• Title/Summary/Keyword: normal insulation material

Search Result 38, Processing Time 0.021 seconds

A Study on the Image Processing for Effective Insulation Material Degradation Testing (효과적인 절연재료 열화검사를 위한 영상처리에 관한 연구)

  • 정기봉;오무송;김태성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.230-233
    • /
    • 1999
  • Because Insulation material is play an important part for normal work of electricity equipment, the study is advanced, but as the voltage of electricity system is raising, we required that new lnsulation material. They have excellent specific against high stress, namely the study of insulation increase and prevention diagnosis of insulation degradation of Epoxy or XLPE and so on. In this thesis. I utilize image processing technique for effective inspection of insulation material degradation.

  • PDF

Insulation Characteristic of Waste Sawdust-mixing Concrete (폐톱밥 혼입 콘크리트의 단열특성에 관한 실험적 연구)

  • Hong, Seung-Ryul;Cho, Byung-Hun;Son, Ki-Sang
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.2 s.70
    • /
    • pp.98-104
    • /
    • 2005
  • Saw dust concrete f3r finding out insulation characteristic was tested using test plate $30cm{\times}30cm{\times}5cm$. basically, molds f3r the test of compressive, tensile, normal without sawdust, $0.05\%,\;0.1\%,\;0.2\%,\; 0.4\%,\;0.6\%,\;0.8\%,\;1.0\%,\;1.2\%,\;1.4\%,\;1.6\%,\;1.5\%,\;2.0\%$, mixing proportion. heat conductivity of the saw dust concrete mixed with the above proportion was taken in this study. Thermal conduction of normal concrete depends on mixing proportion strength aggregate character, water content. all these items are specified here in fables. $1.8\%\~2.0\%$ saw-dust mising concrete shows as the faction as normal insulation material has its function. and the higher saw-dust mixing rate becomes, the thermal conduction becomes the less Then, the conclusions are that saw-dust using concrete has better insulation function than normal concrete.

Analysis of Insulation Condition in Traction Motor Stator Windings (견인전동기 고정자 권선의 절연상태 분석)

  • Kim, Hee-Dong;Park, Young
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.7
    • /
    • pp.631-635
    • /
    • 2007
  • Diagnostic, surge and ac breakdown tests are widely used to evaluate the insulation condition of stator winding in traction motor. Diagnostic test included ac current, tan delta and maximum partial discharge. The result of diagnostic test indicates that five kinds of stator windings are good condition. Surge test was peformed to confirm the healthy of turn insulation in stator windings. This test is very easy to detect the turn insulation failure between normal and defect stator windings. After completing the diagnostic test, ac breakdown test has conducted gradually increasing ac voltage, until the stator winding punctured. No. 5 stator windings failed near rated voltage of 18.9 kV The breakdown voltage of No. 1 stator windings was 13.0 kV The ac breakdown voltage of normal winding is about 1.45 times higher than that of defect windings. The failure was located in a line-end coil at the exit from the core slot.

Sound Absorption and Thermal Insulation Characteristics of Membrane Used for Sound Field Control (음장제어용 막재료의 음향 및 단열특성)

  • Jeong, Jeong-Ho;Kim, Jeong-Uk;Jeong, Jae-Gun;Cho, Byung-Wook
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.2
    • /
    • pp.103-114
    • /
    • 2012
  • Nowadays membrane material is widely used for large indoor spaces and long spaces such as traditional market. Thermal insulation and sound field control performance is considered as a main properties for design of such buildings. In this paper sound absorption and thermal insulation properties of membrane material was investigated. Firstly, normal incidence sound absorption coefficient of 10 kinds of glass wool textiles showed that sound absorption coefficient was increased in proportion of thickness and surface density of textile. Sound absorption coefficient of 4 kinds of sound absorptive inner membrane with outer membrane was tested in the reverberation chamber. Sound absorption coefficient of mid frequency range was about 0.4 ~ 0.6. Also, sound absorption coefficient was changed by the air space behind the membrane material. Secondly, sound field control performance was investigated using mock-up space. By the installation of sound absorption membrane material, reverberation time was decreased and speech intelligibility was increased. Finally, thermal resistance and room temperature in two kinds of mock-up rooms were tested, simultaneously. Results of thermal properties showed thermal insulation properties ware increased by adding inner membrane material underneath the outer membrane.

Defect detection of vacuum insulation panel using image analysis based on corner feature detection (코너 특정점 기반의 영상분석을 활용한 진공단열재 결함 검출)

  • Kim, Beom-Soo;Yang, Jeonghyeon;Kim, Yeonwon
    • Journal of Surface Science and Engineering
    • /
    • v.55 no.6
    • /
    • pp.398-402
    • /
    • 2022
  • Vacuum Insulation Panel (VIP) is an high energy efficient insulation system that facilitate slim but high insulation performance, based on based on a porous core material evacuated and encapsulated in a multi-barrier envelope. Although VIP has been on the market for decades now, it wasn't until recently that efforts have been initiated to propose a standard on aging testing. One of the issues regarding VIP is its durability and aging due to pressure and moisture dependent increase of the initial low thermal conductivity with time. It is hard to visually determine at an early stage. Recently, a method of analyzing the damage on the a material surface by applying image processing technology has been widely used. These techniques provide fast and accurate data with a non-destructive way. In this study, the surface VIP images were analyzed using the Harris corner detection algorithm. As a result, 171,333 corner points in the normal packaging were detected, whereas 32,895 of the defective packaging, which were less than the normal packaging. were detected. These results are considered to provide meaningful information for the determination of VIP condition.

