• Title/Summary/Keyword: normal resonance

Search Result 686, Processing Time 0.026 seconds

The role of the iliotibial band cross-sectional area as a morphological parameter of the iliotibial band friction syndrome: a retrospective pilot study

  • Park, Jiyeon;Cho, Hyung Rae;Kang, Keum Nae;Choi, Kun Woong;Choi, Young Soon;Jeong, Hye-Won;Yi, Jungmin;Kim, Young Uk
    • The Korean Journal of Pain
    • /
    • v.34 no.2
    • /
    • pp.229-233
    • /
    • 2021
  • Background: Iliotibial band friction syndrome (ITBFS) is a common disorder of the lateral knee. Previous research has reported that the iliotibial band (ITB) thickness (ITBT) is correlated with ITBFS, and ITBT has been considered to be a key morphologic parameter of ITBFS. However, the thickness is different from inflammatory hypertrophy. Thus, we made the ITB cross-sectional area (ITBCSA) a new morphological parameter to assess ITBFS. Methods: Forty-three patients with ITBFS group and from 43 normal group who underwent T1W magnetic resonance imaging were enrolled. The ITBCSA was measured as the cross-sectional area of the ITB that was most hypertrophied in the magnetic resonance axial images. The ITBT was measured as the thickest site of ITB. Results: The mean ITBCSA was 25.24 ± 6.59 ㎟ in the normal group and 38.75 ± 9.11 ㎟ in the ITBFS group. The mean ITBT was 1.94 ± 0.41 mm in the normal group and 2.62 ± 0.46 mm in the ITBFS group. Patients in ITBFS group had significantly higher ITBCSA (P < 0.001) and ITBT (P < 0.001) than the normal group. A receiver operator characteristic curve analysis demonstrated that the best cut-off value of the ITBT was 2.29 mm, with 76.7% sensitivity, 79.1% specificity, and area under the curve (AUC) 0.88. The optimal cut-off score of the ITBCSA was 30.66 ㎟, with 79.1% sensitivity, 79.1% specificity, and AUC 0.87. Conclusions: ITBCSA is a new and sensitive morphological parameter for diagnosing ITBFS, and may even be more accurate than ITBT.

Metabolic Abnormalities in Patients with Mitochondrial Myopathy Evaluated by In Vivo $^{31}$P Magnetic Resonance Spectroscopy (인($^{31}$P) 자기공명분광법을 사용하여 사립체 근질병환자와 정상인과의 대사물질 비교조사)

  • Bo-Young Choe
    • Investigative Magnetic Resonance Imaging
    • /
    • v.2 no.1
    • /
    • pp.89-95
    • /
    • 1998
  • Purpose : To investigate the phosphorus metabolic abnormalities in skeletal muscle of patients with mitochondrial myopathy using in vivo $^{31}P$ magnetic resonance spectroscopy(MRS). Materials and Methods : Patients with mitochondrial myopathy(N=10) and normal control subjects (N=10) participated. All in vivo $^{31}P$ MRS examinations were performed on 1.5T whole-body MRI/MRS system by using an image selected in vivo spectroscopy (ISIS) pulse sequence that provided a $4{\times}4{\times}4{\;}cm^{3}$ volume of interest (VOI) in the right thigh muscle tissue. Peak areas for each phophorus methabolite were measured using a Marquart algorithm. Results : The specific features in patients with mitochondrial myopathy were a significant increase of Pi/PCr ratio (p=0.003) and a significant decrease of ATP/PCr ratio (p=0.004) as compared with normal controls. In particular, the ${\beta}-ATP/PCr$ ratio between controls and patients with mitochondrial myopathy was predominantly altered. Conclusions : In vivo $^{31}P$ MRS may be a useful modality in the clinical evaluation of patients with mitochondrial myopathy based on ATP/PCr and Pi/PCr ratios in skeletal muscle tissue and provides a valuable information in further understanding disorders of muscle metabolism.

  • PDF

A Study on a Wideband Helical Antenna for Mobile Handset using Parasitic Element Effect (기생소자 효과를 이용한 이동 단말기용 광대역 헬리컬 안테나 연구)

  • 성원모;양묘근;전용승;이치우;박진희;최학근
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.9
    • /
    • pp.899-903
    • /
    • 2003
  • In this paper, a wide band helical antenna for mobile handset using parasitic element effect has been investigated. To obtain the effect of parasitic element, we utilized the cylindrical conductor which is not feed. As thickness of cylindrical conductor is increasing, second and third resonance frequency become abruptly variable. In case of that 4.5mm diameter parasitic element cylindrical conductor is inserted, normal mode helical antenna obtained bandwidth of around 900 MHz on the limit of R. L., - 5 dB.

