• 제목/요약/키워드: normal resonance

검색결과 685건 처리시간 0.028초

MR Imaging and Histological Findings of Experimental Cerebral Fat Embolism in Cats

  • Park Byung-Rae;Ko Seong-Jin;Kim Hwa-Gon
    • 대한의생명과학회지
    • /
    • 제10권3호
    • /
    • pp.285-291
    • /
    • 2004
  • To determine the magnetic resonance (MR) imaging findings and natural history of cerebral fat embolism in a cat model, and to correlate the MR imaging and histologic fmdings. Intemel carotid artery of 11 cats was injected with 0.1 ml of triolein. T2-weighted, T1-weighted and Gd-enhanced T1-weighted images were obtained serially for 2 hours, 1 days, 4 days, 1 week, 2 weeks and 3 weeks after embolization. Any abnormal signal intensity was evaluated. After MR imaging at 3 weeks, brain tissue was obtained for light microscopic (LM) examination using hematoxylin-eosin (HE) and Luxol fast blue staining, and for electron microscopic examination. The LM examination with HE staining revealed normal histological findings in the greater part of an embolized lesion. Cystic change was observed in the gray matter of 8 cats, while in the gray and white matter of 3 cats. At LM examination, Luxol fast blue, staining demonstrated demyelination around the cystic change occurring in the white matter, and EM examination of the embolized cortex revealed sporadic intracapillary fat vacuoles (n=11) and disruption of the blood-brain barrier (n=4). Most lesions were normal, however, and perivascular interstitial edema and cellular swelling were mild compared with the control side. The greater part of an embolized lesion showed reversible findings at MR and histological examination. Irreversible focal necrosis was, however, observed in gray and white matter at weeks 3.

  • PDF

Isolated Spinal Neurocysticercosis : Unusual Ocular Presentation Mimicking Pseudotumor Cerebri

  • Seo, Jong-Hun;Seo, Hong-Ju;Kim, Seok-Won;Shin, Ho
    • Journal of Korean Neurosurgical Society
    • /
    • 제49권5호
    • /
    • pp.296-298
    • /
    • 2011
  • Spinal intradural cysticercosis is a rare manifestation of neurocysticercosis. We report a unique patient who showed visual symptoms and normal imaging of the brain caused by isolated spinal neurocysticercosis. A 59-year-old male patient was admitted to the emergency unit with a history of severe headache and progressive blurred vision. Brain computed tomographic scanning and magnetic resonance imaging showed normal cerebral anatomy without hydrocephalus. The fundoscopic evaluation by an ophthalmologist showed bilateral papilledema. Perimetry studies revealed visual field defects in both eyes. With the diagnosis of pseudotumor cerebri, a lumbar tap was attempted; however, we could not drain the cerebrospinal fluid in spite of appropriate attempts. Lumbar magnetic resonance imaging revealed multilevel intraspinal lesions that were confirmed histologically to be neurocysticercosis. An intraoperative lumbar puncture revealed an increased opening pressure and cytochemical analysis showed elevated cerebrospinal fluid protein level. The headache resolved immediately after surgery. However, the visual symptoms remained and recovered only marginally despite antihelminthic medications after six months of operation.

혈장지 단백질에 대한 핵자기 공명 분광 분석 (The proton nuclear magnetic resonance spectral analysis of human blood plasma lipoprotein)

  • 송인찬;강사욱;김노경;임정기;민병구
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1989년도 춘계학술대회
    • /
    • pp.29-34
    • /
    • 1989
  • 300 MHz proton NMR spectra of human blood plasma were analyzed by deconvolution of spectrum, and we compared its results with Fossel's test in normal (15 cases), liver cancer (14 cases) , and other cancer (14 cases) groups. This analysis had enabled us to obtain dynamic characteristics of each individual lipoprotein. As a result of deconvolution method, the VLDL and chylomicron intensity level were found to be elevated in the patients with liver cancer. Moment ratio values of $CH_2$ resonance in the raw spectrum were found to be higher than the normal group for patients with, malignant tumors other than liver cancer. These differences between the three groups could not be found in the conventional Fossel's test. We could simulate plasma spectra by addition of spectra of individual lipoproteins through deconvolution method. Further clinical trials in larger populations and additional biochemical method may shed new light on many of clinical and biochemical interests for knowing characteristics about lipoprotein not separated from blood and the background of Fossel test.

