• 제목/요약/키워드: normal criterion

검색결과 305건 처리시간 0.251초

THE METHOD TO CONSTRUCT THE STRONG COMBINED-OPTIMAL DESIGN

  • Huang Pi-Hsiang;Liau Pen-Hwang
    • Journal of the Korean Statistical Society
    • /
    • 제35권2호
    • /
    • pp.201-212
    • /
    • 2006
  • The technique of foldover is usually used by experimenters to de-alias the effects that are interesting in follow-up experiment. Employing a $2^{k-p}$ design with resolution III or higher, Li and Lin (2003) developed an algorithm and used computer programs to search its corresponding optimal foldover design for selected 16-run and 32-run experiments. Based on the minimum aberration criterion, the strong combined-optimal design, defined by Li and Lin, is the better choice of the initial design. In this article, we apply the technique of blocking to find the strong combined-optimal designs. Furthermore, we will tabulate all 16-run and 32-run strong combined-optimal designs and their corresponding core foldover plans for practical use. Some new designs that have not appeared in the other literature but constructed by the technique of blocking are also proposed in this article.

NONINFORMATIVE PRIORS FOR LINEAR COMBINATION OF THE INDEPENDENT NORMAL MEANS

  • Kang, Sang-Gil;Kim, Dal-Ho;Lee, Woo-Dong
    • Journal of the Korean Statistical Society
    • /
    • 제33권2호
    • /
    • pp.203-218
    • /
    • 2004
  • In this paper, we develop the matching priors and the reference priors for linear combination of the means under the normal populations with equal variances. We prove that the matching priors are actually the second order matching priors and reveal that the second order matching priors match alternative coverage probabilities up to the second order (Mukerjee and Reid, 1999) and also, are HPD matching priors. It turns out that among all of the reference priors, one-at-a-time reference prior satisfies a second order matching criterion. Our simulation study indicates that one-at-a-time reference prior performs better than the other reference priors in terms of matching the target coverage probabilities in a frequentist sense. We compute Bayesian credible intervals for linear combination of the means based on the reference priors.

Preformed Arch Wire 제작(製作)을 위(爲)한 한국인(韓國人) 정상교합자(正常咬合者)의 치열궁형태(齒列弓形態)에 관(關)한 연구(硏究) (A STUDY ON THE CONFIGURATIONS OF KOREAN NORMAL DENTAL ARCHES FOR PREFORMED ARCH WIRE)

  • 김상철
    • 대한치과교정학회지
    • /
    • 제14권1호
    • /
    • pp.93-101
    • /
    • 1984
  • Human dental arches are very various in their sizes and dimensions as well as forms, so, it is very difficult to describe the shape of human dental arches as a criterion, and, further, to construct the preformed arch wires fit to them. In this study for solving these problems, the shape of eighty Korean normal lower dental arches were studied, and nine theoretical two-parameter catenary curves were derived, which were representative of all of the sample. Test were conducted which demonstrated that these nine cattenary curves would correspond with a reasonable degree of accuracy to all of the dental arches, lower and upper.

  • PDF

Noninformative Priors for the Common Intraclass Correlation Coefficient

  • Kim, Dal-Ho
    • Communications for Statistical Applications and Methods
    • /
    • 제18권2호
    • /
    • pp.189-199
    • /
    • 2011
  • In this paper, we develop the noninformative priors for the common intraclass correlation coefficient when independent samples drawn from multivariate normal populations. We derive the first and second order matching priors. We reveal that the second order matching prior dose not match alternative coverage probabilities up to the second order and is not a HPD matching prior. It turns out that among all of the reference priors, one-at-a-time reference prior satisfies a second order matching criterion. Our simulation study indicates that one-at-a-time reference prior performs better than the other reference priors in terms of matching the target coverage probabilities in a frequentist sense.

A Sanov-Type Proof of the Joint Sufficiency of the Sample Mean and the Sample Variance

  • Kim, Chul-Eung;Park, Byoung-Seon
    • Journal of the Korean Statistical Society
    • /
    • 제24권2호
    • /
    • pp.563-568
    • /
    • 1995
  • It is well-known that the sample mean and the sample variance are jointly sufficient under normality assumption. In this paper a proof of the joint sufficiency is given without using the factorization criterion. It is related to a finite Sanov-type conditional theorem, i.e., the conditional probability density of $Y_1$ given sample mean $\mu$ and sample variance $\sigma^2$, where $Y_1, Y_2, \cdots, Y_n$ are independently and identically distributed (i.i.d.) normal random variables with mean m and variance $\delta^2$, equals that of $Y_1$ given sample mean $\mu$ and sample variance $\sigma^2$, where $Y_1, Y_2, \cdots, Y_n$ are i.i.d. normal random variables with mean $\mu$ and variance $\sigma^2$.