A Study of the Physical Properties of Slurry and Mineral Hydrate Insulation Mixed with Polypropylene Fiber (폴리프로필렌 섬유 혼입 슬러리와 미네랄 하이드레이트 단열소재의 물리적 특성에 관한 연구)

  • La, Yun-Ho;Park, Jae-Wan;Chu, Yong-Sik
    • Journal of the Korean Ceramic Society
    • /
    • v.52 no.1
    • /
    • pp.13-18
    • /
    • 2015
  • The fabrication method used for mineral hydrate is similar to that of ALC (autoclaved lightweight concrete), but the fabrication of normal slurry with a considerable amount of a foaming agent is difficult due to material separation and collapse of the slurry. Therefore, the development of fabrication methods for normal slurry is necessary. The final product, mineral hydrate insulation, has excellent thermal properties but poor strength characteristic given the many pores. In this study, in order to fabricate normal slurry, the viscosity and foaming time of the slurry were controlled. The mixing ratio of the starting material and the polypropylene fiber was controlled to improve the strength. Mineral hydrate with polypropylene fiber showed a higher strength than that without this type of fiber. Specifically, the compressive strength of mineral hydrate with 2% polypropylene fiber added to it was more than 40% higher than that without the fiber.

Making the Insulation Mortar Mixed with Waste Paper and Sawdust (종이와 톱밥을 혼입한 단열 모르타르 재료 개발에 관한 연구)

  • Lee, Seung-Young;Son, Ki-Sang
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.3
    • /
    • pp.78-82
    • /
    • 2010
  • This study is to test insulation mortar mixed with wastepaper and sawdust to find out its insulation performance. Therefore, wastepaper and sawdust have been added to normal mortar. They are analyzed for the above purpose using compressive strength and insulation performance. It is found that the more wastepaper and sawdust will be mixed, the lower heat conductivity will be taken. Wastepaper and sawdust mixture will be more 2.0% then the insulation mortar quality can be compatible with the 3rd kind of the standard. Optimal mixture for insulation will be wast paper:sawdust=4:6. Cohesive test of materials showed that test material has stronger than stand are $0.10N/mm^2$. It is satisfactory the test result showed a range of $0.12{\sim}0.15N/mm^2$ from the test result. Optimal mixture of wastepaper and sawdust have been found out from the study comprehensively, exclusive of the proportion of wastepaper:sawdust = 8:2. It is thought that standard of length deformation; 0.5% is reasonable. This means that deformation of mortar itself can be considered. But it is also Shown that water mixture has also been sharply changed at first flow test. Therefore, it is thought that absorbed water content in the material gave considerable effect to variation rate.

Microstructure Property of High Voyage Motor Stator Insulation (고압전동기 고정자 권선 절연재료의 미세구조 특성)

  • 김희동;주영호
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.513-517
    • /
    • 1999
  • High voltage motor(rated 6.6kV and 448kw) has failed in the stator endwinding area during normal service. Experiments on microstructure property were conducted using the control and aged insulations, which were drawn out from stator windings of the high voltage motor. The analyses were characterized using stereozoom microscope(SM), scanning electron microscope(SEM) and energy dispersive X-ray spectroscopy(EDS). SM result shows that large voids are present in the interface between turn insulation and groundwall insulation. SEM results indicated that the groundwall insulation is rarely thermal stress. EDS results showed that chemical elements in the high voltage motor stator insulations were Al, Si, O, K and Fe.

  • PDF

Analysis of On-Line Partial Discharge in High Voltage Motor Stator Windings (고압전동기 고정자 권선의 운전중 부분방전 분석)

  • Lee, Sang-Kil;Kim, Hee-Dong;Kim, Kwang-Hun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05c
    • /
    • pp.152-155
    • /
    • 2002
  • During normal operation, partial discharge(PD) tests were performed using turbine generator analyzer(TGA) in high voltage motor. Epoxy-mica couplers are installed at motor terminal and analyzed PD signal using TGA. #A motor stator insulation is good because small partial discharges are detected PD pattern show that PD occurs in insulation. PD of #B motor is larger than that of #A motor and PD pattern show that positive PD larger than negative PD. It means that PD occurs between insulation and slot. And A phase PD magnitude of #B motor is large and high compare with any other phase. Therefore wedge, core and slot of #B motor need to check and repair.

  • PDF

Analysis of On-Line Partial Discharge in High Voltage Motor Stator Windings (고압전동기 고정자 권선의 운전중 부분방전 분석)

  • Lee, Sang-Kil;Kim, Hee-Dong;Kim, Kwang-Hun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05c
    • /
    • pp.199-202
    • /
    • 2002
  • During normal operation, partial discharge(PD) tests were performed using turbine generator analyzer(TGA) in high voltage motor. Epoxy-mica couplers are installed at motor terminal and analyzed PD signal using TGA. #A motor stator insulation is good because small partial discharges are detected. PD pattern show that PD occurs in insulation. PD of #B motor is larger than that of #A motor and PD pattern show that positive PD larger than negative PD. It means that PD occurs between insulation and slot. And A phase PD magnitude of #B motor is large and high compare with any other phase. Therefore wedge, core and slot of #B motor need to check and repair.

  • PDF