  • PDF

Physical Therapy Following Arthroscopic Rotator Cuff Repair with Graft Augmentation: A Case Report with Magnetic Resonance Imaging

  • Kim, Hyun-Joong;Lee, Seungwon
    • Physical Therapy Rehabilitation Science
    • /
    • 제10권4호
    • /
    • pp.463-469
    • /
    • 2021
  • Objective: If non-surgical treatment fails, arthroscopic rotator cuff repair (ARCR) is recommended, and ARCR considers graft augmentation in consideration of size, direction, and re-tear. It is reported to have potential benefits by improving the healing rate as it can fill the gaps that have been left behind. The purpose of this study is to investigate the effect of structural changes observed after ARCR on muscle action through magnetic resonance imaging and to investigate the effect of appropriate physical therapy required for graft augmentation in the general ARCR rehabilitation protocol. Case presentation: A 47-year-old male hospitalized for postoperative rehabilitation following ARCR participated in a 5-week physical therapy intervention. The postoperative day was 6 months, but due to shooting pain and shoulder dysfunction,and the movement of the shoulder was compensatory motion, not normal motion. Physical agents, manual therapy, and supervised exercise for 110 minutes per session were performed 3 times a week, and pain intensity, range of motion, function, and strength were evaluated. Results: As a result of the study, the patient showed positive improvement in pain intensity, range of motion, function, and strength. In addition, normal scapulohumeral rhythm movement was observed. Conclusions: According to the results of this case, appropriate physical therapy according to the compensatory motion shown in the structural changes after ARCR can positively improve the pain intensity, range of motion, function, and strength of ARCR patients.

정형보철용 금속을 이용한 자기공명영상왜곡의 정량적 평가 (Quantitative evaluation of MRI distortion using orthopedic prosthetic metal)

  • 김형균
    • 한국방사선학회논문지
    • /
    • 제7권1호
    • /
    • pp.57-62
    • /
    • 2013
  • 자기공명영상은 많은 장점에도 불구하고 체내에 정형보철이 있는 경우 자화율 차이로 영상왜곡이 발생한다. 스테인리스와 티타늄 시험편을 $65{\times}15{\times}2mm$로 동일하게 제작하여 phantom과 돼지고기에 부착 한 후 자기공명영상과의 관계를 알아보았다. phantom 영상을 통해 영상왜곡의 길이와 돼지 뼈를 통한 신호강도의 변화, 피하조직의 지방억제 정도를 정량적으로 평가 하였다. 스테인리스는 티타늄에 비해 길이 방향으로 4.4배, 높이 방향으로 2.8배 영상왜곡이 크며, 신호강도는 58.5%로 상대적으로 낮았다. 피하조직 지방억제는 Normal의 56.2%에 비해 스테인리스는 16.04%, 티타늄은 54.53%로 나타났다. 실험 결과 자기공명영상의 영상학적 진단가치는 스테인리스 보다 티타늄 금속이 부착 된 경우 더 우수한 것을 알 수 있었다.

On the nonlinear structural analysis of wind turbine blades using reduced degree-of-freedom models