  • PDF

통계적 처리방법을 이용한 동해안 염해 오손물의 분포특성 (The Distribution Characteristics of Salt Contaminants with Statistical Method in East Coast)

  • 최남호;박강식;한상옥
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권3호
    • /
    • pp.130-135
    • /
    • 2001
  • In this paper, the distribution characteristics of salt contaminants with the distance from sea in East coast, from Sokcho to Pusan of Korea peninsula were investigated to evaluate the design standard of KEPCO. To get the equivalent salt deposit density(ESDD), conventional brush wiping method was used. As the measuring period is comparatively short, and the measuring interval is long to check the maximum value, acquired ESDD data is very lower than the recommended value in the standard. The measured data didn't follow normal distribution, so it should take the statistical treatment. Through normalizing method, we could get a reliable probability data. In the past investigation, the accumulation characteristics of Japan is consulted to set the criterion, but the climatic condition of Korea is different to Japan. With the comparison of precipitation data and some measured data for long tern accumulation, we could set appropriate accumulation factor.

  • PDF

Measurement on comfort range of korean population's joint motions for designing and evaluating workplaces

  • 기도형
    • 대한인간공학회지
    • /
    • 제16권2호
    • /
    • pp.73-82
    • /
    • 1997
  • Daily exposure to constrained body postures and deviations from neutral postures over a long period may result in discomfort as well as pains and aches in the muscles, joints, tendons, and other soft tissues. Furthermore, it was known that poor body postures are a major cause of musculoskeletal disorders in industry. Therefore, in this study, comfort ranges of joint motions were obtained as a criterion for evaluating body postures and designing workplaces ergonomically, which were bases on subjects' perceived discomfort level estimated by magnitude estimation. Nineteen healthy male subjects participated in the laboratory study. They results showed that comfort ranges of joint motions occurred in the wrist, elbow, neck, and ankle were little less than their normal range of joint motions, but those in the back(L5/S1) and hip joint were much less than their normal ones. This fact implies that the back and jip movements are more stressful than the other joints movements. It is expected that comfort ranges of joint motions can be used as a valuable guideline when designing and evaluating workplaces.

  • PDF

송전선로 고장실적과 날씨의 통계분석을 통한 날씨기준 설정 (A Criterion using Statistical Analysis for Transmission Line outages and Weather)

  • 이승혁;신동석;김진오;전동훈;추진부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.60-62
    • /
    • 2004
  • Transmission line outage is influenced by several weather factors: wind, rain snow, temperature, cloud and humidity. And most power system reliability studies assume a failure rate. It can be calculated by transmission line outage data and weather data. Also weather is divided into normal weather and adverse weather by failure rate analysis. The effect of failure rate is discussed with both normal weather and adverse weather. It can be used in effective information about system operation and planing.

  • PDF

물이 토목섬유 사이의 접촉 전단강도에 미치는 영향 (The Effect of Water on the Interface Shear Strength between Geosynthetics)

  • 서민우;박준범;박인준
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.321-328
    • /
    • 2002
  • Various geosynthetics used as liners or the Protection layers are installed in the solid waste landfill. The interface shear strength between geosynthetics installed at the slope of the landfill is a very important variable for the safe design of bottom and cover systems in the solid waste landfill. The interface shear strengths between (1) Geomembrane(GM)/Geotexile(GT) and (2) Geomembrane(GM)/Geosynthetic Clay Liner(GCL) were estimated by a large direct shear test in this study and were evaluated by the Mohr-Coulomb failure criterion. Especially, this research is focused on the effect of water which exists between geosynthetics because interfaces become easily wet or hydrated by rain, leachate and groundwater beneath liners. The strength reduction at large displacement and the effects of the magnitude of normal stresses and GCL hydration methods also investigated. The test results showed that the interface shear strength and shear behavior varied depending upon the magnitude of normal stresses, water at the interface, and hydration methods. Summary of secant friction angles, which could be used as reference values at a site where similar geosynthetics are installed, together with normal stress and hydration condition are presented.

  • PDF

사용 중 지진 가속도계의 정상 측정과 출력전압 선형비 오차율 관계 분석 (Relationship between Normal Measurement and Error Rate of Output Voltage Linear Ratio of Seismic Accelerometer in Use)

  • 김민준;조성철;정용훈;원정훈
    • 한국안전학회지
    • /
    • 제39권2호
    • /
    • pp.65-74
    • /
    • 2024
  • We analyzed the relationship between the normal measurement of the seismic accelerometer (SA) and the error rate of the output voltage linear ratio to propose an evaluation method to determine whether the SA in use is measuring normally. Utilizing a test bed, the regular operation of SA in use was evaluated using acceleration data measured through impact tests since there are no regulations regarding performance testing of SA in use. For the used SA, the error rate of the output voltage linear ratio, which is a major performance criterion, was evaluated. We analyzed common characteristics of the SA that satisfied the impact test and the performance criteria of the output voltage linear ratio error rate. The results indicated that we must consider the decreasing trend and convergence of the error rate as the measurement angle increases, ensuring that the average value of the output voltage linear ratio error rate is within 1%.