• Title/Summary/Keyword: normal ranges

Search Result 456, Processing Time 0.023 seconds

Cooling Performance Deficiency of Air Conditioning System According to Air Quantity Included in Refrigerant (냉매 내 공기혼입에 따른 에어컨 시스템의 냉각성능 저하)

  • Moon, Seong-Won;Min, Young-Bong;Chung, Tae-Sang
    • Journal of Biosystems Engineering
    • /
    • v.34 no.6
    • /
    • pp.470-475
    • /
    • 2009
  • This study was performed to present the diagnosis basis of cooling performance deficiency according to air quantity included in refrigerant of air-conditioner by detecting the temperatures and pressures of refrigerant pipeline. The car air-conditioner of SONATA III (Hyundai motor Co., Korea) was tested by maximum cooling condition at 1500 rpm of engine speed in the room with controlled air condition at $33\sim35^{\circ}C$ and 55~57% RH. Measured variables were temperature differences between inlet and outlet pipe surface of the compressor (Tcom), condenser (Tcon), receive dryer (Trec) and evaporator (Teva), and high pressure (HP) and low pressure (LP) in the refrigerant pipeline, and temperature difference (Tcoo) between inlet and outlet air of the cooling vent of evaporator. Control variables were the refrigerant charging weight and the vacuum degree in the refrigerant pipeline before charging refrigerant. From the test, it was represented that the measuring values of (Tcom), LP and (Tcoo) were enabled to make the diagnosis of cooling performance deficiency according to quantity included in refrigerant of air-conditioner. The ranges of Tcom, LP and Tcoo to make the diagnosis of cooling performance deficiency were respectively less than $55^{\circ}C$, more than 166.7 kPa-g(1.7 kgf/$cm^2$) and less than $13.7^{\circ}C$. In the case of using only external sensors and the condition under the normal performances of air conditioner, it was considered that the ranges of LP and Tcoo to make the diagnosis of cooling performance deficiency were respectively more than 166.7 Pa and less than $12^{\circ}C$.

An Experimental Study of Comfortable Pitch and Loudness with Target Matching: Effects on Electroglottographic and Acoustic Measures

  • Choi, Seong Hee
    • Phonetics and Speech Sciences
    • /
    • v.4 no.4
    • /
    • pp.139-146
    • /
    • 2012
  • This study was designed to examine comfort levels of pitch and loudness with target matching and their effects on electroglottographic (EGG) and acoustic measures. Twelve speakers, six males and six females, were instructed to produce /a/ sustained vowel for three seconds at a comfortable pitch and loudness level without any instruction and with a target matching procedure of either a certain f0 or SPL separately with visual and auditory feedback. The range of pitch for females and males were presented by progressing up and down randomly at intervals of 5Hz from 150 Hz to 310 Hz (total 33 frequency targets) and from 85 Hz to 190 Hz (total 22 frequency targets), respectively. The loudness levels were 65, 75, 85, 95 dB (total of four intensity targets) for both males and females. Subjective estimations of comfortable levels were obtained using a 10-point equal-appearing interval rating scale following each phonation. The results showed that males and females demonstrated similar trends in loudness levels with greatest comfort at 75 dB, whereas pitch comfort ratings showed a greater variability with females having a wider range with target matching. In the comfort levels of individuals, most male and female speakers rated higher comfort at soft, rather than loud phonations. On the other hand, most male speakers perceived highest comfort levels below the comfort pitch levels they phonated under natural conditions. Higher frequency ranges, however, were perceived to be more comfortable than those of natural condition in most female speakers, although the comfortable pitch levels in spontaneous phonations were within the comfort level ranges determined by targeted phonations. When comparing acoustic (%jitter, %shimmer, SNR) and EGG measures (CQ%) between spontaneous comfortable phonations and targeted phonations produced by the same subject at similar f0 and intensity, no significant differences were observed (p>0.05). Thus, target matching procedures may be considered a compatible and alternative method to reduce the variability of comfortable pitch and loudness levels by eliciting consistent comfortable phonations.

