• 제목/요약/키워드: nor damping

검색결과 10건 처리시간 0.031초

와전류 댐퍼의 동적특성 (Dynamic Characteristics of Eddy Current Damper)

  • 곽동기;황재혁;배재성
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.947-951
    • /
    • 2007
  • This paper is concerned with a new concept for the damper without neither a coil spring nor fluid. The new damper concept consists of the permanent magnets and the cylinder of the conducting material. The opposite pole magnets produces the repulsive forces and this is substituted for the coil spring. The relative motion between the magnets and conducting cylinder produces eddy currents thus resulting in the electromagnetic force, which turns out to be the damping force thus and is substituted for a damping fluid. This damper is called the eddy current damper(ECD). The important advantage of the proposed ECD is that it does not require the damping fluid and any external power and is non-contacting and relatively insensitive to temperature. In the present study, the proposed ECD was constructed and experiments were performed to investigate its dynamic characteristics. The experiments shows that the proposed ECD has the excellent damping ability.

  • PDF

교량의 지진응답거동에 작용하는 액체점성감쇠기의 감쇠효과 분석 (Damping Effects of Fluid Viscous Dampers on the Seismic Response of Bridges)

  • 정상모;안창모
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.379-386
    • /
    • 2001
  • Fluid viscous dampers have been used as energy dissipators or STU's (Shock Transmission Unit) in earthquake resistant designs for bridges. Viscous dampers have many advantages compared to other friction type or visco-elastic type of dampers. They do neither increase internal pier forces due to their out of phase response, nor produce reaction forces at the low velocities associated with thermal movements. Therefore, they anable the super structure to restore itself perfectly after a severe movement dut to seismic excitations. This paper investigates the response of bridges designed with viscous dampers in regard to damping coefficients, properties of dampers, and arrangements of dampers. For this purpose, time-history dynamic analyses have been performed using a very simple model relevant to a typical bridge example. Based on the results, it presents some design duidelines on how to determine a proper damping ratio and on how to arrange dampers. In usual cases, damping coefficients corresponding to about 0.2-0.3 of damping ratios seem to be very effective in bridge designs.

  • PDF

발포 EVA를 활용한 공동주택 층간 소음저감재 개발 (The study on using EVA (Etylene Vinyl Acetate) foam for floor damping)

  • 이근희;김비석;김경수;송민정
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.724-727
    • /
    • 2002
  • 층간차음재에 대한 관심은 증대하고 있으나 실제로 우리가 층간 차음재를 선택하는데는 많은 어려움이 있다. 여기에 소개하는 재료는 기존의 성능이나 가격을 강조하는 제품과 차별화하여 건축적 관점에서 접근이 용이할 것으로 판단되는 것이다.(중략)

  • PDF

와전류 충격완충장치의 실험적 동특성 연구 (Experimental Study for Dynamic Characteristics of Eddy Current Shock Absorber)

  • 곽동기;황재혁;배재성
    • 한국항공우주학회지
    • /
    • 제35권12호
    • /
    • pp.1089-1094
    • /
    • 2007
  • 연구에서는 코일 스프링 및 작동유체가 없는 새로운 감쇠기의 개념을 소개한다. 이 감쇠기는 영구자석과 전도체 실린더로 구성된다. 극성이 반대인 자석은 반발력을 발생시키고, 이는 코일 스프링과 같은 역할을 한다. 영구자석과 전도체 실린더 사이의 상대운동은 기전력을 발생시키는 와전류를 생성하고, 이로 인해 감쇠 유체를 대신할 수 있는 감쇠력을 만든다. 이러한 감쇠를 와전류 감쇠기라고 한다. 본 연구에서 제안된 와전류 감쇠기의 중요한 장점은 감쇠 유체 및 어떠한 외부의 전력도 필요로 하지 않고, 비접촉식이며, 온도에도 민감하지 않다. 본 연구에서는 제안된 와전류 감쇠기를 제작하고 실험을 통하여 감쇠기의 동적 특성을 조사하였다. 본 연구의 결과는 제안된 와전류 감쇠기가 우수한 감쇠 성능을 가짐을 보였다.