  • Holm-Jorgensen, K.;Staerdahl, J.W.;Nielsen, S.R.K.
    • Structural Engineering and Mechanics
    • /
    • 제28권1호
    • /
    • pp.107-127
    • /
    • 2008
  • Wind turbine blades are increasing in magnitude without a proportional increase of stiffness for which reason geometrical and inertial nonlinearities become increasingly important. Often these effects are analysed using a nonlinear truncated expansion in undamped fixed base mode shapes of a blade, modelling geometrical and inertial nonlinear couplings in the fundamental flap and edge direction. The purpose of this article is to examine the applicability of such a reduced-degree-of-freedom model in predicting the nonlinear response and stability of a blade by comparison to a full model based on a nonlinear co-rotating FE formulation. By use of the reduced-degree-of-freedom model it is shown that under strong resonance excitation of the fundamental flap or edge modes, significant energy is transferred to higher modes due to parametric or nonlinear coupling terms, which influence the response and stability conditions. It is demonstrated that the response predicted by such models in some cases becomes instable or chaotic. However, as a consequence of the energy flow the stability is increased and the tendency of chaotic vibrations is reduced as the number of modes are increased. The FE model representing the case of infinitely many included modes, is shown to predict stable and ordered response for all considered parameters. Further, the analysis shows that the reduced-degree-of-freedom model of relatively low order overestimates the response near resonance peaks, which is a consequence of the small number of included modes. The qualitative erratic response and stability prediction of the reduced order models take place at frequencies slightly above normal operation. However, for normal operation of the wind turbine without resonance excitation 4 modes in the reduced-degree-of-freedom model perform acceptable.

자기공명영상을 이용한 근육 단면적 측정법의 활용을 위한 영상왜곡보정 (Distortion Correction in Magnetic Resonance Images on the Measurement of Muscle Cross-sectional Area)

  • 홍철표;이동훈;박지원;한봉수
    • The Journal of Korean Physical Therapy
    • /
    • 제24권2호
    • /
    • pp.66-72
    • /
    • 2012
  • Purpose: The purpose of this study is to explore the importance of the image distortion correction in the cross sectional area measurement for the iliopsas muscle, tensor fasciae latae muscle, gluteus maximus muscle and the knee extensor muscles, by using (magnetic resonance imaging) MRI. Methods: This study was performed using an open 0.32T MRI system. To estimate the image distortion, T1 images for an AAPM homogeneity/linearity phantom were acquired, and the region in which the maximum geometric distortion was less than or equal to the pixel size (1.6 mm) of the images, it was defined as the distortion correction-free region. The T2 images for a human subject's pelvis and thigh in normal positions were obtained. Then, after the regions of interest in the pelvis and thigh were moved into the distortion correction-free region, T2 images for the pelvis and thigh were scanned with the same imaging parameters used in the previous T2 imaging. The cross-sectional areas were measured in the two T2 images that were obtained in the normal position, and the distortion correction-free region, as well as the area error caused by geometric image distortion was calculated. Results: The geometrical distortion is gradually increased, from the magnet center to the outer region, in axial and coronal plane. The cross-sectional area error of gluteus maximus muscle and the knee extensors was as high as 9.27% and 3.16% in before and after distortion correction, respectively. Conclusion: The cross-sectional area of the muscles that suffered from the geometrical distortion is necessary to correct for the estimation of the intervention.

Evaluation of Hippocampal Volume Based on Various Inversion Time in Normal Adults by Manual Tracing and Automated Segmentation Methods

  • Kim, Ju Ho;Choi, Dae Seob;Kim, Seong-hu;Shin, Hwa Seon;Seo, Hyemin;Choi, Ho Cheol;Son, Seungnam;Tae, Woo Suk;Kim, Sam Soo
    • Investigative Magnetic Resonance Imaging
    • /
    • 제19권2호
    • /
    • pp.67-75
    • /
    • 2015
  • Purpose: To investigate the value of image post-processing software (FreeSurfer, IBASPM [individual brain atlases using statistical parametric mapping software]) and inversion time (TI) in volumetric analyses of the hippocampus and to identify differences in comparison with manual tracing. Materials and Methods: Brain images from 12 normal adults were acquired using magnetization prepared rapid acquisition gradient echo (MPRAGE) with a slice thickness of 1.3 mm and TI of 800, 900, 1000, and 1100 ms. Hippocampal volumes were measured using FreeSurfer, IBASPM and manual tracing. Statistical differences were examined using correlation analyses accounting for spatial interpretations percent volume overlap and percent volume difference. Results: FreeSurfer revealed a maximum percent volume overlap and maximum percent volume difference at TI = 800 ms ($77.1{\pm}2.9%$) and TI = 1100 ms ($13.1{\pm}2.1%$), respectively. The respective values for IBASPM were TI = 1100 ms ($55.3{\pm}9.1%$) and TI = 800 ms ($43.1{\pm}10.7%$). FreeSurfer presented a higher correlation than IBASPM but it was not statistically significant. Conclusion: FreeSurfer performed better in volumetric determination than IBASPM. Given the subjective nature of manual tracing, automated image acquisition and analysis image is accurate and preferable.