Analysis for Concentration Range of Fluorescein Sodium (플루오레신나트륨의 농도 범위 분석)

  • Lee, Da-Ae;Kim, Yong-Jae;Yoon, Ki-Cheol;Kim, Kwang-Gi
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.2
    • /
    • pp.67-74
    • /
    • 2020
  • Brain tumors or gliomas are fatal cancer species with high recurrence rates due to their strong invasiveness. Therefore, the goal of surgery is complete tumor resection. However, the surgery is difficult to distinguish the border because tumors and blood vessels have the same color tone and shape. The fluorescein sodium is used as a fluorescence contrast agent for boundary separation. When the external light source is irradiated, yellow fluorescence is expressed in the tumor, which helps distinguish between blood vessels and tumor boundaries. But, the fluorescence expression of fluorescence sodium depends on the concentration of fluorescein sodium and such analytical data is insufficient. The unclear fluorescence can obscure the boundaries between blood vessels and tumors. In addition, reduce the efficiency of fluorescence sodium use. This paper proposes a protocol of concentration range for fluorescence expression conditions. Fluorescent expression was observed using a near-infrared (NIR) color camera with corresponding dilution using normal saline in 1 ml microtube. The flunoresence emission density range is 1.00 mM to 0.15 mM. The fluorescence emission begin to 1.00 mM and the 0.15 mM discolor. The discolor is difficult to fluorescence emission condition obserbation. Thus, the maximum density range of the bright fluoresecein is 0.15 mM to 0.30 mM. When the concentration range of fluorescein sodium is analyzed based on the gradient of fluorescence expression and the power measurement, the brightest fluorescence is expected to facilitate the complete resection of the tumor. For the concentration range protocol, setting concentration ranges and analyzing fluorescence expression image according to saturation and brightness to find optimal fluorescence concentration are important. Concentration range protocols for fluorescence expression conditions can be used to find optimal concentrations of substances whose expression pattern varies with concentration ranges. This study is expected to be helpful in the boundary classification and resection of brain tumors and glioma.

Effect of electrical stimulation and vitamin AD3E on fracture healing in a rat model (전기자극과 vitamin AD3E가 랫드 골절치유에 미치는 영향)

  • Bae, Chun-slk;Cho, Yong-seong;Chang, Kyung-jin
    • Korean Journal of Veterinary Research
    • /
    • v.37 no.4
    • /
    • pp.863-873
    • /
    • 1997
  • Electrical stimulation and vitamin $AD_3E$ administration have been shown to enhance the repair of biological tissues such as bone, ligament and tendon, The objective of this study were (a) to investgate the therapeutic effects of different levels of electrical stimulation and vitamin $AD_3E$ administration on fracture healing in a rat model and (b) to identify the most effective voltage level. Ninety Sprague-dawley rats were divided into electrical stimulation group and vitamin $AD_3E$ administration group. Electricla stimulation group was divided into four groups on the basis of the level of current delivered. The experimental groups received current (which varied by group), while the controls, with identical electrodes, received no current. In vitamin $AD_3E$ administration group, experimental group was injected 2,500 IU of vitamin A, 1,250 IU of vitamine $D_3$, 1mg of vitamine E intramuscularly. And in control group 0.1ml of saline was injected intramuscularly. After time periods (7-day, 14-day, 21-day for stimulation all rats were tested with combination of biochemical, roentgenologic and histomorphological methods. The results obtained were as follows ; In electrical stimulation groups, serum calcium and inorganic phosphorus level of experimental and control groups showed non specific change within normal physiological ranges. In vitamin $AD_3E$ administration group, serum calcium level of experimental and control groups showed non specific changes within normal physiological ranges, while experimental group showed slightly higher serum inorganic phosphorus level. According to roentgenologic and histomorphological examination, 2V 25Hz electrical stimulation group and vitamine $AD_3E$ administration group showed statistically significant improvements in bone density and ossification reaction until day 14. The terapeutic effect of stimulation on fracture healing was similiar to that of vitamin $AD_3E$ administration. In this study stimulation of 2V 25Hz was the most effective level of electrical stimulation for the healing of fracture of rats.

  • PDF

Single-Dose Toxicity and Four Week Repeated-Dose Toxicity Study on Tensolin-F® (3,9-diferuloyl-6-oxopterocarpen) (Tensolin-F® (3,9-diferuloyl-6-oxopterocarpen)의 단회 독성시험 및 4주 반복투여 독성시험)