로켓엔진 연소기에서 공명기의 음향 동조에 미치는 유동 및 노즐 감쇠 효과에 관한 연구 (Effects of Mean Flow and Nozzle Damping on Acoustic Tuning of a Resonator in a Rocket Combustor)

  • 손채훈;박이선;김성구
    • 한국추진공학회지
    • /
    • 제10권3호
    • /
    • pp.41-47
    • /
    • 2006
  • 로켓 연소기에서 음향 공명기의 음향 동조에 미치는 평균 유동 및 노즐 감쇠 효과를 수치해석적으로 연구하였다. 본 연구에서는 분사기가 연소실내 음향 감쇠를 위한 공명기로서 사용된다. 연소실내 평균 유동의 마하수가 증가함에 따라 제 1 접선 방향 모드의 공진 주파수가 미약하게 감소하였으나 최적의 분사기 동조 길이는 거의 변화가 없었다. 노즐 감쇠는 공진 주파수나 최적 동조 길이에 영향을 미치지 못하며, 다만 음향 진동 진폭을 변화시킬 뿐이었다. 이러한 결과로부터, 평균 유동과 노즐 감쇠가 음향 공 동조에 미치는 영향은 미미함을 알 수 있었다. 분사기의 장착 개수가 증가할수록 음향 진동 진폭이 감소하였으나, 분사기와 연계된 새로운 음향 모드가 발생함을 알 수 있었다.

고분자 점탄성에서 Time-Strain Non-Separability와 그 열역학적 의미 (Time-Strain Non-Separability in Polymer Viscoelasticity and Its Thermodynamic Consequence)

  • 권영돈
    • 폴리머
    • /
    • 제25권4호
    • /
    • pp.536-544
    • /
    • 2001
  • 실험적 사실에 근거하여 고분자 유체의 점탄성 구성방정식에 빈번히 적용되어온 time-strain separability 가설의 타당성을 수학적 안정성 관점에서 분석한다. 안정성 조건으로는 방정식의 빠른 응답과 관련된 Hadamard 안정성과 소산 성질에 의하여 결정되는 소산 안정성이 있으며, asymptotic 분석을 이용한 결과 가설을 따르는 구성방정식은 Hadamard 또는 소산 불안정함이 증명되었다. 응력완화 실험에서 이미 관찰된 짧은 시간영역에서 time-strain separability의 가설이 적용되지 않는다는 사실은 본 결과와 일치한다. 따라서 separability를 구성방정식에 적용하는 것은 수학적 불안정뿐 아니라 열역학적 모순점을 나타내게 되며, 또한 실험에서도 그 타당성의 한계에 주의할 필요가 있다. 더욱이 damping 함수 역시 실제와는 무관한 가상적 값을 제공하므로 damping 함수의 사용은 긴 시간영역에서 응력완화 거동을 기술하기 위한 curve fitting 이상의 의미는 없다 하겠다.

  • PDF

Seismic study of buildings with viscoelastic dampers

  • Pong, W.S.;Tsai, C.S.
    • Structural Engineering and Mechanics
    • /
    • 제3권6호
    • /
    • pp.569-581
    • /
    • 1995
  • In this paper, the seismic behavior of a 10-story building equipped with viscoelastic dampers is analyzed. The effects of ambient temperature, the thickness, the total area, and the position of the viscoelastic dampers are studied. Results indicate that the energy-absorbing capacity of viscoelastic damper decreases with increasing the ambient temperature. The thickness and the total area of viscoelastic dampers also affect the seismic mitigation capacity. The thickness cannot be too small, which is not effective in vibration reduction, nor can it be too large, which not only increases the cost but also reduces the seismic resistance. The total area of viscoelastic dampers should be determined properly for optimum damper performance at the most economical design. The mounting position of viscoelastic dampers also influences the structure's seismic performance. Numerical results show that, if properly equipped, the VE dampers can reduce the structural response both floor displacement and story shear force and increase the overall level of damping in structures during earthquakes.

