock mixtures was nearly 3.7 times higher than that of the soil-rock mixtures at a normal temperature.

말에서 체열찰영술의 적용에 관한 연구 (Application of Thermography in Thoroughbred Horses)

  • 양영진;조길재;손원근;남치주
    • 한국임상수의학회지
    • /
    • 제19권2호
    • /
    • pp.139-146
    • /
    • 2002
  • The purpose of this study was to construct fundamental information for the usefulness and effects of thermography in Thoroughbred horses. total 10 horses were examined to determine a normal thermal pattern before and after sedation in lower limbs and ophthalmic area, and to investigate the effects of thermography during 42 days after induced wound and arthritis. In normal horses, the range of temperature difference(${\Delta}T$) of symmetry site in lower limbs was 0.20 to $0.68^{\circ}C$ on pre-sedation, which was simillar to that of post sedation, 0.17 to $0.74^{\circ}C$, and eyeball area was 0.34 to $0.68^{\circ}C$. Thermographically, the warmest area in normal limbs were coronary band of frontal view and the region between heel bulbs of back view. And temperature difference(${\Delta}T$) after clipping in left forelimb was increased 1 to $3^{\circ}C$ more than before clipping. However, there was no significant change of the temperature difference and degree of clinical signs by the process of inflammation healing during the experiment period in the all groups. These results suggest that the thermography was especially helpful in following clinical course of a disease because the thermal pattern will return to normal with declining clinical signs and healing of the lesion.

Study of moxibustion stimulation in the ovariectomized rat model

  • Kanai, Shigeyuki;Taniguchi, Norimasa;Kanda, Kayo;Matsuhata, Izuru
    • Advances in Traditional Medicine
    • /
    • 제5권3호
    • /
    • pp.195-200
    • /
    • 2005
  • In order to examine the effectiveness of moxibustion stimulation for climacteric disturbance, we administered moxibustion stimulation to ovariectomized (OVX) rats, and compared the tail surface temperature, laboratory parameters, and the level of locomotor activity with those of untreated rats. Twenty-four female Wistar rats (8 weeks old, 160 - 180 g) were divided into three groups. The rats in the OVX-M group underwent moxibustion stimulation after ovariectomy. The rats in the OVX-C group underwent ovariectomy but did not receive moxibustion stimulation. The rats in the Normal group received neither ovariectomy nor moxibustion stimulation. The level of locomotor activity was determined by a metabolism measuring system. The tail surface temperature was significantly lower in the OVX rats before moxibustion stimulation than in the Normal group. In the OVX rats before moxibustion stimulation, there was no clear difference in the level of locomotor activity between the active and resting phases, and the pattern of locomotor activity was irregular. After moxibustion stimulation, the tail surface temperature of the OVX-M group did not significantly differ from that of the Normal group, and the pattern of locomotor activity of the OVX-M group became diphasic with clear active and resting phases, similar to that observed in the Normal group. These results demonstrate that moxibustion stimulation is effective for the treatment of climacteric disturbance.

Investigation on effect of neutron irradiation on welding residual stresses in core shroud of pressurized water reactor

  • Jong-Sung Kim;Young-Chan Kim;Wan Yoo
    • Nuclear Engineering and Technology
    • /
    • 제55권1호
    • /
    • pp.80-99
    • /
    • 2023
  • This paper presents the results of investigating the change in welding residual stresses of the core shroud, which is one of subcomponents in reactor vessel internals, performing finite element analysis. First, the welding residual stresses of the core shroud were calculated by applying the heat conduction based lumped pass technique and finite element elastic-plastic stress analysis. Second, the temperature distribution of the core shroud during the normal operation was calculated by performing finite element temperature analysis considering gamma heating. Third, through the finite element viscoelastic-plastic stress analysis using the calculated temperature distribution and setting the calculated residual stresses as the initial stress state, the variation of the welding residual stresses was derived according to repeating the normal operation. In the viscoelastic-plastic stress analysis, the effects of neutron irradiation on mechanical properties during the cyclic normal operations were considered by using the previously developed user subroutines for the irradiation agings such as irradiation hardening/embrittlement, irradiation-induced creep, and void swelling. Finally, the effect of neutron irradiation on the welding residual stresses was analysed for each irradiation aging. As a result, it is found that as the normal operation is repeated, the welding residual stresses decrease and show insignificant magnitudes after the 10th refueling cycle. In addition, the irradiation-induced creep/void swelling has significant mitigation effect on the residual stresses whereas the irradiation hardening/embrittlement has no effect on those.

산화물 초전도선재의 상전도전파특성 (Normal-zone Propagation Properties in Oxide Superconductors)

  • 김석범;석산돈사;한경희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.41-43
    • /
    • 1996
  • This paper describes on concerning electromagnetical and thermal behaviors during normal transition in Bi-2223/Ag superconducting multifilamentary tapes by conduction cooling. Some experiments were carried with operating temperature, 10-40K, and transport current as parameters in zero magnetic field. Sample tapes are transited normally with heater to intiate a quench. The voltage and temperature properties which accord to normal transition are measured by voltage taps and thermocouples attached to sample tapes, we also calculated longitudinal and transverse directions normal-zone propagation velocities from the voltage traces.

  • PDF

멥쌀과 찹쌀전분의 초미립분쇄 후 특성변화연구 (Characterization of pulverized normal and waxy rice starches)

  • 한정아
    • 한국식품조리과학회지
    • /
    • 제29권6호
    • /
    • pp.833-839
    • /
    • 2013
  • Separated normal and waxy rice starches were pulverized, and the physicochemical and digestive properties of the starches were determined. The size of both starch granules significantly decreased (less than $8{\mu}m$) after pulverization. For pasting properties, significant decreases of peak and setback viscosity were observed in both of pulverized starches than in native ones. The lower pasting temperature as well as increased solubility and water binding capacity of pulverized starches imply molecular degradation of starch by pulverization. For thermal properties, onset temperature and melting enthalpy significantly decreased after pulverization, especially in normal rice starch, however there was no difference in amylose-lipid complex before andafter pulverization. The slowly digestible and resistant starch portion of normal rice starch increased after pulverization, however, in waxy rice starch, the rapidly digestible portion increased.

HTS 케이블용 은시스 Bi-2223 테이프 및 원통형 적층 도체의 상전도 영역전파 특성 (Normal Zone Propagation Properties of Ag Sheathed Bi-2223 Tape for HTS Cable and Cylindrical Stacked Conductor)

  • 이병성;김영석;장현만;백승명;김상현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.448-451
    • /
    • 2000
  • Normal zone propagation(NZP) characteristics were investigated on Ag sheathed Bi-2223 tape and cylindrical stacked conductor. Normal zone propagation(N2P) experiments with tape were conducted with refrigerator in temperature from 45 K to 77 K, 0 T. Cylindrical stacked conductor was molding with epoxy and experiments were conducted with adiabatic condition in $LN_2$. NZP velocities of tape with two condition of DC and AC were almost same at each temperature. NZP velocities of cylindrical stacked conductor were 1.9-2.4 cdsec in $LN_2$. Numerical analysis was carried out by a one-dimensional heat balance equation. As a result, simulated results of NZP velocity with Bi-2223 tape were similar to experimental results in DC.

  • PDF