  • Kim, Keun-Su;Park, Sung-Min;Lee, Nam-Jin;Pyo, Hyeong-Bae;Chai, Hee-Yul;Jung, Yu-Ri;Lin, Chun-Mai;Kim, Sun-Hee;Lee, Hye-Young;Kang, Jong-Koo
    • Toxicological Research
    • /
    • v.23 no.4
    • /
    • pp.405-413
    • /
    • 2007
  • This study was to investigate single and repeated-dose toxicities of Tensolin-$F^{(R)}$, an anti-wrinkle agent, in Sprague-Dawley (SD) rats or ICR mice. In single-dose oral toxicity study, the test materials were administered once by gavage to male and female SD rats at dose levels of 0 and 2,000 mg/kg. No dead animals and abnormal necropsy findings were found in control and Tensolin-$F^{(R)}$ treated group. Therefore, the approximate lethal dose of Tensolin-$F^{(R)}$ was considered to be higher than 2,000 mg/kg in rats. In the 4-week repeated oral toxicity study, the test material was administered once daily by gavage to male and female ICR mice at dose levels of 0, 25, 50 and 100 mg/kg/day for 4-weeks. In the results, no abnormality was observed in mortality, clinical findings, body weight changes, food and water consumptions, opthalmoscopic findings, necropsy findings, histopathological findings. In hematological analysis, there was a trend of increase in reticulocyte at male 25 mg/kg, although such changes were in normal ranges. On the other hand, there was a trend of decrease in hemoglobin at female 50, 100 mg/kg, such changes were in normal ranges. In addition, serum biochemical parameters including sodium, BUN and chloride increased at 25, 50 and 100 mg/kg. Relative organ weights of right testis, brain, lung and left epididymis were increased in 100 mg/kg groups of male rats in contrast to not change in female groups. However, these changes of relative organ weights, hematological and serum biochemical parameters were not accompanied with related signs such as histopathological changes or clinical findings. In conclusion, 4-week repeated oral dose of Tensolin-$F^{(R)}$ to ICR mice did not cause apparent toxicological change at the dose of 25, 50, 100 mg/kg body weight. Consequently the no-observed-adverse-effect level (NOAEL) for Tensolin-$F^{(R)}$ in ICR mice following gavage for at least 4-week is higher than 100 mg/kg/day.

A Case of Long-Term Management of Insulinoma in a Maltese Dog (말티즈 개에서 인슐린종의 장기간 관리 증례)

  • Park, So-Young;Kang, Byeong-Teck;Kang, Ji-Houn;Chang, Dongwoo;Yang, Mhan-Pyo
    • Journal of Veterinary Clinics
    • /
    • v.30 no.5
    • /
    • pp.363-365
    • /
    • 2013
  • A 15-year-old, spayed female Maltese dog weighing 2.80 kg was referred with seizure of unknown origin. At presentation, serum biochemistry showed marked hypoglycemia (46 mg/dL; reference interval [RI], 65-118 mg/dL). There were, however, no abnormalities on electrolytes, complete blood counts, urinalysis, survey radiographs, and abdominal ultrasonography. In the adrenocorticotropic hormone (ACTH) stimulation test, pre-ACTH and post-ACTH cortisol concentrations were within normal reference ranges. Serum insulin level was normal and fructosamine level was slightly lower than reference ranges. The clinical signs, including seizure and collapse caused by hypoglycemia, were gradually resolved with oral administration of prednisolone (PDS) twice daily. Forty five weeks later, serum biochemistry revealed hypoglycemia with markedly increased insulin level. On abdominal ultrasonography, increased heterogenous echogenecity with hypoechoic lesion was found within pancreatic parenchyma. Based on these findings, the dog was presumptively diagnosed to insulinoma. Hypoglycemic seizure was resolved with higher dose of PDS (1 mg/kg, q12h). At 688 days after first presentation, the patient was still alive without recurrence of hypoglycemic seizure. This case describes long-term management with PDS monotherapy in a Maltese dog with insulinoma.

Cause Analysis in Candle Fire Investigation (양초화재 원인 감정에 관한 연구)

  • Han, Dong-Hun
    • Fire Science and Engineering
    • /
    • v.30 no.3
    • /
    • pp.104-109
    • /
    • 2016
  • Candle fires do not occur frequently, but can easily result in death. In this study, the thermal characteristics of candles and conditions and debris of candle fires were investigated to determine the causes of candle fires. The rates of decrease in weight of 10 candles were measured and found to be between 2.6 g/h and 6.7 g/h. Most candle fires are caused by the ignitiong of combustible materials close to them. The temperature near a candle ranges from about $200^{\circ}C$ to $400^{\circ}C$ at a distance of 1 cm and low ignition temperature materials such as papers can easily catch fire. The melting temperature of candles ranges between $50^{\circ}C$ and $70^{\circ}C$ and their major chemical components are fatty acids and normal hydrocarbons (over C20). Using pretreatment conditions involving the use of activated charcoal strips at $150^{\circ}C$ for 16 hours, the fire debris including candle residues were analyzed using a Gas-chromatograph/Mass-spectrometer (GC/MS).