A study on the Nonlinear Normal Mode Vibration Using Adelphic Integral

  • Huinam Rhee;Kim, Jeong-Soo
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.12
    • /
    • pp.1922-1927
    • /
    • 2003
  • Nonlinear normal mode (NNM) vibration, in a nonlinear dual mass Hamiltonian system, which has 6$\^$th/ order homogeneous polynomial as a nonlinear term, is studied in this paper. The existence, bifurcation, and the orbital stability of periodic motions are to be studied in the phase space. In order to find the analytic expression of the invariant curves in the Poincare Map, which is a mapping of a phase trajectory onto 2 dimensional surface in 4 dimensional phase space, Whittaker's Adelphic Integral, instead of the direct integration of the equations of motion or the Birkhoff-Gustavson (B-G) canonical transformation, is derived for small value of energy. It is revealed that the integral of motion by Adelphic Integral is essentially consistent with the one obtained from the B-G transformation method. The resulting expression of the invariant curves can be used for analyzing the behavior of NNM vibration in the Poincare Map.

Normal ossification of the glenoid mimicking a glenoid fracture in an adolescent patient: a case report

  • Maria Galan-Olleros;Rosa M. Egea-Gamez;Angel Palazon-Quevedo;Sergio Martinez-Alvarez;Olga M. Suarez Traba;Marta Escribano Perez
    • Clinics in Shoulder and Elbow
    • /
    • v.26 no.3
    • /
    • pp.306-311
    • /
    • 2023
  • A 13-year-old male was diagnosed with a glenoid fracture following direct shoulder trauma, for which surgical treatment was considered. After referral to a center for pediatric orthopedic care, physical examination, contralateral shoulder X-ray, and detailed computed tomography examination ruled out the presence of fracture; these findings were later confirmed by magnetic resonance imaging. Normal ossification patterns in the adolescent shoulder may simulate a fracture in traumatic settings. To accurately diagnose and manage pediatric shoulder pathology, orthopedic surgeons must be aware of the normal anatomy of the growing shoulder, its secondary ossification centers, and growth plates.

Radiofrequency Coil Design for in vivo Sodium Magnetic Resonance Imaging of Mouse Kidney at 9.4T

  • Lim, Song-I;Woo, Chul-Woong;Kim, Sang-Tae;Choe, Bo-Young;Woo, Dong-Cheol
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.1
    • /
    • pp.65-70
    • /
    • 2018
  • The objective of this study was to describe a radiofrequency (RF) coil design for in vivo sodium magnetic resonance imaging (MRI) for use in small animals. Accumulating evidence has indicated the importance and potential of sodium imaging with improved magnet strength (> 7T), faster gradient, better hardware, multi-nucleus imaging methods, and optimal coil design for patient and animal studies. Thus, we developed a saddle-shaped sodium volume coil with a diameter/length of 30/30 mm. To evaluate the efficiency of this coil, bench-level measurement was performed. Unloaded Q value, loaded Q value, and ratio of these two values were estimated to be 352.8, 211.18, and 1.67, respectively. Thereafter, in vivo acquisition of sodium images was performed using normal mice (12 weeks old; n = 5) with a two-dimensional gradient echo sequence and minimized echo time to increase spatial resolution of images. Sodium signal-to-noise ratio in mouse kidneys (renal cortex, medulla, and pelvis) was measured. We successfully acquired sodium MR images of the mouse kidney with high spatial resolution (approximately 0.625 mm) through a combination of sodium-proton coils.

Testicular Epidermoid Cyst on Diffusion-Weighted MR Imaging and ADC Map : A Case Report (확산강조영상과 현상확산계수(ADC) 영상을 통한 고환 표피 낭종의 진단: 증례 보고)

  • Kim, Mi-Sun;Kim, Kyung-Ah;Chang, Sun-Hee
    • Investigative Magnetic Resonance Imaging
    • /
    • v.15 no.2
    • /
    • pp.154-159
    • /
    • 2011
  • Testicular epidermoid cyst is a rare benign tumor, accounting for 1-2% of all testicular tumors. It can be cured by organ preserving surgery, so accurate preoperative diagnosis is very important for preventing unneccessary and extensive orchiectomy. We experienced a case of an 18-year-old man who presented with a painless lump in his right testis. The testicular mass showed an onion ring sign on ultrasonography. Computed tomography images showed the mass as a low attenuating lesion with curvilinear calcification. On Magnetic resonance imaging (MRI), the mass appeared as high signal intensity with internal alternating low signal intensity patterns on T2-weighted images. The mass was displayed as having homogeneous high signal intensity on diffusion magnetic resonance imaging and showed lower apparent diffusion coefficient values than normal testis parenchyma, similar to intracranial epidermoid cysts. Testicular MRI with DWI and ADC map can help to more accurately diagnose testicular epidermoid cyst.