콘크리트 슬래브 압축강도에 따른 바닥충격진동 및 소음특성 (Floor Impact Sound and Vibration Characteristics Affected by the Compressive Strength of Concrete)

  • 정정호;유승엽;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.796-799
    • /
    • 2005
  • In 2005, a regulation on the heavy-weight impact sound was released, which restricted concrete slab thickness of standard floor to 210mm. To reduce heavy-weight impact sound, damping materials and structural reinforcement system have been proposed. In this study, the effect of compressive strength on the heavy-weight impact vibration and sound were investigated. FEM analysis was conducted for the 34PY apartment with different concrete strength (210, 350, 420kg/cm$^2$). In addition, apartment floors with different concrete strength were constructed and the floor impact vibration and sound were measured. Results of FEM analysis and measurement show that the resonance frequency of concrete slab was increased by the increment of concrete strength. However, floor impact sound pressure level did not decrease because the nor impact vibration and sound pressure level in 63Hz band increased.

  • PDF

콘크리트에 매립된 카고메 감쇠시스템의 내진거동평가 (Seismic Behavior Evaluation of Embedded Kagome Damping Device)

  • 허무원;이상현;김종호;황재승
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제23권2호
    • /
    • pp.84-91
    • /
    • 2019
  • 최근 들어 우리나라에서도 설치와 유지관리가 용이하며 경제성이 뛰어난 강재이력형 감쇠장치를 적용하여 내진성능을 확보하고자 하는 건물들이 다수 건설되고 있다. 하지만 이러한 강재이력형 감쇠장치가 철근콘크리트 건물에 적용되는 경우 감쇠장치를 설치하기 위한 연결구조물은 전체적인 시스템을 복잡하게 만들어 감쇠장치의 신뢰도를 저하시키는 요소가 되기도 한다. 이에 본 연구에서는 기존연구에서 개발된 카고메 감쇠장치를 대상으로 별도의 연결구조 없이 철근콘크리트 지지구조물에 감쇠장치를 직접 매립할 수 있는 시스템을 제안하고자 하며, 매립길이에 따른 내진거동을 확인하여 동 시스템의 정립을 위한 기초자료를 제공하고자 한다. 실험결과, $1.0l_d$ 매립길이 실험체의 경우 카고메 감쇠장치 매립부분에서 콘 파괴와 유사한 형태의 뽑힘이 발생하였다. 반면, $2.0l_d$ 매립길이를 확보한 실험체는 실험 종료 시까지 뽑힘 및 콘 파괴 없이 안정적인 이력거동을 나타내었고 $1.0l_d$ 매립길이 대비 $2.0l_d$ 매립길이가 약 1.3배의 향상된 에너지소산능력을 나타내었다. 본 연구에서 제안하는 시스템을 적용할 경우, 기존 설치방법 변경에 따른 기타 철물 제작 비용을 줄일 수 있으며, 시공 시에도 부수적인 철물 시공을 줄여 공기를 단축할 수 있다.

1g shaking table tests on residual soils in Malaysia through different model setups

  • Lim, Jun X.;Lee, Min L.;Tanaka, Yasuo
    • Geomechanics and Engineering
    • /
    • 제16권5호
    • /
    • pp.547-558
    • /
    • 2018
  • Studies of soil dynamic properties in Malaysia are still very limited. This study aims to investigate the dynamic properties of two selected tropical residual soils (i.e., Sandy Clay and Sandy Silt) and a sand mining trail (Silty Sand) in Peninsular Malaysia using 1g shaking table test. The use of 1g shaking table test for soil dynamic testing is often constrained to large strain level and small confining pressure only. Three new experimental setups, namely large laminar shear box test (LLSBT), small chamber test with positive air pressure (SCT), and small sample test with suction (SSTS) are attempted with the aims of these experimental setups are capable of evaluating the dynamic properties of soils covering a wider range of shear strain and confining pressure. The details of each experimental setup are described explicitly in this paper. Experimental results show that the combined use of the LLSBT and SCT is capable of rendering soil dynamic properties covering a strain range of 0.017%-1.48% under confining pressures of 5-100 kPa. The studied tropical residual soils in Malaysia behaved neither as pure sand nor clay, but show a relatively good agreement with the dynamic properties of residual soils in Singapore. Effects of confining pressure and plasticity index on the studied tropical residual soils are found to be insignificant in this particular study.