Determination of Pelvic Limb Alignment in Small-breed Dogs (소형견종의 후지정렬 측정)

  • Kim, Jooho;Heo, SuYoung;Na, Jiyoung;Kim, Namsoo;Lee, Kichang;Jeong, Seongmok;Lee, HaeBeom
    • Journal of Veterinary Clinics
    • /
    • v.32 no.6
    • /
    • pp.481-485
    • /
    • 2015
  • The present study determined the normal reference ranges for overall pelvic limb alignment of small-breed dogs. For this purpose, 60 cadaveric canine pelvic limbs from normal small-breed dogs (Maltese, Poodle, Shih Tzu, Yorkshire Terrier). A frontal full-limb radiograph of each pelvic limb was obtained, and mechanical tibiofemoral angle (mTFA), mechanical metatarsotibial angle (mMTTA), mechanical axis-femur angle (MAFA), and mechanical axis-metatarsus angle (MAMTA) were measured from each radiograph, along with mechanical deviation of the stifle (SMAD) and tarsal joints (TMAD). The 95% CI for radiographic values of all pelvic limbs were mTFA, 5.7-7.4; mMTTA, $-2.2--0.8^{\circ}$; MAFA, $3.5-4.5^{\circ}$; MAMTA, 1.0-2.0; SMAD, 2.1-2.7%; TMAD, 0.5-1.0%. There values varied among the breeds, except for mTFA. The reference ranges can be used for diagnosing pelvic limb deformities in small-breed dogs and for planning corrective osteotomies.

Evaluation of Pregnancy and Thyroid Function (임신과 갑상선 기능의 평가)

  • Park, Chang-Eun
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.50 no.1
    • /
    • pp.1-10
    • /
    • 2018
  • During early pregnancy, before the development of a functioning thyroid gland, thyroid stimulating hormone (TSH) is a very sensitive marker of thyroid dysfunction during pregnancy. Normal values have been modified during gestation with a downward shift. The fetus is influenced by the TSH supplied by the mother. TSH and free thyroxine (FT4) concentrations vary during pregnancy and conventional units can vary between laboratories. A downward shift of the TSH reference range occurs during pregnancy, with a decrease in both the lower and upper limits of maternal TSH, relative to the typical non-pregnant TSH reference range. Each laboratory produces its own reference TSH and FT4 concentrations because there are many different assays that yield different results in pregnancy. Therefore, automated immunoassays used for serum FT4 analysis are still used widely, but the important considerations discussed above must be noted. The use of population-based, trimester-specific reference ranges remains the best way to handle this issue The slight downward shift in the upper reference range of TSH occurring in the latter first trimester (7~12 weeks) of pregnancy, typically not observed prior to 7 weeks. Their use indicates high or low levels in a quantitative manner independent of the reference ranges. These data highlight the importance of calculating population-based pregnancy-specific thyroid parameter reference intervals. A precision medicine initiative in this area will require the collection and analysis of a large number of genetic, biological, psychosocial, and environmental variables in large cohorts of individuals. Large prospective randomized controlled trials will be needed to resolve these controversies.

The Change of Lumbar Intervertebral Disc Size on Aging and Low Back Pain (노화와 요통에 따른 요추부 추간판 크기 변화)

  • Kim, Jong-Soon;Kim, Chang-Soo
    • Journal of radiological science and technology
    • /
    • v.30 no.4
    • /
    • pp.407-417
    • /
    • 2007
  • The purpose of this study is to determine whether change of the lumbar intervertebral disc diameters and size is a risk factor for development of lumbar disc lesion and this changes are associated with aging. The L4-5 and L5-S1 intervertebral disc diameters and size were measured in 50 normal subjects and 50 low back pain patients in the age range $20{\sim}60$ by MRI. The data were analysed with independent t-test to differentiation between normal subjects and low back patients. We also analysed with one-way ANOVA, Pearson correlation and simple linear regression to differentiate between different age ranges. This study has shown that older subjects of both normal and low back pain patients have significantly larger transverse diameters and sizes of the L4-5 and L5-S1 intervertebral disc, compared with those of younger subjects. In addition, low back pain patients's disc sizes were larger than normal subjects but there was statistically no significant difference. The measurement of the intervertebral disc size can be considered as a clinically useful method for diagnosis of the low back pain and aging of the intervertebral disc. However, further study should be conducted to establish normal value of intervertebral disc size on large number of subjects.

  • PDF