Comparison of Dynamic Characteristics of a Wind and Photovoltaic Hybrid Light Pole Structure with 2-bladed and 3-bladed Vertical Axis Turbine Rotors Using Vibration Measurement under Normal Operation Conditions (2엽 및 3엽 수직축 풍력-태양광 하이브리드 가로등의 발전 중 진동계측을 통한 동적 특성 비교)

  • Yi, Jin-Hak;Park, Sangmin;Yim, Sungyul
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.5
    • /
    • pp.118-125
    • /
    • 2019
  • In this study, the vibration characteristics and the resonance phenomena of a wind-solar hybrid light pole structure are compared with respect to the wind turbine type through the dynamic response measurement. Two different turbines are considered including 2-bladed and 3-bladed vertical axis wind turbine rotors. The resonance phenomenon that can occur in hybrid light pole structure is analyzed by comparing the dynamic characteristics of the structure and the excitation force under operational conditions. Displacement responses are also estimated using the acceleration measurement data by use of recently proposed method, and it is observed that the amplitude of dynamic displacement responses are in the range of 4-6 cm under the resonance in the case of 2-bladed turbine and those are limited under 2 mm in the case of 3-bladed turbine because there is no resonance.

Severe Paraspinal Muscle Atrophy with Fatty Degeneration in a Young Adult: A Case Report (젊은 성인의 척추주위근에 발생한 지방 변성을 동반한 심한 근위축: 증례보고)

  • Huh, Jae-Won;Yang, Won-Jong;Park, Eunhee;Lee, Jae Eun;Kim, Chul-Hyun
    • Journal of Electrodiagnosis and Neuromuscular Diseases
    • /
    • v.20 no.2
    • /
    • pp.130-134
    • /
    • 2018
  • A 36-year-old male patient developed diffuse low back pain. His past medical history was unremarkable and had no family history of neuromuscular disease. He had no bladder and bowel problems. Creatine kinase was 172 U/L (normal < 170). Other fluid and blood chemistry tests were normal. Manual muscle test grades of extremities and sensory examination were normal. Muscle stretch reflexes were normal. Fasciculations and myotonia were not detected. Straight leg raising test was negative. There was no spinal root compression, spinal stenosis, or signal intensity change of spinal cord on magnetic resonance imaging (MRI). Fatty change and atrophy of the cervical, thoracic and lumbar paraspinal muscles were noted on MRI. Nerve conduction studies were normal. Electromyography showed 1+ positive sharp waves in the lumbar paraspinal muscles. Electromyography of upper and lower extremity muscles revealed no abnormal spontaneous activity. We report a rare case of severe paraspinal muscle atrophy with fatty degeneration in a Young Adult.

Implementation of the Classification using Neural Network in Diagnosis of Liver Cirrhosis (간 경변 진단시 신경망을 이용한 분류기 구현)

  • Park, Byung-Rae
    • Journal of Intelligence and Information Systems
    • /
    • v.11 no.1
    • /
    • pp.17-33
    • /
    • 2005
  • This paper presents the proposed a classifier of liver cirrhotic step using MR(magnetic resonance) imaging and hierarchical neural network. The data sets for classification of each stage, which were normal, 1type, 2type and 3type, were analysis in the number of data was 231. We extracted liver region and nodule region from T1-weight MR liver image. Then objective interpretation classifier of liver cirrhotic steps. Liver cirrhosis classifier implemented using hierarchical neural network which gray-level analysis and texture feature descriptors to distinguish normal liver and 3 types of liver cirrhosis. Then proposed Neural network classifier learned through error back-propagation algorithm. A classifying result shows that recognition rate of normal is $100\%$, 1type is $82.8\%$, 2type is $87.1\%$, 3type is $84.2\%$. The recognition ratio very high, when compared between the result of obtained quantified data to that of doctors decision data and neural network classifier value. If enough data is offered and other parameter is considered this paper according to we expected that neural network as well as human experts and could be useful as clinical decision support tool for liver cirrhosis patients.

  • PDF