자기공명 촬영상 요추 추간반 병변의 판독자내 및 판독자간 해석의 다양성 (Interobserver and Interaobserver Variability in Interpretation of Lumbar Disc Abnormalities on Magnetic Resonance Images)

  • 전인호;송준혁;박향권;신규만;김성학;박동빈
    • Journal of Korean Neurosurgical Society
    • /
    • 제30권sup2호
    • /
    • pp.254-258
    • /
    • 2001
  • Objective : The terminology of degenerative disc disease lacks official standardization. Lacks of such standardization may provoke some clinical and litigation problems. The authors investigated interobserver and intraobserver variability in interpretation of lumbar disc abnormality. Methods : Magnetic resonance imaging studies of the lumbar spine performed prospectively in 50 patients, were read blindly by three doctors dealing spinal disorders, using two nomenclature. Nomenclature I was normal, bulging, protrusion, extrusion. Nomenclature II was normal, bulging, herniation without neural compression, with neural compression. Intraobserver and interobserver variation were measured statistically. Results : Interobserver agreement was 70.4-80.8% for nomenclature I, 76.2-80.2% for nomenclature II. Intraobserver agreement was 84.0-88.0% for nomenclature I, 79.2-86.8% for nomenclature II. Interobserver Kappa statistic was 0.53-0.56 for nomenclature I, 0.54-0.57 for nomenclature II. Intraobserver Kappa statistic was 0.60-0.85 for nomenclature I, 0.53-0.72 for nomenclature II. Conclusion : Experienced doctors showed only moderate interobserver agreement when interpreting disc status on lumbar magnetic resonance imaging. Intraobserver agreement was superior to interbserver. The standardization of nomenclatures for lumbar disc extension beyond interspace are needed.

  • PDF

Duplicated Internal Auditory Canal: High-Resolution CT and MRI Findings

  • Linsheng Wang;Lihong Zhang;Xian Li;Xiang Guo
    • Korean Journal of Radiology
    • /
    • 제20권5호
    • /
    • pp.823-829
    • /
    • 2019
  • Objective: To summarize the high-resolution computed tomography (HRCT) and magnetic resonance imaging (HRMRI) features of duplicated internal auditory canals (DIACs). Materials and Methods: Ear HRCT data of 64813 patients with sensorineural hearing loss (SNHL), obtained between August 2009 and November 2017, were reviewed. Among these patients, 12 (13 ears) were found to have DIACs, 9 of whom underwent HRMRI. Their images were evaluated by two otoradiologists. Results: The rate of occurrence of DIAC among SNHL patients was 0.019% (12/64813). The internal auditory canals of 13 ears were divided into double canals by complete (n = 6) and incomplete (n = 7) bony septa, with varied orientations ranging from horizontal to approximately vertical. All of the anterosuperior canals extended into the facial nerve (FN) canal, except for 1, which also extended to the vestibule. The posteroinferior canals ended in the cochlea and vestibule, except for 2, which also connected to the FN canals. Magnetic resonance images revealed that 77.8% (7/9) and 22.2% (2/9) of vestibulocochlear nerves (VCNs) were aplastic and hypoplastic, respectively. Furthermore, 88.9% (8/9) of FNs were normal, except for 1, which was hypoplastic. All of the affected ears also had other ear anomalies: a narrow, bony cochlear nerve canal was the most common other anomaly, accounting for 92.3% (12/13). Malformations of other systems were not found. Conclusion: Double-canal appearance is a characteristic finding of DIAC on HRCT, and it is usually accompanied by other ear anomalies. The VCN usually appears aplastic, with a normal FN, on HRMRI.